• Title/Summary/Keyword: 편위

Search Result 116, Processing Time 0.025 seconds

Study on Coordinates Analysis of Oblique Photographs by means of Analytical Rectification (해석적(解析的) 편위수정(偏位修正)에 의한 경사사진(傾斜寫眞)의 좌표해석(座標解析)에 관한 연구(研究))

  • Yeu, Bock Mo;Lee, Dong Cheon;Jong, Chang Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.137-144
    • /
    • 1984
  • In comparison to normal photography, oblique photography has large coverage area and is easily applicable to objects which are difficult to approach. But it has its deficiency of having to go through complex procedures of rectification. Oblique photographs are first analytically rectified, in this paper, then the coordinates of facilities are analysed.

  • PDF

Catenary Measurement System for Real-Time Automated Diahnosis (실시간 자동화 진단을 위한 전차선 검측시스템)

  • Kim, Jeong-Yeon;Park, Jong-Gook;Lee, Byeong-Gon;Hong, Hyun-Pyo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1020-1026
    • /
    • 2011
  • In this paper, we propose a method that measures the height and stagger of an catenary using the laser profile images. One line laser and area scanner CCD cameras are used. To quickly and accurately extract, from a photographed image, the area of the overhead line on which the line laser is shone, we consider the established fact that the catenary is the lowest among the electric wires. Here we are solving the the distance to the catenary if we know the distance the camera is from the ground and the angle of the catenary in the field of view. The angle will be related to the number of pixels in the image. This pixels per degree is a constant for the camera. Also, because of the different pixel resolution of the camera according to the overhead line position, we compensate the measurement result through camera calibration.

  • PDF

Injury of the Medial Rectus Muscle by Using a Microdebrider During Endoscopic Sinus Surgery: A Case Report

  • Choi, Yoon-Seok;Bai, Chang-Hoon;Song, Si-Youn;Kim, Yong-Dae
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.2
    • /
    • pp.240-246
    • /
    • 2006
  • A microdebrider is increasingly used in endoscopic sinus surgery. Although it has many advantages over conventional instruments, it has been associated with severe complications. We treated a case of rupture of the left medial rectus muscle after use of a microdebrider during endoscopic sinus surgery in a 50 year-old female patient who complained of binocular diplopia and exotropia. The patient showed marked limitation on adduction and about 40 prism diopters of left exodeviation. The orbital computed tomography showed a bony defect at the left medial orbital wall, and injury of the medial rectus muscle. The exodeviation was corrected after ophthalmologic surgery. We report a case of the rupture of the medial rectus muscle after use of a microdebrider during endoscopic sinus surgery and review the medical literature.

  • PDF

The relationship between facial asymmetry and maxillary dental arch shape (안면비대칭과 상악치열궁형태의 연관성에 관한 연구)

  • Kim, Dong-U;Son, Won-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.445-456
    • /
    • 1997
  • This study was designed to examine the dental asymmetry in person with facial asymmetry and to examine the relationship between the degree of mandibular deviation and asymmetry of maxillary dental arch. The sample!, were divided to asymmetry group and normal group. The asymmetry group consisted of 21 subjects(6 males and 15 females) and their mean age was 23.5 years. The normal group consisted of 20 subjects(10 males and 10 females) and their mean age was 18.6 years. Anteroposterior, transverse position of all maxillary teeth except 3rd molars, vortical position of maxillary 1st molars, and angulation of central incisors were measured. The anterioposterior and transverse positions of teeth were measured on the maxillary dental casts, the vertical position of maxillary 1st molars and angulation of maxillary incisors were measured on posteroanterior cephalometric radiographs. The data were analyzed to examine whether significant asymmetries existed in each of the asymmetry and normal groups. The results of this study were as follows : 1. In the asymmetry group, the correlation between the degree of mandibular deviation and that of 3-dimensional dental asymmetry was not so high. 2. In the asymmetry group, the teeth in deviated side were more laterally positioned than that of undeviated side. There were differences in the anteroposterior position of maxillary 1st and 2nd molars and the angulation of maxillary central incisors. 3. In the asymmetry group, the transverse asymmetry was larger in the posterior teeth rather than in the anterior teeth and larger than the anteroposterior asymmetry.

  • PDF

NC 공작기계 컨투어 운동 정도의 해석

  • 박준호
    • Journal of the KSME
    • /
    • v.32 no.5
    • /
    • pp.441-455
    • /
    • 1992
  • NC 공작기계의 운동정밀도는 키네마틱 트랜스듀서 링크 컨투어 측정시스템(Kinematic transducer link contour measuring system), BDD 측정시스템, Circular Test 등에 의해 측정될 수 있으며, 오차 발생원인을 규명할 수 있다. 이 글에서는 NC 공작기계의 오차가 컨투어 시험 결과에 미치는 영향을 평가하기 위하여, 공칭원(nominal circle) 혹은 공칭호(nominal arc)로부 터의 반경방향 편위를 포함하는 컨투어 운동결과를 이론적으로 해석하였다.

  • PDF

The relationship between condyle position, morphology and chin deviation in skeletal Class III patients with facial asymmetry using cone-beam CT (안면비대칭을 동반한 골격성 III급 부정교합자에서 하악 과두의, 위치 형태와 이부 편위의 관계: cone-beam CT를 이용한 연구)

  • Lee, Bo-Ram;Kang, Dae-Keun;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.87-97
    • /
    • 2011
  • Objective: Facial asymmetry is usually evaluated from the difference in length and angulation of the maxilla and mandible. However, asymmetric position or shape of the condyle can also affect the expression of asymmetry. The purpose of this study was to evaluate the correlation between condylar asymmetry and chin point deviation in facial asymmetry. Methods: Cone-beam CT images of fifty adult skeletal Class III patients were studied. Thirty patients who had more than 4 mm menton deviation were categorized in the asymmetric group. Twenty patients with less than 4 mm menton deviation were assigned to the symmetric group. Anteroposterior and transverse condyle positions were evaluated from the cranial base. The greatest mediolateral diameter (GMD) of the condyle in the axial plane and angulation to the coronal plane were measured. The height and volume of the condyles were evaluated. Results: The symmetric group had no statistical difference between both condyles in position, angulation, GMD, height and volume. In the asymmetric group, the non-deviated side condyle was larger in GMD, height and volume than the deviated side. There was no statistical difference in condyle position and angulation. The GMD, height difference and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. From the linear regression analysis, condylar volume ratio was a significant factor affecting chin deviation. Conclusions: These findings suggests that the non-deviated side condyle is larger than the deviated side. In addition, condylar asymmetry can affect the expression of facial asymmetry.

Precise Rectification of Misaligned Stereo Images for 3D Image Generation (입체영상 제작을 위한 비정렬 스테레오 영상의 정밀편위수정)

  • Kim, Jae-In;Kim, Tae-Jung
    • Journal of Broadcast Engineering
    • /
    • v.17 no.2
    • /
    • pp.411-421
    • /
    • 2012
  • The stagnant growth in 3D market due to 3D movie contents shortage is encouraging development of techniques for production cost reduction. Elimination of vertical disparity generated during image acquisition requires heaviest time and effort in the whole stereoscopic film-making process. This matter is directly related to competitiveness in the market and is being dealt with as a very important task. The removal of vertical disparity, i.e. image rectification has been treated for a long time in the photogrammetry field. While computer vision methods are focused on fast processing and automation, photogrammetry methods on accuracy and precision. However, photogrammetric approaches have not been tried for the 3D film-making. In this paper, proposed is a photogrammetry-based rectification algorithm that enable to eliminate the vertical disparity precisely by reconstruction of geometric relationship at the time of shooting. Evaluation of proposed algorithm was carried out by comparing the performance with two existing computer vision algorithms. The epipolar constraint satisfaction, epipolar line accuracy and vertical disparity of result images were tested. As a result, the proposed algorithm showed excellent performance than the other algorithms in term of accuracy and precision, and also revealed robustness about position error of tie-points.

Clinical Features of Retinal Correspondence according to Refractive Errors and Deviation Angles (굴절이상과 편위각에 따른 망막대응의 임상적 고찰)

  • Wi, Dae-Gwang;Joo, Seok-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.367-372
    • /
    • 2010
  • Purpose: The purpose of this study was to provide useful information for evaluating the sensory function of patients with strabismus by identifying the distribution of anomalous retinal correspondence (ARC) and normal retinal correspondence (NRC) by the degree of refractive errors and deviation angles. Methods: Objective refraction (AR/K, Cannon RK-F1, Japan) and subjective refraction tests were performed on 56 subjects (male: 26, female: 30) by an examiner; objective deviation angle was measured using synoptophore (OCULUS Synoptophore, Germany) with subject' eyes fully corrected for distance, and then subjective deviation angle was measured. Results: In all groups with refractive errors, the number of ARC was larger than that of NRC(67%). Particularly, it was largest in groups with myopia (71%), and in all groups, the number of UARC was larger than that of HARC. In groups with anisometropia, although the numbers of NRC and ARC were same, the number of UARC was larger than that of HARC as in other groups. In the distribution of NRC and ARC by deviation angle, the number of NRC was larger than that of ARC (46%) only at microstrabismus (0 ~ ${\pm}10{\triangle}$). Conclusions: Normal retinal correspondence were the most emmetropia in the retinal response were much higher than in the more hyperopia than the retinal correspondence were more myopia. In addition, the smaller the angle of retinal correspondence Normal over many, but overall, respectively.

Relative RPCs Bias-compensation for Satellite Stereo Images Processing (고해상도 입체 위성영상 처리를 위한 무기준점 기반 상호표정)

  • Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.4
    • /
    • pp.287-293
    • /
    • 2018
  • It is prerequisite to generate epipolar resampled images by reducing the y-parallax for accurate and efficient processing of satellite stereo images. Minimizing y-parallax requires the accurate sensor modeling that is carried out with ground control points. However, the approach is not feasible over inaccessible areas where control points cannot be easily acquired. For the case, a relative orientation can be utilized only with conjugate points, but its accuracy for satellite sensor should be studied because the sensor has different geometry compared to well-known frame type cameras. Therefore, we carried out the bias-compensation of RPCs (Rational Polynomial Coefficients) without any ground control points to study its precision and effects on the y-parallax in epipolar resampled images. The conjugate points were generated with stereo image matching with outlier removals. RPCs compensation was performed based on the affine and polynomial models. We analyzed the reprojection error of the compensated RPCs and the y-parallax in the resampled images. Experimental result showed one-pixel level of y-parallax for Kompsat-3 stereo data.

Convergent evaluation of Visual function and Stereoacuity function after Surgery for Intermittent exotropia (간헐성 외사시 수술 후 시각 기능과 입체시 기능에 대한 융복합적 평가)

  • Cho, Hyung-Chel;Ro, Hyo-Lyun;Lee, Heejae
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.147-154
    • /
    • 2022
  • This paper evaluated visual function and stereoacuity function after surgery for intermittent exotropia. Subjects of this study were 18 patients (male: n = 10, female: n = 8) mean aged 12.06±5.43 years diagnosed with intermittent exotropia who underwent strabismus surgery. Of these subjects, 72.2% of the subjects underwent strabismus surgery once and 27.8% had it twice. Visual function and stereoacuity function were tested for these subjects. For data analysis, frequency analysis, cross analysis, and correlation analysis were used, and statistical significance was set at p<.05. Regarding the deviation state after strabismus surgery, exodeviation accounted for the most(72.2%), followed by diplopia(50.0%) and suppression(33.3%) for distance sensory fusion. Regarding near sensory fusion, fusion(50.0%) accounted for the most, followed by diplopia(44.4%). After strabismus surgery, subjects with distance stereoacuity blindness were the most at 61.1% and there were no subjects with a normal range of 40-60 arcsec. Near stereoacuity blindness subjects accounted for 33.3% and subjects with 40-60 arcsec accounted for 1.1%. Even after surgery for intermittent exotropia, there were some areas that did not improve in deviation state, stereoacuity, or sensory fusion. Therefore, it is necessary to manage and control strabismus through non-surgical methods before and after surgery for intermittent exotropia.