• Title/Summary/Keyword: 펌프 특성

Search Result 1,224, Processing Time 0.03 seconds

Characteristics of Turbopump and Hydraulic lines of Staged Combustion Cycle Engine (다단연소사이클 엔진의 터보펌프 및 유공압 라인 특성)

  • Lee, Jungho;Jeon, Junsu;Hwang, Chang-Hwan;Woo, Seongphil;Lee, Kwangjin;Yoo, Byungil;Han, Yeoungmin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.94-98
    • /
    • 2017
  • Research for developing 9 tonf-class staged combustion cycle engine which is high performance upper stage engine has been conducted. Technical demonstration model of the staged combustion cycle engine was installed in combustion test facility of Naro space center. Combustion tests of Power-pack which consists of pre-burner and turbopump without main combustion chamber and combustion tests of engine have been conducted. The vacuuming process of hydraulic lines is introduced and the characteristics of turbopump and hydraulic lines of engine combustion test are described in this paper.

  • PDF

Economical Analysis of a Small Capacity Heat Pump utilizing Heat Sources of Air, Geothermal and Underground Water Tank using Dynamic Simulation (동특성 시뮬레이션을 이용한 공기, 지열 및 지하 저수조 열원 소형 열펌프의 경제성 분석)

  • Yang, Chul-Ho;Kim, Youngil;Chung, Kwang-Seop
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.17-23
    • /
    • 2012
  • Due to reinforcement of international environment regulation and high oil prices, interest in renewable energy is growing. Countries participating in UNFCCC are continuously putting efforts in reducing greenhouse gas after enforcing Kyoto Protocol into effect on Feb, 2005. Energy used in buildings, which relies heavily on fossil fuel accounts for about 24% of total energy consumption. In this study, air, geothermal and water source heat pump systems for an 322 $m^2$ auditorium in an office building is simulated using TRNSYS version 17 for comparing energy consumptions. The results show that energy consumptions of air, geothermal and water source heat pumps are 14,485, 10,249, and 10,405 kWh, respectively. Annual equal payments which consider both initial and running costs become 5,734,521, 6,403,257 and 5,596,058 Won. Thus, water source heat pump is the best economical choice.

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

Combustion Characteristics of a Gas Generator Associated with a Turbopump (터보펌프 연계상태의 가스발생기 연소 특성)

  • Seo, Seong-Hyeon;Ahn, Kyu-Bok;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.133-136
    • /
    • 2008
  • The present study presents experimental results of combustion tests of a fuel-rich gas generator associated with a turbopump. Five combustion tests had been successfully executed. Static pressures of the gas generator promptly reacted to propellant supply variations from the turbopump. A closed-loop test for driving the turbopump revealed no flaw. Exit gas temperature results are very similar to previous ones. An orifice was effective on the suppression of pressure fluctuations although tests conducted below 45 bar showed the same dynamic behaviour as that of component-only tests.

  • PDF

On the Performance Test of the Piezoelectric-Hydraulic Pump (압전유압펌프 성능실험에 대한 연구)

  • Joo, Yong-Hwi;Hwang, Jai-Hyuk;Yang, Ji-Youn;Bae, Jae-Sung;Lee, Jong-Hoon;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.822-829
    • /
    • 2015
  • In this paper, the piezoelectric-hydraulic pump with a piezostack actuator as a driving source has been designed, fabricated, and evaluated for its application to UAV's brake system. The performance requirements of the piezoelectric-hydraulic pump were decided based on the requirements analysis of the target aircraft brake system. The geometric design of the piezoelectric-hydraulic pump to meet the performance requirements of the pump was conducted, and all components of the pump including the spring sheet type check valves were machined with close tolerance. By constructing a test apparatus for the performance check of the piezoelectric-hydraulic pump, the performance characteristics of the pump, such as the outlet flow rate for load-free condition and the outlet oil pressure for closed loop condition, have been evaluated. It has been found by the performance test result that the developed piezoelectric-hydraulic pump satisfies the design requirements effectively.

Fabrication and Output Characteristics of an (18+1)×1 Polarization-maintaining Pump and Signal Combiner for a High-power Fiber Laser (고출력 광섬유 레이저용 (18+1)×1 편광유지 펌프 및 신호광 결합기 제작 및 출력 특성)

  • Lee, Sung Hun;Kim, Ki Hyuck;Yang, Hwan Seok;Cho, Seung Yong;Kim, Seon Ju;Park, Min Kyu;Lee, Jung Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.187-192
    • /
    • 2019
  • In this paper a pump combiner, a key component of a high-power fiber laser, was fabricated, and its output characteristics measured using a high-power performance measuring instrument. The $(18+1){\times}1$ pump combiner consists of an optical-fiber bundle of one signal fiber and 18 pump fibers, an output optical fiber, and housing. The signal and output fibers were fabricated using polarization-maintaining optical fiber. By measuring the loss of signal light along the tapering length of the optical-fiber bundle, the tapering length was optimized to 18 mm. Signal-light insertion loss, pump-light transmittance, and polarization extinction ratio of the fabricated $(18+1){\times}1$ pump combiner were measured as 6.5%, 98.07%, and 18.0 dB respectively. The temperature distribution of the pump combiner, at a high power of 2 kW using 18 pump laser diodes, was measured and analyzed using a thermal-imaging camera.

Minimization of Pump Running Cost in the Large-scale Water Supply System (광역상수도 계통의 Pump 운전비용 최소화)

  • Lee, Gwang-Man;Kang, Shin-Wook;Kim, Soo-Myung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.276-281
    • /
    • 2009
  • 장거리 용수공급 시스템에서 전력비용은 전체 운영비용의 큰 부분을 차지한다. 본 연구는 시간단위의 펌프와 배수지 시스템의 최적 운영계획을 수립하기 위해 동적계획기법에 기초한 방법론을 제시하고 있다. 해석방법은 가용 가능한 펌프의 효율적 운전과 전력요금체계, 시간대별 용수수요추이 그리고 배수지 특성과 송수관로의 제약조건 등을 고려하였다. 이를 위해 적용 가능한 시스템 운영목적과 제약조건이 제시되었고 개발된 방법은 수도권 광역상수도 양주계통의 2개 가압장과 5개 배수지를 대상으로 적용되었으며, 적용결과는 상당한 수준의 펌프운전비용을 절감할 수 있는 것으로 나타났다. 이와 같은 방법은 생애주기 비용 최소화 측면에서 실제 용수공급 시설 운영과 대규모 용수공급 체계의 설계 등에 적용이 가능하다.

  • PDF

Characteristic Analysis of High Efficiency Smart BLDC Motor of Pump for Information Technology Cooling (IT 냉각을 위한 펌프용 고효율 Smart BLDC Motor 특성해석)

  • Hong, Do-Kwan;Woo, Byung-Chul;Kim, Jong-Moo;Jeong, Yeon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.836_837
    • /
    • 2009
  • PC용 냉각장치의 일환으로 CPU의 외벽에 방열판을 달고 열전냉각모듈을 설치한 후 방열판을 냉각하기 위해서 펌프를 적용한 수냉식 냉각 시스템을 개발하고자 하였다. 먼저, 냉각 시 펌프의 부하를 설계하고 그 용량에 적절한 저소음, 고효율 BLDC 모터를 개발하고자, 상용화된 외국제품인 S사의 저효율 단상 BLDC 모터가 적용된 수냉식 펌프를 기준으로 하였다. S사의 단상 BLDC 모터에 대한 시뮬레이션과 테스트를 통해서 거의 비슷한 결과를 얻었으며, 이를 이용하여 단가가 다소 상승하더라도 효율과 성능을 향상시킬 수 있는 3상 BLDC 모터구조로 설계를 하였으며, 그 결과 효율이 거의 2배 향상되며 출력 또한 향상됨을 시뮬레이션으로 구현하였다.

  • PDF

Prediction and Optimization of Broadband Erbium-Doped Fiber Source Characteristics by Numerical Simulation (수치해석에 의한 광대역폭 Erbium 첨가 광섬유 광원 특성 예측 및 최적화)

  • 박태용;진영준;박희갑
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.94-95
    • /
    • 2000
  • 광대역폭 erbium 첨가 광섬유(erbium-doped fiber : EDF) 광원은 반도체 광원에 비해서 파장안정성이 우수하여 광섬유 자이로스코프(이하 줄여 자이로라 함)의 광원으로 많이 사용되고 있다.$^{[1,2]}$ 특히 항법용 고급 자이로에서는 광원의 중심파장 안정성이 매우 중요하므로 온도와 같은 외부변화에 관계없이 광원의 중심파장이 일정하게 유지되도록 광원의 최적 설계가 필요하다. 또한 광섬유 광원의 중심파장은 온도변화 뿐만이 아니라 펌프 파장과 펌프 power의 변화에 대해 민감하다. 그러므로 위와 같은 변화가 최소화 될 수 있는 동작조건의 선정이 중요하다. 이 논문에서는 수치 해석을 통해서 EDF의 길이와 펌프 power, 그리고 펌프 파장을 변화에 대해 중심파장의 변화가 최소가 되는 최적동작조건을 도출하였다. (중략)

  • PDF

Waterhammering on Pump Pipeline Systems (펌프 관로계의 수격현상)

  • 김경엽;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.331-355
    • /
    • 1997
  • 본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.

  • PDF