• Title/Summary/Keyword: 파절시간

Search Result 81, Processing Time 0.019 seconds

Difference of visiting time and major cause of disease by operating time changes of a university dental emergency room (일개 치과대학병원 응급실 운영시간 변경에 따른 환자의 방문시기와 주요상병의 차이)

  • Noh, Hie-Jin;Mun, So-Jung;Jeon, Hyun-Sun;Bae, Sung-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.661-669
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate of visiting time and major cause of disease by operating time changes of a university dental emergency room. Methods: This study was a retrospect study carried out by reviewing 9,172 records visiting the university emergency room from January 1997 to December 2009. Data were analyzed by frequency test, chi-square test, and logistic regression using SAS version 9.3. Results: Twenty four hours emergency room had 19 percent more patients than those in daytime emergency room. Daytime emergency room had more male patients during spring(26.6%) and winter(20.2%) than female patients(p<0.05). Female patients exceeded male patients during summer(24.4%) and autumn(36.2%)(p<0.05). Twenty-four hours emergency room had the maximal patients in autumn and the minimal patients in winter(p<0.05). The most common injury in the daytime was tooth fracture from 0 to 19 years old(p<0.05). Tooth fracture, jaw fracture, and soft tissue injury were the most common injury in dental emergency room and majority of the patients were the male(p<0.05). Conclusions: Twenty-four hours dental emergency room had a variety of causes of dental emergency thant that in the daytime. Twenty four hours dental emergency room must be prepared for the dental emergency patients at any time provided with personnel and facilities.

Mechanical Properties of (Y, Nb)-TZP/Alumina Composites for Dental Implant Abutments (치과 임플란트 상부구조물용 (Y, Nb)-TZP/알루미나 복합체의 기계적 물성)

  • 정형호;김대준;한중석;이득용
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.7
    • /
    • pp.508-512
    • /
    • 2004
  • For abutment of dental implants, (Y, Nb)-TZP/Alumina composites were prepared by addition of 10-90 vol% alumina at an interval of 10 vol% into tetragonal zirconia solid solution which consists of 90.24 mol% Zr $O_2$, 5.31 mol% Y$_2$ $O_3$, and 4.45 mol% Nb$_2$O$\_$5/. Biaxial flexure strength and fracture toughness of composite were optimized by adding 10 vol% alumina, which resulted in 900 MPa and 8.9 MPam$\^$1/2/, respectively. The composite did not undergo low temperature degradation even after autoclave treatment at 200$^{\circ}C$ for 10 h. 65 of (Y, Nb)-TZP/Alumina composite abutments were employed into 40 patients and any adverse reaction, screw loosing, or fracture of abutments was not observed for the span of 2 years, indicating that the ceramic abutments can be safely used for restorations.

A COMPARATIVE STUDY ON SHEAR BOND STRENGTHS INFLUENCED BY TIME ELAPSED AFTER BRACKET BONDING WITH A LIGHT-CURED GLASS IONOMER CEMENT (광중합형 글래스아이오노머 시멘트의 브라켓 접착후 시간 경과에 따른 전단결합강도의 비교연구)

  • Lee, Ki-Soo;Lim, Ho-Nam;Park, Young Guk;Shin, Kang-Seob
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.605-611
    • /
    • 1995
  • The purpose of this study was to evaluate effects of time on shear bond strengths of a light-cured glass ionomer cement and chemically cured resin cement to enamel, and to observe the failure patterns of bracket bondings. Shear bond strength of a light-cured glass ionomer cement were compared with that of a resin cement. Metal brackets were bonded on the extracted human bicuspids. Specimens were subjected to a shear load(in an Instron machine) after storage at room temperature for 5 and 15 minutes; after storage in distilled water at $37^{\circ}C$ for 1 or 35 days. The deboned specimens were measured In respect of adhesive remnant index. The data were evaluated and tested by ANOVA, Duncan's multiple range test, and t-test, and those results were as follows. 1. The shear bond strength of light-cured glass ionomer cement is higher than that of resin cement at 5 and 15 minutes. 2. The shear bond strengths of both light-cured glass ionomer cement and resin cement increase with time. There was no significant difference in those of both 1 day group and 35 day group 3. Light-cured glass ionomer cement is suitable as orthodontic bracket adhesives

  • PDF

A STUDY ON THE TRAUMATIC INJURIES TO PRIMARY TEETH (유치 외상에 관한 연구)

  • Chung, Youn-Joo;Kim, Kwang-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.328-337
    • /
    • 2010
  • The purpose of this study was to research the traumatized primary teeth and investigate following factors: sex, age, cause, place and time(of the year) of injury, elapsed time, area and type of injury, dental treatment and prognosis. The analysis includes total of 1533 traumatized primary teeth from 758 children aging from 6 months to 6 years(mean age: 2.8) from 2003 to 2007. The result follows : 1. The children of age between 1-2 and 2-3 were involved in the largest number of injuries in both sexes with boy/girl ratio of 1.77:1(p<0.001). 2. Fall and collision were the main causes of traumatic dental injury, especially in younger children(p<0.05). Places of injury occurrence varied: home, outdoors, and kindergarten. Warm climate accounts for frequent outdoor injuries in May, September and October(p<0.001). 3. Most of the children visited dental clinic within 24 hours of the injury(77.6%). From March to September, dental trauma occurrences were distributed evenly, except for Winter period(p<0.001). 4. Upper central incisors were the most commonly affected teeth, and the injuries usually involved 1 tooth or 2 teeth. 5. Periodontal tissue injuries dominated and subluxation was the most common type. Lateral luxation, enamel fracture, intrusion and root fracture followed.

Fabricating retrofit crowns to an existing removable partial denture by CAD-CAM: a case report (CAD-CAM을 이용한 RPD 지대치의 retrofit crown 제작 증례)

  • Hyuksoon Lee;Seong-A Kim;Joo-Hyuk Bang;Sung Yong Kim;Hee-Won Jang;Keun-Woo Lee;Yong-Sang Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.140-145
    • /
    • 2024
  • Removable partial denture wearers are exposed to the risks that remaining teeth get damaged by caries, attritions, erosion, and fracture. In the case of damaged abutment tooth which should fit to Removable partial denture (RPD), the fabrication of surveyed crown is followed by the making of RPD. However, making new denture takes a long time, and needs several processes and costs. Also, patients should get used to new denture. If other abutment teeth and edentulous ridges provide the existing denture with support, retention, and stability, use of existing denture is considered clinically acceptable. In this situation, fabricating retrofit crowns to an existing removable partial denture makes patient use existing denture, cuts costs, and reduces discomfort. In this case, severely worn teeth were restored using monolithic zirconia crown which fit to an existing removable partial denture by CAD-CAM. Moreover, support, retention, and stability of the denture were improved, and both doctor and patient were satisfied with the result.

A comparative study on bond strength and adhesive failure pattern in bracket bonding with self-etching primer (Self-etching Primer를 이용한 교정용 브라켓 부착시 전단결합강도와 파절양상에 관한 비교연구)

  • Kim, You-Kyoung;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.325-332
    • /
    • 2004
  • A self-etching primer that combines the etchant and primer in one chemical compound saves time and should be mote cost-effective to the clinician and patient. The purpose of this study was to evaluate the clinical effectiveness of a self-etching primer by measuring shear bond strengths according to various conditions and observing adhesive failure patterns. For this Investigation, 120 upper and lower premolars extracted for orthodontic purposes were used and randomly divided into six groups of twenty teeth each. Human premolars were embedded in a metal cylinder with orthodontic resin. Metal brackets and ceramic brackets were bonded with XT primer and self-etching primer by means of XT adhesive. Upon curing, plasma arc light and visible light were used. After bonding, the shear bond strength was tested by Instron universal testing machine, and the amount of residual adhesive that remained on the tooth after debonding was measured by stereoscope and assessed with an adhesive remnant index. The results were as fellows: 1. When brackets were bonded, if other conditions remained the same, there was no significant difference in shear bond strength due to the type of primer - either self-etching primer or XT primer. 2. When metal brackets were bonded, there was no significant difference in shear bond strength according to the source of light - plasma arc light or visible light - and type of primer. 3. There was a very significant difference in shear bond strength according to the type of brackets - metal or ceramic brackets. The shear bond strength of ceramic brackets was stronger than metal brackets. 4. When the adhesive failure patterns of metal brackets bonded with self-etching primer were observed by using the adhesive remnant index, the bond failure of the metal bracket occurred more frequently at the bracket-adhesive. The failure of the ceramic bracket, however, occurred more frequently at the enamel-adhesive interface. The adhesive failure patterns of metal brackets bonded with XT primer observed the same patterns. The above results suggest that self-etching primer can be clinically useful for bonding the brackets without fear of a decrease in shear bond strength.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

TRAUMATIC INJURIES TO THE UPPER INCISORS IN PRIMARY AND MIXED DENTITION (유치열과 혼합치열기 어린이의 상악 절치부 외상)

  • Chung, Chu-Hyun;Lee, Jae-Ho;Kim, Seong-Oh;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.290-298
    • /
    • 2004
  • In children, change in lifestyles such as an increase in participation of physical activities has increased the chance of receiving an injury, harming the child and their parents. This study was carried out to give basic information of traumatic injuries to the upper anterior teeth which can be used in prevention of future complications that may arise. From June, 2002 to May, 2003, of the 8,799 children in their primary and mixed dentition visiting Department of Pediatric Dentistry, College of Dentistry, Yonsei University 955 upper anterior teeth(primary 543, permanent 412) of 487 children(male 316, female 171) with traumatic injures to the upper incisors were studied. The results were as follows: 1. Trauma to the primary teeth prevailed at the age of 1-3 and to the permanent teeth at the age of 7. The male to female ratio was 1.85:1. 2. Trauma to the upper incisors for both the primary and permanent teeth occurred in the afternoon. Primary teeth were injured most frequently in the home(44.1%) and the permanent teeth outdoors, in the street(17.5%). 3. Both the primary and permanent teeth were most injured by fall-down injuries(39.8%, 12.9%), and next were collisions(22.2%, 6.0%). For the primary teeth, high fall, traffic accident, violence and sports are next in order, and for the permanent teeth, violence, sorts, traffic accidents were next. 4. Average number of 1.6 primary teeth and 2.8 permanent teeth were injured with the right central incisor most prevailing. 5. Crown fracture without pulpal exposure and subluxation injures were highest in frequency in both the primary and permanent teeth.

  • PDF

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

MOLAR RESTORATION WITH AN ORTHODONTIC BAND (교정용 밴드를 이용한 구치부 수복)

  • Lee, Suk-Woo;Lee, Jae-Ho;Choi, Hyung-Jun;Sohn, Hyung-Kyu;Kim, Seong-Oh;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.91-95
    • /
    • 2009
  • The use of stainless steel crowns are indicated for restoration of primary or permanent molars with proximal dental caries, extensive dental caries, or previous pulp treatment with increased danger of tooth fracture. Stainless steel crowns were introduced by Humphrey in 1950. For their improved durability, longevity, and success rate, they have been strongly considered for restoring extensive and multi-surfaced dental caries of molars in pediatric dentistry. However, they also have shortcomings, such as possibility of pulpal exposure or damaging proximal surface of adjacent teeth. In addition, when oversized stainless steel crowns are used, eruption of the adjacent permanent teeth may be disturbed by their prominent margin. As a means to compensate the shortcomings of stainless steel crowns, use of orthodontics bands may be considered. It is an alternative restoration method, where an orthodontic band is placed on a tooth first and cavity is restored with filling material, such as composite resin, glass ionomer, or amalgam. The use of an orthodontic band is indicated for molar restoration with cervical dental caries, extensive dental caries, enamel hypoplasia, or previous pulp treatment. Because it requires shorter chair time compared to stainless steel crown, its application is very useful for children with poor behavior. However, restoration using an orthodontic band requires good oral hygiene after its application. This case report illustrates the conservative restoration of primary molars and permanent molars with extensive dental caries using orthodontic bands.

  • PDF