• Title/Summary/Keyword: 평형 온도

Search Result 744, Processing Time 0.032 seconds

Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse (포그냉방 온실에서 측창개폐수준이 온습도 제어에 미치는 영향)

  • Kim, Young-Bok;Sung, Hyun-Soo;Yun, Nam-Kyu;Lee, Si-Young;Hwang, Seung-Jae;Kim, Hyeon-Tae;Lee, Jang-Pyung
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.265-278
    • /
    • 2011
  • Effects of the open level of the side window were studied to control the temperature and relative humidity in the fog cooling greenhouse. The greenhouse was cooled by air atomizing spray nozzles of the air and water two-fluid process. The control process includes the measuring of environmental variables, setting and coding of the water balance equations and heat balance in greenhouse, calculating of the roof window open and spray water, and operating of the motor and pump. The target temperature and relative humidity were set at $28^{\circ}C$, 75%, respectively. The three modes of the side window open level were 0%, 50% and 100%. The average dry bulb temperatures of the inside air were 28.2, 27.2 and $26.3^{\circ}C$, respectively and their standard deviation was ranged from $0.4^{\circ}C$to $0.8^{\circ}C$. Also the relative humidity of the 0% mode was the best controlled one with the average of 76.3% and the standard deviation of 2.1%.

Prediction of Axial Residual Stress in Drawn High-Carbon Wire Resulting Due to Increase in Surface Temperature (고탄소강 다단 신선 와이어의 표면 온도 상승에 의한 축방향 잔류응력 예측)

  • Kim, Dae-Woon;Lee, Sang-Kon;Kim, Byung-Min;Jung, Jin-Young;Ban, Deok-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1479-1485
    • /
    • 2010
  • In recent times, due to wire drawing of high carbon steel at a high speed to ensure a high productivity and high strength, axial residual stress are generated because of rapid increase in surface temperature. In the process, the temperatures of the wires increased because of the deformation of the wires and the friction between the die and wire. In particular, in the case of the wire drawing at a high speed, friction leads to a large temperature gradient so that considerable axial residual stress is generated on the surface. In this study, the relationship between axial residual stress and increase in the surface temperature was investigated, and a prediction model of uniform temperature was proposed. Then, a prediction model for residual stress was developed. The proposed model was verified by measuring the residual stress by X-ray diffraction on drawn wires.

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Equilibrium Fractionation of Clumped Isotopes in H2O Molecule: Insights from Quantum Chemical Calculations (양자화학 계산을 이용한 H2O 분자의 Clumped 동위원소 분배특성 분석)

  • Sehyeong Roh;Sung Keun Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.36 no.4
    • /
    • pp.355-363
    • /
    • 2023
  • In this study, we explore the nature of clumped isotopes of H2O molecule using quantum chemical calculations. Particularly, we estimated the relative clumping strength between diverse isotopologues, consisting of oxygen (16O, 17O, and 18O) and hydrogen (hydrogen, deuterium, and tritium) isotopes and quantify the effect of temperature on the extent of isotope clumping. The optimized equilibrium bond lengths and the bond angles of the molecules are 0.9631-0.9633 Å and 104.59-104.62°, respectively, and show a negligible variation among the isotopologues. The calculated frequencies of the modes of H2O molecules decrease as isotope mass number increases, and show a more prominent change with varying hydrogen isotopes over those with oxygen isotopes. The equilibrium constants of isotope substitution reactions involving these isotopologues reveal a greater effect of hydrogen mass number than oxygen mass number. The calculated equilibrium constants of clumping reaction for four heavy isotopologues showed a strong correlation; particularly, the relative clumping strength of three isotopologues was 1.86 times (HT18O), 1.16 times (HT17O), and 0.703 times (HD17O) relative to HD18O, respectively. The relative clumping strength decreases with increasing temperature, and therefore, has potential for a novel paleo-temperature proxy. The current calculation results highlight the first theoretical study to establish the nature of clumped isotope fractions in H2O including 17O and tritium. The current results help to account for diverse geochemical processes in earth's surface environments. Future efforts include the calculations of isotope fractionations among various phases of H2O isotopologues with a full consideration of the effect of anharmonicity in molecular vibration.

A Construction of the Electrostatic Pesticide Spray System and its Effectiveness in Droplets Deposition (정전방제 시스템의 구성과 약액부착 효과에 관한 연구)

  • 김명규;민영봉;문성동
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.10a
    • /
    • pp.1-4
    • /
    • 1998
  • 상온연무기와 같은 소량살포기에 의해 살포된 농약액의 입자경은 10-20$\mu\textrm{m}$ 이하의 것이 대부분이다. 미소 액적은 단시간에 공기의 습구 온도와 평형하게 되어 혼합, 확산되는 특성을 가지고 있으며 증발과 Drift현상이 발생된다. 시설원예의 경우 폐쇄환경에 있으므로 연무직후 온실내 작업의 제한, 부착력포의 불균일, 증발과 Drift량의 과다 등이 큰 문제가 된다. (중략)

  • PDF

Application of Heat Balance Model for Determination of Facilities Capacity to Overcome High Temperature in Greenhouses (온실의 고온극복설비 용량 결정을 위한 열평형 모델의 적용)

  • 남상운
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.27-30
    • /
    • 2000
  • 여름철 고온기에 시설 이용율을 높이고 안정적인 생산을 하기 위하여는 적극적인 차광 환기시스템과 증발냉각시스템을 도입하는 것이 필요하다. 이러한 시스템을 도입하기 위하여는 적정 설비용량의 결정이 중요하며, 이는 지역별 외부의 설계 기상자료로부터 구할 수 있다. 차광환기시스템에서 차광율은 작물의 종류에 따라서 결정되어야 하며 따라서, 기븐적으로 결정해야될 설계 인자는 목표온도를 달성하기 위한 필요환기율과 증발냉각시스템 의 분무수량이다. (중략)

  • PDF

수직 관다발형 비등관에서의 이상 유동 불안정성 특성 해석

  • 황대현;유연종;김긍구;장문희
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.463-468
    • /
    • 1998
  • 수직 관다발형 비등관에서의 밀도파 진동 및 유동 폭주형 이상유동 불안정성을 해석하기 위하여 선형화 기법 및 D-partition 방법론에 근거한 해석 코드(ALFS)를 개발하고 기존 실험자료 분석을 통해 코드의 예측 성능을 평가하였다. 그 결과 이상유동이 평형상태에 있는 것으로 가정하는 가장 단순한 모델인 HEM은 전반적으로 유동 불안정성 발생 시점의 열출력을 실험치보다 약 20% 정도 낮게 예측하였으며, 이상 유동의 속도 및 온도의 비평형 상태를 고려하는DEM과 DNEM에 의한 예측 결과는 7∼15%의 평균 오차 범위에서 실험 자료를 예측하는 것으로 나타났다.

  • PDF

DUPIC 핵연료 제작 조건 및 연소 조건에서 산소포텐샬 변화

  • 박광헌;양명승;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.715-720
    • /
    • 1995
  • DUPIC 핵연료의 제작 조건, 특히 소결 조건에서 필요한 O/M값에 따른 산소포텐샬을 점결함모형을 이용하여 구하였다. 산소포텐샬 값은 순수 우라니아에서보다 크게 나타났고 주요 점결함 형태의 변화로 온도에 따라 엔트로피 값의 변화가 보였다. 연소중 DUPIC핵연료의 산소포텐샬 변화는 핵연료를 닫힌 계로 보고 물질 보존 및 평형법칙을 기초로 하여 구하였다. 산소포텐샬은 초기에 급격히 증가하지만 곧 일정한 값에서 매우 완만히 증가하게 된다. O/M값도 거의 변화가 없는데, 이는 Mo의 완충작용 때문이다. 따라서 초기 Mo의 화학적 형태- 금속 또는 산화물-가 DUPIC핵연료 O/M값 변화에 큰 영향을 미칠 것으로 예측되며 DUPIC핵연료 제작시 소결 조건에 유의할 필요가 있다.

  • PDF

Forecast on Internal Condensation at Ceiling of Super-high Apartment Building Faced with Open Air (외기에 면한 초고층 아파트 천정 내부결로 예측)

  • Ahn Jae-Bong;Song Young-Woong;Choi Yoon Ki
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.626-629
    • /
    • 2003
  • This study is to forecast possible occurrence of internal condensation around parpets and H-beam located at the inside of balcony ceilings on the uppermost floor of super-high apartment buildings faced with open air in order to provide dwellers with more comfortable environment in the related space and get rid of their uneasiness about the condensation. In this study, we estimated internal condensation. which vary in accordance with humidity pressure distribution, at curtain walls, stone panels or lower parts of slabs that constitute outer space of the residence and are weak against heat, through temperature forecast and temperature distribution interpretation program at normal two-dimension temperature.

  • PDF

A Study of the Growth Rate of TiN Film Produced by Using TDEAT (TDEAT TiN 증착률에 영향을 미치는 인자들에 대한 연구)

  • 최정환;이재갑;박상준;김재호;홍해남;윤의중;김좌연
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.214-220
    • /
    • 1998
  • We have studied the factors influencing the growth rate of TiN deposited from TDEAT using a bubbler. The growth rate of TiN was primarily dependent on the bubbler temperature, deposition temperature, gas delivery line conductance and carrier gases. In addition, the heating of the gas line through which carrier gas was delivered to the bubbler increased the growth rate slightly. Also heating of the delivery gas line between the bubbler and the chamber caused the increase of the growth rate of TiN, Showing the Arrehenius behaviour with the activation energy of 0.2 eV.

  • PDF