• Title/Summary/Keyword: 파 반사

Search Result 1,143, Processing Time 0.029 seconds

Design for the Reflection Free Zone with the Adequate Initial Time Delay Gap at the Control Room (음향조정실에서 적절한 초기지연시간을 갖는 무반사지역의 설계연구)

  • Rhee, Esther
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.32-41
    • /
    • 2007
  • The control room has been usually designed by the consideration of only one listening position for the sound engineer. By this study. many listening positions with the very similar acoustical condition were located in the specific region, so-called 'the reflection free zone', where the several engineer could evaluate the quality of sound at the same time. For constructing the reflection free zone, the control room has been designed by the concept of the $LEDE^{TM}$, and the initial time delay gap has been controled by the structure of control room and the properties of sound-absorbing materials. diffuser, Helmholtz resonator and image source of sound. The occurrence of any harmful phenomena like the standing wave, acoustic focusing. coloring. Hass effect and flutter echo, has greatly reduced in the reflection free zone.

Analysis of Hydrocarbon Trap in the Southwestern Margin of the Ulleung Basin, East Sea (동해 울릉분지 남서주변부의 탄화수소 트랩 분석)

  • Lee, Minwoo;Kang, Moo-Hee;Yoon, Youngho;Yi, Bo-Yeon;Kim, Kyong-O;Kim, Jinho;Park, Myong-ho;Lee, Keumsuk
    • Economic and Environmental Geology
    • /
    • v.48 no.4
    • /
    • pp.301-312
    • /
    • 2015
  • A commercial gas field was found in the southwestern continental shelf of the Ulleung Basin, East Sea in the late 1990s. To develop additional gas field, an exploration well was drilled through the coarse infill of submarine canyon near the gas field, but it was uneconomic to develop hydrocarbons. Using newly acquired deep seismic reflection and previous well data, we have identified additional geological structure which has hydrocarbon potentials below submarine canyons in the southwestern margin of the basin. Based on the interpretation of the deep seismic reflection and well data, the sequences of the study area can be classified into the syn-rift megasequence(MS1), post-rift megasequence(MS2), syn-compressional megasequence(MS3), and post-compressional megasequence(MS4) in relation to the tectonic events. MS1, deposited simultaneously with the basin formation before the middle Miocene, is characterized by chaotic seismic facies with low- to moderate-amplitude and low frequency reflections. MS2 comprises laterally continuous, low- to moderate-amplitude reflections, showing progradational stacking patterns due to high rates of sediment supply during basin expansion in the middle Miocene. MS3 is mainly composed of continuous reflections with high amplitude and moderate- to high-frequency which are interpreted as coarse-grained sediments. The coarse-grained sediments of MS3 sequence is widely truncated by several submarine canyons which filled with fine-grained sediment of MS4 to form a stratigraphic trap of hydrocarbon. Therefore, the reservoir and seal of the hydrocarbon trap in the study area are coarse-grained sediment of MS3 and submarine canyon filled with fine-grained sediment of MS4, respectively. A flat-spot seismic anomaly, which may indicate the presence of hydrocarbon, is observed within the stratigraphic trap.

A basic study on explosion pressure of hydrogen tank for hydrogen fueled vehicles in road tunnels (도로터널에서 수소 연료차 수소탱크 폭발시 폭발압력에 대한 기초적 연구)

  • Ryu, Ji-Oh;Ahn, Sang-Ho;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.517-534
    • /
    • 2021
  • Hydrogen fuel is emerging as an new energy source to replace fossil fuels in that it can solve environmental pollution problems and reduce energy imbalance and cost. Since hydrogen is eco-friendly but highly explosive, there is a high concern about fire and explosion accidents of hydrogen fueled vehicles. In particular, in semi-enclosed spaces such as tunnels, the risk is predicted to increase. Therefore, this study was conducted on the applicability of the equivalent TNT model and the numerical analysis method to evaluate the hydrogen explosion pressure in the tunnel. In comparison and review of the explosion pressure of 6 equivalent TNT models and Weyandt's experimental results, the Henrych equation was found to be the closest with a deviation of 13.6%. As a result of examining the effect of hydrogen tank capacity (52, 72, 156 L) and tunnel cross-section (40.5, 54, 72, 95 m2) on the explosion pressure using numerical analysis, the explosion pressure wave in the tunnel initially it propagates in a hemispherical shape as in open space. Furthermore, when it passes the certain distance it is transformed a plane wave and propagates at a very gradual decay rate. The Henrych equation agrees well with the numerical analysis results in the section where the explosion pressure is rapidly decreasing, but it is significantly underestimated after the explosion pressure wave is transformed into a plane wave. In case of same hydrogen tank capacity, an explosion pressure decreases as the tunnel cross-sectional area increases, and in case of the same cross-sectional area, the explosion pressure increases by about 2.5 times if the hydrogen tank capacity increases from 52 L to 156 L. As a result of the evaluation of the limiting distance affecting the human body, when a 52 L hydrogen tank explodes, the limiting distance to death was estimated to be about 3 m, and the limiting distance to serious injury was estimated to be 28.5~35.8 m.

Responses of Health Physical Fitness and Arterial Stiffness through Cigarette Smoking (흡연습관이 성인 남성의 건강관련체력 및 동맥경직도에 미치는 영향)

  • Jung, Min-Kyung;Park, Eun-Kyung;Yoo, Jae-Hyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.2
    • /
    • pp.197-205
    • /
    • 2019
  • This study was to compare arterial stiffness and hemodynamic responses between male smokers and non-smokers. This study also investigates the influences of smoking before exercise on arterial stiffness and hemodynamic responses. 24 male subjects of age 20-29 without history of cardiorespiratory disease were divided into smokers and non-smokers. Smokers had more than 5 years of smoking experience. In order to evaluate the effects of pre-exercise smoking, smokers were tested twice, once with a cigarette before the exercise and the other once without one. Data was collected from bio-impedance analysis, SphygmoCor XCEL, graded exercise test, and fitness test. Main results of this study are as follows: First, there are differences between smokers and non-smokers in cardiorespiratory and hemodynamic response functions, as shown by maximal oxygen consumption, exercise duration, and heart rate. Second, the although the arterial stiffness between smokers and non-smokers showed statistically significant differences in the speed of the pulse wave velocity and augmentation index, smoker had a faster rate. It shows that smoking behavior has a negative impact on the cardiovascular system. Third, pre-exercise smoking behavior does have an impact on cardiorespiratory and hemodynamic response functions, as shown by exercise duration and heart rate. Lastly, arterial stiffness between smokers and non-smokers showed statistically not significant in the speed of the pulse wave velocity and augmentation index. However, the difference was not statistically significant. Brachial systolic pressure, a component of pulse wave analysis, on the other hand, was significantly dependent on pre-exercise smoking behavior. Subjects who participated in this study are college students in early 20s. Given their relatively short history of smoking, it is possible that their smoking habits are not severe enough to develop into cardiorespiratory or cardiovascular diseases. But Smokers showed lower levels of cardiopulmonary functions, as maximal oxygen consumption and exercise duration than nonsmokers.

Characteristics of Micro-Particle Separation according to HRT Changes (HRT 변화에 따른 미세입자 분리 특성)

  • Ahn, Kwangho;Ahn, Jaehwan;Kim, I-Tae;Kim, Seoggu;Kang, Sungwon;Park, Eunzoo;Lee, Youngsup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.937-942
    • /
    • 2013
  • Fluid generated within the sonic or ultrasonic waves are reflected by the wall, while the opposite direction forming a predetermined sound wave to the acoustic standing wave is referred to. In this study, the frequency of 1.0 MHz and 2.0 MHz acoustic standing wave generation module is installed in a continuous particle separation device, the laminar flow of influent, taking into account the hydraulic retention time (HRT) in accordance with changes in particle separation characteristics investigated. Operation of a standing wave in the particle separation device about $1.3{\sim}2.8^{\circ}C$ temperature is increased, but did not significantly affect the formation of standing waves. During operation, the HRT 1 hr frequency 1.0 MHz 2 hr, 4 hr longer as the particle separation efficiency (turbidity) were 64.1%, 70.0%, 74.3% and, 2.0 MHz has 58.0%, respectively, depending on HRT, 61.8%, 70.7% in the respectively. That is, the same frequency, the HRT treatment efficiency is 10% or more, depending on differences in generation and, 1.0 MHz frequency, 2 hr, 2.0 MHz 4 hr at about 70% or more of the processing efficiency can be maintained. Frequency of 1.0 MHz and 2.0 MHz operation at the same time, as a result, HRT 1 hr, 2 hr, 4 hr particle separation efficiency of 63.8%, respectively, 70.6%, 77.6%, rather than the generation of standing waves appear continuous HRT is affecting a lot of particles to separate could know.

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

Magnetotelluric survey applied to geothermal exploration: An example at Seokmo Island, Korea (자기지전류법을 이용한 석모도에서의 지열자원 탐사)

  • Lee, Tae-Jong;Han, Nu-Ree;Song, Yoon-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • A magnetotelluric (MT) survey has been performed to delineate deeply extended fracture systems at the geothermal field in Seokmo Island, Korea. To assist interpretation of the MT data, geological surveying and well logging of existing wells were also performed. The surface geology of the island shows Cretaceous and Jurassic granite in the north and Precambrian schist in the south. The geothermal regime has been found along the boundary between the schist and Cretaceous granite. Because of the deep circulation along the fracture system, geothermal gradient of the target area exceeds $45^{\circ}C/km$, which is much higher than the average geothermal gradient in Korea. 2D and 3D inversions of MT data clearly showed a very conductive anomaly, which is interpreted as a fracture system bearing saline water that extends at least down to 1.5 km depth and is inclined eastwards. After drilling down to the depth of 1280 m, more than 4000 tons/day of geothermal water overflowed with temperature higher than $70^{\circ}C$. This water showed very similar chemical composition and temperature to those from another existing well, so that they can be considered to have the same origin; i.e. from the same fracture system. A new geothermal project for combined heat and power generation was launched in 2009 in Seokmo Island, based on the survey. Additional geophysical investigations including MT surveys to cover a wider area, seismic reflection surveys, borehole surveys, and well logging of more than 20 existing boreholes will be conducted.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

Highly Linear Wideband LNA Design Using Inductive Shunt Feedback (Inductive Shunt 피드백을 이용한 고선형성 광대역 저잡음 증폭기)

  • Jeonng, Nam Hwi;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1055-1063
    • /
    • 2013
  • Low noise amplifiers(LNAs) are an integral component of RF receivers and are frequently required to operate at wide frequency bands for various wireless systems. For wideband operation, important performance metrics such as voltage gain, return loss, noise figures and linearity have been carefully investigated and characterized for the proposed LNA. An inductive shunt feedback configuration is successfully employed in the input stage of the proposed LNA which incorporates cascaded networks with a peaking inductor in the buffer stage. Design equations for obtaining low and high input matching frequencies are easily derived, leading to a relatively simple method for circuit implementation. Careful theoretical analysis explains that poles and zeros are characterized and utilized for realizing the wideband response. Linearity is significantly improved because the inductor between gate and drain decreases the third-order harmonics at the output. Fabricated in $0.18{\mu}m$ CMOS process, the chip area of this LNA is $0.202mm^2$, including pads. Measurement results illustrate that input return loss shows less than -7 dB, voltage gain greater than 8 dB, and a little high noise figure around 7~8 dB over 1.5~13 GHz. In addition, good linearity(IIP3) of 2.5 dBm is achieved at 8 GHz and 14 mA of current is consumed from a 1.8 V supply.

A Study on the Model Test for Estimating Dynamic Vertical Load Added to Shallow Foundation for Machine (진동기 얕은기초에 추가되는 동적 연직하중 산정을 위한 모형실험 방안 연구)

  • Ha, Ik-Soo;Yoo, Mintaek
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.157-165
    • /
    • 2020
  • At present, there are no clearly stated criteria or theories in calculating additional vertical dynamic loads that occur at the machine foundation due to vibration and reflecting them in the design at home and abroad. According to the domestic standard, although it is not a serious vibration condition, the additional dynamic load due to vibration is considered up to 100% of the static load. This is an extremely conservative design. The purpose of this study is to propose a model test method for evaluating the quantitative magnitude of additional dynamic loads that are generated at certain static loads due to vertical mechanical vibrations. As preliminary basic tests for the model tests, the test for evaluating the effects of reflective wave that may occur within a limited size soil box and the test for estimating the natural frequency of the devised model soil-foundation system were carried out. From the analysis of results for basic tests, a method to minimize the influence of the reflected wave was prepared, and the effect of the resonance of the model system was minimized during the model tests. After the basic tests, the main model tests were conducted. Through the proposed main test, the quantitative magnitude of additional dynamic loads caused by machine vibration on a shallow foundation for machine on medium dense sand foundations were evaluated. From the results of the model test, the feasibility of design applied at home and abroad was reviewed.