• Title/Summary/Keyword: 판독시간

Search Result 230, Processing Time 0.025 seconds

Optical information storage using diffraction properties of volume hologram in Fe-LiNbO$_3$ crystal (Fe-LiNbO$_3$결정에서 부피형 홀로그램의 회절특성을 이용한 광정보 저장)

  • An, Jun-Won;Kim, Nam;Lee, Kwon-Yeon
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.63-71
    • /
    • 1998
  • In this paper, we experiment the characteristics of coupling coefficient, gain, diffraction efficiency and dependence of time determined by TWM(Two-Wave Mixing), using Fe-LiNbO$_3$ crystal(doped with 0.015Wt.%). From these results, we proposed to apply for optical memory application. The highest coupling angle of 14。 and maximum coupling coefficient of 6.9$cm^{-1}$ / are obtained at 514.5nm wavelength. Also, maximum diffraction efficiency is 54.13% when intensity ratio and writing beam incident angle are 0.1 and 14o, respectively. After fixing process, diffraction efficiency is 21.4%. As an example, we demonstrated the writing and reconstruct optical data using spatial light modualtor and angular multiplexing in most optimal condition.

  • PDF

Convenient Methods for the Extraction and Discrimination of Water-Soluble Plant Pigments (수용성 식물 색소 추출 및 판별에 관한 간편한 방법)

  • Chung, Sang-Ho;Byun, Young-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.353-360
    • /
    • 2009
  • The use of colorants as additives for foods and drinks is a significant factor to food consumers in determining the acceptability of processed foods. In recent years, the number of previously used artificial colorants/dyes suitable for food use has been drastically reduced as a result of toxicological studies. Therefore, the use of natural pigments such as anthocyanins and betacyanins that were known to have anticancer and antioxidant activities is increasingly required. In this study, the water-soluble plant pigments, anthocyanins and betacyanins, were easily extracted with a very simple method using a few organic solvents such as ethyl acetate, ethyl ether, and chloroform. After the extraction of them, these two major plant pigments could be also simply and rapidly separated and discriminated by a solely one-stepped agarose gel electrophoresis in a citrate buffer (pH 3.0).

Mobile Mapping System Development Based on MEMS-INS for Measurement of Road Facility (도로시설물 계측을 위한 MEMS-INS 기반 모바일매핑시스템(MMS) 개발)

  • Lee, Kye Dong;Jung, Sung Heuk;Lee, Ki Hyung;Choi, Yun Soo;Kim, Man Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • The purpose of this study is that the low-cost mobile mapping system using INS (Inertial Navigation System) based on MEMS (Micro Electro Mechanical System) could decipher the interpretation of road facility with the accuracy of x, y 0.546m plane error. Even though the MMS (Mobile Mapping System) technology as a new measurement technology has been used vividly to set up geographic information by some world leading surveying equipment manufacturers, the domestic technology is still in its beginning stage. Several domestic institutes and companies tried to catch up the leading technology but they just produced prototypes which needs more stabilization. Through this thesis, we developed low-cost mobile mapping system installed with INS based on MEMS after time synchronizing sensors for MMS such as LiDAR (Light Detection And Ranging), CCD (Charge Coupled Device), GPS/INS (Global Positioning System / Inertial Navigation System) and DMI (Distance Measurement Instrument).

Development of Total Cholesterol Detection System by Fluorescence Chromatography (형광 크로마토그래피에 의한 콜레스테롤 측정법의 개발)

  • Oh, Sang-Wook
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.2
    • /
    • pp.148-153
    • /
    • 2009
  • In this study, we have developed a fluorescence chromatographic assay for the quantification of total cholesterol in serum, which is a well-known risk predictor for cardiovascular diseases. The new assay system consists of a chromatographic strip in a cartridge, enzyme buffer containing cholesterol esterase, cholesterol oxidase, horseradish peroxidase, and color developer AEC, and a laser fluorescence scanner. The correlation coefficient (r) between cholesterol concentration and relative fluorescence units was 0.968 in the new assay, showing a reliable linearity through the tested range of cholesterol. Recovery test and comparability with a Hitachi 747 instrument showed 106.5-94% and r = 0.939 (p<0.001), respectively. The new assay system for cholesterol was developed as a pre-POCT platform conducted in clinics since it is fast (8 min) and uses a small volume of sample ($5\;{\mu}l$), and it may be applied for on-site diagnostics to replace expensive automated biochemical analyzer.

A CASE STUDY ON CLINICAL APPLICATION OF COMPUTED TOMOGRAPHY IN PEDIATRIC DENTISTRY (소아치과 영역에서 전산화 단층촬영술의 임상적 활용에 대한 증례보고)

  • Lee, Yoon-Seok;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.3
    • /
    • pp.493-498
    • /
    • 1998
  • Computed tomography(CT) has become more widely available in recent years and is recognized as an important diagnostic tool for complex disease and condition of the orofacial structure in adults. In pediatric patients, especially in the mixed dentition period, the number of superimposing dental structures in the jaw bone is much greater than in the permanant dentition period. Therefore, in spite of radiation risk, computed tomography should sometimes be used in pediatric patients in order to obtain a precise and valid diagnosis. This case study presents clinical application of computed tomography on patients visiting department of pediatric dentistry in Seoul National University Dental Hospital. The results obtained through these cases were summarized as follow : 1. Localization of impacted teeth using CT allows for efficient treatment planning leading to reduced postoperative complications. 2. In orthodontic traction of impacted permanent teeth, utilization of CT made exact localization of window site and determination of prognosis possible. 3. Use of CT made possible definite diagnosis of lesions in the jaw that were only suspected on plain film radiographs. 4. Careful selection is necessary when applying CT on children due to increased radiation dose and high cost.

  • PDF

An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants (원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.176-183
    • /
    • 2009
  • Maintenance on the water chamber of steam generator during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, characteristic analysis of inhomogeneous radiation fields for contact operations was conducted using thermoluminescent dosimeter (TLD) readouts from the application tests of two-dosimeter algorithm to Korean NPPs in 2004. It is regarded that inhomogeneous radiation fields for contact operations in NPPs are dominated by high energy photons. In addition, field tests for workers who participated in maintenance on the steam generator during outage at Ulchin NPPs in 2009 and pressure tube replacement at Wolsong NPPs in 2009 were conducted to analyze radiation fields and to estimate the extremity dose. As a result, radiation fields were dominated by high energy photons.

Development of a Multi-View Camera System Prototype (다각사진촬영시스템 프로토타입 개발)

  • Park, Seon-Dong;Seo, Sang-Il;Yoon, Dong-Jin;Shin, Jin-Soo;Lee, Chang-No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.261-271
    • /
    • 2009
  • Due to the recent rise of a need for 3 dimensional geospatial information on urban areas, general interest in aerial multi-view cameras has been on an increase. The conventional geospatial information system depends solely upon vertical images, while the multi-view camera is capable of taking both vertical and oblique images taken from multiple directions, thus making it easier for the user to interpret the object. Through our research we developed a prototype of a multi-view camera system that includes a camera system, GPS/INS, a flight management system, and a control system. We also studied and experimented with the camera viewing angles, the synchronization of image capture, the exposure delay, the data storage that must be considered for the development of the multi-view camera system.

WHITENING EFFECT OF BLEACHING AGENTS ON TETRACYCLINE-STAINED RAT TEETH (테트라싸이크린에 의해 변색된 백서 치아에 대한 표백제의 표백 효과)

  • Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.364-371
    • /
    • 1999
  • 본 연구는 테트라싸이클린에 의해 변색된 백서 치아에 대한 3 종 표백제의 표백효과를 비교하고 표백제의 침투 깊이 (법랑질 두께)에 따른 표백효과의 차이를 판별하기 위해 시행되었다. 30 마리의 웅성 백서에 매일 2주 동안 테트라싸이클린 용액을 복강내 주입하였다. 디스크 형태의 32개 백서 치아 표본을 16 시간 동안 자외선으로 조사하여 변색을 야기시켰다. 대조군은 생리 식염수에 보관하였으며 실험군은 3종 표백제(Opalescence, Rembrandt, NiteWhite)에 하루 5회씩 2주간 노출시켰다. 치아 색상을 표백전, 표백 1일, 3일, 5일, 7일, 9일, 11일, 및 14일에 각기 기록하여 치아내 변색부와 정상 색상간의 색상차 (${\Delta}$E)를 판독하였다; 대조군 - 9.78, 9.17, 9.36, 9.65, 9.40, 9.99, 10.57, 11.36; Opalescence - 10.08, 7.63, 6.72, 6.04, 5.10, 4.87, 4.89, 4.27; Rembrandt -9.83, 11.27, 9.55, 8.36, 7.75, 6.94, 7.11, 7.04; NiteWhite - 10.44, 9.92, 7.58, 6.80, 5.45, 5.05, 4.73, 4.01. 표백된 모든 치아들의 색상이 밝아졌다. (p<.01) 테트라싸이클린이 주입된 56개 백서 치아를 3 일간 자외선에 조사한 다음, 3가지 유형의 표백제 침투깊이를 설정하였다. 설측 상아질과 순측 법랑질을 통한 침투 (DN), 순측 법랑질만을 통한 침투 (RE), 1.0 mm 두께의 사람 법랑질로 피개된 순측 법랑질을 통한 침투 (HE). 표본들을 Opalescence로 하루 5회씩 1주일 및 4 주간 표백한 후 횡단하여 치아 색상을 측정하였다. 표백되지 않은 치아들을 대조군으로 이용하였다. 치아내 변색부와 정상 색상간의 색상차 (${\Delta}$E)는 다음과 같았다. 대조군 - 11.67; 1주 DN 군 - 13.55; 1주 RE군 - 12.80; 1 주 HE군 - 12.07; 4주 DN군 - 7.48; 4주 RE군 - 7.50; 4주 HE군 - 11.69. 4주 DN군과 4주 RE군의 색상 변화가 가장 크게 나타났다.(p<.01)

  • PDF

Design and Implementation of a Smart Tag System for Ubiquitous Port Logistics (유비쿼터스 항만 물류 환경을 위한 스마트 태그 시스템의 설계 및 구현)

  • Cho, Hyun-Tae;Baek, Yun-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.8
    • /
    • pp.1500-1510
    • /
    • 2007
  • In recent, rapid and accurate processing for logistics have been required, according as logistics has grown dramatically. Especially, identifying, locating, or tracking objects in ports are important, because ports are gateways to extended markets. In this paper, we describe the design and implementation of a smart tag system for ubiquitous port logistics. Our solution consists of three parts: an active RFID to identify objects, an electronic container seal to charge with security of containers, and a RTLS system to locate objects. Because identification technology for logistics can be read by heterogenous systems, compliance with the international standard is one of the most critical issues. This paper introduces the method to maintain compliance with ISO, and conducts some verifications. In addition, we analyze the system performance such as lifetime, identification rate, and time for multiple tag identification.

Development of High Resolution Iris Camera Module using IoT Device (IoT 디바이스를 활용한 고해상도 홍채 카메라 모듈 개발)

  • Seo, Jin-beom;Cho, Young-bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.3
    • /
    • pp.371-377
    • /
    • 2020
  • Currently used iris cameras are expensive and have many limitations in their use. Existing iris cameras are inconvenient in interworking with newly developed software, and light reflections generated during iris photography are inadequate for medical use. Therefore, it is impossible to utilize the existing camera to take an image by yourself. In this paper, the iris camera is newly constructed so that the iris can be photographed by ourselves and the area of interest can be seen well. Anyone can easily wear glasses-type iris cameras to acquire images using IoT devices, and the acquired images are linked to the iris analysis program and used to read genetic weak parts. The proposed iris camera module automatically provides light reflection, shake, and accurate focus when capturing images, increasing the accuracy of image analysis to 91.49%. In addition, we have proved through experiments that one image processing time is fast as 0.007ms due to accurate image input.