• Title/Summary/Keyword: 튜브군

Search Result 54, Processing Time 0.038 seconds

Fluid-Elastic Instability of Tube Bundles in Two-Phase Cross-Flow (2상 횡유동을 받는 튜브군의 유체탄성 불안정성)

  • 김범식;장효환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1948-1966
    • /
    • 1991
  • Two-phase cross-flow exists in many shell-tube heat exchangers such as condensers, reboilers and nuclear steam generators. To avoid problems due to excessive vibration, information on vibration excitation in two-phase cross-flow is required. Fluid-elastic instability is discussed in this paper. Four tube bundle configurations were subjected to increasing flow up to the onset of fluid-elastic instability. The tests were done on bundles with one flexible tube surrounded by rigid tubes. The fluid-elastic instability behavior is different for intermittent flows than for bubbly flows. For bubbly flows, the observed instabilities satisfy the relationship V/fd=K(2.pi..zeta. m/rho. $d^{21}$)$^{0.51}$ in which the minimum instability factor K was found to be 2.3 for bundles of p/d=1.22. The lowest critical velocities for fluid-elastic instability were experienced with parallel-triangular tube bundles. For intermittent flow, the observed instabilities did not follow the forgoing relation-ship. Significantly lower flow velocities were required for instability..

Acoustic resonance by length of acoustic baffle at Finned Tube bank (핀-튜브군에서 배플 길이에 따른 음향공진)

  • 방경보;류제욱
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF

Tubing Wear and Spallation Induced by Roller pumps in Cardiopulmonary Bypass (심폐바이패스 롤러펌프에 의한 튜브 마모 및 폐쇄)

  • 김원곤;성기익;윤철용;신윤철
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.609-616
    • /
    • 1999
  • 심폐바이패스시 발생할 수 있는 튜브 마모 및 파쇄는 롤러펌프의 반복되는 압박에 의해 롤러펌프에 장착된 튜브 내벽에 균열이 생기고 이로 인해 미세한 비생물적 조각들이 혈액중으로 떨어져 나가는 현상을 말하는데, 임상적으로 치명적인 색전증을 초래할 수 있다. 그러나 아직 롤러펌프 튜브로 사용되는 PVC 및 실리콘 튜브 중 어느 쪽이 마모 및 파쇄 관점에서 더 우수한지는 체계적으로 밝혀지지 않고 있다. 이에 본 연구는 두 종류의 튜브를각각 일정 기간 롤러펌프에 장착하여 작동시킨 뒤 튜브내외면을 육안 및 주사형 전자현미경으로 관찰하였다. 즉 PVC 및 실리콘 튜브 (내경 1/2 인치의)들을 미리 정해진 폐쇄도 조절에 의해 폐쇄 회로 심폐비이패스 롤러펌프 헤드에 장착시키고 4.500ml/min에서 각각 4차례씩 1,2,4,6 시간 작동시켰다. 파쇄에 의한 색전 관찰 실험에서는 회로 중간에 동맥여과기를 설치하고 각각 6,9시간 씩 롤러펌프를 작동시켰다. 실험 후 튜브 및 여과기들을 수거한 후 육안 및 주사형 전자현미경 분석을 시행하였다. 실험후 튜브 및 여과기들을 수거한 후 육안 및 주사형 전자현미경을 분석을 시행하였다. 튜브 외부의 육안 관찰 결과 일반적으로 실라스틱 튜브에서의 외부 마모가 PVC 튜브에 비해 현저하였다. 주사형 전자현미경 관찰에서 PVC 튜브에서의 홈은 좁으면서 경계선이 뚜렷한 특징을 보였고 3시간 이상 롤러와 접촉한 튜브들에게서는 깊은 균열이 간헐적으로 관찰되었다. 반면, 실라스틱에서의 홈은 좁으면서도 경계선이 뚜렷한 특징을 보였고 3시간 이상 롤러와 접촉한 튜브들에게서는 깊은 균열이 간헐적으로 관찰되었다.반면 실라스틱에서의 튜브들에서는 홈이 상대적으로 넓고 경계가 덜 명확했으며, 특징적으로 V 자 모양의 융기부들이 간헐적으로 관찰되었다. 실라스틱 및 PVC 튜브 모두에서 50u 전후의 Craters 가 간헐적으로 관찰되었다. 여과기의 여과망에 대한 주사형 전자현미경 분석 결과 실라스틱과 PVC 튜브 실험군 모두에서 색전입자로 의심되는조각들이 발견되었으나 두군간 정량적 비교는 어려웠다. 결론적으로 롤러펌프에 의한 튜브 마모 및 파쇄현상은 실리콘 및 PVC 튜브의 재질에 따라 그 양상에는 차이가 있으나 임상적인 측면에서는 어느 쪽도 상대적인 우수성이 입증되지 못하였다.

  • PDF

Quality Changes in Minced Ginger Prepared with Frozen Ginger during Storage (냉동생강으로 제조한 다대기의 저장 중 품질변화)

  • Kim, Dong-Ho;Lee, Young-Chun
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.943-951
    • /
    • 2004
  • As storing ginger roots under optimum conditions takes high cost, ginger roots are commonly stored in underground tunnels where the maintenance of optimum temperature and humidity is difficult. One of the methods fur long term storage of ginger roots is freezing. The objective of this research was to evaluate effect of storage temperatures and packaging methods on the quality of minced ginger prepared with frozen stored ginger. The minced ginger prepared with frozen stored ginger at $-20^{\circ}C$ was packed in bags, glass bottles and tubes, and then stored at 5 and $-20^{\circ}C$ for quality evaluation at 4 and 15 week-intervals. The changes of surface color, total free sugars, free amino acids and volatile compounds were less in the combined treatment samples than in control during storage, regardless of the storage temperature. The tube packing was the best for maintaining quality of minced ginger during storage among tested packaging methods. Sensory results showed that the minced ginger with the combined treatment and packed in tubes could be stored at 5 and $-20^{\circ}C$ for 12 and 45 weeks, respectively, without a significant drop in palatability.

Clinical Observation of Middle Ear Effusion Especially in Relation to Children needed Adenotonsillectomy (삼출성중이염의 임상적 고찰 -특히 구개인두편도절제술을 요하는 소아와의 관계-)

  • 김종애;전병권;배정수;김백순
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.15.1-15
    • /
    • 1982
  • Clinical findings for 95 patients (159 ears) of MEE (middle ear effusion) treated at Wallace Memorial Baptist Hospital (Busan) from July 1979 to August 1981 were observed. A group who was treated with myringotomy and ventilation tube isertion was compared with another group of children treated with adenotonsillectomy at the same time. The following are the results: 1) The sex distribution showed 48 male and 47 female, and the age distribution was most common in the ages from six to ten (34 cases, 35%). 2) MEE of children treated with adenotonsillectomy in the same duration was 18 cases (14%), and it was 19% of all MEE patients. 3) Bilateral effusion (67%) was as twice as unilateral cases (33%). In children, bilateral effusion (42 cases, 88%) was predominant, and MEE in adenotonsillectomized children was bilateral in all cases. 4) The nature of middle ear fluid was 49% serous exudate, 33% mucoid exudate, 5% purulent and 3% bloody fluid. Serous exudate was 59% in adult group, but serous (41%) and mucoid exudate (43%) was similar incidence in children. 5) In the preoperative tympanogram, there were 6% with type A, 91% with type B, and 3% with type C. The incidence of abnormal tympanogram (type B or C) was same in MEE patients of adenotonsillectomized children (95%) and the other children group (95%), and it was 93% in adult group. 6) Treatment by myringotomy and ventilation tube insertion resulted in postoperative improvement in air conduction hearing acuity especially in adenotonsillectomized children.

  • PDF

Fluidelastic Instability Analysis of the U-Tube Bundle of a Recirculating Type Steam Generator (재순환식 증기발생기 U-튜브군에 대한 유체탄성 불안정 해석)

  • 조종철;이상균;김웅식;신원기;은영수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.200-214
    • /
    • 1993
  • This paper presents the results of fluidelastic instability analysis performed for the U-tube bundle of a Westinghouse model 51 steam generator, one of the recirculating types designed at an early stage, in which the principal region of external cross-flow is associated with the U-bend portion of tube. The prerequisites for this analysis are detailed informations of the secondary side flow conditions in the steam generator and the free vibration behaviours of the U-tubes. In this study, the three-dimensional two-phase flow field in the steam generator has been calculated employing the ATHOS3 steam generator two-phase flow code and the ANSYS engineering analysis code has been used to calculate the free vibration responses of specific U tubes under consideration. The assessment of the potential instability for the suspect U-tubes, which is the final analysis process of the present work, has been accomplished by combining the secondary side velocity and density distributions obtained from the ATHOS3 prediction with the relative modal displacement and natural frequency data calculated using the ANSYS code. The damping of tubes in two-phase flow has been deduced from the existing experimental data by taking into account the secondary side void fraction effect. In operation of the steam generator, the tube support conditions at the tube-to-tube support plate intersections due to either tube denting degradation or deposition of tube support plate corrosion products or ingression of dregs. Thus, various hypothetical cases regarding the tube support conditions at the tube-to-tube support plate intersections have been considered to investigate the clamped support effects on the forced vibration response of the tube. Also, the effect of anti-vibration bars support in the curved portion of tube has been examined.

The Short Term and Intermediate Term Results of using a T-tube in Patients with Tracheal Stenosis (기관 협착 환자에서의 T-튜브의 중단기 결과)

  • Sa, Young Jo;Moon, Seok-Whan;Kim, Young-Du;Jin, Ung;Park, Jae-Kil;Kim, Jae Jun;Kim, Chi-Kyung;Jo, Keon Hyon;Park, Chan Beom;Yim, Hyeon Woo
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • Background: The treatment of tracheal stenosis includes less invasive bronchoscopic intervention and more invasive segmental resection & anastomosis. Depending on the patient's clinical features, sometimes all these methods are inappropriate. Silicone T-tube stenting has recently been used as an alternative, safe management of tracheal stenosis. We studied the short term and Intermediate term results of using T-tubes in patients with tracheal stenosis, and this tracheal stenosis was caused by various underlying diseases. Material and Method: We retrospectively reviewed 57 patients with tracheal stenosis and who were treated with T-tubes between Jan 1997 and Apr 2007. Based on the patient's medical records and the imaging studies, we evaluated the clinical findings and status of T-tube removal. Result: There was no T-tube related morbidity or mortality in this series. On follow-up, one patient underwent sleeve resection and end-to-end anastomosis. The T-tube could be successfully removed from 13 patients (13/57, 22.8%) without additional interventions. For another four patients, a T-tube was again inserted after removal of the first T-tube due to tracheomalacia or recurrent stenosis. Four patients died of underlying disease and cancer. The patients' gender and previous tracheostomy significantly affected T-tube removal. By contrast, multiple logistic regression analysis identified gender as a predictor of successfully removing a T-tube. Gender (p=0.033) and previous tracheostomy (p=0.036) were the two factors for success or failure of T-tube removal. Conclusion: A T-tube provided reliable patency of a stenotic airway that was caused by any etiology. We have proven that using a T-tube is safe and effective therapy for patients with tracheal stenosis for the short term or the intermediate term.

Simulation of Remote Field Scanner for Defect Evaluation of Water Wall Tube Within the Fluidized Bed Boiler (유동층보일러 수냉벽튜브 결함평가를 위한 원격자장 스캐너 시뮬레이션에 관한 연구)

  • Gil, Doo-Song;Jung, Gye-Jo;Seo, Jung-Seok;Kim, Hak-Joon;Kwon, Chan-Wool
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.145-150
    • /
    • 2020
  • Water wall tube is one of the major factors consisting of a fluidized bed boiler and it plays very important role for the generation of electricity within the boiler. But these water wall tubes within the fluidized bed boiler are subject to the ware and corrosion caused by the high temperature gas and the flowing medium. If water leak is occurred, the secondary damage by the water leak will occur. As a result of that, the power generation efficiency decreases noticeably. Therefore, the maintenance of the water wall tube is very important. In this study, we designed a exciter sensor based on simulation and composed a remote field eddy current system for the defect evaluation of the outer water wall tube. Starting from the shape design of exciter, we conducted simulations for various design factors such as the water wall tube size, material, frequency, lift-off and so on. Based on the results, we designed the optimum exciter sensor for the water wall tube test within the fluidized bed boiler.

COVID-19 Korean Fake News Detection using Named Entity and User Reproliferation Information (개체명 및 사용자 재확산 정보를 이용한 한국어 COVID-19 가짜 뉴스 검출)

  • Park, Chaewon;Kang, Jiwon;Lee, Daeun;Lee, Munyoung;Han, Jinyoung
    • Annual Conference on Human and Language Technology
    • /
    • 2021.10a
    • /
    • pp.85-90
    • /
    • 2021
  • 코로나바이러스감염증-19로 인한 팬데믹 상황이 지속되면서 감염증 정보의 불확실성으로 인해 코로나 관련 루머가 온라인상에서 빠르게 전파되고 있다. 이러한 코로나 관련 가짜 뉴스를 사전에 탐지하기 위해, 본 연구에서는 한국어 코로나 가짜 뉴스 데이터셋을 구축하고, 개체명과 사용자 재확산 정보를 이용한 한국어 가짜 뉴스 탐지 모델을 제안한다. 가짜 뉴스 팩트체킹 언론인 서울대팩트체크센터에서 코로나 관련 루머 및 가짜 뉴스에 대한 검증 기사를 수집한 후, 기사로부터 개체명 추출 모델을 통해 주제 키워드를 추출하고, 이를 이용해 유튜브 상의 사용자 재확산 정보를 수집하여 데이터셋을 구성하였다. BERT 기반의 제안 모델을 다양한 비교군과 비교하였고, 특성 조합에 따른 실험을 통해 각 특성 정보(기사 텍스트, 개체명 데이터, 유튜브 데이터)가 가짜 뉴스 탐지 성능에 미치는 영향을 알아보았다.

  • PDF