• Title/Summary/Keyword: 판막

Search Result 929, Processing Time 0.023 seconds

Cineradiographic Diagnosis of Mechanical Valve Thrombosis - Two Cases Report - (기계판막혈전의 cineradiographic 진단;2례 보고 `)

  • 나찬영
    • Journal of Chest Surgery
    • /
    • v.25 no.9
    • /
    • pp.921-924
    • /
    • 1992
  • 기계판막의 가장 빈번하고 치명적인 결함이 판막혈전이다. 판막혈정의 적절한 조기 치료를 위해서는 조기진단이 선행되어야만 한다. Cineradiography는 조기에 손쉽고, 빠르게 기계판막의 기능장애를 진단하는 방법으로 사료되며 저자들은 42세된 남자 환자에서 29mm Carbomedics 판막으로 승모판막 치환술을 시행한 1례와 58세된 여자 환자에서 승모판막 및 대동맥판막에 각각 25mm, 19mm Carbomedics 판막으로 치환술 후 각각 18개월, 20개월 후 기계판막 혈전이 발생하여 cineradiography로 손쉽게 진단하여 치료하였으므로 보고하는 바이다.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

Nonstructural Dysfunction of Mechanical Valve (인공판막의 비구조적 기능이상)

  • Shin, Jong-Mok;Jeong, Dong-Seop;Kim, Kyung-Hwan;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.1
    • /
    • pp.91-93
    • /
    • 2001
  • 기계판막의 비구조적 기능이상은 판막 치환 후 생길 수 있는 심각한 합병증 중의 하나이다. 이러한 기계판막의 비구조적 기능이상은 일반적으로 1) pannus나 조직 혹은 봉합물질에 의한 장애 2) 치환 판막 주위의 틈 3) 부적절한 판막의 크기나 위치, 판막 삽입시의 잘못 등에 의해 생긴다. 저자들은 상대적으로 작은 판막륜을 가진 환자에서 치환 판막의 잘못된 위치로 야기된 pannus 형성에 의한 판막의 기능부전을 경험하였으며, 이 환자에 대해 pannus 제거 후 판막륜 확장술(닉스 술식, Nicks procedure)을 포함한 판막 재치환술을 성공적으로 시행하여 이를 보고하는 바이다.

  • PDF

Congenital Quadricuspid Semilunar Valve - A case report - (선천성 사엽성 반월형 판막 - 1예 보고 -)

  • Seo, Min-Bum;Seo, Hong-Joo
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.361-363
    • /
    • 2009
  • A 17-year-old male patient was referred with symptoms of dyspnea. Multi-detector computerized tomography (MDCT) and echocardiography evaluation revealed quadricuspid aortic and pulmonary valves, an atrial septal defect (ASD), and pulmonary stenosis. We closed the ASD using a bovine patch and performed a commissurotomy of the pulmonary valve. Quadricuspid semilunar valves are very rare congenital abnormalities that are reported to occur nine times more frequently in the pulmonic valve than in the aortic valve. According to the Hurwitz Roberts classification, the aortic valve was type A, and the pulmonic valve was type B. The aortic valve normal function, but the pulmonic valve was stenotic and had abnormal function.

Annular Plication Technique to Facilitate Sliding Annuloplasty in a Marfan's Syndrome Patient (말판 증후군 환자에서 승모판막 역류의 교정을 위해 시행된 슬라이드 판막륜 성형술 및 판막륜 주름 성형술)

  • Je, Hyoung-Gon;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.441-444
    • /
    • 2007
  • Sliding annuloplasty has been used for mitral valve repair in conjunction with posterior leaflet quadrangular resection to avoid systolic anterior motion of the anterior leaflet of the mitral valve. Herein, we report on a case of successful mitral valve repair with using the annular plication technique to facilitate sliding annuloplasty and extensive quadrangular resection was also done for treating a Marfan's syndrome patient who had an extremely redundant leaflet and a severely dilated annulus.

Mitral Valve Replacement with a Pulmonic Autograft (자가 폐동맥 판막을 이용한 승모판막 치환술- 1례 보고 -)

  • 이재원;김건일;정성호;최현정;송명근
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.361-364
    • /
    • 2001
  • 자가 폐동맥 판막을 이용한 대동맥 판막 치환술을 항응고제 복용이 필요없고 내구성이 어느정도 입증되어 늘어나고 있으나, 자가 폐동맥 판막을 이용한 승모판막 치환술은 국내에 보고된 예가 없다. 53세 여자 환자로 류마티스성 승모판막 협차가 및 폐쇄부전, 삼첨판막 폐쇄부전, 만성 심방 세동, 그리고 자회전 관상동맥의 폐색등으로 진단받은 환자에서 자가 폐동맥 판막을 이용한 승모판막 치환술 및 maze 술식, 삼천판막 성형술, 관상동맥 우회수술을 시해하였다. 수술후 특별한 문제없이 회복하였으며 술후 시행한 심초음파 검사상 자가 폐동맥 판막의 이상 소견없이 잘 기능하고 있으며 항응고제 복용없이 잘 지내고 있다.

  • PDF

Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage (작은 인공판막주위 누출에 의한 용혈성 빈혈)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.444-448
    • /
    • 1996
  • Hemolytic anemia due to tiny prosthetic paravalvular leakage is one of a complication of prosthetic valve replacement. Mild Hemolysls usually occurs after aortic valve replacement with mechanical valve but rarely occurs in mitral valve position especially in case of tissue valve. Cardiac valves fabricated from biologic material are associated with a reduced incidence of hemolytic anemia. Hemolysis was reported in patients with an lonescu-Shiley bovine pericardial xenograft prosthesis in the aortic position but not in the mitral site. A 41-year-old female patient was admitted due to sudden development dark colored urine. About 10 years ago the patient was underwent MVR (Mitral Valve Re lacement) with fTmm lonescu-Shiley valve due to MR (Mitral regurgitation). Echocardiographic examination showed mild degree of mitral regurgitation with valvular thickening. However, there was no definitive evidence of paravalvular leakage. The peripheral blood smear showed nomochromic normocytic anemia, but the hematologic and urinary examination revealed severe hemolytic evidence. Mitral valve replacement with St. Jude Medical valve (27mm) was done and intraoperatively, a tiny paravalvular leakage was found which was regarded as the point of hemolysis. The hemolytic evidence completely disappeared. We are reporting a case of severe hemolytic anemia due to tiny prosthetic paravalvular leakage with a review of the literature.

  • PDF

Measurement of Porcine Aortic and Pulmonary Valve Geometry and Design for Implantable Tissue Valve (돼지 대동맥, 폐동맥의 근위부 기하학적 구조 측정을 통한 판막 구조 수치의 계량화와 판막 도안에 관한 연구)

  • Park, Sung-Joon;Kim, Yong-Jin;Nam, Jin-Hae;Kim, Soo-Hwan;Lee, Chang-Ha;Lim, Hong-Gook
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.602-613
    • /
    • 2010
  • Background: As life expectancy has been increased, the cardiac valve disease has been increased. In past, mechanical valve for valve replacement surgery was used widely, but it has many weaknesses, such as hemorrhage, teratogenic effect caused by warfarin, acute mechanical failure, taking warfarin during life, etc. So, the tissue valve is used widely and researches for durability of tissue valve are in progress. Tissue valves being used are all imported in Korea, and there is a lack of information on its geometry and design. So, we studied the geometry of porcine aortic and pulmonary valve, and tried to suggest theoretical basis for making the aortic and pulmonary valve. Material and Method: We harvested aortic and pulmonary valves of 25 pigs and measured the geometry of valve at fresh and glutaraldehyde (GA) fixed state. In each group, we measured the diameter of the base, diameter of commissure, valve height, commissural height, etc. Also, for making implantable porcine and bovine pericardial valve, we designed the valve stent form, thickness, height, and leaflet size, form, thickness by different size of valve. Result: The aortic and pulmonary valve geometry and ratio were measured in each group. The right coronary cusp of aortic valve and right facing cusp of pulmonary valve was bigger than other cusps and non coronary cusp was smaller than others (RCC: NCC : LCC=1 : 0.88 : 1). Valve height was correlated to the leaflet size. We designed the outer diameter of stented porcine aortic valve from 19 mm to 33 mm and designed stent height and width, using previous measured ratio of each structure, stent thickness, working thickness (for making valve). Also, we designed the size of stent and form for stented bovine pericardial valve, considering diameter of valve, leaflet length, height and leaflet minimum coaptation area. Conclusion: By measuring of 25 pig's aortic and pulmonary valve geometry and ratio, we can make theoretical basis for making implantable stented porcine valve and bovine pericardial valve in various size. After making implantable valve using these data, it is necessary to do in vivo and in vitro researches, furthermore.

Valve Leaflet Escape of Edwards Duromedics Mechanical Valve - A Case report - (Edwards Duromedics 기계판막엽 탈출 - 1례 보고 -)

  • 윤영남;유경종
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Edwards Duromedics mechanical valve was introduced into clinical use in 1982 and is still being used today after several modifications. Valve-related complications after mechanical valve replacement are thiombo-embolism, endocarditis, valve malfunction, valve leaflet escape and fracture. Incidence of valve leaflet escape is very low. A 40 year-old male patient who had undergone mitral replacement with a 31mm Edwards Duromedics mechanical valve(model

Long Term Results of Carbomedics Mechanical Valve (Carbomedics 기계판막 치환환자의 장기성적)

  • 김병열;임용택;정승혁;강경훈;이정호
    • Journal of Chest Surgery
    • /
    • v.33 no.7
    • /
    • pp.552-559
    • /
    • 2000
  • Background; The aim of this study is to evaluate our clinical experience with the Carbomedics heart valve prosthesis. Material and Method; Between Aug. 1988 and Dec. 1998, 294 Carbomidics valves were implanted in 235 patients(mitral; 143, mitral and aortic; 59, aortic; 33) The mean age at operation is 40.0$\pm$12.3 years(range 7 to 68 years); 63.8% (150patients) were woman. Follow up was 97.4% complete and mean follow up time was 5.7years with a total of 1209.2 patient-years. Result; The hospital mortality was 8.9%(mitral; was 95.2$\pm$1.6%(mitral ; 94.9$\pm$2.1%, mitral and aortic 95.0$\pm$3.7%, aortic 96.2$\pm$3.8%). Actual freedom rates from complications(linearized rates in parentheses) were fllowings; thromboembolism 96.2$\pm$1.5%(0.59%pt-yr), valve thrombosis 96.7$\pm$1.4%(0.5%/pt/yr), anticoagulant related hemorrhage 98.3$\pm$1.0%(0.25%/pt-yr), perivalvular leak 99.0$\pm$1.4%(0.5%/pt-yr), endocarditis 98.7$\pm$1.0%(0.25%/pt-yr), perivalvular leak 99.0$\pm$0.7%(0.17%pt-yr), endocarditis 98.7$\pm$1.0%(0.17%$\pm$pt-yr) and overall valve-related complications 88.9$\pm$2.5%(1.68%/pt-yr). Conclusion; The clinical performance of the Carbomedics valve was quite satisfactory with a low incidence of valve related mortality and morbidity.

  • PDF