• Title/Summary/Keyword: 팽창효율

Search Result 294, Processing Time 0.034 seconds

Experimental Study on the Performance Characteristics of a Scroll Expander for 1kW-class Organic Rankine Cycle (1kW급 유기랭킨사이클용 스크롤 팽창기의 성능 특성에 관한 실험적 연구)

  • Kim, Dokyun;Yun, Eunkoo;Yoon, Sang Youl;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2015
  • The performance characteristics of a scroll expander is the most important variable for the performance of organic Rankine cycle system. In this paper, the performance characteristics of a scroll expander was identified using 1kW class organic Rankine cycle system with various operating conditions. The ORC system is composed of an evaporator, a scroll expander, a condenser and a working fluid feed pump that uses R245fa as working fluid. The hot water temperature was controlled from $80^{\circ}C$ to $115^{\circ}C$ by the 50kW-class electric water-heater. The maximum isentropic efficiency of the scroll expander was measured about 77%, and the shaft power was measured from 0.5 kW to 1.8 kW according to heat source temperatures.

Characteristic Study of Micro-Nozzle according to the Ratio of Nozzle Expansion and Specific heats (노즐 팽창비와 비열비에 따른 마이크로 노즐의 특성연구)

  • Oh Hwayoung;Huh Hwanil;Moon Seonghwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.381-385
    • /
    • 2005
  • Recently, spacecraft technology trends can be expressed three words, i.e. 'faster, cheaper and smaller'. Among these systems, micro propulsion device is an essential component. Also micro nozzle is the most important part in the micro propulsion device. In case of cold-gas thruster, micro nozzle converts the stored energy in a pressurized gas into kinetic energy through expansion ratio. In this paper we report characteristics of micro nozzle with throat expansion ratio and ratio of specific heats. We measure thrusts using strain gauge based thrust measurement system. We can estimate the micro nozzle performance through experiments.

  • PDF

A Chancteristic of Thermal Efficiency in Order to High Expansion Realization with a Retard of Intake Valve Closing Time in the Low Speed Diesel Engine (저속 디젤기관에서 흡기밸브 닫힘시기 지연시 고팽창 실현을 위한 열효율 특성)

  • Jang Tae-Ik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.42-49
    • /
    • 2006
  • In this research. the diesel cycle was thermodynamically interpreted to evaluate the possibility of high efficiency by converting diesel engines to the high expansion diesel cycle, and general cycle features were analyzed after comparing these two cycles. Based on these analyses. an experimental single cylinder a long stroke with high expansion-diesel engine. of which S/B ratio was more than 3, was manufactured. After evaluating the base engine through basic experiments, a diesel engine was converted into the high expansion diesel engine by establish VCR device and VVT system Accordingly, the high expansion diesel cycle can be implemented when the quantity of intake air is compensated by supercharge and the effective compression ratio is maintained at its initial level through the reduction of the clearance volume. In this case, heat efficiency increased by $5.0\%$ at the same expansion-compression ratio when the apparent compression ratio was 20 and the fuel cut off ratio was 2. As explained above, when the atkinson cycle was used for diesel cycle, heat efficiency was improved. In order to realize high expansion through retarding the intake value closing time, the engine needs to be equipped with variable valve timing equipment, variable compression ratio equipment and supercharged pressure equipment. Then a high expansion diesel cycle engine is realized.

Study on the prediction about thermal deformation of thin film solar cell according to metal substrates (금속기판재에 따른 박막형 태양전지의 열변형량 예측에 관한 연구)

  • Koo, Seung-Hyun;Lee, Heun-Yeol;Yim, Tai-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.285-288
    • /
    • 2007
  • 박막형 태양전지 및 플렉서블 태양전지 기판으로 사용되는 금속기판의 우수성은 잘 알려져 있다. 그러나 상용 금속기판이 직면하고 있는 문제점을 보완하기 위해서 전주법으로 제조된 2원합금 금속포일을 개발하였으며, 박막형 및 플렉서블 태양전지의 기판재로 적용가능성을 확인하였다. 일반적으로 태양전지를 제조할 때 열 공정이 수행되며, 이때 기판재와 cell을 구성하는 반도체의 열팽창 계수 차이에 의한 열변형으로 결함이 발생될 수 있고, 태양전지 효율 및 수명을 저하시키는 원인이 될 수 있다. 이러한 원인이 될 수 있는 구성 재료간의 열팽창계수 차이에 의한 cell 의 변형량을 추정하기 위해 유한요소해석 방법을 사용하였다. 유한요소해석을 수행하기 위해 ALGOR 라는 해석 tool 을 사용하였다. 유한요소해석 수행에 사용된 상용 금속인 Mo, Ti, Al, SUS 포일과 전주법으로 제조된 2원합금 금속포일의 열팽창 계수는 실험을 통한 측정치이며, cell을 구성하는 반도체의 열팽창 계수와 열특성은 참고 문헌에 있는 자료들이다. 이 값들을 기반으로 cell 의 구성을 단순화시킨 가상의 태양전지가 제조 공정 온도에서 상온으로 냉각될 때의 열변형량을 계산하였다.

  • PDF

Effect of Nitrogen Injection Pressure on Lqiufied Engine Performance (질소 분사 압력이 액화질소 엔진의 성능 특성에 미치는 영향)

  • Shin, Donggil
    • Journal of Energy Engineering
    • /
    • v.26 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • A liquid nitrogen engine is a highly clean power engine, which does not emit any hazardous substances in its fumes. Additionally, it has an advantage over electric vehicles, as its energy density is larger than that of a battery. The use of an existing liquid nitrogen engine is typically limited to the reciprocation type. In this study, the concept of a nitrogen engine equipped with a scroll expander is introduced. The engine's efficiency was shown to increase when the scroll expander was utilized in the engine, while also adding to the simplification of the structure. Therefore, compared to the existing reciprocation-type engine, the engine with the scroll expander has the potential to be both technically and economically more competitive. In this study, the performance of a liquid nitrogen engine equipped with a scroll expander was analyzed while altering the injection pressure profile of liquid nitrogen.

Performance comparison of cascade refrigerator and two-stage compression refrigerator (캐스케이드 냉동시스템과 2단 압축 1단 팽창식 냉동 시스템의 성능 비교)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.625-631
    • /
    • 2014
  • In order to obtain a low evaporation temperature ranging from $-30^{\circ}C{\sim}-50^{\circ}C$, a cascade refrigeration system and two-stage compression one-stage expansion refrigeration system is required. However, the research results of performance comparison of these refrigeration system are very scarce. This paper were compared the performance characteristics of R744-R404A cascade refrigeration system and R404A two-stage compression refrigeration system. The COP of R404A two-stage compression refrigeration system is about 36~57% greater than that of R744-R404A cascade refrigeration system in the range of evaporation temperature of $-30^{\circ}C{\sim}-50^{\circ}C$. But R404A two-stage compression refrigeration system is unstable because COP is significantly changed when evaporating temperature and compressor efficiency decreased. In particular, when compressor efficiency decreased, COP is significantly decreased. In this case, not efficient for long-term use. Whereas R744-R404A cascade refrigeration system using natural refrigerants. Therefore, it is environmentally friendly. And this system is high-efficiency refrigeration system. The reason it can be configured by selecting the suitable refrigerant at high-temperature side and low-temperature side. From the above results, select the appropriate low temperature refrigeration system by considering the environmental and performance aspects.

A Study on Engine Performance at the Intake Air Compensation by Supercharging in the Low Speed Diesel-Atkinson Cycle (과급에 의한 흡입공기 보상 시 저속 디젤-아트킨슨사이클에서 엔진성능에 대한 연구)

  • Jang, Tae-Ik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1009-1015
    • /
    • 2011
  • In this study, in the high expansion cycle was conduced by variable valve timing system composition to close intake valve late, and in the intake air reduction on the low compression was solved by supercharging pressure. In this wise, by constituting Diesel-Atkinson cycle, this study looked into a possibility of thermal efficiency improvement. As a result, there was improvement in thermal efficiency and output in a whole range of closing timing from ABDC $40^{\circ}$ to ABDC $80^{\circ}$. However, after ABDC $70^{\circ}$ of closing timing, the thermal efficiency increase was getting smaller. As the result of the study, the optimum intake valve closing timing was about ABDC $70^{\circ}$, high loading territory of engine was more effective than low loading territory, and engine operation in middle loading territory was stable. At this time, brake thermal efficiency was 12.5% higher than ordinary engine on average.

Waterproofing performance evaluation according to the number of layer for shield TBM segment hydrophilic rubber waterstop (쉴드 TBM 세그먼트 지수재의 배열수 변화에 따른 방수성능 평가)

  • Ham, Soo-Kwon;Jung, Hoon;Kim, Beom-Ju;Jeong, Kyeong-han;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.47-58
    • /
    • 2020
  • The interest in the use of shield TBM (Tunnel Boring Machine) on the tunnel excavation has been increased rapidly in Korea. The shield TBM tunnel is generally designed as non-drainage tunnel. Consequently, if water leakage through the segment joints happens, big problems on the usage and stability of tunnel can be occurred. In this study, the variation of waterproof capacity of hydrophilic rubber waterstop by the construction error and excessive displacement of segment was studied. In particular, the waterproof capacity of each of single and double layer arrangements of hydrophilic rubber waterstop was examined to verify the efficiency of the double layer arrangement. The test results show that the single layer and double layer hydrophilic rubber waterstop showed the same waterproof performance. hydrophilic rubber waterstop has favorable on the offset, however unfavorable on the gap.

Optimization of Coal Ash Water Treatment Conditions to Suppress Concrete Pop-out Based on Coal Ash Containing Expansion Components (팽창성분이 혼입된 석탄재 기반 콘크리트의 팝아웃 발생 억제를 위한 석탄재 수처리 조건 최적화)

  • Jae-Jin Hong;Joo-Han Kang;Mi-Na Kim;Woo-Seong Choi;Myung-Jun Oh;Seong-Yun Kim
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.226-231
    • /
    • 2024
  • Coal ash has been used as a sand replacement in the construction industry. Due to the use of bituminous coal as a result of anthracite depletion, and quicklime as an air purifier in the desulfurization process, pop-out defects have recently occurred in concrete using coal ash, severely limiting the recycling of coal ash into concrete. In this study, the components that cause the pop-out problem of the coal ash filled concrete were identified and a pretreatment method to fully expand the expansive components in advance was proposed as a solution to this problem. By treating water twice for 10 min, allowing the CaO mixed in the coal ash to fully expand, the problems of pop-out and reduced compressive strength of the concrete were overcome. The cost and time efficient water treatment method proposed in this study is expected to promote the recycling of coal ash into concrete.

Study on the performance characteristics of a new CO2 auto-cascade heat pump system (새로운 CO2 오토 캐스케이드 열펌프 시스템의 성능특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.191-196
    • /
    • 2017
  • Owing to the harmful environmental effects of HCFC and CFC refrigerants discovered in the late 20th century, the need for environmentally friendly refrigerants such as $CO_2$ in cooling systems has increased. Air-source $CO_2$ heat pumps that utilize ambient heat in cold winter are less efficient because of a higher evaporation temperature, and it is difficult to manufacture the components of the heat pump owing to a super critical pressure of over 130 bar. This research aims to overcome these disadvantages and improve energy efficiency by introducing a new lower-pressure $CO_2$ auto-cascade heat pump system. $CO_2$-R32 zeotropic refrigerants were considered for two-stage expansion and effective cooling heat exchanging system configurations of the new auto-cascade heat pump. The results indicated that the efficiency of the two-stage expansion system was higher than that of the original one-stage expansion system. Furthermore, the two-stage expansion system showed significant performance improvements when the two-stage expansion stage from highest pressure of 70bar, intermediate expansion pressure of 25bar, and final low pressure of 10bar is applied. The COP of the new two-stage auto-cascade system (2.332) was 43.15% higher than that of the present simple auto-cascade system (1.629). Refrigerants having an evaporation temperature of $-10^{\circ}C$ or lower can be obtained that can be easily evaporated in an evaporator even at a low temperature.