• Title/Summary/Keyword: 판독시간

Search Result 232, Processing Time 0.026 seconds

The Study of Digitalization of Analog Gauge using Image Processing (이미지 처리를 이용한 아날로그 게이지 디지털화에 관한 연구)

  • Seon-Deok Kim;Cherl-O Bae;Kyung-Min Park;Jae-Hoon Jee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.4
    • /
    • pp.389-394
    • /
    • 2023
  • In recent years, use of machine automation is rising in the industry. Ships also obtain machine condition information from sensor as digital information. However, on ships, crew members regularly surveil the engine room to check the condition of equipment and their information through analog gauges. This is a time-consuming and tedious process and poses safety risks to the crew while on surveillance. To address this, engine room surveillance using an autonomous mobile robot is being actively explored as a solution because it can reduce time, costs, and the safety risks for crew. Analog gauge reading using an autonomous mobile robot requires digitization for the robot to recognize the gauge value. In this study, image processing techniques were applied to achieve this. Analog gauge images were subjected to image preprocessing to remove noise and highlight their features. The center point, indicator point, minimum value and maximum value of the analog gauge were detected through image processing. Through the straight line connecting these points, the angle from the minimum value to the maximum value and the angle from the minimum value to indicator point were obtained. The obtained angle is digitized as the value currently indicated by the analog gauge through a formula. It was confirmed from the experiments that the digitization of the analog gauge using image processing was successful, indicating the equivalent current value shown by the gauge. When applied to surveillance robots, this algorithm can minimize safety risks and time and opportunity costs of crew members for engine room surveillance.

Automatic Detection of Stage 1 Sleep Utilizing Simultaneous Analyses of EEG Spectrum and Slow Eye Movement (느린 안구 운동(SEM)과 뇌파의 스펙트럼 동시 분석을 이용한 1단계 수면탐지)

  • Shin, Hong-Beom;Han, Jong-Hee;Jeong, Do-Un;Park, Kwang-Suk
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.1
    • /
    • pp.52-60
    • /
    • 2003
  • Objectives: Stage 1 sleep provides important information regarding interpretation of nocturnal polysomnography, particularly sleep onset. It is a short transition period from wakeful consciousness to sleep. The lack of prominent sleep events characterizing stage 1 sleep is a major obstacle in automatic sleep stage scoring. In this study, utilization of simultaneous EEG and EOG processing and analyses to detect stage 1 sleep automatically were attempted. Methods: Relative powers of the alpha waves and the theta waves were calculated from spectral estimation. A relative power of alpha waves less than 50% or relative power of theta waves more than 23% was regarded as stage 1 sleep. SEM(slow eye movement) was defined as the duration of both-eye movement ranging from 1.5 to 4 seconds, and was also regarded as stage 1 sleep. If one of these three criteria was met, the epoch was regarded as stage 1 sleep. Results were compared to the manual rating results done by two polysomnography experts. Results: A total of 169 epochs were analyzed. The agreement rate for stage 1 sleep between automatic detection and manual scoring was 79.3% and Cohen’s Kappa was 0.586 (p<0.01). A significant portion (32%) of automatically detected stage 1 sleep included SEM. Conclusion: Generally, digitally-scored sleep staging shows accuracy up to 70%. Considering potential difficulty in stage 1 sleep scoring, accuracy of 79.3% in this study seems to be strong enough. Simultaneous analysis of EOG differentiates this study from previous ones which mainly depended on EEG analysis. The issue of close relationship between SEM and stage 1 sleep raised by Kinnari remains a valid one in this study.

  • PDF

Automatic Detection of Stage 1 Sleep (자동 분석을 이용한 1단계 수면탐지)

  • 신홍범;한종희;정도언;박광석
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.11-19
    • /
    • 2004
  • Stage 1 sleep provides important information regarding interpretation of nocturnal polysomnography, particularly sleep onset. It is a short transition period from wakeful consciousness to sleep. Lack of prominent sleep events characterizing stage 1 sleep is a major obstacle in automatic sleep stage scoring. In this study, we attempted to utilize simultaneous EEC and EOG processing and analyses to detect stage 1 sleep automatically. Relative powers of the alpha waves and the theta waves were calculated from spectral estimation. Either the relative power of alpha waves less than 50% or the relative power of theta waves more than 23% was regarded as stage 1 sleep. SEM (slow eye movement) was defined as the duration of both eye movement ranging from 1.5 to 4 seconds and regarded also as stage 1 sleep. If one of these three criteria was met, the epoch was regarded as stage 1 sleep. Results f ere compared to the manual rating results done by two polysomnography experts. Total of 169 epochs was analyzed. Agreement rate for stage 1 sleep between automatic detection and manual scoring was 79.3% and Cohen's Kappa was 0.586 (p<0.01). A significant portion (32%) of automatically detected stage 1 sleep included SEM. Generally, digitally-scored sleep s1aging shows the accuracy up to 70%. Considering potential difficulties in stage 1 sleep scoring, the accuracy of 79.3% in this study seems to be robust enough. Simultaneous analysis of EOG provides differential value to the present study from previous oneswhich mainly depended on EEG analysis. The issue of close relationship between SEM and stage 1 sleep raised by Kinnariet at. remains to be a valid one in this study.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

The Characteristics Analysis of Low Profile Meander 2-Layer Monopole Antenna (소형 미앤더 2-층 모노폴 안테나의 특성분석)

  • Jang, Yong-Woong;Lee, Sang-Woo;Shin, Ho-Sub
    • Journal of Broadcast Engineering
    • /
    • v.19 no.6
    • /
    • pp.934-941
    • /
    • 2014
  • In this paper, we present a low profile 2-layered meander built-in monopole antenna for portable RFID reader using FDTD(Finite Difference Time Domain) method. The input impedance, return loss, and VSWR in the frequency domain are calculated by Fourier transforming the time domain results. The double meander 2-layer structure is used to enhance the impedance matching and increase the antenna gain. The measured bandwidth of the antenna is 0.895 GHz ~ 0.930 GHz for a S11 of less than -10dB. The measured peak gain of proposed low profile RFID built-in antenna is 2.3 dBi. And the proposed built-in antenna for portable RFID reader can offers relatively wide-bandwidth and high-gain characteristics, in respectively. Experimental data for the return loss and the gain of the antenna are also presented, and they are relatively in good agreement with the FDTD results. This antenna can be also applied to mobile communication field, energy fields, RFID, and home-network operations, broadcasting, and other low profile mobile systems.

In vivo and In vitro Chromosome Aberration Test of Gentamicin as a Verterinary Drug (식품에 잔류하는 Gentamicin의 유전독성평가에 관한 연구)

  • Ha, Kwang-Won;Oh, Hye-Young;Kang, Chun;Son, Soo-Jung;Park, Jang-Hwan;Heo, Ok-Soon;Han, Eui-Sik;Kim, So-Hee;Kim, Myung-Hee;Moon, Hwa-Hoi
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.249-249
    • /
    • 1996
  • Gentamicin은 임상에서 많이 사용되는 aminoglycoside계 항생물질로서 세균의 세포막 단백질 합성을 억제하여 살균작용을 나타낸다. 최근 Gentamicin이 동물사료에 포함되거나 동물약품으로 많이 사용되어, 이를 복용한 식용가축에서의 잔류 량에 대한 인체유해성이 WHO/FAO 식품첨가물 전문가 협의회에서 논의되고 있다. Gentamicin의 육가공류의 잔류허용량 기준설정을 위한 독성 재평가의 일환으로 in vivo. in vitro 염색체이상시험을 실시하여 다음과 같은 결론을 얻었다. 1. 체외 염색체이상시험에서는 포유동물 배양세포인 chinese hamster lung cell을 배양하여 gentamicin sulfate 및 gentamicin을 최고 처리농도 5mg/$m\ell$부터 세포독성시험을 실시한 결과, 세포독성을 나타내지 않았다. 본 시험에서는 5mg/$m\ell$를 최고농도로 2.5, 1.25mg/$m\ell$의 3농도를 직접법 및 대사활성화법으로 각 농도당 2매의 플레이트씩 슬라이드를 제작, 결과를 판독한 결과, 직접법 및 대사활성화법 모두에서 전 농도 군에서 음성대조군과 같은 정도의 염색체이상을 유발하여 유전독성이 없음을 나타내었다. 2. 체내 염색체 이상시험에서는 ddY마우스를 이용하여 gentamicin sulfate의 LD$_{50}$의 1/2에 해당하는 200mg/kg을 최고농도로 gentamicin 과 gentamicin sulfate를 암수 각각 3마리씩 공비 2의 3농도로 투여한 후, 24시간째 골수세포의 염색체 표본을 제작하여 관찰한 결과, 세포독성 및 염색체 이상을 유발하지 않았다. 또한 동물약품으로 사용되는 치료용량 및 투약방법에 근거하여 10mg/kg 및 5, 2.5mg/kg을 1일 1회씩 4회 투여한 군에서도 암수에 상관없이 전 농도 군에서 염색체이상을 나타내지 않아 유전독성을 나타내지 않음을 관찰하였다.

  • PDF

Cross Compressed Replication Scheme for Large-Volume Column Storages (대용량 컬럼 저장소를 위한 교차 압축 이중화 기법)

  • Byun, Siwoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2449-2456
    • /
    • 2013
  • The column-oriented database storage is a very advanced model for large-volume data analysis systems because of its superior I/O performance. Traditional data storages exploit row-oriented storage where the attributes of a record are placed contiguously in hard disk for fast write operations. However, for search-mostly datawarehouse systems, column-oriented storage has become a more proper model because of its superior read performance. Recently, solid state drive using MLC flash memory is largely recognized as the preferred storage media for high-speed data analysis systems. In this paper, we introduce fast column-oriented data storage model and then propose a new storage management scheme using a cross compressed replication for the high-speed column-oriented datawarehouse system. Our storage management scheme which is based on two MLC SSD achieves superior performance and reliability by the cross replication of the uncompressed segment and the compressed segment under high workloads of CPU and I/O. Based on the results of the performance evaluation, we conclude that our storage management scheme outperforms the traditional scheme in the respect of update throughput and response time of the column segments.

Application of Wiener filter to Chest CR images (흉부 CR영상에 대한 위너필터의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.519-524
    • /
    • 2018
  • Chest examinations and mass chest examinations using the CR(computed radiography) System are frequently used clinically. a factor that degrades image quality in the acquisition process is the use of unused IPs long times. this paper addresses the estimation of winer filter and improved wiener filter to restoration of Chest CR images Experimental results show that the proposed method can reduce noise. in low noise variation image wiener method was excellent than improved method and the result was the opposite at high noise varience. the application of algorithms to chest CR images effectively eliminates noise. the classic Wiener filter was better than the improved method. Multiple patients examined during the process without any erase IP(image plate) process, The proposed algorithm determines that the images can be restored to a good quality and will help to read the images.

Expert-Novice Differences in Reading and Predicting Visual Information in Air Traffic Control (항공관제 전문성 수준에 따른 시각정보 판독과 미래정보 예측 차이)

  • Kwon, Hyuk-Jin
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.3
    • /
    • pp.18-27
    • /
    • 2015
  • Many studies have shown that having perception of spatial information is important for air traffic control officer (ATCO) since it helps them understand the current situation and predict the situation it leads to. However, little or no research has been done to investigate if there is any difference at the levels of expertise in perceiving spatial information and predicting a prospective situation. This study investigates the difference between expert and novice ATCO groups in how accurately each group of ATCO perceive spatial information such as position, altitude, speed, and flying direction, and predicting such information they will encounter shortly. In completing a task to watch the movement of airplanes displayed on the computer monitor as a blip, the participants were asked to predict the position, speed, and the altitude of the aircraft in a minute by marking on the sector map. The results show that the expert group performed better in accuracy and had tendency to overestimate on position and altitude; however, no significant difference was found between the two groups in terms of reading a flying direction. Therefore reading a flying direction may not be a reliable indicator to judge expertise of ATCO. But the expert group shows better predicting performance by perceiving spatial information such as airplane's position and altitude with feeling on time. The study suggests that it is important to enhance perceptive skills in ATCO training in improving their expertise in predicting accuracy traffic situation, preventing from air collision, and improving productivity for more efficient air traffic flow. A further study on the relationship between the perception of spatial information and the sense of time in predicting future information and effectiveness as an independent factor would contribute to providing more insights into expertise of ATCOs.

The Development of Aerial Navigation Map and Aerial Photographic Guidance System (항공항법지도와 항공사진 촬영안내 시스템의 개발)

  • Hwang, Jin-Sang;Lee, Jae-One;Yoon, Jong-Seong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.7 no.3
    • /
    • pp.70-78
    • /
    • 2004
  • The aerial photographic mission is a difficult work because aircraft must be flown along the specified flight lines, not marked on the ground. This study has been carried out for the development of aerial photographic guidance system, which enables us to make aerial photographic task easier. Such a flight guidance system is able to display a variety of map informations in a quick and efficient way in order to guide pilot. For this purpose, we first developed the nationwide aerial navigation map database that provides the topographic map information used for topographic interpretation and aeronautical chart information used for the flight security. Next, we developed the aerial photographic guidance system which uses the aerial navigation map as base map. It is concluded that the developed system can display the various map informations quickly and do any other photographing guidance tasks well in fast moving airplane.

  • PDF