• 제목/요약/키워드: 틈새체적

검색결과 11건 처리시간 0.029초

전기점화 기관 간극 체적 내 미연탄화수소의 산화 모델링 (Modeling of Piston Crevice Hydrocarbon Oxidation in SI Engines)

  • 최회명;김세준;민경덕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.884-889
    • /
    • 2001
  • Combustion chamber crevices in SI engines are identified as the largest contributor to the engine-out hydrocarbon emissions. The largest of crevice region is the piston ring pack crevice. To predict and understand the oxidation process of piston crevice hydrocarbons, a 3-dimensional numerical simulation method was developed. A engine shaped computational mesh with moving grid for piston and valve motions was constructed. And a 4-step oxidation model involving 7 species was used and the 16 coefficients in the rate expressions were optimized based on the results from a detailed chemical kinetic mechanism for the oxidation condition of engine combustion chamber. Propane was used as a fuel in order to eliminate oil layer absorption and liquid fuel effect.

  • PDF

보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사 (Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제24권2호
    • /
    • pp.100-105
    • /
    • 2015
  • 온실의 난방부하 중 틈새환기전열부하 산정방법은 설계 기준마다 제각각이고, 온실의 규모에 따라 각각의 방법에는 큰 차이가 있으므로 보다 정확히 국내에 적용할 수 있는 방법을 정립할 필요가 있다. 본 연구에서는 원예시설의 환경설계 중 난방부하 산정방법 정립에 필요한 기초자료를 제공할 목적으로 다양한 종류의 보온커튼을 설치한 단동 및 연동 플라스틱 온실에서 추적가스법을 이용하여 틈새환기율을 실측하였으며, 온실의 틈새환기 전열부하 산정방법을 검토하였다. 연동온실의 틈새환기율은 $0.042{\sim}0.245h^{-1}$의 범위로 측정되었으며 단동온실의 틈새환기율은 $0.056{\sim}0.336h^{-1}$의 범위로 측정되어 단동온실이 약간 큰 것으로 나타났다. 온실의 틈새환기율은 단동, 연동 구분없이 보온커튼의 층수에 따라 크게 감소하는 것으로 나타났다. 또한 틈새환기율은 온실의 실내외 기온차가 커질수록 증가하는 경향을 보였으나, 실험기간 동안의 낮은 풍속 범위에서 외부 풍속에 따른 틈새환기율의 변화는 일정한 경향을 찾을 수 없었다. 온실의 난방설계를 위한 틈새환기율은 적정 실내외 기온차에서의 값을 제시할 필요가 있고, 최대난방부하 산정의 기준이 되는 낮은 풍속 범위에서 풍속에 따른 틈새환기율의 변화는 고려하지 않아도 되는 것으로 고찰되었다. 다만 강풍지역에서는 열관류율을 포함하여 최대난방부하를 약간 증가시키는 보정계수의 적용이 필요할 것으로 판단되었다. 온실의 틈새환기전열부하 산정방법을 검토한 결과 틈새환기전열계수와 온실의 피복면적을 이용하는 방법은 문제가 있는 것으로 나타났으며, 틈새환기율과 온실의 체적을 이용하는 방법이 합리적인 것으로 판단되었다.

유압 Vane Pump의 성능특성에 관한 연구

  • 김병술;이일영;정재연
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 춘계학술대회 논문집
    • /
    • pp.335-340
    • /
    • 1992
  • 유압 시스템(System)은 원동기의 기계적 에너지를 유압펌프가 작동유를 압력 에너지의 형태로변환 시켜 이것을 유합 실린더(Cylinder)등의 엑츄에이터(Actuator)가 다시 기계적 에너지로 변환시켜 부하 를 구동하게한다. 상용차(NT-1, KH 등)용 파워스티어링(Power Steering)에 장착되는 Vane Type Oil Pump (이하 VOP)가 바로 이와같은 역할을 담당하고 있다. 본 연구에서는 VOP의 성능과 관련되어지는 주요 제원(Parameter)인 미끄럼부에서의 틈새, 작동유점도, 압력변화, 회전수 등을 다양하게 변화시키는 모의실험(Simulation)을 통하여각각의 조건하에서얻어지는 누설 유량과 체적효율을 수치적 으로 예측하고 이것을 주요제원을 고려하여 해석해서 정량적인 값을 얻는 것을 목적으로한다.

프리피스톤 수소기관의 역화 및 이상연소에 관한 연구 (A Study on the Backfire and Abnormal Combustion in the Free-piston Hydrogen Fueled Engine)

  • 김강문;박상욱;이제홍;노기철;이종태;이용균
    • 한국수소및신에너지학회논문집
    • /
    • 제17권1호
    • /
    • pp.1-7
    • /
    • 2006
  • The free-piston hydrogen fueled engine is estimated as the next generation power system which can obtain high efficiency and low emission, simultaneously. In order to develop the free-piston hydrogen fueled engine, it is necessary to stable the combustion. The engine combustion, backfire and knock phenomenons were studied by using RICEM for researching combustion characteristics of free-piston engine. As the results, backfire occurrence was not observed in the free-piston engine under limited experimental condition. And knocking occurred in case of higher cylinder wall temperature.

개선된 단일영역 열발생량 계산법을 사용한 소형 HSDI와 IDI엔진의 연소특성 비교에 관한 연구 (A Study on the Comparison of the Combustion Characteristics between a Small HSDI and an IDI Diesel Engine by Advanced One-zone Heat Release Analysis)

  • 이석영;정구섭;전충환;장영준
    • 한국자동차공학회논문집
    • /
    • 제12권6호
    • /
    • pp.46-53
    • /
    • 2004
  • Heat release analysis is a very important method for understanding the combustion phenomena inside an engine cylinder. In this study, one-zone heat release analysis was used with the measured cylinder pressures of a HSDI(high speed direct injection) and IDI(indirect injection) diesel engines, Those have benefits of simple equation, fast speed, reliability. The objective of the study is to compare the combustion characteristics between a HSDI and an IDI. The result shoes that the maximum heat release rate of a HSDI is higher than that of an IDI because of long ignition delay period. The heat release curve of an IDI is more linear than that of a HSDI, thus is similiar to that of a SI engine. The combustion efficiency of a HSDI is higher than that of an IDI because of the smaller heat transfer loss of a HSDI. There is a suggestion here that an IDI engine has broad heat transfer area which include two combustion chambers, the connection passage of combustion chambers, etc.

프리피스톤 수소기관의 연소안정화 및 성능향상에 관한 연구 (A Study on the Combustion Stabilization and Performance Improvement in the Free-piston Hydrogen Fueled Engine)

  • 노기철;윤재성;김강문;박상욱;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.227-233
    • /
    • 2006
  • A free-piston hydrogen fueled engine is considered as one of the next power systems which is able to obtain high efficiency and low emission, simultaneously. In this study, in order to ensure the possibility as the next generation power system, the combustion characteristics and the performance of the free-piston hydrogen fueled engine are analyzed by using the linear RICEM for the change of injection pressure and equivalence ratio. As the results, in-cylinder maximum pressure is shown at injection pressure $P_{inj}$=6bar. Backfire phenomenon is not observed under experimental condition and knock occurs over ${\Phi}=0.8$. The thermal efficiency is the highest at injection pressure, $P_{inj}$=6bar and equivalence ratio, ${\Phi}=0.7$, respectively.

축류송풍기의 삼차원 유동장 해석 (Three-dimensional analysis of the flow through an axial-flow fan)

  • 김광용;김정엽;정덕수
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.541-550
    • /
    • 1997
  • Computational and experimental investigations on the three-dimensional flowfield through an automotive cooling fan are carried out in this work. Steady, incompressible, three-dimensional, turbulent flow through a rotating axial-flow fan is analyzed with Reynolds averaged Navier-Stokes equations and standard k-.epsilon. turbulence model. The governing equations are discretized with finite-volume approximations in non-orthogonal curvilinear coordinates. Computational static pressures on the casing wall agree well with the experimental data which are measured in this work. And, they are sensitive to the change of tip clearance. The flowfield is not significantly affected by the thickness of the blade. The k-.omega. model gives the static pressure rise on the casing wall which is similar to that with the k-.epsilon. model.

온실 난방부하 산정방법의 검증 및 틈새환기와 지중전열의 영향 분석 (Validation of Load Calculation Method for Greenhouse Heating Design and Analysis of the Influence of Infiltration Loss and Ground Heat Exchange)

  • 신현호;남상운
    • 원예과학기술지
    • /
    • 제33권5호
    • /
    • pp.647-657
    • /
    • 2015
  • 원예시설의 환경설계 중 난방부하 산정방법에 대한 검증을 위하여, 대규모 플라스틱 온실에서 총난방부하와 틈새환기율, 지중전열량을 계측하여 계산결과와 비교 분석하였고, 지중전열 및 틈새환기가 온실의 난방부하에 미치는 영향을 검토하였다. 실험기간 동안 실내기온은 $13.3{\pm}1.2^{\circ}C$, 실외 기온은 $-9.4{\sim}+7.2^{\circ}C$의 범위를 보였으며, 우리나라의 난방 설계 외기온 범위에서 유효한 것으로 확인하였다. 가스트레이서법으로 측정한 틈새환기율은 평균 $0.245h^{-1}$로 나타났다. 온실의 피복면적에 일정한 환기전열계수값을 사용하는 방법은 온실의 규모에 따라서 문제가 있는 것으로 분석되었다. 따라서 환기전열부하는 온실의 체적과 틈새환기율을 이용하는 방법이 합리적인 것으로 판단된다. 온실 중앙에서 측정한 지중열류는 실내외 기온차에 따라 음으로 약간 증가하는 경향을 보이고, 온실 측면에서 측정한 지중열류는 실내외 기온차에 따라 양으로 크게 증가하는 경향을 보였다. 계측 결과를 바탕으로 온실의 외주부를 통한 열손실 개념을 도입한 새로운 지중전열부하 산정 방법을 개발하였으며, 검증결과 잘 일치하는 것으로 나타났다. 관류열부하는 대체로 실내외 기온차에 비례하는 것으로 나타났으나, 열관류율은 작아지는 경향을 보였다. 따라서 관류열부하 산정시 설계조건에 따라 열관류율의 선택에 주의를 기울여야 할 것으로 판단된다. 실험온실의 열관류율은 평균 $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$로 단일피복의 플라스틱 온실 대비 60%의 열절감율을 보이는 것으로 나타났다. 전체 난방부하 중에서 관류열부하가 84.7~95.4%, 환기전열부하가 4.4~9.5%, 지중전열부하가 -0.2~+6.3%를 차지하는 것으로 나타났다. 관류열부하는 실내외 기온차가 낮은 그룹에서 더 큰 비율을 차지하고, 환기전열 부하는 실내외 기온차가 높은 그룹에서 더 큰 비율을 차지하는 것으로 나타났다. 지중전열부하의 경우 실내외 기온차가 낮은 그룹에서는 부하를 경감시키는 방향으로 작용하고, 실내외 기온차에 따라 부하를 증가시키거나 경감시키는 방향으로 작용하는 것으로 나타났으므로 이 기준 온도차의 선택이 중요한 것으로 판단된다. 지중전열부하에 비하여는 환기전열부하가 더 큰 비중을 차지하므로 에너지 절감을 위해서는 틈새환기율을 줄일 수 있는 대책이 필요한 것으로 판단된다.

루프소기방식을 갖는 2행정 프리피스톤 수소기관의 역화에 관한 연구 (Study on Backfire for a Two-Stroke Hydrogen Fueled Free-Piston Engine with Loop Scavenging)

  • 조관연;변창희;백대하;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.487-492
    • /
    • 2010
  • For developing a two-stroke free-piston hydrogen engine with high efficiency and low emission, determination of the scavenging type is one of the most important factor. In this research, backfire characteristics for loop scavenging were analyzed with the number of piston crevice volume and piston expansion speed. Rapid Compression Expansion Machine, RCEM was used for combustion research of the free piston $H_2$ engine in the experiment. As the results, it was shown that although backfire occurring in a loop scavenging type can be partially controled by a complete exhaust of burned gas, possibility of backfire basically exist due to the structure which piston crevice volumes contact with fresh mixture in a scavenging port. However, a loop scavenging may be considered as combustion chamber of a free piston $H_2$ engine from the point of view that backfire does not occur nearby lean equivalence ratio obtained high thermal efficiency. It was also analyzed that an advances of backfire occurrence timing with increase of the fuel-air equivalence ratio were due to promotion of flame propagation into piston crevice volumes by decrease of the quenching distance.

저비속도 원심 회전차 외경가공에 따른 축추력 불균형을 감쇄시키기 위한 평형 피스톤 수정방안에 관한 고찰 (Modification of Balancing Piston for Trimming of Impeller Diameter for Maintaining Axial-Thrust Balance in Low-Specific-Speed Multistage Centrifugal Pumps)

  • 유일수;박무룡;윤의수
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.875-882
    • /
    • 2011
  • 회전차 외경 가공에 따른 축추력 평형 및 체적 효율 변화에 대하여 고찰하였다. 평형장치로 평형피스톤이 장착된 저비속도 다단 원심 펌프를 연구 대상으로 해석을 수행하였다. 수평축 다단 펌프와 2종의 수직축 다단 펌프에 대해 해석 수행을 한 결과, 회전차 외경 가공에 의해 펌프 전방으로 추가적인 축추력이 발생하였다. 이러한 축추력 불균형은 수평축 펌프보다 수직축 펌프에서 크게 발생하였다. 축추력 불균형을 방지하기 위해 평형피스톤의 외경을 증가시키는 방안을 제시하였고, 이를 위해 필요한 평형피스톤의 직경 변화율을 산출하였다. 피스톤의 직경 변화량은 회전차 외경 가공률에 비례하여 증가하였다. 피스톤 직경 변화량이 클수록 틈새 면적 증가로 인해 체적효율이 감소하므로, 피스톤의 길이를 함께 증가시켜 체적 효율의 감소를 방지하는 것이 효과적이다.