• Title/Summary/Keyword: 평균 열관류율

Search Result 8, Processing Time 0.029 seconds

An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings (건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Recently, the insulaton design standards for reducing the energy use of buildings have been strengthened. Althoug insulation work is the most cost-effective method for reducing the primary energy consumption per unit area of a building, there are no evaluation criteria for insulation performance at the time of construction and completion inspection. The purpose of this study is to provide objective data by establishing a standard for an analysis method and a method for easily experimenting with the exterior wall thermal transmittance of an apartment house using a thermal transmittance measuring device(TESTO 435). For the exterior wall of the test subject, the specific heat per unit area exceeded 20kJ/(m2·K), and the data at the end point suitable for ISO 9869-1 were analyzed by the average method. The measured values of the thermal transmittance for 3 consecutive days converged within +5% of the desing value, and the standard deviation of the thermal transmittance by day decreased in the order of 1-Day > 3-Day > 2-Day. The standard deviation of the thermal transmittance by time period decreased in the order of 00:00~24:00 < 19:00~07:00 < 00:00~07:00. The measured value of the thermal transmittance for the time perion of 00:00 to 07:00 per day almost coincided with an error of -3% to + 2% compare to the desing value.

Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange (온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Horticultural Science & Technology
    • /
    • v.33 no.5
    • /
    • pp.647-657
    • /
    • 2015
  • To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Analysis on Heat Loss of Single-span Greenhouse Using Small-scaled Wind Tunnel (소형풍동을 이용한 단동 비닐온실의 열손실 분석)

  • Kim, Young Hwa;Kim, Hyung kow;Lee, Tae suk;Oh, Sung sik;Ryou, Young sun
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • The objective of this study is to analyze the heat transfer loss of covering materials in a single-span plastic greenhouse under the steady-state wind environment. To achieve this objective, the following were conducted: (1) design of a small-scaled wind tunnel (SCWT) to analyze heat losses of the greenhouse and its performance; (2) determination of the overall heat transfer coefficient (OHTC) for the covering materials using a small-scaled greenhouse model. The SCWT consists of the blowing, dispersion, steady flow, reduction and testing areas. Each part of the SCWT was customized and designed to maintain air flow at steady state and to minimize the variances in the SCWT test. In this study, the OHTCs of the covering materials were calculated by separating each with the roof, side wall, front and back of the small-scaled greenhouse model. The results of this study show that the OHTC of the roof increases as wind speed increases but the zones in which the increase rate of the OHTC decreased, were distinguished by wind tunnel wing speed of 2 ms-1. For the side wall, the increase rate of the OHTC was particularly higher in the 0-1 ms-1 zone.

Analysis of Building Energy Reduction Effect based on the Green Wall Planting Foundation Type Using a Simulation Program (건물일체형 패널형 벽면녹화 식재기반 유형별 건물에너지 성능 분석)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Yoon, Yong-Han
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.6
    • /
    • pp.936-946
    • /
    • 2015
  • This study is aimed to analyze the reduction performance of building energy consumption according to planting base types of panel-type green walls which can be applied to existing buildings. The performance was compared to the general performance of green walls that have demonstrated effects of improving the thermal environment and reducing building energy consumption in urban areas. The number of planting base types was 4 in total, and simulations were conducted to analyze the thermal conductivity, thermal transmittance, and overall building energy consumption rate of each planting base type. The highest thermal conductivity by the planting base type was Case C (0.053W/mK), followed by Case B (0.1W/mK) and Case D (0.17W/mK). According to the results of energy simulation, the most significant reduction of cooling peak load per unit area was Case C (1.19%), followed by Case B (1.14%) and Case D (1.01%) when compared to Case A to which green wall was not applied; and the most significant reduction of heating peak load per unit area was estimated to be Case C (2.38%), followed by Case B (1.82%) and case D (1.50%) when compared to Case A. The amount of yearly cooling and heating energy use per unit area showed 3.04~3.22% of reduction rate. The amount of the 1st energy use showed 5,844 kWh/yr of decrease on average for other types when compared to Case A. The amount of yearly $CO_2$ emission showed 996kg of decrease on average when compared to Case A to which the green wall was not applied. According to the results of energy performance evaluation by planting location, the most efficient energy performance was eastward followed by westward, southward and northward. According to the results of energy performance evaluation by planting location by green wall ratio, it was found that as the ratio of green wall increased, the energy performance displayed better results, showing approx. double reduction rate in energy consumption at 100% of green wall ratio than the reduction rate at 20% to 80% of green wall ratio.

A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping (조경용 식생매트의 열전도율 측정에 관한 연구)

  • Cha, Uk Jin;Yang, Geon Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.85-96
    • /
    • 2018
  • Developed nations have implemented various policies to reduce greenhouse gases since the 1997 Kyoto Protocol in order to minimize the effects of global warming. Korea should also reduce energy consumption in the industrial sector, and the transportation and building sectors in order to achieve its greenhouse gas reduction target of 37 percent compared to the Business As Usual levels. The government implements various laws and regulations for reducing energy consumption. To reduce energy consumption in the building sector, in particular, the Energy Conservation Design Standards are enforced according to the 'Enforcement Support for Green Building Construction'. The amount of electricity used to maintain room temperature at $28^{\circ}C$ in these buildings have a 30% reduction (measured on the walls and rooftop) in power usage compared to buildings not required to meet these standards. Although the effect of these energy savings on landscaping is proven, this demonstration is not effective for energy saving since it is not a suitable method for the 'Energy Saving Design Standards of Buildings'. For landscaping to be effective as far as a component of energy reduction, the perfusion rate of the building should be calculated based on the thermal conductivity of the component materials for the energy saving designs with respect to the basis of Article 14 of the Green Building Act. Therefore, the purpose of this study is to ensure that the planting-based mats currently being widely used in the landscape industry can have insulating performance suitable for the 'Energy Saving Design Standards' of Buildings according to the 'Enable Green Building Construction Methods'.

생강엑기스의 제조에 관한 연구

  • 신애자
    • Food Industry
    • /
    • s.94
    • /
    • pp.37-40
    • /
    • 1988
  • 1) 본 연구에서 시료로 선정한 충남 서산산 건강(dry ginger)은 수분이 $9.4\%$, 회분이 $8.7\%$ 그리고 alcohol에 의한 추출량이 약 $9\%$이다. 이는 선진국에 채택사용하고 있는 건강의 규격기준에 의하면 양호하다. 2) Non- flavor물질의 추출을 최소화하고 특히 증류과정에서 유효성분 손실을 최소화 할 수 있고, 엑기스내의 용매 잔류량이 인체에 유해하지 않고 추출효율을 높일 수 있는 용매는 ethyl alcohol이다. 3) 널리 사용하고 있는 관류추출(percolation)의 성능을 분석하고 이의 개선방안을제시하였다. - 추출효율을 높이기 위하여 건강(dry ginger)의 입자를 작게하면 압력강하가 증대되어순환되는 용액의 유속을 제어하기가 힘들다. - 입자가 작을 시에는 유체의 흐름이chan-nelling현상을 나타낸다. - 위와 같은 조건에서는 물질 전달속도가 느리므로 추출효율을 증대시킬 수가 없다. - 따라서 percolation추출에 사용되는 건강의 입자크기는 30mesh크기 이상이어야 운전조작이 용이하나 추출효율이 낮으므로, 추출시간 6시간에 회수된 생강엑기스양은 약 $2.5\%$이다. 4) percolation추출의 단점을 보완하기 위하여 기계적교반 추출을 선택하여 다음과 같은 개선점을 찾았다. - 교반형 추출에서는 고 - 액분리시 cake 저항에서 문제가 야기되지 않는 범위까지 건강의 입자를 작게할 수 있으므로 추출효율을 크게 향상시킬 수 있었다. 즉, 작게 분쇄된 건강(30mesh통과$90\%$)을 대상으로 추출시간 3시간에 $7\%$의 회수율로 증대시켰다. 최적 운전조건은 다음과 같다. 건강시료:1kg 시료크기:-30mesh$90\%$ 용매:ethyl alcohol 3$\iota$ 교반속도:900r.p.m 추출온도:상온($15\~25^{\circ}C$) 추출시간:3시간 일차 추출조건과 동일하게 하여 얻어진 엑기스의 수율이 $2\~2.5\%$이므로 총엑기스의 수율은 건강(dry ginger)무게기준으로 $8.5\~9.5\%$이었다. 5) 교반추출의 효율이 개선되었다 하더라도 추출물의 분리가 용이하여야만 공정의 이용이 가능하다. 그러므로 교반추출후 고 - 액분리를 위하여 정압여과 장치를 이용하여 여과시 cake의 평균 비저항을 얻었으며, 이의 값은 $4.31\times10^8cm\;/\;gr$으로서 여과에는 어려움이 없다는 것을 의미한다. 따라서 추출속도와 효율이 상대적으로 우수한 교반형 추출기의 가능성을 예시할 수 있음을 알 수 있었다. 6) 추출물을 농축과정에서 휘발성 oil의 손실을 최대로 줄이기 위해서는 단순증류를 하지 말고 분별증류를 수행하여야 하며, gingerol과 같은 중요성분의 열분해 반응을 억제하기 위해서는 열전달 효율을 증대시켜 증류조작을 원활히 수행하여야 하므로, still내의 농축물을 계속 교반시켜야 하며 감압상태에서 증류온도는 $40\~50^{\circ}C$로 유지시키는 것이 가장 바람직하다. 7) Ethyl alcohol로 추출된 엑기스내의 수분이나 회분함량은 외국산 제품에 비하여 약간 낮고, 반면에 조지방 및 조단백 성분의 함량은 약간 높게 나타나고 있어 대체적으로 본 연구에서 얻어진 엑기스내의 비풍미성분(non- fla-vour component) 함량은 외국산에 비하여 많은 차이가 없다. 8) 수입 외국산에 비하여 국산엑기스(본 연구에서 ethyl alcohol로 추출)내의 무기성분등의 함량은 비교적 낮은 편이다. 9) 건강에서부터 oleoresin을 얻어 paradol을 제거시킨 후 순수한 gingerol을 분리하여 IR과 NMR로 확인한 결과, 국산건강의 엑기스에는 주로 6-gingerol이고 약간의 10-gingerol이 함유된 것으로 나타났다. 10) 순수하게 분리된 gingerol을 열분석(TGA와 DTG)한 결과 약 $75^{\circ}C$에서 gingerol의 열분해 반응이 일어남을 알수 있었다. 11) 건강 분말시료와 엑기스내의 미생물 검사 결과 건강분말에서는 세균수가 많이 존재하는 것으로 나타났으나, 이는 ethyl alcohol로 추출하는 공정 중 대부분의 균들이 사멸된 것으로 나타났다. 12) 관능적 측면에선, 본 연구에서 제조한 엑기스와 수입엑기스를 비교한 결과 생강 특유의 맛은 비슷했으나, 수입엑기스에서는 쓴맛과 톱밥냄새를 느낀다는 결과를 나타내었으며 전체적인 종합적 풍미는 국산 건강엑기스가 좋은 것으로 나타났다.

  • PDF

Properties of Concrete Panel Made by Light Weight Aggregates (인공경량골재로 제조된 콘크리트 패널의 물성)

  • 엄태호;김유택
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.3
    • /
    • pp.221-228
    • /
    • 2004
  • Basic properties of artificial lightweight aggregate by using waste dusts and strength properties of LWA concrete were studied. Bulk specific gravity and water absorption of artificial lightweight aggregates varied from 1.4 to 1.7 and 13 to 16%, respectively. Crushing ratio of artificial lightweight aggregate was above 10% higher than that of crushed stone or gravel. As a result of TCLP leaching test, the leaching amount of tested heavy metal element was below the leaching standard of hazardous material. Slump, compressive strength and stress-strain properties of LWA concrete made of artificial lightweight aggregate were tested. Concrete samples derived from LWA substitution ratio of 30 vol% and W/C ratio of 45 wt% showed the best properties overall. Thermal insulation and sound insulation characteristics of light weight concrete panel with the optimum concrete proportion were tested. Average overall heat transmission of 3.293W/㎡$^{\circ}C$ was observed. It was higher by about 15% than those of normal concrete made by crushed stone. Sound transmission loss of 50.9 ㏈ in frequency of 500 ㎐ was observed. It was higher by about 13% than standard transmission loss.