• Title/Summary/Keyword: 평가 변수

Search Result 6,241, Processing Time 0.032 seconds

Differences in Patients' and Family Caregivers' Ratings of Cancer Pain (암환자와 그 가족간호자가 지각하는 환자의 통증강도 차이)

  • Kim, Hyun-Sook;Yu, Su-Jeong;Kwon, Shin-Young;Park, Yeon-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.1
    • /
    • pp.42-50
    • /
    • 2008
  • Purpose: Undertreatment of canter pain, especially due to the differences in the perception of pain between the patients and caregivers, is a well recognized problem. The purpose of this study were to determine if there exist differences in communication about pain intensity scores between patients and their family caregivers in Korea. Methods: A total of 127 patient-family caregiver dyads who have experienced canter pain participated in this study at a hospital in Seoul for six months. The data were obtained by fare to face interview with a structured questionnaire based on Brief Pain Inventory-Korean version and other previous researches. The clinical information for all patients was compiled by reviewing their medical records. Results: Patients' 'worst-pain for 24-hour' and 'right-now-pain' scores estimated by family caregivers were significantly higher than those by patient themselves. The degree of agreement between patients and family caregivers in the estimate of patients' 'worst-pain for 24-hour' intensity categories was 78.7% for 'severe pain', 40% for 'no pain', 27.5% for 'mild pain' and 22.9% for 'moderate pain'. In case of 'right-now-pain' intensity categories, the agreement was 50% for 'severe pain', 47.2% for mild pain, 46.3% for 'no pain', and 26.3% for 'moderate pain'. Conclusion: This study demonstrates that the degree of agreement between patients and family caregivers in the estimate of patients 'pain intensity categories was less than 50% except for 'severe pain'. The results indicate that Korean family caregivers tend to overestimate the canter pain intensity of their caring patients, especially, when a lancer patient has 'moderate' or 'mild pain'. Health Providers are advised to educate patient-family caregiver dyads to use a pain measurement scale to promote their agreement in pain Intensity stores. Further analyses and studies are needed to identify the factors and differences that influence their communication about pain intensity scores between patients and their family caregivers.

  • PDF

Effect of Glucose Control, SDSCA and Quality of Life of D-chiro-inositol(DCI) in patients with type 2 diabetes: A Path Analysis (제2형 당뇨병 환자의 D-chiro-inositol의 혈당강하 효과와 당뇨 자가관리 및 삶의 질: 경로분석)

  • Kang, Young Mi;Kim, Hyun Jin;Lee, Tae-Yong;Ku, Bon-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.243-253
    • /
    • 2018
  • This study aimed to investigate the effects of DCI on glucose control, quality of life(SF-36 Version 2.0, Korean) and SDSCA(Summary of Diabetes Self-Care Activities) in patients with type 2 diabetes mellitus. A randomized, double-blind, placebo-controlled study was performed on 46 patients with HbA1c 7.0% taking triple anti-diabetic drug regimen who visited the department of Endocrinology and Metabolism in Chungnam National University Hospital between March 2015 and May 2016. As a result, DCI treatment in the intervention group resulted in significantly reduced HbA1c levels $8.75{\pm}0.79%$(baseline), $8.36{\pm}1.03%$(after 12weeks), and $8.65{\pm}0.81%$(after 24weeks). However, patients in the control group did not show any significant change. Interestingly, both DCI treatment group and the control group significantly showed improvements in SDSCA. Participants in the intervention group showed a small yet significant improvement in their only fasting blood glucose test in SDSCA and revealed significant increase in the quantitative levels of quality of life, from $73.05{\pm}16.85$ to $82.74{\pm}10.68$. By using pathway analysis, improvement of SDSCA scores(${\beta}=-0.505$, t=-2.743) was the most influential factor to the fasting blood glucose. The quality of life of patients with type 2 diabetes mellitus was affected by changes of SDSCA scores(${\beta}=0.411$, t=2.024) and fasting c-peptide(${\beta}=-0.445$, t=-2.668) in DCI treatment group. In conclusion, treatment of DCI effectively improved glucose control in patients with type 2 DM(HbA1c level>7.0%) after 12 weeks of treatment, although it had no impact on glucose control after 24 weeks of treatment. Improved glucose control may encourage diabetic patients to conduct self-care activities and improve the quality of life. Based on the present study, we suggest that diabetes self-management, as well as consideration of comprehensive laboratory findings, may be important factor in regulating the quality of life in type 2 DM patients.

A Study on Trust and Commitment between Buyer and Supplier of Industrial Parts, and Their Usage of Information Technology (산업재 부품 구매자와 공급자의 신뢰와 몰입, 그리고 정보기술의 이용에 관한 연구)

  • Kim, Jong-Hun;Yun, Hui-Taek
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2006.08a
    • /
    • pp.47-68
    • /
    • 2006
  • This study aims to determine the association structure of the behavioral relationship variables, such as trust, commitment, cooperation, communication and coercive power, in the relationship between the buyers and suppliers of industrial parts. It also investigates the impact of the use of IT technologies on the relationships quality. Data was collected from 216 part suppliers of machinery, electronics and automobiles located in Incheon. Data supported all of the proposed hypotheses. First, it was confirmed that parts suppliers' trust in buyers leads to the commitment into relationships with buyers. Second, cooperation and communication showed a positive influence on parts suppliers' trust in buyers, and coercive power gave a negative influence on trust. Third, the use of IT technologies like Internet and E-Mail between parts suppliers and buyers was verified to have generally a positive influence on the quality of relationships. At the same time, cooperation and communication were confirmed to have a positive influence on each other, and cooperation and coercive power as well as communication and coercive power were confirmed to have negative influence on each other. This study is a pioneering attempt to examine the relationships between suppliers and buyers of industrial parts, and the influence IT technologies on the relationship quality. Also, the findings will be practically much helpful to find how to reinforce the relationships between parts suppliers and buyers.

  • PDF

Leaching and mobility prediction of butachlor, ethoprophos, iprobenfos, isoprothiolane and procymidone in soils (Butachlor, ethoprophos, iprobenfos, isoprothiolane 및 procymidone의 토양 중 용탈과 이동성 예측)

  • Kim, Chan-Sub;Park, Kyung-Hun;Kim, Jin-Bae;Choi, Ju-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.6 no.4
    • /
    • pp.300-308
    • /
    • 2002
  • This study was conducted to investigate the downward mobility of pesticides using soil colunms and to compare the experimental results with predicted values from Convective mobility test model. Five pesticides including ethoprophos, procymidone, iprobenfos, isoprothiolane, and butachlor were subjected to soil column leaching test for three types of cultivation soils. The concentrations of ethoprophos, iprobenfos, procymidone, isoprothiolane and butachlor leached from soil column of 30 cm depth ranged $0.74{\sim}3.61mg/mL,\;0.36{\sim}1.67mg/L,\;0.16{\sim}0.84mg/L,\;0.16{\sim}0.67mg/L$ and lower than 0.15 mg/L, respectively. Elution volume to reach the peak of ethoprophos, iprobenfos, procymidone, isoprothiolane and butachlor in the leachate ranged $2{\sim}4PV,\;3{\sim}10PV,\;5{\sim}13PV,\;4{\sim}14PV\;and\;19{\sim}61PV$, respectively. Convection times predicted by Convective mobility test model at standard conditions were $9{\sim}18$ days for ethoprophos, $17{\sim}35$ days for iprobenfos, $24{\sim}54$ days for isoprothiolane, $21{\sim}65$ days for procymidone and $105{\sim}279$ days for butachlor. Based on these convection times, ethoprophos was classified as mobile or most mobile, isoprothiolane and procymidone as moderately mobile or mobile and butachlor as slightly mobile. On the same conditions, convection times from the model were coincided with those from soil column test in most of the soil-pesticide combinations applied. Therefore, Convective mobility test model could be applied to predict convection times of pesticides.

A Comparative Study of Internet Addiction among Middle and High School Students in Seoul, Cheonan, and Rural Area (서울, 천안, 농촌지역 중 고교 학생들의 인터넷 중독에 대한 비교 연구)

  • Lee, Seok-Bum;Lee, Kyung-Kyu;Paik, Ki-Chung;Kim, Hyun-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.12 no.2
    • /
    • pp.145-156
    • /
    • 2004
  • Objectives : Internet addiction is a newly appeared addictive phenomenon that is defined as 'difficulty in real life due to internet over-use', 'excessive time spent on the internet or replacement of genuine real relationships with superficial virtual ones' or 'weakness in self-control about internet use and if discontinued, fallen in psychological confusion and anergic state'. This study was aimed to compare the internet addiction rate, demographic factors, computer using patterns, anxiety, depression, and internet self-efficacy and outcome expectancy between Korean middle and high school students in three areas - Seoul, Cheonan, and Rural areas - that were different in economic, cultural, and geographic state. Methods : Subjects are consisted of middle and high school students in Seoul, Chunan, and Rural areas(N=1718). Self-rating questionnaire included demographic data, Korean Spielberger State-Trait Anxiety Inventory, Korean Self-Rating Depression Scale(SDS), questions for internet-using pattern, Korean version of Internet Addiction Scale invented by K. S. Young, Internet Self-efficacy and Out-come Expectancy Scale. Results: In this study, prevalence of internet addiction was 2.9%. There was no significant difference found in prevalence of internet addiction among three areas. In all subjects, there were significant differences in anxiety, depression, internet self-efficacy and outcome expectancy, leisure style, places of internet use, internet connecting method, and insight on internee addiction. But, in addicted group, there was no significant difference among three areas. Conclusion: This study suggested that the difference in economic, cultural, and geographic state was not related to prevalence of internet addiction. Although there were significant differences in anxiety, depression, self-efficacy associated with internee use, leisure style, places of internet use, internet connecting method, insight on internet addiction among three areas, there were no significant difference in addicted group among three areas. So, we concluded that the difference in economic, cultural, and geographic state did not influence the prevalence of internet addiction, and despite the difference in economic, cultural, and geographic state, people in three areas were equally influenced by internet addiction.

  • PDF

Association between Type D Personality and the Somatic Symptom Complaints in Depressive Patients (우울증 환자에서 D형 인격과 신체 증상 호소와의 관련성)

  • Park, Wu-Ri;Jeong, Seong-Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.21 no.1
    • /
    • pp.18-26
    • /
    • 2013
  • Objectives : Type D personality was originally introduced to study the role of personality in predicting outcomes of heart disease. However, researches showed that other medical conditions are also affected by this personality. The purpose of this study was to evaluate the relationship between type D personality and somatic symptom complaints in depressive patients. Methods : Eighty-two individuals diagnosed with depressive disorder were included. Type D personality was measured with DS14. Patient Health Questionnaire(PHQ) 9 and 15 were used to measure depression severity and somatization tendencies. For alexithymia, TAS-20 was used. Student T-test and linear regression analysis were performed. The best regression model was determined by stepwise variable selection. Results : More than half of the subjects(56%) complained at least medium degree somatic symptoms according to PHQ-15 criteria. Two-thirds of the subjects were classified as Type D personality(63.4%). The mean PHQ-15 score of the Type D individuals was significantly higher than the remaining subjects(PHQ-15 mean=12.7, $p=8.2{\times}10^{-7}$). The best regression model included age, PHQ-9 score and NA subscale score as predictor variables. Among these, only the coefficients of age($p=1.5{\times}10^{-3}$) and NA score($p=1.5{\times}10^{-7}$) were found to be statistically significant. Conclusions : The result showed that Type D personality was one of the strong predictors of somatic complaints among depressive individuals. The finding that negative affectivity rather than social inhibition was more closely associated with somatization tendencies does not fully agree with the traditional explanation that inability to express negative emotion predispose the individuals to somatic symptoms. The finding that alexithymia was not shown to be a significant predictors also substantiated this discrepancy. However, it might be possible that the high correlation between NA and SI subscore(r=0.65) and between NA and TAS-20 score(r=0.44) hid the additional effects of social inhibition and alexithymia. Further research with a larger sample would be needed to investigate the effects of the latter two components over and above the effect of negative affectivity on the somatic complaints in depressive patients.

  • PDF

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

Carbon Storage and Uptake by Deciduous Tree Species for Urban Landscape (도시 낙엽성 조경수종의 탄소저장 및 흡수)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.160-168
    • /
    • 2012
  • This study generated regression models to estimate the carbon storage and uptake from the urban deciduous landscape trees through a direct harvesting method, and established essential information to quantify carbon reduction from urban greenspace. Tree species for the study included Acer palmatum, Zelkova serrata, Prunus yedoensis, and Ginkgo biloba, which are usually planted as urban landscape trees. Tree individuals for each species were sampled reflecting various diameter sizes at a given interval. The study measured biomass for each part including the roots of sample trees to compute the total carbon storage per tree. Annual carbon uptake per tree was quantified by analyzing radial growth rates of stem samples at breast height. The study then derived a regression model easily applicable in estimating carbon storage and uptake per tree for the 4 species by using diameter at breast height(dbh) as an independent variable. All the regression models showed high fitness with $r^2$ values of 0.94~0.99. Carbon storage and uptake per tree and their differences between diameter classes increased as the diameter sizes got larger. The carbon storage and uptake tended to be greatest with Zelkova serrata in the same diameter sizes, followed by Prunus yedoensis and Ginkgo biloba in order. A Zelkova serrata tree with 15cm in dbh stored about 54kg of carbon and annually sequestered 7 kg, based on a regression model for the species. The study has broken new grounds to overcome limitations of the past studies which substituted, due to a difficulty in direct cutting and root digging of urban landscape trees, coefficients from the forest trees such as biomass expansion factors, ratios of below ground/above ground biomass, and diameter growth rates. Study results can be useful as a tool or skill to evaluate carbon reduction by landscape trees in urban greenspace projects of the government.

The Study of Operating Conditions by Establishing Density Currents Generator for Improving of Water Quality on Lake Water - With Focus on DO and Water Temperature - (호소수의 수질개선을 위한 DCG 설치시 운전조건에 관한 연구 - DO와 수온을 중심으로 -)

  • Lee, Young-Shin;Han, Kyung-Hee;Kim, Young-Kyu;An, Hyung-Chul;Shin, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.286-294
    • /
    • 2014
  • The purpose of this study is to investigate the effects of applying density current generator (hereafter referred to as DCG to large lakes on the operating conditions of DCG, de-stratification, water quality improvement and inhibition of algae occurrence. As a result of a survey conducted to derive the optimum operating parameters of DCG in a condition to minimize eco-toxicity, the following conclusions were obtained. During the survey period, a marked stratification appeared in September to October 2011 and May 2012. At this time, the average depth of water to form thermocline was found to be $5{\pm}2$ m, so the location of discharge port for the operation of DCG was determined to be about 5 m below from the surface. To minimize the adverse effects of benthos and obtain the effect of water mixture at the time of water circulation, the mixing ratio of surface water and deep water was designed to be 3:1 by means of ecotoxicological assessment on the DCG operating characteristics. To select the appropriate operating hours for DCG, DCG was operated by 12 hr, 24 hr, 36 hr and 48 hr. As its result, the formation of thermocline did not occur during the operation of 36 hr. Also, It was effected that start reoperating from 3rd day after stop 2days under the condition of operated during 36 hr with calculated power consumption. Under the above conditions, the results of DO and water temperature analysis during the operation of DCG showed that the stratification, which was distinct previously, appeared to be weak, and relatively lower levels than those before operation were found as a result of water quality analysis on COD and chlorophyll-a, which leads to the conclusion that the water body is maintained at a stable condition due to the circulation of water by the occurrence of density current resulting from the operation of DCG.

Study of the CatcherTM Couch's Usefulness (토모치료기 CatcherTM Couch의 유용성에 대한 고찰)

  • Um, Ki Cheon;Lee, Chung Hwan;Jeon, Soo Dong;Song, Heung Kwon;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.65-74
    • /
    • 2019
  • Purpose: Recently, A Catcher was added to prevent sagging in Radixact® X9. In this study, We quantitatively compared general couch of Tomo-HDA® with catcher couch of Radixact® X9 using the human phantom and evaluated usefulness of catcher. Materials and methods: We used rando phantom for phantom study and set the each iso-center of head and neck region and Pelvis region for region parameter. Furthermore, We used hand made low melting point alloys for weight parameter. MVCT(Mega Voltage Computed Tomography) images were acquired for vertical error and rotation(pitch) error measurement increasing weight(A: 15kg, A+B: 30kg, A+B+C: 45kg). We selected 120 patients who has been treated using Tomotherpy machine for patient study. 60 patients has been treated in Tomo-HDA® and the other 60 patients treated in Radixact® X9. In the patient study methods, vertical error and rotation(pitch) error was measured for mean value calculation using MVCT images acquired on first day of radiation therapy. Result: Result of phantom study, Vertical error and rotation(pitch) error was increased proportionally increased as the weight increases in general couch of Tomo-HDA®. each maximum value was 7.52mm, 0.38° in head and neck region and 11.94mm, 0.92° in pelvis region. However, We could confirm that there was stable error range(0.02~0.1mm, 0~0.04°) in Catcher couch of Radixact®. Result of patient study, The head and neck region was measured 4.79mm 0.33° lower, and the pelvis region was measured 7.66mm, 0.22° lower in Catcher couch of Radixact® X9. Conclusion: In this study, Vertical error and rotation(pitch) error was proportionally increased as the weight increases in general couch of Tomo-HDA®. Especially, The pelvis region error was more increased than the head and neck region error. However, Vertical error and rotation(pitch) error was regularly generated regardless of weight or regions in CatcherTM couch of Radixact® X9 that this study's purpose. In conclusion, CatcherTM couch of Radixact® X9 can minimize mechanical error that couch sagging. Furthermore, The pelvis region is more efficiency than head and neck region. In radiation therapy using Tomotherapy machine, it is regarded that may contribute to minimizing unadjusted pitch error due to characters of Tomotherapy.