• Title/Summary/Keyword: 파형로

Search Result 2,914, Processing Time 0.037 seconds

Evaluation of an insect-mimicking flapping device actuated by a piezoceramic actuator (곤충 비행원리를 모사한 압전 작동기 구동형 날갯짓 기구의)

  • 박훈철;변도영;구남서;모하메드 샤이푸딘
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.55-62
    • /
    • 2006
  • This paper presents experimental evaluation of an insect-mimicking flapping-wing device actuated by a unimorph piezoceramic actuator. Length of each rod and hinge point in the linkage/amplification system are carefully chosen such that the resulting wing motion can mimic clapping of wings in a real insect at the end of upstroke. In addition to this, a pair of corrugated wings are fabricated mimicking zig-zag cross section of a real insect wing. Thanks to the two additional implementation, the improved flapping wing device can generate a larger lift force than the previous model even though area of the new wing is about 50% less than that of the previous wing. In this work, effects of the wing clapping, the wing corrugation, and the input wave form on the lift force generation have been also experimentally investigated. Finally, the vortex generated by the flapping device has been captured by a high speed camera, showing that vortices are produced during up- and down-strokes.

Development of the Pre-amplifier and the DSP Board for the Potable EEG Biofeedback System (포터블 뇌파 바이오피드백 시스템을 위한 전치증폭기 및 DSP 하드웨어의 설계)

  • Lee, Kyoung-Il;Ahn, Bo-Sep;Park, Jeong-Je;Lee, Seung-Ha;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.121-127
    • /
    • 2003
  • In this study, we carried out a study for implementation of the pre-amplifier and the digital signal processing part for the potable EEG biofeedback system. As we consider characteristics of the EEG signal, we designed the pre-amplifier to obtain the EEG signal to be reduced noise signal. Because the EEG signal include EOG, EMG, ECG signals etc, it is difficult to analyze of the EEG signal. Therefore, we developed DSP board and operation program which was embed the LMS adaptive filter algorithm and operate with the pre-amplifier in the real time. The simulation signal and pure EEG signal is used in the experiment. As the result, we confirmed good efficiency of developed system and possibility of application to the portable EEG biofeedback system.

Quantitative Recognition of Stable State of EEG using Wavelet Transform and Power Spectrum Analysis (웨이브렛 변환과 파워스펙트럼 분석을 통한 EEG 안정상태의 정량적 인식)

  • Kim, Young-Sear;Park, Seung-Hwan;Nam, Do-Hyun;Kim, Jong-Ki;Kil, Se-Kee;Min, Hong-Ki
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.178-184
    • /
    • 2007
  • The EEG signal in general can be categorized as the Alpha wave, the Beta wave, the Theta wave, and the Delta wave. The alpha wave, showed in stable state, is the dominant wave for a human EEG and the beta wave displays the excited state. The subject of this paper was to recognize the stable state of EEG quantitatively using wavelet transform and power spectrum analysis. We decomposed EEG signal into the alpha wave and the beta wave in the process of wavelet transform, and calculated each power spectrum of EEG signal, using Fast Fourier Transform. And then we calculated the stable state quantitatively by stable state ratio, defined as the power spectrum of the alpha wave over that of the beta wave. The study showed that it took more than 10 minutes to reach the stable state from the normal activity in 69 % of the subjects, 5 -10 minutes in 9%, and less than 5 minutes in 16 %.

  • PDF

The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves (인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향)

  • 이계한;서종천
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.297-303
    • /
    • 1998
  • The sinus distal to the prosthetic heart valve influences the valve closure behavior and velocity field near the valve, therefore affects the hydrodynamic performance of the prosthetic heart valve. In order to study the effects of valve distal geometry on the hydrodynamic performance of the prosthetic valves, mechanical bileaflet valve(SJMV), monoleaflet polymer valve(MLPV) and trileaflet polymer valve(FTPV) are inserted in the test sections which have the straight and the sinus shape distal to the valve. Leakage volumes and systolic mean pressure drops are measured in the pulsatile mock circulation flow loop. Leakage volumes are slightly less and systolic mean pressure drops are higher in the sinus test section comparing to those in the straight test section, but the differences are statistically insignificant. Flow waveforms are analyzed in order to predict the valve closure behavior. The distal sinus does not affect the closure of the MLPV, but early valve closure of SJMV is observed in the sinus test section. This effect is more significant in FTPV, and the reverse flow peak of FTPV is reduced in the sinus test section. Therefore the sinus distal to the valve can reduce the reverse flow jet caused by sudden valve closure.

  • PDF

A Study on Interference Cancellation in a FM-CW Radar (FM-CW 레이다에서의 간섭 제거에 관한 연구)

  • Lee, Jong-Gil;Lee, Chang-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1856-1863
    • /
    • 2012
  • Two separate antennas are usually adopted in high performance radar systems to achieve the high degree of isolation since the transmission and reception of signals cannot be separated in time. However, even though two spatially separated antennas are installed in the system, strong signals from a transmission antenna can cause the serious interference problem in a receiving antenna. These strong interference signals from the transmission antenna can cause serious problems in detection and analysis of much weaker echo signals which are reflected by small targets. Also the increased level of background noise power due to interference can cause the serious degradation of the system performance. Therefore, in this paper, the proper cancellation method is suggested and results are shown and analyzed for removal of strong interference and background noise power.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

Wave Deformation and Blocking Performance by a Porous Dual Semi-Cylindrical Structure (투과성 이중 반원통 구조물에 의한 파 차단성능)

  • Cho, Il-Hyoung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.1
    • /
    • pp.10-17
    • /
    • 2010
  • The interaction of oblique incident waves with a porous dual semi-cylindrical structure is investigated under the assumption of linear potential theory. The porous dual semi-cylindrical structure consists of two concentric bottom-mounted cylindrical structures that are porous in front half and transparent in back half. By changing porosity, gap, and wave characteristics(wave frequencies, incidence angle), the wave blocking performance as well as the wave loads and the wave run-up are obtained. As a convenient measure of overall wave blocking performance, the root mean square(R.M.S.) of the wave elevation in a sheltered region is used. It is found that the porous semi-cylindrical structure may significantly reduce the wave response in a sheltered region and the wave forces decrease largely compared to the impermeable structure. The dual structure is more effective in reducing the wave response in a sheltered region than the mono type in the region of high frequencies.

Studies on the Physiological Chemistry of the Spring Habits in Naked Barley IV. Electrophoretic Variations in Seed Proteins during Ripening (과맥의 파성에 대한 생리화학적 연구 제4보 등숙과정에 있어서의 종자단백질의 전기영동특성 변이)

  • 최선영;이강수
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.1
    • /
    • pp.55-59
    • /
    • 1982
  • With naked barley varieties which are different in their spring habits, variations in seed proteins during ripening were checked by acrylamide gel electrophoresis. In case of 7% acrylamide gel among protein bands ⅰ-band was observed only in both Sedohadaka (intermediate type) and Wanju (spring type) throughout the ripening period, and j-band was detected in all the three varieties until 33 days after heading, but not in Nonsangwa (winter type) thereafter. In case of 6M urea-7% acrylamide gel z-band was traced only in Nonsangwa, contrary to i-band, throughout the ripening period. U-band was observed in all the three varieties until 23 days after heading, but not in Nonsangwa thereafter. X-band showed opposite from u-band. Throughout the ripening period Sedohadaka was significantly more similar in the electrophoretic patterns to Wanju than to Nonsangwa.

  • PDF

Influence of valve plate configuration on torque ripple of a bi-directional bent-axis type hydraulic piston pump (양방향 회전형 사축식 유압 피스톤 펌프의 벨브 플레이트 형상이 토크 맥동에 주는 영향)

  • Kim, Sung-Hun;Hong, Yeh-Sun;Kim, Doo-Man
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.231-237
    • /
    • 2007
  • The torque ripple of the hydraulic pumps for the Electro-hydrostatic Actuators can disturb the cylinder position control under slewing speed operation condition. In principle, the periodic change of the reaction torque generated by a piston type pump is highly dependent on the waveform of its cylinder chamber pressure. In case of uni-directional pumps operating at constant speed, the transient overshoot and rising slope of the cylinder pressure can be adjusted by the precompression angle and notch shape of their valve plates. Therefore, the influence of the valve plate geometry on the torque ripple magnitude of a bent-axis type piston pump for EHA application was investigated in this study. The results showed that any improvement of the torque ripple of such a bi-directional pump can not be achieved by modifying the valve plate geometry, regardless of its operation speed.

Estimation of the Blood Pressure Using Point Variation Aspect of Dicrotic Notch on Pulsating Waveform at Each Cardiac Periods (주기별 맥동파형의 절흔점 위치변화 특성을 이용한 혈압 추정)

  • Baik, Seongwan;Park, Sungmin;Shon, Jungman;Park, Geunchul;Lee, Sanghoon;Jang, Wooyoung;Jeon, Ahyoung;Jeon, Gyerok
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the study, novel blood pressure estimation method was proposed to improve the accuracy of oscillometric method. The proposed algorithm estimated the blood pressure by comparing and analyzing the point variation aspect of dicrotic notch on pulsating waveform during each cardiac cycle. The waveforms of each cardiac cycle were extracted by maximum points. The extracted pulsating waveforms were applied by re-sampling, end-matching, and normalization. The systolic and diastolic blood pressures were estimated by point variation aspect of dicrotic notch. The blood pressures, which were estimated from proposed algorithm, were compared and analyzed by blood pressures from oscillometric methods and auscultation. The systolic blood pressure from oscillometric methods were +0.88 mmHg more than proposed algorithm, and 1.875 less than the diastolic blood pressures from proposed algorithm. The systolic and diastolic blood pressures from auscultation were 2.89 mmHg and 3.44 mmHg less than the blood pressures from proposed algorithm. As the errors between blood pressures from proposed algorithm, oscillometric method and auscultation were less than 5 mmHg, the proposed algorithm was effective.