• Title/Summary/Keyword: 특성 이완 시간

Search Result 104, Processing Time 0.137 seconds

Properties of photoluminescence and time-resolved photoluminescence in doped GaAs (도핑된 GaAs의 형광 및 시간분해 형광 특성)

  • 추장희;서정철;유성규;신은주;이주인;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.213-217
    • /
    • 1997
  • We have measured photoluminescence (PL) and time-resolved PL in doped-GaAs. As increasing doping concentration, the PL spectra of n-type GaAs shift to higher energies while the PL spectra of p-type GaAs shift to lower energies than the bandgap of the undoped GaAs. The contribution of the Burstein-Moss effect overrules the band-gap narrowing in n-type GaAs, contrary to p-type GaAs. The PL rise time and decay time become shorter as increasing doping concentration. The PL rise and decay time in doped-GaAs depend on the type of majority carriers and their concentrations, which imply that the carrier-carrier interaction plays an important role in the energy relaxation processes.

  • PDF

Characteristics of Virtual Reflection Images in Seismic Interferometry Using Synthetic Seismic Data (합성탄성파자료를 이용한 지진파 간섭법의 가상반사파 영상 특성)

  • Kim, Ki Young;Park, Iseul;Byun, Joongmoo
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.2
    • /
    • pp.94-102
    • /
    • 2018
  • To characterize virtual reflection images of deep subsurface by the method of seismic interferometry, we analyzed effects of offset range, ambient noise, missing data, and statics on interferograms. For the analyses, seismic energy was simulated to be generated by a 5 Hz point source at the surface. Vertical components of particle velocity were computed at 201 sensor locations at 100 m depths of 1 km intervals by the finite difference method. Each pair of synthetic seismic traces was cross-correlated to generate stacked reflection section by the conventional processing method. Wide-angle reflection problems in reflection interferometry can be minimized by setting a maximum offset range. Ambient noise, missing data, and statics turn to yield processing noise that spreads out from virtual sources due to stretch mutes during normal moveout corrections. The level of processing noise is most sensitive to amplitude and duration time of ambient noise in stacked sections but also affected by number of missing data and the amount of statics.

Ginseng Saponins Enhance Maxi $Ca^{2+}-activated\;K^+$ Currents of the Rabbit Coronary Artery Smooth Muscle Cells

  • Chunl Induk;Kim Nak-Doo
    • Journal of Ginseng Research
    • /
    • v.23 no.4
    • /
    • pp.230-234
    • /
    • 1999
  • Potassium channels play an important role in regulating vascular smooth muscle tone. Four types of $K^+$ channels areknown to be expressed in vascular smooth muscle cells, and maxi $Ca^{2+}-activated\;K^+$ channel $(BK_{Ca})$ is a dominant type of $K^+$ channels in these cells. Because total ginseng saponins and ginsenoside $Rg_3$ cause vasodilation with unclear mechanisms, we hypothesized that total ginseng saponins and ginsenoside $Rg_3$ induce vasodilation via activation of maxi $Ca^{2+}-activated\;K+$ channels. Whole-cell BKe. currents were voltage-dependent with half maximum activation at -14 mV, and the currents were sensitive to nanomolar ChTX and millimolar TEA. External application of total ginseng saponins increased the anlplitude of the whole-cell BKe. current in a concentration-dependent manner. Single-channel analysis indicates that total ginseng saponins caused the channel opening for a longer period of time. Ginsenoside $Rg_3$ increased the amplitude of whole-cell $K_{Ca}$ currents without affecting voltage dependence of the currents and increased single-channel open time. Hence, the results suggest that ginseng saponin-induced vasodilation may be due to activation of $K_{Ca}$.

  • PDF

A Structural Behaviour Analysis System for Simulating the Construction Steps of Prestressed Concrete Bridges (시공단계를 고려할 수 있는 프리스트레스트 콘크리트 교량 전용 거동해석 시스템)

  • 안경한;김대영;이환우;김덕경;김우종;김철영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1991.10a
    • /
    • pp.96-101
    • /
    • 1991
  • 프리스트레스트 콘크리트 교량은 콘크리트와 PS 강재의 역학적 장점들을 십분 활용하여 경제적인 단면 구성이 가능한 반면, 서로 다른 두 재료의 복합적인 특성들 즉, 콘크리트의 크리이프 (creep), 건조수축 (shrinkage)과 PS 강재의 이완 (relaxation) 등과 같이 시간에 따라 변화하는 인자들로 인하여 복잡한 구조적 거동을 보여 해석상 어려움이 따른다. 이와같은 복합거동은 시공순서와 시공방법에 의해 시공중의 구조계와 지지조건 등이 변화하는 경우에는 더욱 복잡한 양상을 띄게 된다. 뿐만 아니라 박스 거더와 같은 박벽요소에서는 일반적인 보요소(beam element)로는 나타낼 수 없는 ?(warping)을 무시할 수 없으므로 ? 자유도를 구현할 수 있는 특수한 기능의 구조해석용 프로그램의 개발이 절실히 요망된다. 그리고 시공단계별로 출력되는 많은 양의 수치결과들을 설계와 시공실무자에 지향된 형태로 조합, 변형시켜 그래픽 화면상에 나타내는 후처리 프로그램(Post-processor) 기능도 구조해석용 프로그램의 개발 못지않게 중요하다. 본 연구의 목적은 삼성종합건설과 서울대 토목공학과가 공동으로 ?(warping) 자유도를 포함한 7개의 자유도를 갖는 3차원 보요소를 사용하여 PS 콘크리트의 재료적 특성인 크리이프와 건조수축, 그리고 강재의 이완(relaxation)을 포함한 프리스트레싱력의 손실을 고려할 수 있고 시공 단계별 구조계의 변화 및 지지조건들의 다양한 변화를 효율적으로 모사할 수 있는 프로그램의 개발에 있다.

  • PDF

Dynamic Capacity Allocation Scheme for Interactive GEO Satellite Networks (대화형 GEO 위성 네트워크를 위한 동적 용량 할당 체계)

  • Jang Geun-Nyeong
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.1042-1047
    • /
    • 2006
  • 본 논문에서는 대화형 GEO 위성 네트워크의 데이터 손실량과 데이터 지연량을 최소화하기 위한 리턴 링크 용량 할당 체계를 제시한다. 데이터의 지연 특성에 따라 구분되는 각 데이터 유형별로 데이터 손실량 기대값과 데이터 지연량 기대값을 분석하고, 데이터 손실량 기대값과 데이터 지연량 기대값의 가중합을 최소화하는 리턴 링크 용량 할당 모형을 제시한다. 또한, 제시한 모형을 빠른 시간 내에 해결할 수 있는 라그랑지안 이완 기법을 이용한 동적 용량 할당 체계를 제시한다.

  • PDF

Ultimate Analysis of Prestressed Concrete Cable-Stayed Bridges (프리스트레스트 콘크리트 사장교의 극한해석)

  • Lee, Jae Seok;Kang, Young Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.5
    • /
    • pp.85-98
    • /
    • 1993
  • A method of analysis for the material and geometric nonlinear analysis of planar prestressed concrete cable-stayed bridges including the time-dependent effects due to load history, creep, shrinkage, aging of concrete and relaxation of prestress is described. The analysis procedure, based on the finite element method, is capable of predicting the response of these structures through elastic, cracking, inelastic and ultimate ranges. The nonlinear formulation for the description of motion is based on the updated Lagrangian approach. To account for the material nonlinearity, nonlinear stress-strain relationship and cracking of concrete, nonlinear stress-strain relationships of reinforcing steel, prestressing steel, and cable, including load reversal are given. Results from a numerical examples on ultimate analyses of cable-stayed bridges are presented to illustrate the analysis method.

  • PDF

An experimental study on the characteristic times of viscoelastic fluids by falling ball viscometer (낙구식 점도계를 이용한 점탄성 유체의 특성시간에 관한 실험적 연구)

  • 전찬열;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.241-250
    • /
    • 1990
  • Characteristic relaxation time and characteristic diffusion time of viscoelastic fluids are determined experimentally by measuring the zero-shear-rate viscosity by falling ball viscometer and the infinite-shear-rate viscosity by capillary tube viscometer. Fluids used in experiments are aqueous solutions of polyacrylamide Separan AP-273 and the polymer concentrations range from 300 to 2000 wppm. A newly designed laser beam and timer system is employed to overcome the difficulty in measuring terminal velocities of the low concentration solutions. Ball removal device is prepared to remove the dropped ball from the bottom of cylinder without disturbing the testing fluid. In order to measure the zero-shear-rate viscosity, densities of hollow aluminium balls are adjusted very close to the densities of testing fluids. Characteristic diffusion time, which is ball viscometer. However, terminal velocity of a needle by falling ball viscometer is not affected by the time interval of dropping needles and characteristic diffusion time is not measured with a dropping needle. Powell-Eyring model predicts the highest values of the characteristic relaxation times among models used for heat transfer experimental works for a given polymer solution. As degradation of a polymer solution continues, the zero-shear-rate viscosity decreases more seriously than the infinite-shear-rate viscosity. Characteristic relaxation times of polymer solutions decreases as degradation continues.

Change on Lens Accommodation and Pupil Light Reflex in VDT works (VDT작업이 안 조절반응과 동공 대광반사에 미치는 영향)

  • Kim, Eun-A;Kim, Yang-Ho;Jin, Young-Woo;Chai, Chang-Ho;Choi, Yong-Hyu;Moon, Young-Hahan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.599-608
    • /
    • 1997
  • We studied on change of lens accommodation and pupil light reflex caused by VDT work in six women and compared them with those of other office works. The results were as follows. 1. In VDT work the accommodation contraction velocity decreased during the first 2-hr VDT task, then recovered markedly by the end of the one-hour lunch break, and decreased again by the end of the 2nd 2-hr VDT task. Changes of relaxation velocity showed similar pattern although it was less typical than that of contraction velocity 2. There was no marked change in accommodation contraction velocity and amplitude of accommodation in general office work and near-distance office work, and in the near-distance office work accommodation relaxation velocity decreased according to work load without recovery after lunch break. 3. Initial pupil diameter, initial pupil area of light reflex decreased significantly during VDT task only in VDT work and didn't recover after lunch break. These results suggest possibility that changes of accommodation contraction velocity, accommodation relaxation velocity, near point distance, and pupil diameter and area are useful in evaluating characteristics of VDT work. For this, more research adjusted individual differences, circadian rhythm, emotional stress needs.

  • PDF

Implementing a Bio-IT Device for Continuous Shooting of the DNA Analysis Process (DNA 분석 과정을 연속 촬영하는 바이오 IT 장치 구현)

  • Lim, H.J.;Ku, J.H.;Kim, S.I.;Kim, J.D.;Lee, W.Y.
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06c
    • /
    • pp.202-205
    • /
    • 2011
  • 본 논문은 DNA 특성분석 기능을 수행하는 전기영동 장치와 분석결과 해석 기능을 수행하는 젤닥 장치를 통합한 장치를 제안하였다. 이들 두 기능을 독립적으로 수행하는 기존의 시스템은 바이오 전문가의 중간 개입 작업이 필요하며 경험치에 의존하는 검사의 부적황성, 높은 오염가능성, 긴 검사시간 등의 한계점을 가지고 있다. 기존 장비에서 독립적으로 수행하던 두 기능을 동시에 수행하도록 하여, 현 시스템의 한계점들을 개선 할 수 있는 장치를 제안하고 구현하였다. 한편 기존에는 완료된 최종 결과 영상 한 장만을 획득 할 수 있었던 것에 반해 특성분석 중에 결과 영상을 실시간으로 모니터링할 수 있어서 DNA 특성 분석의 성공 여부를 조기에 판단할 수 있었다.

Evaluation Methode for LPMS Sensor of Nuclear Power Plant (원자력발전소 금속파편감시계통 센서 건전성 평가)

  • Jo, Sung-Han;Jung, Chang-Gyu;Kim, Hyoung-Gwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1816-1817
    • /
    • 2011
  • 원자력발전소의 금속파편감시계통(LPMS : Loose Parts Monitoring System)은 원자로냉각재계통 내부에 존재할 수 있는 금속 이물질과 구조물 이완부에 의한 충격신호를 조기에 검출하여 원자로 구조물 및 핵연료 손상, 제어봉 구동장애 등을 미연에 방지하여 발전소 안전운전을 담당하는 중요 감시설비이다. LPMS는 금속 이물질이나 구조물 이완부에 의한 충격신호를 검출하기 위해 충격파에 민감한 가속도계를 원자로냉각재계통 중 금속파편이 자연적으로 모일 수 있는 각 구역의 표면에 최소 2개 이상 설치되어 있다. 원전은 규제요건에 따라 설비의 건전성 확인을 위해 24시간, 7일, 31일, 91일 마다 각 1회의 설비 건전성 시험을 수행하며, 계획예방정비기간 중에는 가속도계 주변에서 강구나 스프링 타격기를 이용한 충격시험을 통해 설비 전체의 건전성을 확인하고 있다. 설비 건전성 확인을 위해 경상운전 중에 수행하는 설비 건전성 시험에는 설비 특성상 가속도계 및 전치증폭기의 건전성을 확인할 수 없다. 따라서 본 논문에서는 경상운전 중 가속도계와 전치증폭기의 건전성을 확인할 수 있는 기법을 제시하고자 한다.

  • PDF