• 제목/요약/키워드: 판막질환

Search Result 242, Processing Time 0.833 seconds

Measurement of Porcine Aortic and Pulmonary Valve Geometry and Design for Implantable Tissue Valve (돼지 대동맥, 폐동맥의 근위부 기하학적 구조 측정을 통한 판막 구조 수치의 계량화와 판막 도안에 관한 연구)

  • Park, Sung-Joon;Kim, Yong-Jin;Nam, Jin-Hae;Kim, Soo-Hwan;Lee, Chang-Ha;Lim, Hong-Gook
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.602-613
    • /
    • 2010
  • Background: As life expectancy has been increased, the cardiac valve disease has been increased. In past, mechanical valve for valve replacement surgery was used widely, but it has many weaknesses, such as hemorrhage, teratogenic effect caused by warfarin, acute mechanical failure, taking warfarin during life, etc. So, the tissue valve is used widely and researches for durability of tissue valve are in progress. Tissue valves being used are all imported in Korea, and there is a lack of information on its geometry and design. So, we studied the geometry of porcine aortic and pulmonary valve, and tried to suggest theoretical basis for making the aortic and pulmonary valve. Material and Method: We harvested aortic and pulmonary valves of 25 pigs and measured the geometry of valve at fresh and glutaraldehyde (GA) fixed state. In each group, we measured the diameter of the base, diameter of commissure, valve height, commissural height, etc. Also, for making implantable porcine and bovine pericardial valve, we designed the valve stent form, thickness, height, and leaflet size, form, thickness by different size of valve. Result: The aortic and pulmonary valve geometry and ratio were measured in each group. The right coronary cusp of aortic valve and right facing cusp of pulmonary valve was bigger than other cusps and non coronary cusp was smaller than others (RCC: NCC : LCC=1 : 0.88 : 1). Valve height was correlated to the leaflet size. We designed the outer diameter of stented porcine aortic valve from 19 mm to 33 mm and designed stent height and width, using previous measured ratio of each structure, stent thickness, working thickness (for making valve). Also, we designed the size of stent and form for stented bovine pericardial valve, considering diameter of valve, leaflet length, height and leaflet minimum coaptation area. Conclusion: By measuring of 25 pig's aortic and pulmonary valve geometry and ratio, we can make theoretical basis for making implantable stented porcine valve and bovine pericardial valve in various size. After making implantable valve using these data, it is necessary to do in vivo and in vitro researches, furthermore.

Mitral Valve Reconstruction in Mitral Insufficiency : Intermediate-Term Results (승모판 폐쇄부전증에서 승모판 재건술의 중기평가)

  • 김석기;김경화;김공수;조중구;신동근
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.705-711
    • /
    • 2002
  • The advantages of mitral valve reconstruction have been well established and so mitral valve reconstruction is now considered as the procedure of choice to correct mitral valve disease. This is the report of intermediate-term results of 38 cases that performed mitral valve reconstruction for valve insufficiency(the total number of mitral valve reconstruction were 49 cases, but 11 cases that performed mitral valve replacement due to incomplete reconstruction were excluded). Material and Method : From March 1991 to March 2001, 38 patients underwent mitral valve repair due to mitral valve regurgitation with or without stenosis. Mean age was 47.6$\pm$14.7 years(range 15 to 70 years) : 11 were men and 27 were women. The causes of mitral valve regurgitation were degenerative in 14, rheumatic in 21, infective in 2 and the other was congenital. Result : According to the Carpentier's pathologic classification of mitral valve regurgitation, 3 were type 1 , 16 were type II and 19 were type III. Surgical procedures were annuloplasty 15, commissurotomy 19, leaflet resection and annular plication 9, chordae shortening 11, chordae transfer 5, new chordae formation 2, papillary muscle splitting 2 and vegetectomy 2. These procedures were combined in most patients. There were 2 early death and the causes of death were respiratory failure, renal failure and sepsis. There was no late death. Valve replacement was done in 6 patients after repair due to valve insufficiency or stenosis 3 weeks, 1, 3, 51, 69, 84months later respectively. These patients have been followed up from 1 to 116 months(mean 43.0 months). The mean functional class(NYHA) was 2.36 pre-operatively and improved to 1.70. Conclusion : In most cases of mitral valve regurgitation, mitral valve reconstruction when technically feasible is effective operation that can achieve stable functional results and low surgical and late mortality.

Early Results of Maze III Operation Without Cryoablation (냉동절제 없이 시행한 Maze III 술식의 조기 결과)

  • 김형수;이원용;오동진;지현근;홍기우;두영철
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.255-261
    • /
    • 1999
  • Background: Atrial fibrillation is one of the most prevalent of all arrhythmias and in up to 79% of the patients with mitral valve disease. This study examined whether the atrial fibrillation that occur in patients with mitral valve operation could be eliminated by a concommitant maze operation without cryoablation. Material and Method: From May 1997 to April 1998, 14 patients with atrial fibrillation associated with mitral valve disease underwent Maze III operation without cryoablation. Preoperatively there were 6 men and 8 women with an average age of 46.2${\pm}$10.7 years. Eleven patients had mitral stenosis, and three had mitral insufficiency. The associated heart diseases were aortic valve disease in 4, tricuspid valve regurgitation in 1 and ASD in 2. Using transthoracic echocardiography, the mean left atrial diameters was 54.7${\pm}$5.3 mm and thrombi were found in the left atrium of 2 patients. Postoperatively the ratio between the peak speed of the early filling wave and that of the atrial contraction wave (A/E ratio) was determined from transmitral flow measurement. Operations were mitral valve replacement in 13 including 4 aortic valve replacements, 1 DeVega annuloplasty and 2 ASD closures. Maze III operation was performed in 1 patient. Result: Five patients (38%) had recurred atrial fibrillation, which was reversed with flecainide or amiodarone at the average time of postoperative 38.8${\pm}$23.5 days. Postoperative complications were postoperative transient junctional rhythm in 6, transient atrial fibrillation in 5, reoperation for bleeding in 3, postpericardiotomy syndrome(1), unilateral vocal cord palsy(1), postoperative psychosis(1), and myocardial infarction(1). Postoperatively A/E ratio was 0.43${\pm}$0.22 and A wave found in 9(64%) patients. 3 to 14 months postoperatively (average follow- up, 8.1 months), all of patients had normal sinus rhythm and 9(64%) patients had left atrial contraction and 11(79%) patients were not on a regimen of antiarrhythmic medication. Conclusion: We conclude that Maze III operation without cryoablation is an effective surgical treatment in atrial fibrillation associated with the mitral valve disease.

  • PDF

Valve Replacement in Children (소아심장판막치환술)

  • 김재현;이광숙;윤경찬;유영선;박창권;최세영
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • Background: Thirty children ranging from 3 to 15 years of age underwent cardiac valve replacement at Dongsan Medical Center from 1982 to 1997. Material and Method: There were 16 boys and 14 girls. The mean age was 12.1. The underlying pathological cause for valve replacement was congenital heart disease in 17 children and acquired heart disease in 13. The valve replaced was mitral in 15 children, aortic in 11, tricuspid in 3, and combined aortic and mitral in 1. Twenty-one mechanical and 10 tissue valves were placed: primary mechanical valve have been utilized since 1985. Eight of ten patients with tissue valves have had successful second valve replacements 4 to 11 years after the initial operation. Result: The operative mortality was 6.7%, but mortality was higher among patients less than 5 years of age and patients who had previous cardiac operations. Of the 28 operative survivors, 4 patients were lost to follow-up: the remaining patients were observed for a total of 2091 patient/months(mean 74.7 months, maximum 187 months). There was one late death from dilated cardiomyopathy after mitral valve replacement in 7 year-old patient with atrioventricular septal defect. After the operation, all patients with mechanical valves were placed on a strict anticoagulant regimen with Coumadin. The actuarial survival rate was 96% at the end of the follow-up. No instance of thromboembolism or major bleeding were observed in the survivors. Conclusion: These results indicate that valve replacement can be performed with low mortality in children, and with satisfactory long-term survival.

  • PDF

A Case Report of Acute Type II Aortic Dissection in a Patient with Marfan's Syndrome and Who Was 24 Weeks Pregnant - A case report - (임신 24주 Marfan 증후군 환자에서의 급성 제II형 대동맥 박리 - 1예 보고 -)

  • Hwang, Ui-Dong;Ryu, Yang-Gi;Lim, Ju-Yong;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.508-511
    • /
    • 2007
  • The causes of aortic dissection are usually hypertension, connective tissue disease such as Marfan syndrome, congenital valvular abnormality such as bicuspid aortic valve, iatrogenic injury, pregnancy and drugs. Previous studies have shown that 50% of all dissections in women less than 40 years age were associated with pregnancy. Almost all aortic dissections during pregnancy occur during the third trimester or during labor and delivery. Marfan's syndrome is a particularly important predisposing factor for aortic dissection during pregnancy. We report here on a case of surgical treatment for acute type II aortic dissection in a Marfan syndrome patient who was 24 weeks pregnant, and we include a review of literature.

Avulsion of Aortic Commissure: Rare Cause of Aortic Regurgitation - 2 case reports - (교련부 분리에 의해 발생한 대동맥판 역류 - 치험 2예 -)

  • Choi, Jae-Woong;Hwang, Ho-Young;Choi, Eun-Suk;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.777-780
    • /
    • 2009
  • We reported here on 2 cases of aortic regurgitation (AR) that were due to avulsion of the aortic valve commissure. Aortic valvuloplasty was attempted in both cases. In the 1st case, valvuloplasty was performed with reattaching the commissure using the 5-0 polypropylene continuous suture technique. However, aortic regurgitation recurred and this lead to reoperation on the postoperative $14^{th}$ day. The intraoperative finding revealed a completely re-detached commissure that required mechanical valve replacement. In the second case, we attempted to reattach the commissure using pledgetted multiple transverse mattress sutures with 5-0 polypropylene. Because the leaflet coaptation was incomplete, the aortic valve was replaced with a tissue valve.

Clinical Study of Composite Valve Graft Replacement of the Aortic Root (대동맥 근부 복합 인공 판막 도관 치환술에 관한 임상적 고찰)

  • Park, Kwon-Jae;Woo, Jong-Soo;Cho, Gwang-Jo;Bang, Jung-Hee;Jeong, Sang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.260-265
    • /
    • 2010
  • Background: A composite valve graft replacement has been used for a variety of aortic root diseases. The aim of this study was to evaluate the mid-term results of this technique. Material and Method: We conducted a retrospective analysis of aortic root composite valve graft replacements in 39 patients and these procedures were done at our institution between 1992 and 2009. The mean age of the patients was $49.2{\pm}16.4$ years. The mean follow-up was $64.2{\pm}53.4$ months (maximum: 176 months). Result: There were 4 hospital deaths (8.6%) due to emergency aortic dissection and 4 late deaths owing to several causes. The causes of late death were 2 ruptures of a remnant aneurysm, 1 subdural hemorrhage and 1 paravalvular leakage. The calculated survival rate was 93.5%, 85.0% and 85.0% at 1, 5 and 10 years, respectively. There were 3 cerebrovascular accidents during the follow up period. The rate of freedom from cerebrovascular accidents was 97.0%, 92.0% and 80.0% at 1, 5 and 10 years, respectively. All of these brain accidents were hemorrhage-related complications. Conclusion: A composite valve graft replacement of the aortic root was associated with favorable results. So, this technique seems to be a good method to treat various aortic root diseases.