• Title/Summary/Keyword: 펌프효율

Search Result 617, Processing Time 0.028 seconds

A Study on the Development of the Operation Models for Storm Water Pumps in Detention Pond (유수지 배수펌프 운영조작 모형의 개발)

  • 윤세의;이종태
    • Water for future
    • /
    • v.28 no.6
    • /
    • pp.203-215
    • /
    • 1995
  • Operation models for storm water pumps in detention pond were developed in order to reduce the damage by inundation in urbanized area. The return periods (10, 20, 30 years) of rainfall were selected to estimate inflow discharge to detention ponds. Inflow hydrographs of detention ponds were derived by using the SWMM, and Petri net diagrams were selected to analyze the pump actions. Safety and efficiency of pumps and detention ponds were estimated by penalty index. In order to verify the models, the models were applied to three selected detention ponds in Seoul area. In numerical experimental results, the developed model 3 is more effective in inland flooding prevention than the existing one, and may be used to design and evaluate detention ponds with real time data of rainfall.

  • PDF

Pulse Tube Cryopump 상용화 공정 기술 개발

  • Gang, Sang-Baek;No, Yeong-Ho;Yu, Jae-Gyeong;Go, Deuk-Yong;Park, Seong-Je;Go, Jun-Seok;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.242-242
    • /
    • 2013
  • 현재 크라이오펌프의 주요 관심기술은 생산성 향상을 위한 급속 재생기술의 확보와 극저온 냉동기의 효율 향상 기술 및 저진동 기술의 확보이다. 크라이오펌프는 크게 냉동기 모듈과 펌프모듈로 구성되고, 냉동기 모듈은 주로 G-M 극저온 냉동기, Stirling 극저온 냉동기 또는 맥동관 극저온 냉동기 등을 사용하는데, 이것은 주로 압축기, 왕복기, 재생기, 구동장치 등으로 펌프모듈은 cryoarray와 펌프 body로 구성된다. 최근에 구조가 간단하고 장수명 및 저진동의 장점을 가진 맥동관 극저온 냉동기의 효율이 급속히 증가함에 따라 초전도, 액화 등의 분야에서 기존의 G-M 극저온 냉동기를 대체하는 추세이다. 본 연구에서는 지식경제부 제조기반산업원 천기술사업 "급속재생형 저진동 크라이오펌프 개발" 사업을 통해 급속 재생, 저진동, 고신뢰성 확보를 위해 기존의 G-M 극저온 냉동기를 맥동관 극저온 냉동기로 대체 적용 개발 및 국산화를 도모하고자 한다. 또한 상용화에 따른 공정 개발을 소개하고자 한다.

  • PDF

Actual operation characteristics to evaluate the performance of heat pump outdoor unit in the constant temperature chamber (항온챔버에서 히트펌프 실외기의 성능을 평가하는 실제 운전)

  • Jong-Ryeol Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.3
    • /
    • pp.123-128
    • /
    • 2022
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. In order to conduct a study that does not cause frost on the outdoor unit of the heat pump regardless of the season, a constant temperature chamber like a general room that can be tested under the same conditions as in the natural state was built. The experiment was conducted by providing an environment similar to the natural state to the outdoor unit of the heat pump installed in the constant temperature chamber. As a result, the lower the outdoor temperature, the lower the efficiency of the heat pump. It wat confirmed that the lower the value, the longer it is.

A Study on the Effects of Rotation Rate and Flow Rate on the Operating Characteristics in Centrifugal Pump (원심펌프에서 회전수 및 유량변화가 운전특성에 미치는 영향)

  • Lim, Kwang-Mook;Lee, Sung-Ill
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.56-62
    • /
    • 2019
  • This study examined effects of the operating characteristics of a pump according to the rotational speed of a pump and the change in flow rate when a centrifugal pump operates under the following conditions: regulated flow rate, head, rotational speed, and specific speed of 0.7 m/min, 8 m, 1750 rpm, an 182 (m, ㎥/min, rpm), respectively. The pump in the experiment did not have a guide vane and was connected directly to the rim, so that the rotational speed of the volute pump in a spiral or volute casing increased by 100 rpm from 1350 to 1750 rpm. The result of the relationship between the H-Q, L-Q, and 𝜂-Q characteristics and the dimensionless performance characteristics, such as the head coefficient, power coefficient and efficiency were studied. The change in pump performance could be estimated depending on the increase in the number of revolutions. The maximum efficiency of the pump was 52% with 1450 rpm, 0.165 ㎥/min flux, and 4.73 m of lift. The efficiency reached 50% with a maximum of 1750 rpm, 0.183 ㎥/min of flux, and 6.72 m of lift. The efficiency curve on the performance characteristics of the lift versus flux curve became oval not a curve from a quadratic equation that passes through the starting point according to the similarity law of the pump. Finally, when the flux coefficient increased, the power coefficient increased and the lift coefficient decreased. When the flux coefficient was 0.08, the maximum efficiency was 52%. Therefore, the change in flux affects the driving characteristics.

해외전력 - 유럽의 히트 펌프 시장의 동향

  • 일본 전기협회보
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.385
    • /
    • pp.60-61
    • /
    • 2009
  • 히트 펌프란, 공기, 지중, 지하수 등에서 얼마 안되는 동력으로 효율 있게 열에너지를 끌어올려 장소나 어떤 대상물을 덥게 하거나 차게 하는 에너지절약 기술이다. 일본 등에서는 최근, 이 에너지절약 기술이 $CO_2$ 배출을 억제하는 지구온난화 대책으로서 주목을 받고 있으며, 유럽에서도 일본에 비해 규모는 크지 않으나 히트 펌프 시장이 급속히 확대되고 있다.

  • PDF

고효율 멀티히트펌프를 위한 평가기술

  • Choe, Jun-Yeong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.39 no.11
    • /
    • pp.27-32
    • /
    • 2010
  • 멀티히트펌프 시스템의 시장동향 및 기술동향을 분석하고 향후 경제적, 기술적 파급효과 등을 예측하여 멀티히트펌프 시스템의 산업발전기여 효과를 소개하고자 한다.

  • PDF

Performance Characteristics with Various Fuel Composition and Temperature for an External Type Fuel Pump in LPLi System (LPLi 시스템에서 외장형 펌프의 연료조성 및 온도에 따른 성능특성 연구)

  • Nam, Deok-Woo;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.566-575
    • /
    • 2011
  • Since LPG (Liquefied petroleum gas) fuel supply system has an advantage of low emission characteristics, many studies have been conducted. In spite of the advantage of LPG supply system, a higher vapor pressure and lower viscosity than diesel or gasoline fuel may cause unstable running of fuel pump by the deterioration in lubrication performance and chemical reaction with rubber parts than that of diesel and gasoline fuel. Therefore its physical properties can cause the deterioration of durability. In this research, we developed an external type LPG pump which has the advantage of the price competitiveness and the convenient maintenance for LPLi system. The experiments were carried out in order to assess characteristics of the external type fuel pump at different fuel composition and temperature. As a result, there aren't any differences between internal and external type pump performance. It is observed that the same level of efficiency was maintained for both pumps as flow rate was increased with higher fuel temperature and more contents of propane in the fuel. And the pressure difference in LPLi system is maintained at constant with the various fuel compositions and temperatures due to their own characteristics of fuel supply system.

소형(600l/min 급) 공랭식 건식진공펌프 기술 개발 연구

  • Yu, Jae-Gyeong;Gang, Min-Jeong;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.221-221
    • /
    • 2012
  • 최근 진공 산업은 반도체 산업의 급속한 발전과 더불어 진공 산업이 핵심기술로 부각되고 있으며, 진공 산업의 발전이 고부가가치를 창출하는 산업으로 발전하고 있는 추세이다. 이에 (유)우성진공 기술연구소에서는 국내에서 개발이 전무한 소형급 600l/min. 급의 배기속도를 가지는 공랭식 건식진공펌프 개발과 더불어 중소기업 혁신기술 개발사업의 성공적인 수행으로 인해 상용화 단계에 있다. 본 연구에서는 소형(600l/min. 급) 공랭식 건식진공펌프에 개발 과정 및 성능에 대해 소개하고자 한다. 우선, 여타 건식진공펌프와는 달리 냉각방식이 수냉식이 아니라 공랭식 이라는 점에서 에너지 절감 및 설치 공간 제약이 없으며, 유지 비용을 절감할 수 있는 장점을 가지며, 국내에서는 소형급의 건식진공펌프가 없는 관계로 시장성을 높게 평가하고 있다. 소형급 공랭식 건신진공펌프의 냉각효율을 고려하여 하우징을 알루미늄 합금으로 제작을 하였으며, 냉각핀을 적절하게 배치하여 압축열을 효과적으로 방출하기 위한 구조가 될 수 있도록 설계하였고, 냉각팬에 의한 공랭효과를 극대화하기 위해 펌프 스킨을 사용하여 공기 유로를 형성토록 하였다. 또한, 루츠의 형상 및 각 단의 압축효율을 고려한 최적의 로터를 설계하기 위해 Involute Curve를 이용한 3-Lobe형 로터를 설계하였으며, 로터와 로터간의 Clearance를 유지 할 수 있도록 설계하였다. 향후 최적화된 로터 설계기술과 이형재질(알루미늄과 주철)간 열팽창이 고려된 적절한 clearance 유지기술을 적용하여 안정적인 배기속도 600l/min.와 도달진공도 0.005 torr를 가지는 소형 공랭식 건식드라이펌프를 상용화 하고자 한다. 또한 성공적인 과제 종료 및 기술 개발에 따라 건식진공펌프 시장에 신기술 개발 확산에 따른 기업들 간의 기술 경쟁력 촉진을 통한 국가 기술력 향상을 기대해 볼 수 있다.

  • PDF

Analysis of Flow Characteristics in Pump Sump by Floor Cone Anti-Vortex Device Installation (원뿔 형태의 와류발생저감장치 설치로 인한 펌프 흡수조 내 흐름특성 변화 분석)

  • Byeon, Hyunhyuk;Kim, Heejung;Kim, Seojun;Yoon, Byumgman
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.73-73
    • /
    • 2017
  • 최근 기후변화에 따른 집중호우로 도시홍수의 피해가 급격히 증가하고 있다. 특히 인구가 밀집하고 교통량이 많은 대도시의 경우 동일한 호우에 대하여 녹지나 농경지 등에 비해 그 피해가 더 심각하다. 일반적으로 홍수 피해의 직접원인은 외수로 인한 피해와 내수로 인한 피해로 크게 구분할 수 있다. 외수피해는 주로 소하천 및 지천의 범람, 제방의 붕괴 등으로 발생한 것이며 내수피해는 배수로, 하수도 및 펌프장의 내수배제능력 부족이 주된 원인이다. 따라서 도시홍수를 효과적으로 방어하기 위해서는 우선적으로 내배수시설의 성능개선이 선행되어야 할 필요가 있다. 이러한 내배수 시설 중 빗물펌프장은 흡수조로 우수를 유도한 후 펌프를 이용하여 하천으로 배수하고 있다. 우수를 원활히 하천으로 배수하기 위해서는 흡수조 내 흐름이 안정적으로 형성되어야 한다. 하지만 갑작스런 폭우 등으로 인하여 우수가 짧은 시간에 집중될 경우 흡수조 내에서 빠른 유속과 불규칙한 흐름이 발생하여 와류가 생성된다. 이러한 와류는 펌프 입구로 공기를 유입시켜 효율 저하의 원인이 되며, 공동현상을 발생시켜 펌프의 손상을 초래하기도 한다. 따라서 와류발생 저감장치(Anti-Vortex Device)를 설치하여 와류의 생성을 억제하고자 하는 연구들이 수행되었으며, 그 결과 다양한 형태의 와류발생 저감장치가 소개되었다. 하지만 와류발생 저감장치의 명확한 설계기준이 제시되어 있지 않으며, 와류발생 저감장치를 설치하였을 때 효율이 얼마만큼 증가하는가에 대한 실험적인 자료가 제시되어 있지 않다. 따라서 본 연구에서는 원뿔 형태의 와류발생 저감장치 설치 전 후의 흐름특성을 분석하여 원뿔형태의 와류발생 저감장치가 흐름안정에 얼마나 효과가 있는지를 확인하기 위하여 PIV(Particle Image Velocimetry) 기법을 이용한 유속분포와 와도를 분석하여 흐름 안정 효과를 정량적으로 검토하였다. 그 결과 와류 발생을 저감할 수 있었으며, 정량적으로 와도가 감소하여 펌프 흡입량이 증가됨을 확인하였다. 향후 추가적으로 다양한 형태의 와류발생 저감장치에 대한 효과를 검토한다면 최적의 펌프 흡수조 설계에 도움이 될 것으로 기대한다.

  • PDF

Pump operation based on pressure sensors for the damage reduction of water distribution system (상수도관망의 피해저감을 위한 센서기반 펌프운영)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.200-200
    • /
    • 2019
  • 본 연구에서는 실제 가압장 및 가압장후단부의 상수도관망에 발생가능한 수충격해석을 수행하고 신뢰성해석을 수행하여 파괴확률을 정량적으로 산정하였다. 이를 위해 가압장의 펌프운영조건을 다르게 적용하였고 관말단부의 압력센서를 이용하여 토출압을 선택적으로 운영하면 수충격의 규모도 작아지고 파괴확률도 대폭 줄어드는 것을 확인할 수 있었다. 가압장의 토출압을 선택적으로 운영하기 위해서는 관말단부에 필수적으로 충분한 수압이 존재해야하며 이를 위해서 실시간 모니터링이 가능한 압력계를 설치하게 된다. 이 압력계로부터 수신되는 데이터를 통하여 펌프의 운영이 이루어지고 최소한의 에너지 사용을 통해 효율을 증대하고 피해율도 저감하게 된다. 본 연구에서 개발된 센서기반 펌프운영시스템이 적용된 실제 상수도관망은 현재 가압장의 운영조건으로 24시간 75m의 펌프 토출압을 유지하고 있으며 관말단부의 수용가에 충분한 수압이 전달되고 있다. 가압장의 고압유지는 관말단부에 충분한 수압을 전달하기 위한 것이지만 상수도관망에서 누수와 시설물에 대한 많은 피해를 유발할 수 있다. 따라서 본 연구에서는 가압장의 펌프토출압을 75m와 60m로 선택적 운영을 할 수 있도록 프로그램을 개발하였다. 기존 가압장의 운영조건과 선택적 운영조건을 사용하여 수충격해석을 수행하였고 신뢰성해석모형을 사용하여 파괴확률을 정량적으로 산정할 수 있었다. 가압장의 운영조건을 최적화하여 효율은 증대하고 피해율을 저감할 수 있는 방법을 찾을 수 있었다. 이를 위해서 가압장의 인버터 설치는 물론이고 펌프의 최적운영을 위해 개발된 펌프운영 프로그램을 가압장 배전반에 장착하여 경제적인 운영이 될 수 있을 뿐만 아니라 실제 상수관망에서 과도한 수압으로 인해 발생할 수 있는 여러 가지 피해를 최소화할 수 있을 것으로 판단된다. 또한, 본 연구에서는 기존의 펌프장 토출압으로 운영되었을 때와 비교하여 에너지 절감율을 정량적으로 산정하여 비교분석하였다. 가압장 후단의 작은 마을을 대상으로 하여 절감된 전기요금은 적은 양이라 할 수 있겠으나 개발된 시스템을 전국에 적용한다면 에너지 절감으로 인한 경제적 파급효과는 크다고 할 수 있다.

  • PDF