On the Performance Test of the Piezoelectric-Hydraulic Pump (압전유압펌프 성능실험에 대한 연구)

  • Joo, Yong-Hwi;Hwang, Jai-Hyuk;Yang, Ji-Youn;Bae, Jae-Sung;Lee, Jong-Hoon;Kwon, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.822-829
    • /
    • 2015
  • In this paper, the piezoelectric-hydraulic pump with a piezostack actuator as a driving source has been designed, fabricated, and evaluated for its application to UAV's brake system. The performance requirements of the piezoelectric-hydraulic pump were decided based on the requirements analysis of the target aircraft brake system. The geometric design of the piezoelectric-hydraulic pump to meet the performance requirements of the pump was conducted, and all components of the pump including the spring sheet type check valves were machined with close tolerance. By constructing a test apparatus for the performance check of the piezoelectric-hydraulic pump, the performance characteristics of the pump, such as the outlet flow rate for load-free condition and the outlet oil pressure for closed loop condition, have been evaluated. It has been found by the performance test result that the developed piezoelectric-hydraulic pump satisfies the design requirements effectively.

Design Optimization of Two-Way Pump Casing through Flow Analysis (양방향 펌프의 유동 해석을 통한 펌프 케이싱의 최적설계)

  • Kim, Dong-Hwi;Noh, Yoojeong;Lim, O-Kaung;Choi, Eun-Ho;Choi, Ju Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • A two-way pump can reduce costs by draining and circulating water out and into the drum of the washing machine using a single motor whereas a conventional one-way pump uses two motors for doing the same function. However, when the water is drained through the drainage outlet in the two-way pump casing, a backward or inhalation flow occurs and the water flows to the circulation outlet. Likewise, when the water is circulated, the backward flow or inhalation makes the water flow to the drainage outlet. In this study, design optimization of the two-way pump casing is performed to maximize its performance while improving backward flow and inhalation occurring inside of the pump casing. For this, design variables of the pump casing that mainly affect the performance of the pump such as flow rate and torque of the motor were selected through the analysis of mean. Using response surface models for the performances, the ratio of the flow rate to the torque was maximized with satisfying the constraints for the back flow and inhalation through design optimization.

냉각재상실사고시 질량 및 에너지 방출량 감소를 위한 고찰

  • 허재영;이남호;정재훈;권영민;이상종
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.399-404
    • /
    • 1996
  • 1000MWt 급 가압경수로의 질량 및 에너지 방출량을 감소시키기 위한 방안으로 울진 3,4호기를 기준으로 안전주입계통의 형태 및 용량을 변화시키면서 원자로냉각재펌프 토출관 및 고온관 파단에 대한 질량 및 에너지 방출량 계산과 격납건물 첨두압력 및 온도의 민감도를 분석하여, 후속호기 설계에 활용하고자 한다. 분석한 여러 경우 중에서, 토출관 파단사고시 안전주입탱크 용량은 변화시키지 않고 고압안전주입펌프 용량을 l75%로 증가시키면서 저압안전주입펌프를 제거하였을 경우가 격납건물 첨두압력 및 온도가 61.98 psia (3.32 kg/$\textrm{cm}^2$A), 288.03 ℉ (142.24$^{\circ}C$)로써 가장 낮게 나타났다. 이러한 결과는 격납건물의 설계여유도를 기존보다 더 확보하므로 안전성이 향상 될 뿐만 아니라. 저압안전주입펌프를 안전주입계통에서 제외함으로써 발전소 운전에도 큰 도움이 될 것이다.

  • PDF

Characteristic Analysis of High Efficiency Smart BLDC Motor of Pump for Information Technology Cooling (IT 냉각을 위한 펌프용 고효율 Smart BLDC Motor 특성해석)

  • Hong, Do-Kwan;Woo, Byung-Chul;Kim, Jong-Moo;Jeong, Yeon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.836_837
    • /
    • 2009
  • PC용 냉각장치의 일환으로 CPU의 외벽에 방열판을 달고 열전냉각모듈을 설치한 후 방열판을 냉각하기 위해서 펌프를 적용한 수냉식 냉각 시스템을 개발하고자 하였다. 먼저, 냉각 시 펌프의 부하를 설계하고 그 용량에 적절한 저소음, 고효율 BLDC 모터를 개발하고자, 상용화된 외국제품인 S사의 저효율 단상 BLDC 모터가 적용된 수냉식 펌프를 기준으로 하였다. S사의 단상 BLDC 모터에 대한 시뮬레이션과 테스트를 통해서 거의 비슷한 결과를 얻었으며, 이를 이용하여 단가가 다소 상승하더라도 효율과 성능을 향상시킬 수 있는 3상 BLDC 모터구조로 설계를 하였으며, 그 결과 효율이 거의 2배 향상되며 출력 또한 향상됨을 시뮬레이션으로 구현하였다.

  • PDF

Effects of Seal Wear on the Rotordynamics of Multistage Turbine Pump (씨일마모가 다단터빈펌프 동적거동에 미치는 영향)

  • 김영철;이동환;이봉주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.253-259
    • /
    • 1997
  • 씨일의 마모에 따른 터빈펌프의 동적거동을 고찰하기 위해서 10단 터빈펌프를 대상으로 유한요소법에 의한 동특성 해석을 수행하였다. 베어링과 씨일의 동적계수를 회전속도의 하수로 계산하였으며, 이를 동적거동해석에 적용하였다. 해석결과 씨일들은 그 간극이 커질수록 강성 및 감쇠계수가 크게 떨어지고 누설량이 급격히 늘어남을 확인하였다. 따라서 1차 위험속도(1st Critical Speed) 이하에서 충분한 분리여유(Seperation Margine)를 가지고 정상운전되도록 설계된 터빈펌프라 할지라도 장기적 사용시 마모가 진전됨에 따라 계의 1차 위험속도가 변하여 운전속도에 접근할 수 있으며, 아울러 이 때 씨일의 감쇠가 크게 줄어들어 급격한 진동의 증가를 가져올 수 있음을 보였다.

  • PDF

저진공 펌프(rotary, dry)의 배기속도 측정 및 성능평가

  • 서인용;정광화;홍승수;최상철;임인태;임종연
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.52-52
    • /
    • 2000
  • 저진공 펌프 제작시 ISO, AVS 등의 국제규격에 ?춤은 필수이고, 도달진공도, 압력구간별·가스별 배기속도, 소음, 기름증기 역류, 압축비 등이 이에 해당된다. 큰 체적의 시험용기가 구비되어 있지 않은 경우에는 배기감압법 대신 일정유량 Q를 흘려 시험용기내에 일정압력 P를 유지시키면서 배기속도를 S=Q/P식으로 구하는 일정압력법을 사용한다. 이 실험은 800~2000 l/min급 유회전 펌프와 드라이 펌프로 압력별 배기속도를 측정, 분석하여 평가방법을 수립하였다. 또 국가 유량 표준기인 sonic nozzle을 reference로 하여, 기존의 유량측정 장비와의 오차를 비교하였다. 온도 상승도를 측정, 압력과의 상관관계를 비교하였고, 오차가 적은 CDG(1, 10, 100torr)를 사용하여, 압력측정의 정확도를 높였다. 비교적 outgassing이 적은 SUS 재질의 chamber를 썼고, 유량조절 장치로 미세누출밸브를 사용하였다.

  • PDF

Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.

20인치 크라이오 워터펌프 (CWP) 배기성능 종합평가

  • In, Sang-Ryeol;Lee, Dong-Ju;Han, Myeong-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.119.1-119.1
    • /
    • 2016
  • 크라이오 워터펌프(CWP)는 크라이오 펌프(CP)와 달리 10 K 활성탄 어레이는 장착하지 않고 100 K 정도로 냉각시킨 배플만을 사용하여 물의 배기속도를 최적화 하는 데 초점을 맞춘 진공펌프다. 용기 압력이 10-9 mbar 대가 될 때까지는 잔류기체의 90% 이상이 수분이므로 다른 기체들의 배기 보다는 물을 잘 배기하는 것이 배기시간을 단축하고 도달 진공도를 낮추는 첩경이라는 아이디어에 근거를 두고 있다. CWP는 물 흡착확률을 거의 1에 가깝게 만들어서 오리피스 컨덕턴스에 육박하는 이상적인 펌프를 제작할 수 있지만 용도상 직부형(close type), 통과형(in-line type) 및 내장형(in-vessel type) 등 세 가지 다른 형태에 따라 성능도 약간씩 다르다. CWP는 모든 기체에 반응하는 정통적인 CP에 비해 훨씬 간단하고 저렴하게 만들 수 있으면서도 진공 시스템에 큰 영향을 미칠 수 있지만 물 이외의 기체들을 배기할 펌프가 필요하다는 측면에서 활용에 제약이 있다. 만일 TMP를 이미 사용하고 있거나 작은 TMP를 추가로 달아서 충분히 작동이 가능한 시스템이면서 수분 발생이 많은 곳이나, 또 활성탄의 오염이나 산소 분위기 등 CP 투입이 꺼려지는 환경이라면 CWP 사용이 좋은 선택이 될 수 있다. CWP의 물 배기용량은 CP의 알곤이나 질소 배기용량에 준하는 크기로 0.5g/cm2 이상임이 실험적으로 입증되었다. 따라서 일반적인 상황에서 정상 작동시 대부분의 기체는 TMP로 배출하고 잔류 수분만 포집하므로 CP처럼 주기적인 재생이 필요 없다. 필요하다면 CWP는 금속 표면에 응축된 물을 드라이펌프 작동만으로 쉽게 제거할 수 있고 혹시 오염 물질이 붙어도 세척이 용이하다. 이런 사용상 융통성과 여러 가지 장점에도 불구하고 그동안 물배기에 대한 인식이 미흡하고, 또 부수적이고 추가적인 비용이 드는 것으로 생각되어 주목을 받지 못했지만 디스플레이와 반도체 산업을 필두로 물 분압을 낮추고 생산수율을 높이는 것에 점점 더 관심이 높아지면서 CWP에 대한 수요도 높아지고 있다. 본 보고에서는 20인치 통과형 CWP를 만들고 14인치 TMP에 얹어 복합 진공배기시스템을 구성한 후 물 배기속도와 알곤, 질소 및 수소 배기속도를 측정하고 예측치와 비교했다. 아울러 물 배기용량 측정 및 CWP의 온도제어와 펌프재생 특성 평가 결과도 정리했다.

  • PDF

Tubing Wear and Spallation Induced by Roller pumps in Cardiopulmonary Bypass (심폐바이패스 롤러펌프에 의한 튜브 마모 및 폐쇄)

  • 김원곤;성기익;윤철용;신윤철
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.609-616
    • /
    • 1999
  • 심폐바이패스시 발생할 수 있는 튜브 마모 및 파쇄는 롤러펌프의 반복되는 압박에 의해 롤러펌프에 장착된 튜브 내벽에 균열이 생기고 이로 인해 미세한 비생물적 조각들이 혈액중으로 떨어져 나가는 현상을 말하는데, 임상적으로 치명적인 색전증을 초래할 수 있다. 그러나 아직 롤러펌프 튜브로 사용되는 PVC 및 실리콘 튜브 중 어느 쪽이 마모 및 파쇄 관점에서 더 우수한지는 체계적으로 밝혀지지 않고 있다. 이에 본 연구는 두 종류의 튜브를각각 일정 기간 롤러펌프에 장착하여 작동시킨 뒤 튜브내외면을 육안 및 주사형 전자현미경으로 관찰하였다. 즉 PVC 및 실리콘 튜브 (내경 1/2 인치의)들을 미리 정해진 폐쇄도 조절에 의해 폐쇄 회로 심폐비이패스 롤러펌프 헤드에 장착시키고 4.500ml/min에서 각각 4차례씩 1,2,4,6 시간 작동시켰다. 파쇄에 의한 색전 관찰 실험에서는 회로 중간에 동맥여과기를 설치하고 각각 6,9시간 씩 롤러펌프를 작동시켰다. 실험 후 튜브 및 여과기들을 수거한 후 육안 및 주사형 전자현미경 분석을 시행하였다. 실험후 튜브 및 여과기들을 수거한 후 육안 및 주사형 전자현미경을 분석을 시행하였다. 튜브 외부의 육안 관찰 결과 일반적으로 실라스틱 튜브에서의 외부 마모가 PVC 튜브에 비해 현저하였다. 주사형 전자현미경 관찰에서 PVC 튜브에서의 홈은 좁으면서 경계선이 뚜렷한 특징을 보였고 3시간 이상 롤러와 접촉한 튜브들에게서는 깊은 균열이 간헐적으로 관찰되었다. 반면, 실라스틱에서의 홈은 좁으면서도 경계선이 뚜렷한 특징을 보였고 3시간 이상 롤러와 접촉한 튜브들에게서는 깊은 균열이 간헐적으로 관찰되었다.반면 실라스틱에서의 튜브들에서는 홈이 상대적으로 넓고 경계가 덜 명확했으며, 특징적으로 V 자 모양의 융기부들이 간헐적으로 관찰되었다. 실라스틱 및 PVC 튜브 모두에서 50u 전후의 Craters 가 간헐적으로 관찰되었다. 여과기의 여과망에 대한 주사형 전자현미경 분석 결과 실라스틱과 PVC 튜브 실험군 모두에서 색전입자로 의심되는조각들이 발견되었으나 두군간 정량적 비교는 어려웠다. 결론적으로 롤러펌프에 의한 튜브 마모 및 파쇄현상은 실리콘 및 PVC 튜브의 재질에 따라 그 양상에는 차이가 있으나 임상적인 측면에서는 어느 쪽도 상대적인 우수성이 입증되지 못하였다.

  • PDF

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.