• Title/Summary/Keyword: 평가장치

Search Result 4,655, Processing Time 0.035 seconds

Investigation into influence of sound absorption block on interior noise of high speed train in tunnel (터널 내부 도상 블록형 흡음재의 고속철도차량 내부 소음에 미치는 영향에 대한 고찰)

  • Lee, Sang-heon;Cheong, Cheolung;Lee, Song-June;Kim, Jae-Hwan;Son, Dong-Gi;Sim, Gyu-Cheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.223-231
    • /
    • 2018
  • Recently, due to various environmental problems, blast tracks in tunnel are replaced with concrete tracks, but they have more adverse effects on noise than blast tracks so that additional noise measures are needed. Among these measures, sound-absorbing blocks start to be used due to its easy and quick installation. However, the performance of sound absorption blocks need to be verified under real environmental and operational conditions. In this paper, interior noise levels in KTX train cruising in Dalseong tunnel are measured before and after the installation of sound-absorbing blocks and the measured data are analyzed and compared. Additionally, noise reduction are estimated by modeling the high speed train, the tunnel and absorption blocks. Measurement devices and methods are used according to ISO 3381 and the equivalent sound pressure levels during the cruising time inside the tunnel are computed. In addition to overall SPLs(Sound Pressure Levels), 1/3-octave-band levels are also analyzed to account for the frequency characteristics of sound absorption and equipment noise in a cabin. In addition, to consider the effects of train cruising speeds and environmental conditions on the measurements, the measured data are corrected by using those measured during the train-passing through the tunnels located before and behind the Dalseong tunnel. Analysis of measured results showed that the maximum noise reduction of 6.8 dB (A) can be achieved for the local region where the sound-absorbing blocks are installed. Finally, through the comparison of predicted 1/3-octave band SPLs for the KTX interior noise with the measurements, the understanding of noise reduction mechanism due to sound-absorbing blocks is enhanced.

DNA damages with Fpg/Endo Ⅲ FLARE Assay in cynomolgus monkeys exposed to stainless steel welding fume (용접흄 흡입노출 영장류에서 Fpg/Endo Ⅲ FLARE Assay를 이용한 DNA 손상 및 회복)

  • Rim, Kyung Taek;Kim, Soo Jin;Chung, Yong Hyun;Kim, Hyeon Yeong;Maeng, Seung Hee;Yu, Il Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.272-281
    • /
    • 2007
  • 선박제조업을 비롯한 운송업 및 건축업 등의 다양한 분야에서 용접기술이 이용되어 옴에 따라 용접근로자들에 대한 산업보건학적 관심이 높아지고 있다. 노출정도가 다양하기는 하지만 용접흄은 6가 크롬을 비롯한 금속화합물과 유해가스, 화학물질 등을 복합적으로 포함하고 있는 스테인레스 스틸 용접흄에 대한 유전독성영향을 평가하기 위하여 흡입챔버를 이용, 실험동물인 영장류에 스테인레스 스틸 용접흄을 노출시키고 혈액 내 lymphocytes에 생성된 용접흄 노출농도 및 시간별 DNA 손상정도 및 그 회복효소를 측정함으로써, 유해성이 완전하게 확인되지 않은 용접흄에 노출되어 나타날 수 있는 암을 비롯한 심각한 건강영향을 예방하기 위한 각 지표들을 찾아 그 유용성을 비교하고자 하였다. 영장류를 노출시키기 위해 robotic arm을 장치한 영장류 흡입노출 시스템을 개발하였으며, 이 노출 시스템을 이용하여 수컷 영장류 6마리에 대해 용접흄 노출시험을 실시하였는데 실험군은 대조군 2, 저농도 ($31mg/m^3$) 노출군 2, 고농도 ($63mg/m^3$) 노출군 2마리로 구성하였고, 1일 2시간씩 일주일에 5일 동안 용접흄에 노출시켰다. 노출 농도는 지속적으로 모니터링 하였고, 노출과정 중에 영장류의 혈액을 채취하여 lymphocytes를 분리, 단세포 DNA 손상을 선별하기 위해 DNA 손상회복 효소인 E. coli formamidopyrimidine-DNA glycosylase (Fpg)와 endonuclease Ⅲ (Thymine Glycol-DNA glycosylase) 투여와 Comet asaay (single cell gel electrophoresis, 단세포겔전기영동기법)를 결합시켜 이용하는 Fpg/Endo III FLARE 분석법을 사용하였다. Fpg enzyme에 의한 olive tail moment값의 변화는 16주 노출군부터 노출부검(34주)군 까지 노출농도가 높아짐에 따른 olive tail moment 기하평균 값의 양 반응관계를 보기는 어렵지만, 고농도군의 경우 27주 노출군에서 가장 높은 olive tail moment 값을 보이고 이후 차츰 감소하였다. 한편 16주에서 22주까지의 노출기간에서는 대조군에 비해 노출군에서 DNA손상정도(olive tail moment값)는 모두 유의하게 높았으나, 6, 12, 18, 25, 31, 33, 35주간 노출하였을 때는 다른 결과를 보였다. 각 실험군의 Fpg enzyme에 의한 tail length값의 분포를 살펴볼 때, 저농도군 및 고농도군에서 27주간 노출하였을 때 가장 높은 tail length 값을 보이고 이후 차츰 감소하는 경향을 보였다. 또한 16, 22주간 노출하였을 때 대조군에 비해 노출군에서 tail length 값이 유의하게 높았으나, 20주간에서만 양 반응관계가 관찰되었고, 다른 주간에서는 양 반응 및 기간 반응관계를 나타내지는 않았다. Endo III enzyme에 의한 olive tail moment값의 변화는 기간별 노출군에서 대조군에 비해 높은 DNA손상정도(olive tail moment값)를 나타내는 결과들이 있었지만, 10, 12, 16, 22, 25, 31주간 노출하였을 때 등 상당수 노출기간에서 반응관계를 나타내지는 않았다. 각 실험군의 Endo III enzyme에 의한 tail length값의 분포를 살펴볼 때, 18, 20, 27, 33주간 노출하였을 때 대조군에 비해 노출군에서 tail length 값이 조금 높았지만, 양 반응 및 기간 반응관계를 보이지 않았고 수치의 크기가 불규칙하게 변화하였다. 즉, DNA에 있어 산화된 pyrimidine을 형성하여 손상된 부위의 염기를 제거함으로써 AP site (abasic site)를 만들고 이들이 Comet assay를 통해 break로 전환된 것을 포함한 DNA손상을 측정하기 위하여 endonuclease III (Endo III)를 첨가시킨 Endo III FLARE 분석법을 실시한 결과, 본 연구에서 나타난 결과는 용접흄 노출 영장류에서 Olive tail moment 및 tail length 공히 노출량 및 노출기간 반응관계를 볼 수 없었다. Endo III FLARE 분석법을 통한 산화적 DNA 손상지표는 영장류에 적용하기에는 적응반응현상으로 대조군과 유의한 차이도 관찰할 수 없었고 더욱이 역으로 대조군에서의 자연발생적 수치가 더 높아질 수 있어 용접흄 노출 영장류의 모니터링 지표로 사용하기에는 제한점이 있었다.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

A Study on the Competencies of Automotive Professional Engineers in Korea (자동차 신제품개발 관련 차량기술사의 전문적 업무역량 분석)

  • Kim, Joo-Young;Lim, Se-Yung
    • 대한공업교육학회지
    • /
    • v.33 no.2
    • /
    • pp.192-217
    • /
    • 2008
  • This paper investigated the perceived criticalities and patterns of Korean Professional Engineer's competency regarding the working activities of automative product development, manufacturing, etc by using questionnaires responded to the survey which were applied to the automotive professors, experts and professional engineers (vocational parties) by e/mail, etc. This research investigated the following questions: First, what are the characteristic patterns, relevancy and perceived criticalities of Korean Professional Engineer's competencies? Second, What are the ranked priority of the Korean Professional Engineers' competencies? Are there any differency for each item, sub group of job, intelectual criterior of the competencies between relevancy and perceived criticalities according to the types of vocational parties, etc.? Accoring to the results; first, Professor group showed highest points among 3 groups per each item of the competencies by vocational parties Second, Chassis design group ranked top position among the 8 sub groups by vocational parties and, third, Problem Solving Knowledge ranked highest points than any others. Korean Professional Engineers are found to be positioned as key members, leaders and managers on surveying market, product planning, designing product & components, developing component parts, establishing shop with production equipment, managing quality control & material handling, organizing relevant meetings, developing human resources by training and learning, to back up finance with law matters, cooperating with concerned parties to achieve organizational goals, and to coordinate projects. etc, identifying ethical issues and business skills in order to survive and win to be competitive in various kinds of the automotive industry battle fields.

The comparison of the frictional force by the type and angle of orthodontic bracket and the coated or non-coated feature of archwire (교정용 브라켓의 종류와 각도, 호선의 코팅 여부에 따른 마찰력의 비교)

  • Jang, Tae-Ho;Kim, Sang-Cheol;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.399-410
    • /
    • 2011
  • Objective: The purpose of this study was to evaluate the difference in frictional resistance among metal, ceramic, self-ligation brackets and coated or non-coated Ni-Ti archwires at various bracket-archwire angulations during the sliding movement of an orthodontic archwire, using an orthodontic sliding simulation device. Methods: Four types of bracket (Micro-arch Perpect Clear2 Clippy-C and Damon3 and 5 types of orthodontic archwire (0.014", 0.016", and 0.016" ${\times}$ 0.022" inch coated Ni-Ti, and 0.016" and 0.016" ${\times}$ 0.022" inch Ni-Ti) were used. Further, the bracket- archwire angles were set at 4 different angulations: $0^{\circ}$, $3^{\circ}$, $6^{\circ}$, and $9^{\circ}$. Results: The frictions from all the experimental groups were found to be significantly increased in order of self-ligation brackets, Micro-arch and Perpect Clear2 ($p$ < 0.001). The presence of a coat had no effect on the friction of the same sized archwires at $0^{\circ}$ and $3^{\circ}$ bracket-archwire angles ($p$ < 0.001). Coated archwires had significantly higher frictions than the same sized non-coated archwires at $6^{\circ}$ and $9^{\circ}$ bracket-archwire angles ($p$ < 0.001). The frictions increased significantly as the bracket-archwire angles were increased ($p$ < 0.001). Conclusions: The use of self-ligation brackets will be beneficial in clinical situations where a low frictional force is required. Further, in cases where crowding is not severe, the use of coated archwires should not cause problems. However, more additional explanation is required considering the fact that the damage of coated archwire and exposure of the metal portion in case of binding and notching and the effects of saliva were not taken into account.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

Estimation of Soil CO2 Efflux from an Apple Orchard (사과 과수원에서의 토양 CO2 발생량 평가)

  • Lee, Jae-Man;Kim, Seung-Heui;Park, Hee-Seung;Seo, Hyeong-Ho;Yun, Seok-Kyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.2
    • /
    • pp.52-60
    • /
    • 2009
  • This study was conducted to quantify the soil respiratory $CO_2$ emission (SR) in an apple orchard and to determine its relationship with key environmental factors such as air temperature, soil temperature and soil moisture content. Experiment was made over the period from 23 April 2007 to 31 March 2008 in 'Fuji' apple orchard of National Institute of Horticultural and Herbal Science in Suwon, Gyeonggi-do, Korea. The SR was measured by using the automatic opening/closing chamber system based on a closed method. Diurnal variations in SR showed an increase around 0700 hours with increasing soil temperature, its peak between 1400 and 1500 hours, and then a gradual decrease thereafter. Daily variations in SR depended largely on soil and air temperatures over the year, ranging from 0.8 to 13.7 g $CO_2$ $m^{-2}d^{-1}$. During the rainy spell in summer (July$\sim$Autumn) with higher temperature and more precipitation, the SR was lower than that in the spring (May$\sim$June) with moderate temperature. The SR showed a significant exponential relationship with soil temperature ($r^2=0.800$) and air temperature ($r^2=0.805$), but not with soil moisture content ($r^2=0.160$). The $Q_{10}$ values of SR with annual soil temperature and air temperature were 2.0 and 1.9, respectively. The annually integrated SR was 19.6 ton $CO_2$ $ha^{-1}$.

Perspective on Rapid and Selective Method for Detecting Microbiology in Dairy Industry: A Review (낙농산업에 필요한 미생물 검사방법과 전망: 총설)

  • Chon, Jung-Whan;Kim, Hyun-Sook;Kim, Hong-Seok;Kim, Dong-Hyeon;Song, Kwang-Young;Yim, Jin-Hyuk;Choi, Dasom;Lim, Jong-Soo;Jeong, Dong-Gwan;Kim, Soo-Ki;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.119-127
    • /
    • 2015
  • To date, detection of microbial populations in dairy products has been performed using culture media, which is a time-consuming and laborious method. The recently developed chromogenic media could be more rapid and specific than classical culture media. However, the newly developed molecular-based technology can detect microbial populations with greater rapidity and sensitivity than the classical method involving culture media and chromogenic media. This molecular-based technology could provide various options for monitoring the characterization of different states of bacteria and cells. Thus, it could help upgrade the processing system of the dairy industry so as to maintain the safety and quality of dairy foods. Among the various newly developed molecular-based technologies, flow cytometry can potentially be used for monitoring microbiological populations in the dairy industry if official international standards are available for this purpose. When omics technology would have biomarker identification, it could be regarded as the rapid and sensitive analytical methods. Methods based on PCR, which has become a basic technique in microbiological research, can be developed and validated as alternative methods for quantification of dairy microorganisms. This review discusses methods for monitoring microbiological populations in dairy foods and the limitations of these studies, as well as the need for further research on such methods in the dairy industry.

  • PDF