• Title/Summary/Keyword: 포기공정 제어

Search Result 9, Processing Time 0.024 seconds

Aeration control based on respirometry in a sequencing batch reactor (호흡률에 기반한 연속회분식반응조의 포기공정 제어)

  • Kim, Donghan;Kim, Sunghong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • As the sequencing batch reactor process is a time-oriented system, it has advantages of the flexibility in operation for the biological nutrient removal. Because the sequencing batch reactor is operated in a batch system, respiration rate is more sensitive and obvious than in a continuous system. The variation of respiration rate in the process well represented the characteristics of biological reactions, especially nitrification. The respiration rate dropped rapidly and greatly with the completion of nitrification, and the maximum respiration rate of nitrification showed the activity of nitrifiers. This study suggested a strategy to control the aeration of the sequencing batch reactor based on respirometry. Aeration time of the optimal aerobic period required for nitrification was daily adjusted according to the dynamics of respiration rate. The aeration time was mainly correlated with influent nitrogen loadings. The anoxic period was extended through aeration control facilitating a longer endogenous denitrification reaction time. By respirometric aeration control in the sequencing batch reactor, energy saving and process performance improvement could be achieved.

Predictive aeration control based on the respirometric method in a sequencing batch reactor (연속회분식반응조에서 호흡률에 기반한 포기공정의 예측제어)

  • Kim, Donghan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.481-489
    • /
    • 2019
  • As aeration is an energy-intensive process, its control has become more important to save energy and to meet strict effluent limits. In this study, predictive aeration control based on the respirometric method has been applied to the sequencing batch reactor (SBR) process. The variation of the respiration rate by nitrification was great and obvious, so it could be a very useful parameter for the predictive aeration control. The maximum respiration rate due to nitrification was about 60 mg O2/L·h and the maximum specific nitrification rate was about 7.5 mg N/g MLVSS·h. The aeration time of the following cycle of the SBR was daily adjusted in proportion to that which was previously determined based on the sudden decrease of respiration rate at the end of nitrification in the respirometer. The aeration time required for nitrification could be effectively predicted and it was closely related to influent nitrogen loadings. By the predictive aeration control the aerobic period of the SBR has been optimized, and energy saving and enhanced nitrogen removal could be obtained.

PLC Aapplication in Exothermic Batch Process (Exothermic Batch 공정의 PLC 응용)

  • 김연태;김영권;임채환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.639-642
    • /
    • 1990
  • 본 EXOTHERMIC BATCH 공정은 두 개의 FLUID BED REACTOR로 구성되며 여기서 다종의 제품이 생산된다. 각 제품은 그 제품 자체의 특징 온도 패턴을 갖게 되며 허용한계를 벗어나지 않는 제품을 생산하기 위해서는 그 특징 온도 패턴대로 제어되어야 하며 실패할 경우 그 배치를 포기하여야만 한다. 초기의 배치제어시스템에서는 램프 제너레이터(RAMP GENERATOR) 기능이 있는 공기식 계기가 사용되었으며 제품을 변경하기 위해서는 각 제품마다 일일이 그 특징 패턴을 수동으로 입력시켜 주어야만 했다. 이 과정에서 한 개의 파라미터를 실수하면 사용할 수 없는 제품이 된다. 다종 제품의 화학공정에서는 품질과 생산량 향상에 의한 이득 증대에 그 목표를 두고 있으며, 이와 같은 목표를 달성하기 위한 해결책은 운전자의 개입을 감소시켜주는 제어시스템으로 개선하는 것이었다. 본 논문에서는 배치공정에 있어서의 프로그래머블 콘트롤러(PROGRAMMABLE CONTROLLER)의 응용에 관하여 논술하고자 한다.

  • PDF

Control of Wastewater Treatment Removing Phosphate Based on ASM No. 2 Simplified Model and Investigation of Luxury Uptake Limitation (ASM No. 2 간략화 모델에 기초한 인산염의 제어 및 인섭취 제한현상에 대한 고찰)

  • Kim, Shin-Geol;Choi, In-Su;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.181-189
    • /
    • 2008
  • Phosphate is the limiting factor leading to the eutrophication in nature and has been usually removed by the luxury uptake of PAOs(Phosphate accumulating organisms). The purpose of this study was the control of wastewater treatment removing phosphorus. The control of wastewater treatment process was performed by optimal and adaptive control. They were performed as followings. Firstly the inflow phosphate concentration was measured and the optimal aeration time was calculated by simplified ASM No. 2 for the phosphate to be 1.0 mg/L in effluent. It was optimal control. But when the phosphate concentration in effluent was not 1.0 mg/L, adaptive control was necessary to coincide the objective of control with real value. Then it was performed as the objective phosphate concentration in effluent was changed according to calculation of errors and it was adaptive control. The wastewater treatment process had been controlled by them for about one month. The range of phosphate concentration in effluent 0.2$\sim$3.2 mg/L and the average of it was 1.0 mg/L. The limitation of luxury uptake occurred two times while wastewater treatment process was running. After the analysis of laboratory tests, we knew the reasons were the shortage of ammonia nitrogen and the excessive aeration.

A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant (하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출)

  • Kim, Min Han;Ji, Seung Hee;Jang, Jung Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • It is important to keep stable effluent water quality and minimize operation cost in biological wastewater treatment plant. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. For optimal control, The oxygen uptake rate (OUR) is realtime measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO seT-Point needed for the microorganism is suggested based on real time measurement of oxygen uptake of microorganism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal setpoint decision system by providing the necessary oxygen supply requirement to the microorganisms coping with the variations of influent loading.

Real-time Control of Biological Animal Wastewater Treatment Process and Stability of Control Parameters (생물학적 축산폐수 처리공정의 자동제어 방법 및 제어 인자의 안정성)

  • Kim, W.Y.;Jung, J.H.;Ra, C.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.251-260
    • /
    • 2004
  • The feasibility and stability of ORP, pH(mV) and DO as a real-time control parameter for SBR process were evaluated in this study. During operation, NBP(nitrogen break point) and NKP(nitrate knee point), which reveal the biological and chemical changes of pollutants, were clearly observed on ORP and pH(mV)-time profiles, and those control points were easily detected by tracking the moving slope changes(MSC). However, when balance of aeration rate to loading rate, or to OUR(oxygen uptake rate), was not optimally maintained, either false NBP was occurred on ORP and DO curves before the appearance of real NBP or specific NBP feature was disappeared on ORP curve. Under that condition, however, very distinct NBP was found on pH(mV)-time profile, and stable detection of that point was feasible by tracking MSC. These results might mean that pH(mV) is superior real-time control parameter for aerobic process than ORP and DO. Meanwhile, as a real-time control parameter for anoxic process, ORP was very stable and more useful parameter than others. Based on these results, a stable real-time control of process can be achieved by using the ORP and pH(mv) parameters in combination rather than using separately. A complete removal of pollutants could be always ensured with this real-time control technology, despite the variations of wastewater and operation condition, as well as an optimization of treatment time and capacity could be feasible.

A Study on the Circulating Water Purification System using Oxygen Solubilization and Diffusion Device (산소용해수와 확산장치를 결합한 순환형 수질정화 장치의 검증)

  • Ahn, Chang-Hyuk;Song, Ho-Myeon;Joo, Jin-Chul;Lee, Yeon-Ku;Kim, Il-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.318-318
    • /
    • 2011
  • 자연수를 가압(4~5기압)하면서 물과 공기의 비를 4:1~3:1로 혼합하면 수체 내 초미세기포(Diameter $3{\sim}10{\mu}m$)가 발생하는데 이를 산소용해수라 하며 수질정화시설 또는 양식장 등에 널리 사용되고 있다. 산소용해수의 특징은 기포의 비표면적이 넓고 10시간 이상 포화 농도를 유지하여 수체에 잔류하는 시간이 길기 때문에, 일반 산기석을 활용한 포기나 순산소 용해 등의 타 방법과 구별된다. 산소용해수의 산소전달효율은 기존 방법과 큰 차이를 보이기 때문에 실제 적용시에는 대상수를 이용하여 산소전달계수($K_{L}a$)를 사전에 산정할 필요가 있다. 본 연구에서는 한국건설기술 연구원의 안동 수자원 환경실험센터 내 실외형 콘크리트 사각반응수조에 산소용해장치 및 확산장치를 결합한 일체형 시스템을 적용시켜 2010년 9월~2011년 1월의 5개월간 결과를 분석, 본 장치의 $K_{L}a$를 산정 후 수질정화의 활용 면에서 검토하였다. $K_{L}a$의 산정에는 다양한 방법이 이용되나 용존 산소 농도의 제어에 한계가 있는 실외 대형실험장에 적합한 Lewis and Whitman의 Two-film 이론에 근거한 정상포기법을 적용하였다. 체적 $80m^3$의 수조 내에서 현장 유지용수를 대상으로 실험한 결과 산소전달계수는 $0.324\pm0.050$/min, 포화농도는 8.64 mg $O_2$/L, 도달시간은 11 /min이 산정되었으며, 이는 기존 산기석 포기의 산소전달계수 범위인 $0.105\pm0.019$ /min보다 약 3.1배 높은 결과를 보였다. 또한, 확산장치의 수류 순환 방향 및 정도를 검토하기 위하여 실험수조에서 1m단위로 격자를 구성한 후 초음파 유속계로 실측한 결과 0.0~2.5 m/s 의 평면적 유속범위를 도출하였다. 그리고 전체 순환을 고려했을 때 용존산소는 약 8시간 후 8.64 mg $O_2$/L 값에 도달하여 안정화 되었으며, 강한 수류순환과 산소용해수에 의해 하상에 존재하는 퇴적물들의 이송 및 산화촉진을 유도하였다. 이를 근거로 실험수조의 체적과 기준 가동시간인 8시간을 적용시켰을 때, 실험구 수질은 대조구와 비교하여 COD, T-N, T-P가 모두 25~35% 개선되었다. 이 결과는 여과공정 없이 단순 순환만을 고려한 물리적 수질정화 방법의 단독 활용 가능성을 나타내며, 기존 연구에서 나타난 SOD (Sediment oxygen demand) 저감 능력을 감안할 때 향후 폐쇄성 수역의 수질관리에도 효율적으로 활용할 수 있음을 시사한다.

  • PDF

Study on Removal Efficiency of Complex Wastewater from Agricultural and Industrial Plant for Advanced Treatments (고도처리를 위한 농공단지 복합폐수의 처리효율 특성에 관한 연구)

  • Seo, Tae Won;Kim, Moon Suk;Park, Young Dal;Cho, Wook Sang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.2
    • /
    • pp.53-65
    • /
    • 2012
  • This study was focused on removal efficiency of complex (or mixed) wastewater from agricultural and industrial plant for advanced treatments by HBR-II process, that was well known to be suitable to the treatment of livestock wastewater. The main purpose of this study was intended to evaluate the applicable feasibility of the HBR-II for revamping the present activated sludge process to the advanced one. And also, the settling study including the batch typed experimental column tests was performed to evaluate the coagulation stability of organic colloidal particles in wastewater. The mid-scale plant of HBR-II process between pilot and laboratory was used for this study. As F/M ratio remains constant in the range of 0.20~0.25 $BOD_5/Kg{\cdot}MLSS/Day$, the efficiency of biological treatment increased. It has been shown that the results of biodegradation study were, for removal efficiency(%), $BOD_5$ 98.4%, $COD_{Mn}$ 92.9%, SS 97.5%, T-N 91.3%, T-P 82.3%, respectively, which were relatively higher than other processes. From this study, HBR-II process would be well applied to the biological treatment of agricultural and industrial complex wastewater.

The Study of Biofouling Control and Cause Material in Hybrid Process of Pure Oxygen and Submerged Membrane Bio-reactor (순산소 고율포기시스템 및 침지식 MBR융합공정에서 Biofouling 제어 및 원인물질 규명에 관한 연구)

  • Lee, Sang-Min;Kim, Mi-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.44-53
    • /
    • 2011
  • Membrane bio-reactor (MBR) has several advantages over the conventional activated sludge process, including a high biomass, low sludge production, and better permeate quality. Therefore, the MBR have gained popularity for municipal and industrial wastewater treatment. However the MBR usually were used for sewage and low streng th wastewater treatment because of membrane fouling problem and limitation of oxygen transfer into biomass. In this study, the hybrid process combining MBR and pure oxygen was tested for high strength organic wastewater treatment in the COD loading range from 2 to $10kgCOD/m^3{\cdot}day$. The hybrid process, membrane coupled pure oxygen high compact reactor (MPHCR), had been operated for one year and operation parameters, the effect of COD loading, MLSS concentration and the location of membrane module were studied for membrane fouling characteristic. Also membrane resistance test and the component of foulant was analyzed to investigate what is specific foulant in the MBR.