• Title/Summary/Keyword: 펌프 시일

Search Result 545, Processing Time 0.034 seconds

Clinical Results of 100 Cases of Coronary Artery Bypass Grafting without Cardiopulmonary Bypass (심폐바이패스 없이 시행한 관상동맥 우회술 100예의 임상적 고찰)

  • 방정희;우종수
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.322-327
    • /
    • 2004
  • Coronary artery bypass grafting on the beating heart is no longer a new methods for any cardiac surgeon. We evaluated the application of the off-pump coronary artery bypass procedure relative to safety and efficiency as measured by postoperative complication and operative mortality. Material and Method: We used our retrospective database to compare the patients having off-pump coronary surgery (n=100) with those having on-pump coronary surgery (n=100) between June, 1999 and August, 2002. Patients whom underwent associated valvular or aortic aneurysmal operation were excluded. Result: Neither groups showed any differences in the patient's risk factors and extent of coronary disease. Off-pump CABG group did not have significantly less mean operation time (295$\pm$73 min vs 323$\pm$83 min, p=ns) and mean hospital day (15.34$\pm$6.02 day vs 13.80$\pm$4.95 day, p=ns). However, off-pump CABG group had significantly shorter mean ventilation time (17.3$\pm$11.27 hour vs 24.98$\pm$16.1 hour, p<0.05). No patients were converted to on-pump CABG in off-pump CABG. Intraoperative hemodynamic instability in off-pump CABG were 6 cases, of whom 2 cases were in lateral wall approach and 4 cases in right coronary anastomosis. Postoperative mortality was 1 case in off-pump CABG and 2 cases in on-pump CABG. Intra-aortic ballon pump (IABP) was applied in 1 case with off-pump CABG and in 2 cases with on-pump CABG. No patients presented postoperative cerebral infarction & stroke in off-pump CABG but 2 patients in on-pump CABG. Postoperative arrhythmia presented in 4 cases with off-pump CABG and in 6 cases with on-pump CABG. Acute renal failure (ARF) was complicated in 3 cases with off-pump CABG and in 2 cases with on-pump CABG. Conclusion: This study documented the immediate safety and efficiency of the off-pump CABG procedure.

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.63-70
    • /
    • 1992
  • The aim of this research is to obtain a basic quantitative understanding of the effect of a noncondensable gas on the absorption of water vapor by a $H_2O$ / LiBr combination with n-octanol as the surfactant. Nonflowing aqueous solutions of LiBr (40,45,50 mass%) were exposed to saturated water vapor following the addition of an n-octanol sufactant (0.01 and 0.6 mass%). A small amount of a noncondensable gas (air) was allowed into the absorber (0.03 volume%) and its effect was analyzed by measuring the amount of water vapor absorbed. This study will aid to predict the performance of heat pump and safety operating condition when the noncondensable gas is not allowed in the absorber The results indicate that, in the presence of small amounts of a noncondensable gas, vapor absorption enhancement ratios are less than half o( those obtained under the same experimental conditions when a noncondensable gas is not present (1). The presence of a noncondensable gas causes the partial vapor pressure of air to increase at the vapor / liquid interface, which results in an instability of vapor absorption rate nd. hence, in an inhibition of interfacial disturbance.

  • PDF

Efficiency of concentrating marine microplanktonic organisms using net sampler to verify the efficacy of a ship's ballast water treatment system (USCG phase-II 선박평형수 처리장치 성능 평가에 대비한 해양식물플랑크톤 네트 농축효율 비교)

  • Baek, Seung Ho;Lee, Min Ji;Shin, kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.136-143
    • /
    • 2016
  • To provide a type approval test for Ballast Water Treatment System (BWTS) of United States Coast Guard (USCG) Phase-II, this study examined the concentrating efficiency of nets for ${\geq}10{\mu}m$ and ${\leq}50{\mu}m$ sized phytoplanktonic organisms using different mesh sized nets ($5{\mu}m$ or $7{\mu}m$), different injection methods (hand breaker as semi-continuous assessment or pump as continuous assessment), and different filterability for the water volume. As a result of the t-test, the net concentrated efficiency between $5{\mu}m$ and $7{\mu}m$ mesh size was not significant (p > 0.05). The difference in the net concentrated efficiency for filtered natural water volume was not significant (p > 0.05). On the other hand, the Chl.a concentration in the continuous water injection method was significantly (p < 0.05) higher than that of semi-continuous water injection (t-test: t: -4.058). In the natural phytoplankton community, a total of 36 species were identified, including Bacillariophyta (17 species), Dinophyta (15 species), Euglenophyta (1 species), Dictyochophyta (2 species), and unidentified taxa (1 species). Among them, diatom Pseudo-nitzchia spp. was remarkably dominant. In particular, the net concentrated efficiency in all assessments was underestimated to be approximately 20-25%, which was caused by the small size Pseudo-nitzchia spp.. A width size of these genus might have passed through the $5{\mu}m$ or $7{\mu}m$ mesh size of the net. Therefore, net concentrated efficiency is dependent on the size of the observed species in natural water. This issue should be considered when determining the net volume for the type approval test of BWTS.

Determination of Flood Reduction Alternatives for responding to climate change in Gyeongan Watershed (기후변화 대응을 위한 경안천 유역의 홍수저감 대안 선정)

  • Han, Daegun;Choi, Changhyun;Kim, Duckhwan;Jung, Jaewon;Kim, Jungwook;Kim, Soo Jun
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.154-165
    • /
    • 2016
  • Recently, the frequency of extreme rainfall event has increased due to climate change and impermeable area also has increased due to rapid urbanization. Therefore, we ought to prepare countermeasures for flood reduction to reduce the damage. To consider climate change, the frequency based rainfall was calculated according to the aimed period(reference : 1971~2010, Target period I : 2011~2040, Target period II : 2041~2070, Target period III : 2071~2100) and the flood discharge was also calculated by climate change using HEC-HMS model. Also, the flood elevation was calculated by each alternative through HEC-RAS model, setting 5 sizes of drainage pumps and reservoirs respectively. The flood map was constructed using topographical data and flood elevation, and the economic analysis was conducted for reduction of flood damage using Multi dimension - Flood Damage Analysis, MD-FDA. As a result of the analysis on the flood control effect, a head of drainage pump was reduced by 0.06m up to 0.44m while it was reduced by 0.01m up to 1.86m in the case of a detention pond. The flooded area shrunk by up to 32.64% from 0.3% and inundation depth also dropped. As a result of a comparison of the Benefit/Cost index estimated by the economic analysis, detention pond E in period I and pump D in period II and III were deemed appropriate as an alternative for climate change. The results are expected to be used as good practices when implementing the flood control works considering climate change.

Establishment of Featal Heart Surgery with an Improvement of the Placental Blood Flow in Cardiopulmonary Bypass Using Fetal Lamb Model (양태아를 이용한 심폐우회술에서의 태반혈류개선을 통한 태아심장수술의 기반기술 확립)

  • 이정렬;박천수;임홍국;배은정;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • Background: We tested the effect of indomethacine and total spinal anesthesia on the improvement of placental flow during cardiopulmonary bypass on fetal lamb. Material and Method: Twenty fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Ten served as a control group in which placenta was worked as an oxygenator during bypass (Control group). The remainder worked as an experimental group in which pretreatment with indomethacine and total spinal anesthesia was performed before bypass with the same extracorporeal circulation technique as control group (Experimental group). Observations were made every 10 minutes during a 30-minute bypass and 30-minute post bypass period. Result: Weights of the fetuses ranged from 2.2 to 5.2 kg. In Control group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of Pa$CO_2$ increased from 61.9 to 129.6 mmHg at each time points during bypass. Flow rate was suboptimal (74.3 to 97.0 $m\ell$/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. On the contrary, in Experimental group, means of arterial pressure reamined higher (45.8 to 30 mmHg) during bypass (p<0.05). Means of Pa$CO_2$ were less ranging from 59.8 to 79.4 mmHg during bypass (P<0.05). Flow rates were higher (78.8 to 120.2 $m\ell$/kg/min) during bypass (p<0.05). There were slower deterioration of cardiac function after cessation of bypass. Conclusion: In this study, we demonstrated that the placental flow was increased during fetal cardiopulmonary bypass in the group pretreated with indomethacine and total spinal anesthesia. However, further studies with modifications of the bypass including a creation of more concise bypass circuit, and a use of axial pump are mandatory for the clinical application.

Study on the Lubricity Characteristics of Bio-heavy Oil for Power Generation by Various feedstocks (다양한 원료에 따른 발전용 바이오중유의 윤활 특성 연구)

  • Kim, Jae-Kon;Jang, Eun-Jung;Jeon, Cheol-Hwan;Hwang, In-Ha;Na, Byung-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.985-994
    • /
    • 2018
  • Bio-heavy oil for power generation is a product made by mixing animal fat, vegetable oil and fatty acid methyl ester or its residues and is being used as steam heavy fuel(B-C) for power generation in Korea. However, if the fuel supply system of the fuel pump, the flow pump, the injector, etc., which is transferred to the boiler of the generator due to the composition of the raw material of the bio-heavy oi, causes abrasive wear, it can cause serious damage. Therefore, this study evaluates the fuel characteristics and lubricity properties of various raw materials of bio-heavy oil for power generation, and suggests fuel composition of biofuel for power generation to reduce frictional wear of generator. The average value of lubricity (HFRR abrasion) for bio-heavy oil feedstocks for power generation is $137{\mu}m$, and it varies from $60{\mu}m$ to $214{\mu}m$ depending on the raw materials. The order of lubricity is Oleo pitch> BD pitch> CNSL> Animal fat> RBDPO> PAO> Dark oil> Food waste oil. The average lubricity for the five bio-heavy oil samples is $151{\mu}m$ and the distribution is $101{\mu}m$ to $185{\mu}m$. The order of lubricity is Fuel 1> Fuel 3> Fuel 4> Fuel 2> Fuel 5. Bio-heavy oil samples (average $151{\mu}m$) show lower lubricity than heavy oil C ($128{\mu}m$). It is believed that bio-heavy oil for power generation is composed of fatty acid material, which is lower in paraffin and aromatics content than heavy oil(B-C) and has a low viscosity and high acid value, resulting in inhibition of the formation of lubricating film by acidic component. Therefore, in order to reduce friction and abrasion, it is expected to increase the lubrication of fuel when it contains more than 60% Oleo pitch and BD pitch as raw materials of bio-heavy oil for power generation.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Steroid Effect on the Brain Protection During OPen Heart Surgery Using Hypothermic Circulatory Arrest in the Rabbit Cardiopulmonary bypass Model (저체온순환정지법을 이용한 개심술시 스테로이드의 뇌보호 효과 - 토끼를 이용한 심폐바이패스 실험모델에서 -)

  • Kim, Won-Gon;Lim, Cheong;Moon, Hyun-Jong;Chun, Eui-Kyung;Chi, Je-Geun;Won, Tae-Hee;Lee, Young-Tak;Chee, Hyun-Keun;Kim, Jun-Woo
    • Journal of Chest Surgery
    • /
    • v.30 no.5
    • /
    • pp.471-478
    • /
    • 1997
  • Introduction: The use of rabbits as a cardiopulmonary bypass(CPB) animal model is extremely dif%cult mainly due to technical problems. On the other hand, deep hypothermic circulatory arrest(CA) is used to facilitate surgical repair in a variety of cardiac diseases. Although steroids are generally known to be effective in the treatment of cerebral edema, the protective effects of steroids on the brain during CA are not conclusively established. Objectives of this study are twofold: the establishment of CPB technique in rabbits and the evaluation of preventive effect of steroid on the development of brain edema during CA. Material '||'&'||' Methods: Fifteen New Zealan white rabbits(average body weight 3.5kg) were divided into three experimental groups; control CA group(n=5), CA with Trendelenberg position group(n=5), and CA with Trendelenberg position + steroid(methylprednisolone 30 mglkg) administration group(n=5). After anesthetic induction and tracheostomy, a median sternotomy was performed. An aortic cannula(3.3mm) and a venous ncannula(14 Fr) were inserted, respectively in the ascending aorta and the right atrium. The CPB circuit consisted of a roller pump and a bubble oxygenator. Priming volume of the circuit was approximately 450m1 with 120" 150ml of blood. CPB was initiated at a flow rate of 80~85ml/kg/min, Ten min after the start of CPB, CA was established with duration of 40min at $20^{\circ}C$ of rectal temperature. After CA, CPB was restarted with 20min period of rewarming. Ten min after weaning, the animal was sacrif;cod. One-to-2g portions of the following tissues were rapidly d:ssected and water contents were examined and compared among gr ups: brain, cervical spinal cord, kidney, duodenum, lung, heart, liver, spleen, pancreas. stomach. Statistical significances were analyzed by Kruskal-Wallis nonparametric test. Results: CPB with CA was successfully performed in all cases. Flow rate of 60-100 mlfkgfmin was able to be maintained throughout CPB. During CPB, no significant metabolic acidosis was detected and aortic pressure ranged between 35-55 mmHg. After weaning from CPB, all hearts resumed normal beating spontaneously. There were no statistically significant differences in the water contents of tissues including brain among the three experimental groups. Conclusion: These results indicate (1) CPB can be reliably administered in rabbits if proper technique is used, (2) the effect of steroid on the protection of brain edema related to Trendelenburg position during CA is not established within the scope of this experiment.

  • PDF

Analysis of Air Temperature and Humidity Distributions and Energy Consumptions according to Use of Air Circulation Fans in a Single-span Greenhouse (단동온실 내 공기순환팬 사용에 따른 온습도 및 에너지소비량 비교 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Kim, Hyung Kweon;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.276-282
    • /
    • 2017
  • The aim of this study was to compare and analyze air temperature and humidity distribution and energy consumptions according to using air circulation fans in single-span greenhouses. The greenhouses located in Cheongnam-myeon, Cheongyang-gun, Chungcheongnam-do, Korea. There were cherry tomatoes in the greenhouses and the size of greenhouses was as follows;ridge height : 3.2 m, wide : 6 m, length : 95 m. The heating system was composed of a hot-water boiler and 6 FCUs(Fan Coil Unit)-4 FCUs were on bottom with duct and 2 FCUs were installed at 2.0 m. A total of 18 air circulation fans(impeller's diameter : 230 mm) were bilaterally arranged in 2 rows in the experimental greenhouse. The sensors for measuring air temperature and humidity were located at a quarter and three quarters of a length. The height of sensors were 0.8 m, 1.8 m. To calculate energy consumption in greenhouses, water temperature at inlet and outlet in a water pump, volume of water were measured. Form February 3rd to March 23th, temperature, humidity and energy consumptions were measured during heating time(6pm~7am). In a greenhouse without fans, the average differences of temperature and humidity were $0.75^{\circ}C$, 2.31%, respectively. The operation of fans showed their differences to $0.42^{\circ}C$, 1.8%. The standard deviation of temperature and humidity between measuring points in the greenhouse with fans was lower than the greenhouse without fans. Total energy consumptions in a greenhouse without fans were 4,673 kWh. In the greenhouse with fans, the total energy consumptions were 4,009 kWh. The energy consumptions in a greenhouse with fans 14.2% were less than the greenhouse without fans. Therefore, air circulation makes temperature and humidity uniform and saves energy consumptions for heating.

A Study on the Cause Analysis and Countermeasures of the Traditional Market for Fires in the TRIZ Method (TRIZ 기법에 의한 재래시장 화재의 원인분석과 대책에 관한 연구)

  • Seo, Yong-Goo;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.95-102
    • /
    • 2017
  • The fires in the traditional markets often occur recently with the most of them expanded into great fires so that the damage is very serious. The status of traditional markets handling the distribution for ordinary people is greatly shrunk with the aggressive marketing of the local large companies and the foreign large distribution companies after the overall opening of the local distribution market. Most of the traditional markets have the history and tradition from decades to centuries and have grown steadily with the joys and sorrows of ordinary people and the development of the local economy. The fire developing to the large fire has the characteristics of the problem that the fire possibility is high since all products can be flammable due to the deterioration of facilities, the arbitrary modification of equipment, and the crowding of the goods for sale. Furthermore, most of the stores are petty with their small sizes so that the passage is narrow affecting the passage of pedestrians. Accordingly, the traditional markets are vulnerable to fire due to the initial unplanned structural problem so that the large scale fire damage occurs. The study is concerned with systematically classifying and analyzing the result by applying the TRIZ tool to the fire risk factors to extract the fundamental problem with the fire of the traditional market and make the active response. The study was done for preventing the fire on the basis of it and the expansion to the large fire in case of fire to prepare the specific measure to minimize the fire damage. On the basis of the fire expansion risk factor of the derived traditional market, the study presented the passive measures such as the improvement of the fire resisting capacity, the fire safety island, etc. and the active and institutional measures such as the obligation of the fire breaking news facilities, the application of the extra-high pressure pump system, the divided use of the electric line, etc.