• Title/Summary/Keyword: 튜빙

Search Result 14, Processing Time 0.019 seconds

Tapered production tubing design considering flow stability and production rate (유동안정성과 생산량을 고려한 2단 생산튜빙 디자인)

  • Kim, Sung-Il;Jo, Gyung-Nam;Choe, Jonggeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.548-556
    • /
    • 2013
  • A tapered production tubing with two different inner diameters has been suggested to increase production rates. In this research, various tapered tubing combinations are taken into account and possible tubing combinations are proposed to satisfy each objective. In previous studies, production enhancement was the main goal. However, this research also considers flow stability by analyzing tubing pressure traverse, liquid holdup, and operating conditions. For a reservoir assumed in this research, a tapered tubing of, 4.5 inch inner diameter(ID) and 2000 ft in length in the lower part and 5.5 inch ID and 8000 ft in the upper part, shows the highest net present value. Compared to a mono tubing, tapered tubings enable various tubing designs because they have smaller differences in frictional pressure loss. It is important to maintain low liquid holdup to prevent liquid loading. Smaller ID of tapered tubing in the lower part enables to achieve the object. In conclusion, it is identified that various tubing designs are achievable from the analyses of overall production operations depending on purposes specified.

Comparative Study on the Adsorptive Loss of Reduced Sulfur Compounds (RSC) by the Selection of Tubing Materials (튜빙의 종류에 따른 환원황화합물들의 흡착손실 비교 연구)

  • Kim Ki-Hyun;Ahn Ji-Won;Choi Ye-Jin
    • Journal of the Korean earth science society
    • /
    • v.26 no.7
    • /
    • pp.668-673
    • /
    • 2005
  • To collect or transfer samples of gaseous pollutants, various types of tubing are used. Hence, to analyze the uncertainties associated with the use of tubings, a series of comparative test were designed and conducted using the RSC standards with different concentration ranges. For the purpose of this study, we prepared tubings made of six different types of material which include: [1] silco-steel (S1), [2] stainless steel (S2), [3] silicone (S3), [4] PTFE Teflon (T1), [5] tygon (T2), and [6] brass (B). The patterns of RSC loss on to tubing walls, when compared on the basis of the least reactive material S1, exhibited that the extent of RSC loss varied dynamically. It was found that Teflon is highly stable. However, other materials tend to exhibit contrasting patterns of loss. S2 and B show significant loss of light RSC $(H_2S\;and\;CH_3SH)$, while S3 and T2 experience notable loss of heavy RSC (DMS and DMDS).

Failure Mechanism and Long-Term Hydrostatic Behavior of Linear Low Density Polyethylene Tubing (선형저밀도 폴리에틸렌 튜빙의 파손 메커니즘과 장기 정수압 거동)

  • Weon, Jong-Il;Chung, Yu-Kyoung;Shin, Sei-Moon;Choi, Kil-Yeong
    • Polymer(Korea)
    • /
    • v.32 no.5
    • /
    • pp.440-445
    • /
    • 2008
  • The failure mechanism and failure morphology of linear low density polyethylene (LLDPE) tubing under hydrostatic pressure were investigated. Microscopic observations using video microscope and scanning electron microscope indicate that the failure mode is a brittle fracture including cracks propagated from inner wall to outer wall. In addition, oxidation induction time and Fourier transform infrared spectroscopy results show the presence of exothermic peak and the increase in carbonyl index on the surface of fractured LLDPE tubing, due to thermal-degradation. An accelerated life test methodology and testing system for LLDPE tubing are developed using the relationship between stresses and life characteristics by means of thermal acceleration. Statistical approaches using the Arrhenius model and Weibull distribution are implemented to estimate the long-term life time of LLDPE tubing under hydrostatic pressure. Consequently, the long-term life time of LLDPE tubing at the operating temperature of $25^{\circ}C$ could be predicted and also be analyzed.

Effects of Dynamic Tubing Gait Training on Postural Alignment, Gait, and Quality of Life in Chronic Patients with Parkinson's Disease : Case Study (동적탄력튜빙 보행훈련 프로그램이 만성 파킨슨병 환자의 자세정렬과 보행능력과 삶의 질에 미치는 영향 : 사례연구)

  • Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.363-377
    • /
    • 2021
  • The present study investigated the effects of dynamic tubing gait training(I and II) on the postural alignment, gait, and quality of life in chronic patients with Parkinson's disease. This study is based on the case study that recruited a total of 3 patients with chronic Parkinson's disease (Hoehn and Yahr Stage of 1 to 3 each one person). Dynamic tubing gait training (I and II) applied to chronic patients with Parkinson's disease for 25 sessions, 30 minutes a day, 5 days a week, over 5 weeks period. To investigate the effects of this study, evaluating using the postural alignment test, muscle activity tests, gait analysis, and quality of life scale for patient with Parkinson's disease. After the intervention of Dynamic tubing gait training (I and II), Trunk flexion was decreased. Also, during walking from initial contact (IC) to mid stance (Mst), muscle activity of Quadriceps, Hamstring, and Tibialis Anterior (TA) was increased and muscle activity of Gastrocnemius was decreased. The muscle activation of Erector Spinae (ES T12, L3) was increased in the H&Y I and III stages and decreased in the H&Y II stage. Length of gait line, single support line, ant/post position and lateral symmetry of center of pressure (COP) parameters improved. The spatio-temporal gait parameters including of step length, stride length, and velocity was increased, and cadence decreased. Further the quality of life of patients with Parkinson's disease was improved. Based on these findings, Dynamic tubing gait training (I and II) could be applied as a new approach to improve posture, gait, quality of life in chronic patients with Parkinson's disease for more than 5 years, whose drug resistance is halved.

Effect of Dynamic Tubing Gait Training for Life-Care on Balance of Stroke Patients (라이프케어 증진을 위한 동적탄력튜빙 보행훈련이 뇌졸중 환자의 균형에 미치는 영향)

  • Lee, Seon-Yeong;Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.1
    • /
    • pp.171-180
    • /
    • 2021
  • The present study investigated the effects of dynamic tubing gait (DTG II) program on the balancing ability for the promotion of life care of patients with chronic stroke. In the study, 25 sessions of DTG II program (30 minutes per session, 5 sessions per week, for a total of 5 weeks) were applied to 10 patients with chronic stroke. To determine the effects of DTG II program for improving balance, surface electromyography(external oblique, erector spinae, iliopsoas, gluteus maximus), symmetry index test on three pelvic axes, and dynamic gait index test were performed before and after the intervention. The results showed statistically significant differences between preand post-intervention measurements of the gluteus maximus muscle at early and mid-stance phases(p<.05). The pelvic symmetry index differed significantly between pre- and post-intervention measurements of diagonal and rotational movement(p<.05). Comparison of dynamic gait index also showed statistically significant differences between pre- and post-intervention measurements(p<.05). Based on these findings, it was determined that the DTG II program was able to improve the balancing ability of patients with chronic stroke by activating their trunk muscles and improving the symmetry of diagonal pelvic movement and rotation. Therefore, DTG II program is recommended as an interventional method to improve life-care through improving the balancing ability of patients with chronic stroke.

Structural Reliability Analysis of Subsea Tree Tubing Hanger (Sub-sea 트리 튜빙 행어(tubing hanger)의 구조 신뢰성 해석)

  • Kim, Hyunjin;Yang, Youngsoon;Kim, Sunghee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.3
    • /
    • pp.212-219
    • /
    • 2014
  • As subsea production has been revived up, the demand of subsea equipment has also been increased. Among the equipment, subsea tree plays a major role in safety. The tubing hanger is one of the most important components in subsea tree. In this study structural reliability analysis on dual bore tubing hanger of subsea tree is performed. The target reliability which is introduced in ISO regulation is used for judging whether tubing hanger is safe or not. The considered loads are working pressure, working temperature and suspended tubing weight. Thermal-stress analysis on tubing hanger is performed and kriging model is created based on the results of FEM analysis. According to von Mises criterion, limit state equation can be estimated. Reliability analysis is performed by using level 2 method and the result is verified by that of Monte Carlo Simulation. For finding most probable failure point, enhanced HL-RF method is adopted. Because the reliability of model doesn't reach target reliability, an improvement measure should be considered. Thus, it is suggested to change the material of tubing hanger main body to AISI 4140.

A Study on Minimizing the Residual $^{18}F$-FDG in the Tubing Using Nitrogen Gas (FDG 합성 후 질소가스를 이용한 튜빙의 잔류 $^{18}F$-FDG 최소화를 위한 방법의 유용성)

  • Kim, Dong-Il;Park, Hoon;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.8-12
    • /
    • 2010
  • Purpose: In $^{18}F$-FDG automated synthesizer, deliver is done in automated mode after synthesis until the dispenser. After the delivery, the yield is calculated from the radioactivity which was read by the dose calibrator located in the dispenser. However, when the distance between the automated synthesizer and the dispenser is far, there are $^{18}F$-FDG residues, which results in loss of the amount of $^{18}F$-FDG. This study investigated the usefulness of a method that minimizes $^{18}F$-FDG residues. Materials and Methods: The structure of the tubing between the (TRACERlab Mx FDG; GE.) and the dispenser is that the distance is 8 m and the internal diameter is 1/16 inch. The synthesis process of The module goes through the synthesis process of trap, synthesis, delivery in the automated module. The time taken for synthesis is about 25 to 26 minutes, after which rinsing is done. However, after rinsing, as the distance of the tubing increased, there were 10~13% of $^{18}F$-FDG residues. Therefore, a method of using push syringe and $N_2$ gas in manual mode to minimize $^{18}F$-FDG residues is analyzed. Results: In manual mode, there were $^{18}F$-FDG residues of 4~5% for the push syringe, and there were $^{18}F$-FDG residues of less than 1% for the $N_2$ gas, which showed that the method using $N_2$ gas had superior usefulness. Also, there were no $^{18}F$-FDG residues in the cleaning the next day. Conclusion: The distance between the synthesizer and the dispenser needs to be reduced as much as possible, to reduce the rate of loss of $^{18}F$-FDG resulting from the distance of the tubing. However, in case the distance between the synthesizer and the dispenser has to be increased due to the system structure, using push syringe and $N_2$ gas simultaneously is a useful method for minimizing $^{18}F$-FDG residues.

  • PDF

A Study for Tubing Pipe Flaw Sizing by Using Guided Ultrasonic Wave (유도초음파기법을 이용한 튜빙 결함측정에 관한 연구)

  • Joo, Kyung Mun;Cheon, Keun Young;Lee, Jeong Seok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • There is extensive tubing pipe in the nuclear power plant under high temperature and pressure. Erosion and corrosion defects are expected on this tubing pipe due to environmental and mechanical factors. In this study, Guided Ultrasonic Wave technique was applied to detect defects. The technique explores the advantages of the Guided Ultrasonic Wave method that inspects along the wall of the pipe and can travel long distances, providing rapid collection of data. This paper presents a case study of the Guided Ultrasonic Wave testing of 3/8" tubing pipe. This study offers to understand detected signals through correlation between amplitude and depth of defects.

  • PDF

Flow Analysis of Resin in an Extrusion Die for the Production of Medical Catheter Tubes (의료용 카테타 튜빙의 압출을 위한 다이내의 수지 흐름해석)

  • Lee, M.A.;Lyu, M.-Y.;Shin, D.J.;Kim, T.K.
    • Transactions of Materials Processing
    • /
    • v.24 no.2
    • /
    • pp.89-94
    • /
    • 2015
  • Medical catheter tubes are disposable devices that are inserted into the body cavities such as the pleura, trachea, esophagus, stomach, urinary bladder, ureter, or blood vessels for surgical procedures. Each hole of the inner tube is called a lumen, which is used as a passage for drug injections, waste discharge, polypus removal, blood transport, or injection of a camera or sensor. The catheter tube is manufactured by extrusion. The flow in the inner extrusion die affects the thickness and diameter of the tube. In the current study computer simulation of flow in an extrusion die for catheter tubing was performed. Velocity, pressure, shear rate, and shear stress were investigated and the die design was examined.

Establishment of a Dental Unit Biofilm Model Using Well-Plate (Well-Plate를 사용한 치과용 유니트 수관 바이오필름 모델 확립)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.17 no.4
    • /
    • pp.283-289
    • /
    • 2017
  • The water discharged from dental unit waterlines (DUWLs) is heavily contaminated with bacteria. The development of efficient disinfectants is required to maintain good quality DUWL water. The purpose of this study was to establish a DUWL biofilm model using well-plates to confirm the effectiveness of disinfectants in the laboratory. Bacteria were obtained from the water discharged from DUWLs and incubated in R2A liquid medium for 10 days. The bacterial solution cultured for 10 days was made into stock and these stocks were incubated in R2A broth and batch mode for 5 days. Batch-cultured bacterial culture solution and polyurethane tubing sections were incubated in 12-well plates for 4 days. Biofilm accumulation was confirmed through plating on R2A solid medium. In addition, the thickness of the biofilm and the shape and distribution of the constituent bacteria were confirmed using confocal laser microscopy and scanning electron microscopy. The average accumulation of the cultured biofilm over 4 days amounted to $1.15{\times}10^7CFU/cm^2$. The biofilm was widely distributed on the inner surface of the polyurethane tubing and consisted of cocci, short-length rods and medium-length rods. The biofilm thickness ranged from $2{\mu}m$ to $7{\mu}m$. The DUWL biofilm model produced in this study can be used to develop disinfectants and study DUWL biofilm-forming bacteria.