• Title/Summary/Keyword: 평균유량계수

Search Result 225, Processing Time 0.025 seconds

Analysis of Correlation with Cross Sectional Area of Flow and Flow Rate Variation of Discharge Measurement Point in the Upper Stream of Seomjin River (섬진강상류 유량측정지점의 유수단면적과 유량변화에 따른 상관관계 분석)

  • Song, KwangDuck;Kim, KapSoon;Lee, DongJin;Ham, SangIn;Kim, DaeYoung;Oh, TaeYoun;Lee, JaeChoon;Lim, ByungJin
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.94-102
    • /
    • 2013
  • This study was carried out to determine the variation of the water level and crosssection area for investigating changes of stream foreland, and to determine the correlation between the average flow velocity and cross-section area so as to understand the hydrological characteristics of the stream. The slope of the cross-sectional area was changed in water levels of 0.6~1.0 m and 1.8~2.0 m. The first change occurred in the low-water level season, and the second change occurred in the high-water level seasons. It is assumed that the changes occurred due to the geological transfigure. The correlation between the cross-sectional area and the average flow velocity was 0.22~0.86 in the exponential equation and 0.20~0.87 in the linear equation. The low water level had a higher correlation than the high water level, and free weirs in the upper stream showed a very low correlation. Therefore, this study provides novel information for the management of water quality in the riverside, using correlation equations of the water level and flow velocity with the cross section area.

Environmental factors influencing acetone and Environmental factors influencing acetone and β-hydroxybutyrate acid contents in raw milk of Holstein dairy cattle (홀스타인 젖소의 원유내 acetone과 β-hydroxybutyrate acid 함량에 영향을 미치는 환경요인)

  • Cho, Kwang-Hyun;Cho, Chung-Il;Lee, Joon-Ho;Park, Kyung-Do
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.3
    • /
    • pp.687-693
    • /
    • 2015
  • Using 378,086 lactation records on dairy cattle, environmental factors influencing acetone and ${\beta}$-hydroxybutyrate acid contents in raw milk which are used as ketosis diagnosis indicator traits were analyzed in this experiment. Significance testing was conducted on farm, lactation stage, parity, milking time and month of age by traits. The results of this experiment indicated that there was a highly significant (p < 0.01) difference in all factors and lactation stage was the most significant factor. Linear regression coefficients of month of age on daily milk yields and acetone and ${\beta}$-hydroxybutyrate acid contents were all positive, while their quadratic linear regression coefficients were negative. Least square means for milk yield at second lactation stage (36~65 days) was 19.06kg which was higher than that of late lactation stage by 6.51kg. Least square means for acetone and ${\beta}$-hydroxybutyrate acid contents at the first lactation stage (5~35 days) were highest (0.1929mM/L and 0.0742mM/L, respectively), and there was a trend that they decreased as the milking progressed, but increased slightly at the late stage of milking. However, least square means for acetone and ${\beta}$-hydroxybutyrate acid contents at the first parity were 0.1414mM/L and 0.0522mM/L, respectively, which were higher than the average milk yield after the second parity. Least square means for acetone and ${\beta}$-hydroxybutyrate acid contents of PM milk yield (0.1372mM/L and 0.0534mM/L, respectively) were higher than those of AM milk yield collectively.

Two-Dimension Hydraulic Analysis in the Andong-Imha Linked Reservoir System (안동-임하호 연결 시스템의 2차원 수리해석)

  • Lee, Heung-Soo;Park, Hyung-Seok;Chung, Se-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.205-205
    • /
    • 2012
  • 국내에서 새로운 댐 저수지 건설을 통한 수자원의 안정적인 확보는 어려운 여건에 있다. 따라서 수자원의 효율적인 확보, 댐 하류하천의 수질 개선, 신규댐 건설 대체 효과를 기대하기 위해 기존 댐 저수지의 연계운영이 중요하게 인식되고 있다. 본 연구에서는 다수의 댐 저수지 수체를 연계하여 모델을 통해 해석하고자 안동-임하호를 연결한 2차원 모델(CE-QUAL-W2)을 구축하고, 2002년과 2006년 수문사상을 재현하였으며, 수리해석을 실시하였다. 안동호의 좌안인 임동면 마리와 임하호의 우안인 망천리를 연결하고, EL. 140 m 위치에 길이 2 km, 직경 5.5 m로 콘크리트 터널을 연결하는 것으로 가정하였다. 관내 바닥 마찰계수와 미소 마찰손실 값은 0.05를 입력하였다. 저수지 실측수위와 모의수위를 시계열로 비교한 결과, 2002년과 2006년 안동호와 임하호에서 여름철 유입량 증가에 따른 수위 상승을 잘 반영하였고, 결정계수값($R^2$)이 모두 0.9953 이상으로 나타나 모델은 두 저수지 물수지 계산에 있어서 높은 신뢰도를 보였다. 2006년을 대상으로 안동호와 임하호의 댐 앞에서 수심별 수온의 실측값과 모의값을 비교한 결과, 안동호는 4월부터 성층이 진행되어 5월에 수온약층이 EL. 130 m에 형성되었다. 7월 홍수가 중층 밀도류를 형성하여 수온 성층구조를 교란하였고, 기존의 수온약층이 EL. 120 m 로 하강하였으며, 표층 EL. 145 m에 새로운 수온약층이 형성되는 2단 성층 구조를 보였다. 여름철 동안 이러한 현상은 지속되었고, 10월부터 대기기온 강하와 함께 수직혼합이 시작되었다. 수온예측 오차는 AME $0.336{\sim}1.806^{\circ}C$, RMSE $0.415{\sim}2.271^{\circ}C$의 범위로 실측값을 잘 반영하는 것으로 나타났다. 임하호도 안동호와 유사한 경향을 보였고, 모델은 두 저수지에서 전 기간에 걸쳐 모두 안정적으로 저수지 수온 성층현상을 모의하였다. 2002년 수문사상에서 안동-임하 연계 운영시 안동호의 평균 수위는 1.38 m 상승하였고, 임하호는 3.75 m 낮아지는 것으로 모의되었다. 수위변동에 따른 유동 유량은 임하호에서 안동호로 3억 6천 4백만 톤, 안동호에서 임하호로 2억 9천 1백만 톤으로 임하호에서 안동호로 유동한 유량이 높게 나타났다. 유역면적에 비해 저수용량이 작은 임하호의 경우 두 저수지간 유량의 이동에 따라서 저수용량의 증가로 인한 홍수 저감 효과가 있을 것으로 판단된다. 반면, 안동-임하 연계 운영시 임하호의 차가운 물이 안동호로 유입되는 경우, 안동호의 수온 성층구조에 영향을 주었다. 안동호의 경우는 단독운영시보다 높은 위치에 수온약층(EL. 140 m)이 형성되었으며, 임하호는 반대로 저수위가 낮아지면서 단독운영시보다 수온약층의 위치가 약간 낮아졌다. 이러한 결과는 두 저수지 연결시 안동호의 탁수와 수질 환경에 변화가 있을 수 있음을 시사한다.

  • PDF

The Condensation Heat Transfer of R-22 and R-410A in an Inner Diameter Tube of 1.77 mm (내경 1.77 mm관내 R-22와 R-410A의 응축열전달)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.48-53
    • /
    • 2008
  • The condensation heat transfer coefficients of R-22 and R-410A in a small diameter tube were investigated. The main components of the refrigerant loop consist of a receiver, a variable-speed pump, a mass flowmeter, an evaporator (preheater), and a condenser (test section). The test section consists of smooth, horizontal copper tube of 3.38 mm outer diameter and 1.77 mm inner diameter. The refrigerant mass fluxes varied from 450 to $1050\;kg/(m^2s)$ and the average inlet and outlet qualities were 0.05 and 0.95. The main results were summarized as follows : the condensation heat transfer coefficient also increases with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

  • PDF

Development of Realtime Dam's Hydrologic Variables Prediction Model using Observed Data Assimilation and Reservoir Operation Techniques (관측자료 동화기법과 댐운영을 고려한 실시간 댐 수문량 예측모형 개발)

  • Lee, Byong Ju;Jung, Il-Won;Jung, Hyun-Sook;Bae, Deg Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.7
    • /
    • pp.755-765
    • /
    • 2013
  • This study developed a real-time dam's hydrologic variables prediction model (DHVPM) and evaluated its performance for simulating historical dam inflow and outflow in the Chungju dam basin. The DHVPM consists of the Sejong University River Forecast (SURF) model for hydrologic modeling and an autoreservoir operation method (Auto ROM) for dam operation. SURF model is continuous rainfall-runoff model with data assimilation using an ensemble Kalman filter technique. The four extreme events including the maximum inflow of each year for 2006~2009 were selected to examine the performance of DHVPM. The statistical criteria, the relative error in peak flow, root mean square error, and model efficiency, demonstrated that DHVPM with data assimilation can simulate more close to observed inflow than those with no data assimilation at both 1-hour lead time, except the relative error in peak flow in 2007. Especially, DHVPM with data assimilation until 10-hour lead time reduced the biases of inflow forecast attributed to observed precipitation error. In conclusion, DHVPM with data assimilation can be useful to improve the accuracy of inflow forecast in the basin where real-time observed inflow are available.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Modeling Paddlewheel-Driven Circulation in a Culture Pond (축제식 양식장에서 수차에 의한 순환 모델링)

  • KANG Yun Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.643-651
    • /
    • 2001
  • Paddlewheel-driven circulation in a culture pond has been simulated based on the depth integrated 2 dimensional hydrodynamic model. Acceleration by paddlewheel is expressed as shaft force divided by water mass discharged by paddlewheel blades. The model has been calibrated and applied to culture ponds as following steps:- i) The model predicted velocities at every 10 m along longitudinal direction from the paddlewheel. The model was calibrated comparing the results with the measured values at mass correction factor $\alpha$ and dimensionless eddy viscosity constant $\gamma$, respectively, in a range $15\~20$ and 6. ii) Wind shear stress was simulated under conditions of direction $0^{\circ}C,\;90^{\circ}C\;and\;180^{\circ}C$ and speed 0.0, 2.5, 5.0 and 7.5 m/s. Change rate of current speed was <$1\%$ at wind in parallel or opposite direction to the paddlewheel-driven jet flow, while $4\%$ at orthogonal angle. iii) The model was then applied to 2 culture ponds located at the Western coast of Korea. The measured and predicted currents for the ponds were compared using the regression analysis. Analysis of flow direction and speed showed correlation coefficients 0.8928 and 0.6782 in pond A, 0.8539 and 0.7071 in pond B, respectively. Hence, the model is concluded to accurately predict circulation driven by paddlewheel such that it can be a useful tool to provide pond management strategy relating to paddlewheel operation and water quality.

  • PDF

A Study on Verification of Delivery Ratio Methodology for Basic Plan at TPLMs(Total Pollutant Load Management System) (수질오염총량관리계획 수립을 위한 유달율 적용방안 검증 연구)

  • Lee, Sung Jun;Rhee, Han Pil;Park, Ji Hyung;Kim, Yong Seok;Hwang, Ha Sun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.714-722
    • /
    • 2017
  • The TPLMs is a system to manage the total amount of pollutants discharged from the watershed in order to achieve the target water quality of the river. In this process, the pollutant load can be classified into generation, discharge and delivery load. When using equation 2, the discharge coefficient should be 1. In case of using equation 3, it is considered that the discharge coefficient defined in the Technical Guideline should be applied. The delivery load is calculated as the product of the discharge load and the delivery ratio, and the delivery ratio is defined as the rate at which the pollutant discharged from the watershed reaches a specific point in the stream. In this study, the delivery ratio estimation method proposed by Hwang (2016) was applied to the Yonggang watershed in the Nakdong river. And the input data of QUALKO2 model was generated by using the estimated delivery ratio (equation 3) and the validation study was conducted by comparing with DRave (equation 2). As a result of the study, it is possible to use both the equation 2 and the equation 3, but it is necessary to change the methodology according to the application of the discharge coefficient.

Solute Transport Analysis in a Natural River using Convolutional Storage Model (합성곱 저장대모형을 이용한 하천에서의 용존물질 거동 해석)

  • Kim, Byunguk;Seo, Il Won;Gwon, Si-Yun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.200-200
    • /
    • 2021
  • 하천은 용수공급, 관개, 친수활동, 산업활동 등 인간의 활동에 중요한 역할을 한다. 이에 따라 수질관리는 필수적이며 유기물, 중금속, 화학물질 등의 용존물질들은 수질문제에 직접적으로 영향을 미친다. 따라서 하천에서의 용존물질의 혼합 거동을 파악하기 위한 연구가 지난 수십년간 이루어지고 있다. 하천 흐름에 따른 오염물질의 이동 및 확산 거동을 예측하기 위하여 1차원 추적모형이 활용되는데, 그 중 하천저장대 모형(Transient Storage Model, TSM)은 자연하천의 복잡하고 불규칙한 수리·지형적인 특성을 단순하게 반영할 수 있다는 장점때문에 가장 많이 사용된다. 하지만 TSM은 매개변수에 대한 의존성과 불확도가 크며, TSM의 저장대에서의 농도분포에 대한 지수함수형태의 모델링이 하상간극수역(Hyporheic zone)에서의 저장대 특성을 반영하기에 구조적으로 부정확하다는 단점이 제기되고 있다. 최근 이러한 TSM의 단점을 보완하고 하천에서의 저장대 메커니즘을 보다 정확하게 구현하고자 체류시간분포(residence time distribution)를 이용한 확률론적 저장대 모델링 프레임워크가 등장하고 있다. 본 연구에서는 본류대와 저장대에서의 오염물질의 체류시간분포를 분리하여 해석하고 이를 전달함수(transfer function)를 이용한 합성곱으로 결합한 형태의 프레임워크를 적용하여 모델링하였다. 상기의 모형을 검증하기 위하여 2019년 감천의 4.85km 구간에서 추적자 실험을 실시하였다. 실험 당시 유량은 12.9 m3/s로 풍수기에 해당되며 평균 유속은 약 0.6 m/s로 측정되었다. 모형의 매개변수는 추적자 실험으로부터 최적화 기법을 통해 역모델링기법으로 결정하였다. 제안된 모형에 의한 모의 결과를 추적자 실험에서의 농도측정자료와 비교한 결과, 평균 0.988의 결정계수를 보여 매우 높은 정확도를 보이고 있음을 알 수 있었다. 저장대특성을 나타내는 농도곡선의 꼬리부에 대하여 같은 조건에서 1차원 이송-분산(ADE) 모형, TSM의 모의결과와도 비교한 결과 본 모형은 추적자 실험 농도측정 결과와 평균 0.195의 오차율을 보이며, 이는 ADE 모형과 TSM의 오차율인 14.03과 1.866에 비해 매우 정확한 것으로 나타났다.

  • PDF

A Methodology for the Estimation of Design Flood of a Small Watershed (소하천유역(小河川流域)의 계획홍수량(計劃洪水量) 산정방법(算定方法)의 개발(開發))

  • Yoon, Yong Nam;Ahn, Tae Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.103-112
    • /
    • 1984
  • This study is an effort to develop a series of empirical procedure for the determination of design flood for a small watershed based on the unit hydrograph theory. It is shown that a flood discharge of a watershed with a specific return period can be expressed as a product of its watershed area, rainfall factor, runoff factor and flood peak reduction factor. Since the procedures for the determination of rainfall factor and runoff factor were already developed in the previous study (13) a series of step-by-step procedure is devised to empirically determine the flood peak reduction factor in the present study. Using the methodology developed herein the 50-year design flood, which is of concern in the drainage of agricultural lands, is estimated for a watershed on upper Kyungan River and compared with the design floods by the existing methods now in use. The flood peak reduction factor was correlated with the dimensionless parameter consisted of the rainfall duration divided by the basin lag time, which was computed from the derived unit hydrographs by the method of moment. The unit hydrographs of various durations were synthesized by the method of build up and S-curve. A multiple correlation was also made between the basin lag time and the physiographic parameters of the watershed, i.e., the stream length and the average stream slope.

  • PDF