• Title/Summary/Keyword: 펠티어

Search Result 39, Processing Time 0.026 seconds

A method for Thermal Control of Nano Injection Molding using the Peltier Devices (펠티어 소자를 이용한 나노 사출 금형의 능동형 온도 제어)

  • Shin, H.;Kwon, J.;Hong, N.;Seo, Y.;Kim, B.
    • Transactions of Materials Processing
    • /
    • v.17 no.5
    • /
    • pp.337-342
    • /
    • 2008
  • The injection molding process has high accuracy and good reproducibility that are essential for mass production at low cost. Conventional molding processes typically use the water-based mold heating and air cooling methods. However, in the nano injection molding processes, this semi-active mold temperature control results in the several defects such as air-flow mark, non-fill, sticking and tearing, etc. In order to actively control temperature of the molds and effectively improve the quality of the molded products, the novel nano injection molding system, which uses active heating and cooling method, has been introduced. By using the Peltier devices, the temperature of locally adiabatic molds can be controlled dramatically and the quality of the molded patterns can be improved.

A Study on the Thermal Pump of the Hot Water Boiler (온수 보일러용 열구동 펌프에 관한 연구)

  • Yeom, Han-Gil;Kim, Uk-Joong;Kim, Chang-Ju
    • 연구논문집
    • /
    • s.30
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

A study on Dynamic Characteristics of the Robot Hand Using the Segmented Binary Control (구간분할 바이너리 제어를 이용한 로봇핸드의 동특성에 관한 연구)

  • Jeong Sanghwa;Cha Kyoungrae;Kim Hyunuk;Choi Sukbong;Kim Gwangho;Park Juneho
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.144-149
    • /
    • 2005
  • In recent years, as the robot technology is developed the researches on the artificial muscle actuator that enable robot to move dextrously like biological organ become active. The widely used materials for artificial muscle are the shape memory alloy and the electroactive polymer. These actuators have the higher energy density than the electromechanical actuator such as motor. However, there are some drawbacks for actuator. SMA has the hysterical dynamic characteristics. In this paper the segmented binary control for reducing the hysteresis of SMA is proposed and the simulation of anthropomorphic robotic hand is performed using ADAMS.

  • PDF

Container Design and Development for Smart Marine Logistics System (스마트 해상물류 시스템을 위한 컨테이너 설계 및 개발)

  • Kang, Jisu;Kim, Hyunjin;Park, Dawon;Bae, Soyoung;Lee, Sihyeon
    • Annual Conference of KIPS
    • /
    • 2019.10a
    • /
    • pp.280-283
    • /
    • 2019
  • 통신기술이 1 세에서 5 세대로 발전하는 동안 해상물류의 핵심인 컨테이너는 기능상의 큰 발전없이 과거에 머물러 있다. 이에 본 논문에서는 컨테이너의 위치 및 상태 정보를 수기로 관리하던 기존의 방식에서 벗어나 IoT 장비를 활용해 실시간 위치 파악, 상태 모니터링 및 자동화 등을 통해 물류의 가시성을 확보하고 컨테이너를 효율적으로 재배치함으로써 비용 절감 및 새로운 서비스 창출하기 위한 스마트 컨테이너를 제안한다. 부가적으로, 태양열판을 이용한 전원공급, 펠티어 소자를 이용한 냉방기능을 제공함으로써 신선 식품 배송의 핵심인 풀 코드 체인(Full Cold Chain) 플랫폼으로 활용범위를 넓히고자 한다.

Evaluation of Thermoelectric Characteristics of Peltier Thermoelectric Module for Increasing Response Velocity in Shape Memory Alloy (SMA) Steering Catheter (형상기억합금(SMA) 스티어링 카테터의 반응속도 향상을 위한 펠티어 열전소자의 열전기적 특성 평가)

  • Oh, Dong-Joon;Kim, Cheol-Woong;Kim, Tae-Young;Lee, Ho-Sang;Kim, Jay-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.301-307
    • /
    • 2010
  • Actuation using a shape memory alloy (SMA) is considered to be an important technology that will play a leading role in market for next-generation medical devices because an SMA actuator can accurately imitate skillful and delicate hand movements. However, SMA actuators have not been successfully used because of problems in control design caused by the nonlinear hysteresis effect of SMA, which leads to inaccuracies in control systems. In order to overcome the effect, the authors invented a SMA actuator, which could actively and rapidly cool down and heat up, by combining a SMA catheter and a TE module using the Peltier effect. In order to evaluate the TE characteristics of our TE module system, the changes in the temperature with 1) incremental increases in a continuous electric current and 2) the appearance of a discontinuous constant or reverse current are discussed in this paper.

An Experimental Study on the Optimal Operation Condition of an Air-Cooler using Thermoelectric Modules (열전모듈을 이용한 냉방기의 최적 운전조건에 관한 실험적 연구)

  • Hwang, Jun;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2006
  • This article presents the optimal operation of an air conditioner using thermoelectric modules. A prototype of air conditioner using four thermoelectric modules has been designed and built. The system performance with evaporative cooling for hot side of the module are studied in detail for several operating parameters, such as input power to the thermoelectric module, fans and pump. It is found that the optimal input voltage to the thermoelectric module and pump is selected for the best system performance based on the cooling capacity and the COP at a given operating condition. It is also found that both the cooling capacity and COP of a system is increased with an increase in the input power to fans. The cooling performance could be improved when the ambient temperature is increased and the relative humidity is decreased since the evaporative cooling at the hot side has been increased.

A Haptic Mouse for an Immersive Interface (몰입형 인터페이스를 위한 햅틱 마우스)

  • Kim, Da-Hye;Cho, Seong-Man;Kim, Sang-Youn
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.9
    • /
    • pp.1210-1220
    • /
    • 2011
  • In this paper, we suggest a haptic mouse system as an immersive interface between virtual environment and a human operator. The proposed haptic mouse creates vibrotacitle and thermal sensation to increase the immersion. The vibrotactile module is composed of eccentric motors and a solenoid actuator, and the thermal module consists of a thin-film resistance temperature detector and a Peltier thermoelectric heat pump. In order to evaluate the proposed haptic mouse system, we develop a simple racing game and conduct an experiment. The result of the experiment shows that the proposed haptic mouse system can improve the sense of reality in virtual environment and can be used as an effective interface between virtual environment and a human operator.

Heat Flow and Cooling Performance of an Electronic Refrigerating Kimchi Jar (전자냉동 김치독의 열유동 및 성능 특성)

  • Song, Kyu-Soek;Kim, Kyung-Hwan;Lee, Seung-Chul;Ko, Chul-Kyun;Lee, Jae-Heon;Oh, Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.928-936
    • /
    • 1999
  • The electronic refrigerating kimchi jar operates with a low noise because it contains no compressor but it consumes more energy than that of an refrigerator with compressor. In this paper, the heat flow characteristics and cooling performance of an electronic refrigerating kimchi jar are studied by means of experiments. When the storage temperature is kept in a range of $-5.7^{\circ}C$ to $4.1^{\circ}C$. in the case of three ambient temperatures; $12.7^{\circ}C$, $22.3^{\circ}C$ and $32.2^{\circ}C$, the cooling performance of $20{\ell}$ kimchi jar is investigated. The experiments show that the temperature difference that exists between kimchi jar and its ambient provides a measure of the coefficient of performance of kimchi jar. It is also found that ratio of net pumping heat to the heat pumping rate of thermoelectric module is independent of the temperature difference.

Effect of the Thermoelectric Element Thickness on the Thermal Performance of the Thermoelectric Micro-Cooler (마이크로 열전냉각기의 열성능에 대한 열전소자 두께의 영향)

  • Lee Kong-Hoon;Kim Ook-Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.211-217
    • /
    • 2006
  • The three-dimensional numerical analysis has been carried out to figure out the effect of the thermoelectric element thickness on the thermal performance of the thermo-electric micro-cooler. The small-size and column-type thermoelectric cooler is considered. It is known that tellurium compounds currently have the highest cooling performance around the room temperature. Thus, in the present study, $Bi_{2}Te_{3}$ and $Sb_{2}Te_{3}$ are selected as the n- and p-type thermoelectric materials, respectively. The thermoelectric leg considered is less than $20{\mu}m$ thick. The thickness of the leg may affect the thermal and electrical transport through the interfaces between the leg and metal conductors. The effect of the thermoelectric element thickness on the thermal performance of the cooler has been investigated with parameters such as the temperature difference, the current, and the cooling power.

Effects of Thermoelectric Module Arrangement on the Performance of a Thermoelectric Air-Cooling System (열전모듈 냉방기에서 열전모듈의 개수 및 전원배열이 시스템의 성능에 미치는 영향)

  • Hwang, Jun;Kang, Byung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2007
  • This paper presents the effects of thermoelectric module arrangement on the cooling performance of an air conditioner using thermoelectric module. A prototype of air cooling system, employing several thermoelectric modules, has been designed and built. The evaporative cooling technique is adopted for hot side of the module. The number of thermoelectric module in the system has been varied in the range of $2{\sim}8$. The optimal operation conditions, such as input power to the thermoelectric module, fans and pump, have been determined for each arrangement of the system and the cooling performance has been compared under the optimal operation. It is found that both cooling capacity and COP are increased as the number of thermoelectric module increased. It is also found that cooling capacity can be improved by connecting the thermoelectric modules in series than in parallel, while the COP is little affected.