• Title/Summary/Keyword: 평형장치

Search Result 258, Processing Time 0.027 seconds

Suspension Properties of Silty Mud in Combined Wave-Current Flow (파-흐름의 공존장에서 실트질 점토의 정상특성)

  • 김차겸;이종섭
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.4 no.1
    • /
    • pp.26-33
    • /
    • 1992
  • Physical experiments were conducted to investigate the suspension properties of silty mud in combined wave-current flow. Suspension mass when there was opposing current was much higher than that when there was following current. It is due to the fact which strong turbulent flow in the bottom is developed in the opposing current but oscillatory flow effect decreases in the following current. Critical bed shear stress for suspension of silty mud in combined wave-current flow was deduced to be $\tau$$_{c}$~0.045 N/$m^2$. Formulas expressing the relation with initial suspension rate with bed shear stress, and the relation between the former and measured significant wave height were deduced. The relationship of initial suspension rate with bed shear stress was significantly scattered, but the relationship with measured significant wave height was reasonably good. When there is wave only, vertical diffusion coefficients of sediment were calculated from the vertical concentration gradients of suspended sediment when the concentration of suspended sediment approached to nearly equilibrium state. The diffusion coefficient increased exponentially with height from the bottom in the lower half of the flow depth but were nearly constant in the upper half of the flow depth.h.

  • PDF

PM Reduction Characteristics of Partial Metal DPF with Screen Mesh Filter Structure (스크린 필터 구조 Partial Metal DPF의 PM 저감 특성)

  • Kim, Chunghui;Kim, Hyunchul;Lee, Geesoo;Choi, Jeonghwang;Chon, Munsoo;Shin, Suk Shin;Suh, Hyun Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2013
  • In this work, the 1L grade integrated metal DOC/DPF filter that can install in engine manifold position was developed to investigate the effect of platinum-coating amount of filter on the improvement of filter activation temperature and reduction of particulate matter (PM). This filter was installed in 2.9L CI engine which meets the EURO-4 emission regulation. Tests for PM reduction efficiency of filter were conducted under ND-13 mode with full-load test condition. It was revealed that the time to reach the activation temperature of metal filter ($280^{\circ}C$) was shorter as the amount of platinum-coating increased. This short activation time can be helpful for the reduction of CO and HC emissions during cold start condition. At the same time, PM reduced as the coating amount increased. The reduction percentage of $DOC_{40}$, $DOC_{20}$, and $DOC_0$ were 96.7% (2.34 mg/kW'h), 95.1% (3.47 mg/kW'h), and 94.5% (3.69 mg/kW'h) compared to previous result (71.4 mg/kW'h), respectively.

Absorption of CO2 in Aqueous K2CO3 Absorbents at Pre-Combustion Condition (연소전 조건에서 탄산칼륨계 흡수제의 이산화탄소 흡수특성)

  • You, Seung-Han;Oh, Myoung-Seog;Cha, Wang-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.993-998
    • /
    • 2011
  • The absorption capacity and initial absorption rate of $CO_2$ into aqueous $K_2CO_3$ solutions were measured by using VLE(Vapor-Liquid-Equilibrium) equipment in the pre-combustion condition. Absorption experiments were conducted within the temperature range of $40{\sim}80^{\circ}C$ while increasing the $CO_2$ pressure from 0 to 50bar. The effect of $K_2CO_3$ concentration was investigated by varying in the range of 5~20%. As a results, the absorption capacity and initial absorption rate were increased with increasing $K_2CO_3$ concentration in the absorbents. Also, the initial absorption rate was highest at $40^{\circ}C$. Further more, we have studied the effect of adding piperazine and homopiperazine to $K_2CO_3$ solutions. The results showed that absorption capacity of $CO_2$ was somewhat increased by adding piperazine.

Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads (3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기)

  • Hyun Dong-Seok;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.508-517
    • /
    • 2005
  • This paper describes a high performance voltage controller for 3-phase 4-wire UPS (Uninterruptible Power Supply) system, and proposes a new scheme of synchronous reference frame controller in order to compensate for the voltage distortions due to unbalanced and nonlinear loads. Proposed scheme can eliminate the negative sequence voltage component due to unbalanced loads and also reduce the harmonic voltage component due to non-linear loads, even when the bandwidth of voltage control loop is a very low. In order to compensate for the effects of unbalanced loads, the synchronous reference frame controller with the positive and negative sequence computation block is proposed, and the synchronous frame controller with a bandpass filter is proposed to compensate for the selected harmonic frequency of output voltage. The effectiveness of the proposed scheme has been investigated and verified through computer simulations and experiments by a 30kVA UPS.

Reactive Extraction of Organic Acid with Amine Extractant, I. (A Study on the Effects of Extractant and Solvent on the Degree of Extraction in Reactive Extraction of Organic Acid) (아민 추출제에 의한 유기산의 반응추출(I) (유기산의 반응추출시 추출도에 미치는 추출제 및 용매의 영향에 관한 연구))

  • Ryu, Oon-Hyung;Lee, Han-Seob;Yoo, Chul-Hwi;Kim, Yong-Yeul;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.203-213
    • /
    • 1996
  • In physical and reactive extraction system using equilibrium extraction equipment, the effects of extractants, concentration of extractant, and solvent on the degree of extraction were investigated. The organic acids used were acrylic acid and metacrylic acid. Extractants were n-octylamine(OA), di-n-octylamine(DOA), tri-n-octylamine(TOA) and tri-octylmetyl ammonium chloride(TOMAC ; Aliquat 336). We found that the degree of extraction for reactive extraction was 2~9 times than that for physical extraction and that effect of extractants on the degree of extraction of organic acid was the order of OA

  • PDF

A Study on the Electrical fire Analysis in Overcurrent of Low Voltage Wiring (저압 배선선로의 과전류 사고시 전기화재분석에 관한 연구)

  • Lee, Sang-Ho;Oh, Hong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.142-148
    • /
    • 2004
  • Recently, with the growth of software for electromagnetic-thermal analysis, it has been studied that the precise analysis and investigation for cause of the electrical fire using computer simulation is on the basis of theroy for electromagnetic-thermal analysis. But it is very lacking for the precise analysis and investigation of cause for the electrical fire. In this paper, we have simulated the temperature distribution of wire to current and the force between the two conductors according to the current and the distance of the vinyl flat-type electrical wire(600 V, VFF, $2C{\times}$1.25mm^2) using the finite element method(Flux2D) in a overcurrent. And we will present the cause analysis method of electrical fire by experiment for distance between the two conductors according to current and time using large current supply device(Model: EHT_EFAD, Korea) in a overcurrent.

A Study on the Treatment of Refractory Organics by Redox Reaction of Cu-Zn Metal Alloy (Cu-Zn 금속 합금의 산화.환원 반응에 의한 난분해성 COD처리에 관한 연구)

  • Song, Ju-Yeong;Park, Ji-Won;Kim, Jong-Hwa
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.166-172
    • /
    • 2013
  • The purpose of this study is to evaluate the treatment ability of refractory organics in hot rolling precess waste water by redox(reduction and oxidation) reaction. Metal is oxidized in an aqueous solution to generate electron which can reduce water to generate hydroxy radical. These hydroxy radical is very effective to conduct hydrogen abstraction reaction and addition reaction to the carbon - carbon unsaturated link. The surface area of metal alloy reaction material is more than enough to get equilibrium at a single treatment. The efficiency of COD treatment by redox reaction showed maximum at mild pH of pH 7 and pH 6. But it was not effective in acidic atmosphere of pH 3, 4, 5 and basic atmosphere of pH 8 or over. Redox reaction system in much more helpful in a commercial coagulation sedimentation treatment than exclusive system.

Blowdown Prediction of Safety Relief Valve and FSI Analysis (안전릴리프밸브의 블로우 다운 예측 및 유체-구조 연성해석)

  • Choi, Ji-Won;Jang, Si-Hwan;Lee, Kwon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.729-734
    • /
    • 2017
  • A safety relief valve is a device that relieves excessive pressure in piping lines or tanks and maintains pressure at the appropriate pressure level for use. The (pressure in the) safety valve is directly influenced by the change in the back pressure, depending on whether the vents in the spring bonnet are vented to the atmosphere or to the outlet. The back pressure is divided into the built-up back pressure and the superimposed back pressure, and the back pressure characteristics vary according to the usage conditions. The safety valve used in this study is a Conventional Safety Relief Valve. The blowdown of the safety valve is predicted by establishing the equilibrium equation between the opening force and spring force considering the back pressure characteristics. Its reliability is secured by using CFX17.1. In addition, the safety of the safety valve trim was examined through fluid-structure interaction analysis.

A Study on Remediation Characteristics of Soils Contaminated with Co using Solvent Flushing Method (Solvent Flushing방법을 이용한 코발트로 오염된 토양의 제염특성에 관한 연구)

  • 김계남;원휘준;김희연;이병직;오원진
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.55-62
    • /
    • 1999
  • The solvent flushing apparatus for soil remediation was designed. After the soil around nuclear facilities was sampled and compulsorily contaminated by Co, the characteristics remediated by solvent flushing were analyzed. Meanwhile, the nonequilibrium sorption code was developed for modelling of the soil remediation by solvent flushing, input parameters needed for modelling were measured by laboratory experiment. Experimental results are as follows : The soil around nuclear facilities belongs to Silt Loam including a lot of silt and sand. When water was used as a solvent, the higher was the hydraulic conductivity. the higher the efficiency of soil remediation was. The values calculated by the nonequilibrium sorption code agreed with experimental values more exactly than the values calculated by the equilibrium sorption code. When EDTA solution was used as a solvent. the soil remediation efficiency by EDTA solution showed higher than that by water.

  • PDF

Prediction of Glaze Ice Accretion on 2D Airfoil (2차원 에어포일의 유리얼음 형상 예측 코드 개발)

  • Son, Chan-Kyu;Oh, Se-Jong;Yee, Kwan-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.8
    • /
    • pp.747-757
    • /
    • 2010
  • The ice accreted on the airfoil is one of the critical drivers that causes the degradation of aerodynamic performance as well as aircraft accidents. Hence, an efficient numerical code to predict the accreted ice shape is crucial for the successful design of de-icing and anti-icing devices. To this end, a numerical code has been developed for the prediction of glaze ice accretion shape on 2D airfoil. Constant Source-Doublet method is used for the purpose of computational efficiency and heat transfer in the icing process is accounted for by Messinger model. The computational results are thoroughly compared against available experiments and other computation codes such as LEWICE and TRAJICE. The direction and thickness of ice horn are shown to yield similar results compared to the experiments and other codes. In addition, the effects of various parameters - temperature, free-stream velocity, liquid water contents, and droplet diameter - on the ice shape are systematically analyzed through parametric studies.