• Title/Summary/Keyword: 평가규칙

Search Result 1,024, Processing Time 0.044 seconds

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Associations of Metabolic Syndrome with Glaucoma in Korean - Based on the Korean National Health and Nutrition Examination Survey 2005, 2007-9, 2010 (한국인의 대사증후군과 녹내장 간의 상관관계 -2005, 2007-9, 2010국민건강영양조사 이용)

  • Park, Sang Shin;Kim, Taehun;Pak, Yun-Suk;Lee, Sang-Yoon;Lee, Hae Jung;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.241-247
    • /
    • 2012
  • Purpose: This study was conducted to assess the association of metabolic syndrome and its components with glaucoma. Methods: We investigated the associations of metabolic syndrome and its components (abdominal obesity, impaired fasting glucose, high blood pressure, and dyslipidemia) with glaucoma using data from 19,162 adults aged 40 or above among the Korean National Health and Nutrition Examination Survey III (2005), IV (2007-9), V (2010). The logistic regression analysis was used for assessing those associations after adjusting demographic, lifestyle, and social economic status and for assessing the association of metabolic medication intakes with glaucoma risks. Results: After adjusting for age and sex, the risk of glaucoma was significantly higher in the subjects with impaired fasting glucose(Odds Ratio (95% confidence interval): 1.78 (1.25, 2.53)) and metabolic syndrome (1.45 (1.01, 2.08)) than subjects without those. These associations increased when additional adjusting for smoking, alcohol use, regular physical activity, income, education status(impaired fasting glucose: 1.89 (1.29, 2.77), metabolic syndrome: 1.52 (1.03, 2.25)). Glaucoma prevalence was borderline significantly increased according to the number of metabolic abnormalities(age and sex adjusted p for trend = 0.055). Use of antihypertensive medication was significantly associated with the risk of glaucoma. Conclusions: Metabolic syndrome and impaired fasting glucose were significantly associated with the increased glaucoma risk. Use of antihypertensive medication was also significantly associated with the increased glaucoma risk.

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.

Development and Utility Evaluation of Portable Respiration Training Device for Image-guided Stereotactic Body Radiation Therapy (SBRT) (영상유도 체부정위방사선 치료시 호흡동조를 위한 휴대형 호흡연습장치의 개발 및 유용성 평가)

  • Hwang, Seon Bung;Park, Mun Kyu;Park, Seung Woo;Cho, Yu Ra;Lee, Dong Han;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.264-270
    • /
    • 2014
  • This study developed a portable respiratory training device to improve breathing stability, which is an important element in using the CyberKnife Synchrony respiratory tracking device, one of the typical Stereotactic Radiation Therapy (SRT) devices. It produced an interface for users to be able to select one of two displays, a graph type and a bar type, supported an auditory system that helps them expect next respiration by improving a sense of rhythm of their respiratory period, and provided comfortable respiratory inducement. By targeting 5 applicants and applying individual respiratory period detected through a self-developed program, it acquired signal data of 'guide respiration' that induces breathing through signal data gained from 'free respiration' and an auditory system, and evaluated the usability by comparing deviation average values of respiratory period and respiratory amplitude. It could be identified that respiratory period decreased $55.74{\pm}0.14%$ compared to free respiration, and respiratory amplitude decreased $28.12{\pm}0.10%$ compared to free respiration, which confirmed the consistency and stability of respiratory. SBRT, developed based on these results, using the portable respiratory training device, for liver cancer or lung cancer, is evaluated to be able to help reduce delayed treatment time due to respiratory instability and improve treatment accuracy, and if it could be applied to developing respiratory training applications targeting an android-based portable device in the future, even use convenience and economic efficiency are expected.

STANDARDIZATION OF WORD/NONWORD READING TEST AND LETTER-SYMBOL DISCRIMINATION TASK FOR THE DIAGNOSIS OF DEVELOPMENTAL READING DISABILITY (발달성 읽기 장애 진단을 위한 단어/비단어 읽기 검사와 글자기호감별검사의 표준화 연구)

  • Cho, Soo-Churl;Lee, Jung-Bun;Chungh, Dong-Seon;Shin, Sung-Woong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.81-94
    • /
    • 2003
  • Objectives:Developmental reading disorder is a condition which manifests significant developmenttal delay in reading ability or persistent errors. About 3-7% of school-age children have this condition. The purpose of the present study was to validate the diagnostic values of Word/Nonword Reading Test and Letter-Symbol Discrimination Task for the purpose of overcoming the caveats of Basic Learning Skills Test. Methods:Sixty-three reading-disordered patients(mean age 10.48 years old) and sex, age-matched 77 normal children(mean age 10.33 years old) were selected by clinical evaluation and DSM-IV criteria. Reading I and II of Basic Learning Skills Test, Word/Nonword Reading Test, and Letter-Symbol Discrimination Task were carried out to them. Word/Nonword Reading Test:One hundred usual highfrequency words and one hundred meaningless nonwords were presented to the subjects within 1.2 and 2.4 seconds, respectively. Through these results, automatized phonological processing ability and conscious letter-sound matching ability were estimated. Letter-Symbol Discrimination Task:mirror image letters which reading-disordered patients are apt to confuse were used. Reliability, concurrent validity, construct validity, and discriminant validity tests were conducted. Results:Word/Nonword Reading Test:the reliability(alpha) was 0.96, and concurrent validity with Basic Learning Skills test was 0.94. The patients with developmental reading disorders differed significantly from normal children in Word/Nonword Reading Test performances. Through discriminant analysis, 83.0% of original cases were correctly classified by this test. Letter-Symbol Discrimination Task:the reliability(alpha) was 0.86, and concurrent validity with Basic Learning Skills test was 0.86. There were significant differences in scores between the patients and normal children. Factor analysis revealed that this test were composed of saccadic mirror image processing, global accuracy, mirror image processing deficit, static image processing, global vigilance deficit, and inattention-impulsivity factors. By discriminant analysis, 87.3% of the patients and normal children were correctly classified. Conclusion:The patients with developmental reading disorders had deficits in automatized visuallexical route, morpheme-phoneme conversion mechanism, and visual information processing. These deficits were reliably and validly evaluated by Word/Nonword Reading Test and Letter-Symbol Discrimination Task.

  • PDF

Evaluation of Oil Spill Detection Models by Oil Spill Distribution Characteristics and CNN Architectures Using Sentinel-1 SAR data (Sentienl-1 SAR 영상을 활용한 유류 분포특성과 CNN 구조에 따른 유류오염 탐지모델 성능 평가)

  • Park, Soyeon;Ahn, Myoung-Hwan;Li, Chenglei;Kim, Junwoo;Jeon, Hyungyun;Kim, Duk-jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_3
    • /
    • pp.1475-1490
    • /
    • 2021
  • Detecting oil spill area using statistical characteristics of SAR images has limitations in that classification algorithm is complicated and is greatly affected by outliers. To overcome these limitations, studies using neural networks to classify oil spills are recently investigated. However, the studies to evaluate whether the performance of model shows a consistent detection performance for various oil spill cases were insufficient. Therefore, in this study, two CNNs (Convolutional Neural Networks) with basic structures(Simple CNN and U-net) were used to discover whether there is a difference in detection performance according to the structure of CNN and distribution characteristics of oil spill. As a result, through the method proposed in this study, the Simple CNN with contracting path only detected oil spill with an F1 score of 86.24% and U-net, which has both contracting and expansive path showed an F1 score of 91.44%. Both models successfully detected oil spills, but detection performance of the U-net was higher than Simple CNN. Additionally, in order to compare the accuracy of models according to various oil spill cases, the cases were classified into four different categories according to the spatial distribution characteristics of the oil spill (presence of land near the oil spill area) and the clarity of border between oil and seawater. The Simple CNN had F1 score values of 85.71%, 87.43%, 86.50%, and 85.86% for each category, showing the maximum difference of 1.71%. In the case of U-net, the values for each category were 89.77%, 92.27%, 92.59%, and 92.66%, with the maximum difference of 2.90%. Such results indicate that neither model showed significant differences in detection performance by the characteristics of oil spill distribution. However, the difference in detection tendency was caused by the difference in the model structure and the oil spill distribution characteristics. In all four oil spill categories, the Simple CNN showed a tendency to overestimate the oil spill area and the U-net showed a tendency to underestimate it. These tendencies were emphasized when the border between oil and seawater was unclear.

Design of Omok AI using Genetic Algorithm and Game Trees and Their Parallel Processing on the GPU (유전 알고리즘과 게임 트리를 병합한 오목 인공지능 설계 및 GPU 기반 병렬 처리 기법)

  • Ahn, Il-Jun;Park, In-Kyu
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.37 no.2
    • /
    • pp.66-75
    • /
    • 2010
  • This paper proposes an efficient method for design and implementation of the artificial intelligence (AI) of 'omok' game on the GPU. The proposed AI is designed on a cooperative structure using min-max game tree and genetic algorithm. Since the evaluation function needs intensive computation but is independently performed on a lot of candidates in the solution space, it is computed on the GPU in a massive parallel way. The implementation on NVIDIA CUDA and the experimental results show that it outperforms significantly over the CPU, in which parallel game tree and genetic algorithm on the GPU runs more than 400 times and 300 times faster than on the CPU. In the proposed cooperative AI, selective search using genetic algorithm is performed subsequently after the full search using game tree to search the solution space more efficiently as well as to avoid the thread overflow. Experimental results show that the proposed algorithm enhances the AI significantly and makes it run within the time limit given by the game's rule.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

A Development of Automated Design and Structural Analysis Aided-Program based on GUI environment for Aluminum Extrusion Carbody Structures of Railway Vehicle for Design Engineers (설계자를 위한 GUI 환경기반 알루미늄 압출재 철도차량 차체구조물의 자동화 설계 및 구조해석 지원 프로그램 개발)

  • Kim, Jun-Hwan;Kang, Seung-Gu;Shin, Kwang-Bok;Lee, Young-Ju
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.323-328
    • /
    • 2012
  • The purpose of this study is to develop automated structural design and analysis aided-program of aluminum extrusion carbody structures for railway vehicle. This developed program is called "AUTO-RAP" and could perform simultaneously structural design and verification for railway carbody structures made of aluminum extrusion independent of expertise and experience of design engineers. Design engineers are able to conduct the knowledge-based design by providing database of existing aluminum extrusion or user-defined function. The design verification is automatically programmed to evaluate its structural integrity according to Korean Railway Safety Law or Urban Transit Safety Law. In addition, this program could automatically generate an executable file of various commercial finite element programs such as ANSYS and ABAQUS and CAD files such as .stp and .iges by GUI environment applications using MFC(Microsoft Foundation Classes). In conclusion, it is expected to contribute to reduce product design cost and time of carbody structures aluminum extrusions in railway industry.

An Examination on the Dispersion Characteristics of Boil-off Gas in Vent Mast Exit of Membrane Type LNG Carriers (멤브레인형 LNG선박 화물탱크 벤트 마스트 출구에서의 BOG 확산 특성에 관한 연구)

  • Kang, Ho-Keun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Liquefied gas carriers generally transport cargoes of flammable or toxic nature. Since these cargoes may cause an explosion, fire or human casualty, the accommodation spaces, service spaces and control stations of liquefied gas carriers should be so located as to avoid ingress of gas. For this reason, the paragraph 8.2.9 of IGC Code in IMO requires that the height of vent exits should be not less than B/3 or 6 m whichever is greater, above the weather deck and 6 m above the working area and the fore and aft gangway to prevent any concentration of cargo vapor or gas at such spaces. Besides as known, the LNG market has been growing continually, which has led to LNG carriers becoming larger in size. Under this trend, the height of a vent will have to be raised considerably since the height of a vent pipe is generally decided by a breadth of a corresponding vessel. Accordingly, we have initiated an examination to find an alternative method which can be used to determine the safe height of vent masts, instead of the current rule requirement. This paper describes the dispersion characteristics of boil-off gas spouted from a vent mast under cargo tank cool-down conditions in the membrane type LNG carriers.