• Title/Summary/Keyword: 평판익

Search Result 32, Processing Time 0.023 seconds

Equivalent Admittance and Complex Powers in a Coupling through a Narrow Slit in a Parallel-Plate Waveguide (평행평판도파관의 좁은 슬릿을 통한 결합에 있어서 등가어드미턴스 및 복소전력)

  • Lee, Jong-Ig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2059-2065
    • /
    • 2009
  • In this study, it has been considered that the TEM wave is incident on the transverse slit in the upper plate of a short-ended parallel-plate waveguide (PPW). An equivalent slit admittance and complex power for the case of narrow slit are obtained. The conditions for the slit voltage and the complex power in case of the maximum coupling through the slit with a nearby scatterer exterior the PPW are checked.

A Study on the Coupling of a Flanged Parallel-Plate Waveguide to a Nearby Conducting Strip from the Viewpoint of Near-Field Scanning Microscopy (근접주사현미경의 관점에서 플랜지된 평행평판 도파관과 근접도체스트립과의 결합에 관한 연구)

  • Lee, Jong-Ig;Ko, Ji-Hwan;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2260-2266
    • /
    • 2009
  • In this paper, the problem of electromagnetic coupling between a slit fed by a flanged parallel-plate waveguide (FPPW) and a nearby conducting strip parallel to the slit is studied as a simplified problem for a near-field scanning microscopy (NSM). The characteristics of the FPPW are investigated from the results for the variations of the equivalent slit admittance, the reactive powers near the slit inside and outside the FPPW, the magnitude and phase of the voltage reflection coefficient of the TEM wave. The performance of the proposed apparatus as an NSM is tested by examining the effects of various geometrical parameters such as guide height, slit width, strip width, distance between slit and strip, and the ratio of slit width to guide height on the magnitude and phase of the voltage reflection coefficient of the TEM wave. From the results for the voltage reflection coefficient against the strip offset from the slit, it is found that a slit in the FPPW with smaller guide height gives higher scanning resolution and the phase variation is more sensitive than the magnitude variation.

Coupling through a narrow slit in a parallel-plate waveguide covered by a dielectric slab with a conducting strip on the slab (유전체 슬랩으로 덮힌 평행평판 도파관의 좁은 슬릿을 통한 슬랩 위의 도체 스트립과의 결합)

  • Lee, Jong-Ik;Hong, Jae-Pyo;Jo, Yeong-Gi
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.2
    • /
    • pp.68-74
    • /
    • 2000
  • The problem of electromagnetic coupling through a narrow slit in a parallel-plate waveguide(PPW) covered by a dielectric slab with a conducting strip on the slab is considered for the case that the TEM wave is incident in the PPW. Coupled integral equations for the tangential electric field in the slit and the induced current over the strip are derived and solved numerically by use of the method of moments. In order to show the effect of the conducting strip on the coupling, some numerical results for the reflected and transmitted powers in the guide, the coupled power through the slit, the equivalent slit admittance, and radiation pattern are presented. From the results, it is observed that the maximum available power coupled through the slit exterior to the PPW amounts upto 50% of the incident power in the PPW.

  • PDF

Maximum Coupling Phenomena through a Slit Fed by a Flanged Parallel-Plate Waveguide with a Conducting Strip (플랜지된 평행 평판 도파관으로 급전된 슬릿을 통한 도체 스트립과의 최대 결합 현상)

  • Lee Jong-Ig;Cho Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.6 s.109
    • /
    • pp.501-510
    • /
    • 2006
  • In this paper, the electromagnetic coupling through a slit in a flanged parallel-plate waveguide with a conducting strip is studied. The coupled integro-differential equations for the electric field over the slit and the induced current over the strip are derived and solved by use of the method of moments. The characteristics of some types of maximum coupling phenomena are investigated from the examinations of the variations of the equivalent slit admittance and the coupled power against various parameters such as the location of conducting strip, operating frequency, and strip length.

Reduction Characteristics of Electromagnetic Penetration through a Slit in a Conducting Screen by a Loaded Triangle Plate (삼각형 도체판 장하에 의한 무한 도체 평판 슬릿의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Lee, Seung-Ik;Kim, Hyo-Kyun;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.767-773
    • /
    • 2014
  • This paper presents the reduction characteristics of electromagnetic penetration through a slit in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, shape, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration and shielding effectiveness. The results show that the characteristics of penetrated electric field and shielding effectiveness depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Computational Fluid Analysis for Otter Boards ( 1 ) - Pattern of Fluid Flow Besides Otter Board - (전개판에 대한 수치해석 ( 1 ) - 전개판 주위에서의 유체흐름의 패턴 -)

  • Ko, Kwan-Soh;Kwon, Byeong-Guk;Ro, Ki-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.4
    • /
    • pp.333-340
    • /
    • 1990
  • The authors carried out a visiualizational model test by the hydrogen bubble method to examine the pattern of the fluid flow besides the simple camber type and plane type otter board in circulation water channel. The experimental conditions are velocity of flow 0.05 and 0.1m/sec, angle of attack 0$^{\circ}$~45$^{\circ}$(5$^{\circ}$step). The results obtained are as follows: 1. In the case of the simple camber type otter board located angle of attack 25$^{\circ}$, vortex at the leading edge was geneated at 1/2 of chord length. 2. Size of the vortex generated in the trailing edge was about 2~3 times larger then that of the leading edge. 3. In the case of the simple camber type otter board located angle of attack 30$^{\circ}$, separation of stream-line at leading edge was generated at 1/3 of chord length. 4. Nearest stream-line in the back side of the simple camber type otter board was bent in the direction of otter board when the angle of attack was 25$^{\circ}$ and 30$^{\circ}$, and in the case of plane type otter board was expanded outside of the flow direction. 6. Area separated of the simple camber type otter board at the angle of attack 30$^{\circ}$ was smaller then that of plane type otter board. 7. Flow speed in the back side of the simple camber type otter board was about 1.4 times faster then that in the front side, and in the case of the plane otter board about 1.2 times faster.

  • PDF

Monitoring of Low-velocity Impact Damage Initiation of Gr/Ep Panel 7sing Piezoeleetric Thin Film Sensor (압전필름센서를 이용한 복합재 평판의 저속충격 손상개시 모니터링)

  • 박찬익;김인걸;이영신
    • Composites Research
    • /
    • v.15 no.2
    • /
    • pp.11-17
    • /
    • 2002
  • The piezoelectric thin film sensor can be used to interpret variations in structural and material properties, e.g. for structural integrity monitoring and assessment. To illustrate one of this potential benefit, PVDF (polyvinylidene fluoride) film sensors are used for monitoring impact damage in Gr/Ep composite panels. Both PVDF film sensors and strain gages are attached to the surface of Gr/Ep specimens. A series of impact tests at various impact energy by changing impact mass the height are performed on the instrumented drop weight impact tester. The sensor responses are carefully examined to predict the onset of impact damage such as indentation, matrix cracking, and delamination, etc. Test results show that the particular waveforms of sensor signals implying the damage initiation and development are detected above the damage initiation impact energy. As expected, the PVDF film sensor is found to be more sensitive to impact damage initiation event than the strain gage.

Electromagnetic Transmission through Slits in Two Adjacent Conducting Parallel-Plates (근접하는 도체 평행 평판의 슬릿을 통한 전자파 투과)

  • Lee, Jong-Ig;Ko, Ji-Hwan;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.83-90
    • /
    • 2009
  • In this paper, the problem of electromagnetic transmission through slits in two parallel conducting plates which separate two half spaces is considered. The coupled integral equations for the electric field distributions over the slits are developed for the case that the TM polarized plane wave is incident on the slit and solved by the method of moments. The transmitted power beyond the slit-perforated conducting parallel plates is computed in order to check the variations of the coupled power through slits against some parameters such as the incident angle of the TM polarized wave, slit width, lateral distance between two slits, and distance between the conducting plates. When the lateral distance between two slits approaches near the multiples of half wavelengths, the transmission resonance (maximum power transmission) is observed. If the slit width in the incident side is narrow and the distance between conducting plates is small compared to the wavelength, the maximum of transmitted power is observed to be nearly independent of the incident angle and slit width. In addition, the mechanism of the transmission resonance in the present geometry is explained using a simplified geometry and its equivalent circuit.

Maximum Coupling Through a Narrow Slit in a Short-Ended Parallel-plate Waveguide with a Nearby Conducting Strip (단락종단된 평행평판 도파관의 좁은 슬릿을 통한 근접 도체스트립과의 최대 결합)

  • Lee, Jong-Ik;Jo, Yeong-Gi
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.12
    • /
    • pp.15-21
    • /
    • 2000
  • In this study, the electromagnetic coupling through a narrow slit in the upper wall of a short-ended parallel-plate waveguide(PPW) covered by a dielectric slab with a nearby conducting strip on the slab Is considered for the case that the TEM wave is incident in the PPW. Coupled integral equations whose unknowns are the slit electric field and the induced electric current over the strip are derived and solved numerically by use of the method of moments. From results, it has been observed that most of the incident power can be coupled exterior to the guide by appropriately setting the strip width and position, though the slit is very narrow. In addition, the differences between the radiation phenomena, observed in the cases that the conducting strip and the upper Plate of the PPW form a cavity and that strip behaves like a parasitic element, are discussed.

  • PDF

Shape Optimal Design of Variable Sandwich Structure (가변 샌드위치 구조물의 형상최적설계)

  • 박철민;박경진;이완익
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2162-2171
    • /
    • 1993
  • Geneal Structure optimization is utilized to minimize the weight of structures while satisfying constraints imposed on stress, displacements and natural frequencies, etc. Sandwich structures consist of inside core and outside face sheets. The selected sandwich structures are isotropic sandwich beams and isotropic sandwich plate. The face sheets are treated as membrane and assumed to carry only tensions, while the core is assumed to carry only transverse shear. The characteristic of the varying area are considered by adding the projected component of the tension to the transverse shear. The bending theory and energy method are adopted for analyzing sandwich beams and plates, respectively. In the optimization process, the cost function is the weight of a structure, and a deflection and stress constraints are considered. Design variable are thickness and tapering coefficients which determine the shape of a structure. An existing optimization code is used for solving the formulated problems.