• Title/Summary/Keyword: 포장배수

Search Result 165, Processing Time 0.033 seconds

Comparison of Saturated and Unsaturated Water Flows through Pavement Systems

  • Lim, Yu-Jin;Hue, Nguyen Tien
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.9-17
    • /
    • 2009
  • Most of the current drainage criteria have been developed on the basis of experimental field results and theoretical analyses of infiltration under saturated conditions. The objective of this study is to extend the understanding of pavement drainage systems by considering unsaturated condition in the sublayers. Analyses of unsaturated flows through pavements was performed by running finite element program(SEEP/W) with a range of pavement materials and drainage parameters. Meanwhile, the widely used DRIP program developed by FHWA is based on assumption of saturated condition of pavements. Differences between saturated and unsaturated condition in the sublayers of the pavements are verified. It is verified that for unsaturated conditions time to drain would take longer time compared to saturated condition.

Laboratory and Field Performance Evaluation of Acryl Resin Based Solar Radiation Reflective Pavement (아크릴 수지를 이용한 차열성 포장의 실내 및 현장 공용성 평가)

  • So, Kyung-Rock;Lee, Hyun-Jong;Baek, Jong-Eun;Lee, Sang-Yum
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.19-28
    • /
    • 2011
  • This study developed a solar radiation reflection pavement, so called a cool pavement, to lessen the urban heat island effect by coating a pavement surface with acrylic resins mixed with light-colored pigments. From a laboratory test, simulating solar heating process in pavements, the cool pavement reduced more than $12^{\circ}C$ of pavement temperature at $60^{\circ}C$ compared to a control porous pavement. With the increase of the mixing ratio of the pigments to acrylic resins, the temperature reduction effect increased, but its workability became worse due to higher viscosity. As a result, an appropriate mixing ratio was determined as 15%. The cool pavement had better durability than the control pavement: One quarter of Catabro loss and twofold dynamic stability. Its adhesion was also higher enough not to be debonded under traffic loading. In-situ noise and friction tests conducted in two field sites showed that the cool pavement reduced its noise level by 3.7dB in average and increased its friction level by 30% compared to the control pavement. The permeability of the cool pavement was little lower than the control pavement, but higher enough to satisfy the minimum requirement for porous pavements.

An Evaluation of Resistances in Porous Asphalt Concrete Mixtures due to Repeated Cyclic Freeze-Thawing (배수성 아스팔트콘크리트 혼합물의 반복 동결융해 저항성 평가)

  • Jo, Shin Haeng;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1D
    • /
    • pp.33-39
    • /
    • 2012
  • More and more pavements are suffering from damage these days due to the below-zero winter temperatures and frequent snowfalls. From this research, the freeze-thawing mechanisms of pavements will be observed, and the freeze-thawing resistance of porous asphalt concrete mixture is to be evaluated according to various assessment methods. The investigation was conducted through applying rigid and flexible pavements to freeze-thawing resistance experiments, which include various experiments such as deformation rate measurements, Lottman tests, repeated cyclic freeze-thawing experiments, stripping resistance tests and so on. Test results revealed that the porous asphalt concrete had less deformations according to temperatures compared to dense-graded asphalt concrete due to the 20% void gap. In addition, according to the freeze-thawing repetition experiments which are effected by moisture, the porous asphalt concrete mixture showed superior resistance to repeated cyclic freeze-thawing compared to other asphalt concrete mixtures due to the drainage and the voids within the specimen.

Development of a Drainage System to Mitigate Moisture Damage for Bridge Deck Pavements (교면포장의 수분손상 저감을 위한 체류수 배수공법 개발)

  • Lee, Hyun-Jong;Kim, Hyung-Bae;Seo, Jae-Woon
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.129-140
    • /
    • 2007
  • A major purpose of this study is to develop a drainage system that can quickly drain water penetrated into pavement layers to mitigate pot holes which is one of the major distress types in bridge deck pavements. This system can be established by applying a thin drainage layer between waterproof and pavement layers. The most important elements for this system are the performance of waterproof layer and construction technique for the thin drainage layer. The porous asphalt mix with the maximum aggregate size of 10mm is first developed based on the porous asphalt mix design guide proposed by NCAT, and various physical and mechanical tests are performed to confirm that the porous mix satisfies all the specification requirements. In addition, a series of laboratory tests including low-temperature bending and bonding strength tests for the MMA(Methyl Methacrylate) type of waterproofing material. It is observed from the tests that the MMA material satisfies all the specification requirements. To evaluate the Reld performance of the drainage system, a field study has been conducted on a relatively small size bridge. The QC/QA tests are conducted on the both waterproofing and pavement materials. It has been found that the drainage system works well to drain the water penetrated into the pavement layers.

  • PDF

Evaluation of the Temperature Drop Effect and the Rutting Resistance of Moisture Retaining-Porous Asphalt Pavement Using Accelerated Pavement Testing (포장가속시험을 이용한 보수형 배수성 포장의 온도저감 효과 및 소성변형 저항특성 연구)

  • Kwak, Byoung-Seok;Suh, Young-Chan;Song, Chul-Young;Kim, Ju-Won
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.97-109
    • /
    • 2009
  • One of the main causes of asphalt rutting is high temperature of the pavement. Nevertheless, there has been few research on lowering the pavement temperature for reducing rutting. This study investigated the performance characteristics of moisture-retaining porous asphalt pavement, which is known to have a temperature reducing effect. The purpose of this study is to quantify the temperature reducing effect of moisture-retaining porous asphalt pavement and its effect of reducing rutting through Accelerated Pavement Testing(APT). Additionally, the possibility of reducing the thickness of the pavement in comparison to general dense grade pavement by analyzing structural layer coefficient of moisture retaining pavement. A total of three test sections consisting of two moisture-retaining porous asphalt pavement sections and one general dense-grade porous asphalt pavement section were constructed for this study. Heating and spraying of water were carried out in a regular cycle. The loading condition was 8.2 ton of wheel load, the tire pressure of $7.03kgf/cm^2$, and the contact area of $610cm^2$. The result of this experiment revealed that the temperature reducing effect of the pavement was about $6.6{\sim}7.9^{\circ}C$(average of $7.4^{\circ}C$) for the middle layer and $7.9{\sim}9.8^{\circ}C$(average of $8.8^{\circ}C$) for surface course, resulting in a rutting reduction of 26% at the pavement surface. Additionally, the structural layer coefficient of moisture retaining pavement measured from a laboratory test was 0.173, about 1.2 times that of general dense grade pavement. The general dense-grade porous asphalt pavement test section exhibited rutting at all layers of surface course, middle layer, and base layer, while the test sections of moisture-retaining porous asphalt pavement manifested rutting mostly at surface course only.

  • PDF

Development and Estimation of Double-Drainage System in Urban Areas against Localized High-Intensity Rainfall (집중호우에 대비한 도시지역 이중배수 시스템 개발 및 평가)

  • Kim, Tae Beom;Kim, Yong In;Kim, Yong In;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.362-366
    • /
    • 2015
  • 지난 백여 년 동안 인간은 과거의 그 어떤 선조들도 이루지 못한 지식과 기술의 발전을 통해 고도로 산업화된 사회를 이루었지만, 전 지구적으로 기후변화라는 부차적인 결과와 현실에 직면하고 있다. 이상기후 현상은 전지구 규모뿐만 아니라 일정한 소규모 지역에서도 관측되고 있으며, 국내에서는 특히 특정 지역에 국한되어 단시간에 발생하는 집중호우가 대표적인 사례이다. 현재까지 집중호우 발생 지역과 정도를 예측하기란 불가능한 상태이며, 산업화와 도시화가 진행될수록 그 피해는 더욱 증가할 것으로 예상된다. 따라서 집중호우에 대비한 도시 배수 시스템을 재점검할 필요가 있으며, 기존의 배수시설을 대체할 만큼 효율적인 배수구조물의 개발이 시급하다. 기존 도시지역의 측구형 수로관에는 마감불량, 정밀시공의 어려움, 이물질의 누적과 물고임, 노출로 인한 파손, 포장층 침투수 배수문제 등 많은 문제점들이 존재한다. 따라서 본 연구에서는 기존의 측구형 수로관의 단점을 보완하는 더욱 효율적인 집수정을 개발하고자 하였다. 집수정을 덮고 있는 포장층 상부면을 따라 흐르는 표면수를 처리할 뿐만 아니라, 포장층 내부로 스며드는 침투수를 처리 가능하도록 구조체 상부에 침투수 유입공을 설치하여, 표면수와 침투수를 동시에 고려하는 이중배수 시스템을 구성하였다. 본 연구에서 개발하는 집수정 구조체는 침투수에 의한 도로 및 구조체의 내구성 감소 및 겨울철 동파 현상을 방지할 수 있을 뿐 아니라, 단순공정, 시공성 향상, 유지비용절감 등 기존 배수 시스템과 비교해 많은 장점을 내포하고 있다. 본 연구에서 개발하는 이중배수 집수정의 효율 및 배수능력 평가를 위해서는 기존의 구조체와 차별되는 침투수 유입공에 대한 평가가 선행되어야 한다. 이를 위해서 침투수 유입공에 대한 실내 실험 장치를 구축하였으며, 반복 실험을 통해 침투수 유입공을 통한 배출 능력을 평가하고자 하였다. 또한 실험 결과를 바탕으로 구조체의 효능을 결정짓는 기준을 제시하고자 한다.

  • PDF

An Evaluation of Skid Resistance Properties of Asphalt Concrete Pavement (아스팔트콘크리트 포장의 노면 미끄럼 저항성 평가)

  • Kim, Nakseok;Jeong, Haesoo
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.87-95
    • /
    • 2011
  • The skid resistant of pavement surface is an important parameter since it is directly related to the traffic safety under moving vehicular loads. In particular, it should be considered as a major factor in pavement performance evaluations to reduce the traffic accident from vehicular sliding. In this study, a portable and an automatic skid resistance tests were used to evaluate the skid resistances of the in-situ pavements. The test results showed that the skid resistance of the conventional dense graded pavement was more noticeable than the other pavement types such as the drainage pavement and the stone mastic asphalt(SMA) pavement as the service life of pavement was increased.

An Experimental Study of Permeable Concrete Pavement for Application (투수성 콘크리트포장의 실용화를 위한 실험적 연구)

  • 문한영;김성수;정호섭
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.3
    • /
    • pp.165-173
    • /
    • 1998
  • 투수성 콘크리트포장은 우천시 도로포장 노면의 배수, 차량 주행 안전성의 향상 및 소음의 저감등을 목적으로 개발된 포장이지만 주행환경 및 도로주변과의 환경조화에도 기여한다. 일반적인 배수성 아스팔트 콘크리트포장에서는 투수계수 1$\times$10-2cm/sec를 목표로 정하고 있으나 본 연구에서는 투수성 콘크리트포장의 실용화를 위한 연구의 일환으로 투수계수1$\times$10-1cm/sec를 목표로 정하여 골재의 최대치수, 잔골재율 및 단위시멘트량을 변화시킨 투수성 콘크리트의 공극률, 연속공극률 및 투수계수와 제강도를 측정한 결과에 대하여 고찰하였다. 투수성 콘크리트의 목표투수계수 1$\times$10-1cm/sec 일 때 공극률 및 연속공극률은 각각 15 %와 12%정도이며, 압축강도는 240kg/$\textrm{cm}^2$정도의값을 나타내었으며, 골재의 최대치수가 10~13mm일 경우, 잔골재율 10~20%, 단위시멘트량 380 kg/$\textrm{cm}^2$정도가 적절한 배합으로 생각된다.

A Study on the Optimum Particle Size Distribution of the Drainable Base in Mountain Road for the Prevention of the Pavement Damage by Uplift Seepage Pressure (산지도로의 상향침투수압으로 인한 포장파손 방지 배수성 기층재료의 적정입도 연구)

  • Lim, Young-Kyu;Kim, Young-Kyu;Yune, Chan-Young;Lee, Seung-Woo
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.21-29
    • /
    • 2011
  • Recently, typhoons or heavy rainfalls frequently occurred because of the effect of global warming, which caused serious damage such as landslide of mountain road, debris flow and uplift seepage pressure. Uplift seepage pressure induced on the pavement of mountain roads may cause serious pavement damage. It was known that subsurface drainage method is very effective to reduce uplift seepage pressure. Suitable permeability and stiffness of drainable base is very important to have the effectiveness of subsurface drainage. In this study, optimum particle size distribution of drainable base is investigate to meet the required permeability and bearing capacity of drainable base.