• Title/Summary/Keyword: 투수계수저하

Search Result 62, Processing Time 0.035 seconds

Application of Non-Alkaline Silica Sol Grouting Method Considering the Eco-Friendliness (친환경 비알칼리성 실리카졸 차수공법의 적용)

  • Jang, Yonggu;Kim, Sugyum;Kang, Injoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.9
    • /
    • pp.37-45
    • /
    • 2016
  • This study analyzes the environmental and durability problems of traditional (LW) grouting method. And the proposed method was compared to the others effects by analyzing the in-situ applicability and effect of performance of the method using the silica sol. This study analyzed the eco-friendly, effects of high strength silica sol through laboratory tests. The effects of the construction process were identified through the field tests. The compressive strength was increased by 1.3 times compared to the LW method and the shrinkage is 3~8 times less than that of LW method with water glass. No toxicity, which could affect soil contamination. In particular, it was confirmed that the Toxicity fish also survived with little pH change in the concentration tank. Also it confirmed the construction effects through field test. Field tests are a standard penetration test, permeability test, LLT, BST. Permeability was reduced to $1{\times}10^{-5{\sim}-6}cm/sec$.

Characteristics of Ternary Blended Cement Concrete Using Fly Ash and Silica Fume for Post-Tensioned Concrete Pavement Application (포스트텐션 콘크리트 포장 적용을 위한 실리카흄과 플라이 애시를 사용한 삼성분계 콘크리트의 특성)

  • Choi, Pan-Gil;Shim, Do-Sick;Lee, Bong-Hak
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.41-47
    • /
    • 2009
  • Post-tensioned concrete pavement(PTCP) was developed to built long-span concrete pavement(120 m span) and to maintain long-term service life(over 40 years) of concrete pavement. In the present study, research for high-durable concrete was conducted to utilize the advantage of PTCP construction method efficiently. First of all, 20% of fly ash(by binder weight) was replaced to control alkali silica reaction. Second, silica fume was applied to improve the water-permeability and early-age strength. Results of tests for mechanical properties, water-permeability resistance, and surface-scaling resistance of ternary blended cement concrete showed that the early-age strength was improved significantly with addition of silica fume. The water-permeability resistance was improved from "Low" to "Very Low"(ASTM C 1202). However, surface-scaling resistance was decreased with an increase of silica fume, therefore, content of silica fume should be kept in less than 5%(by binder weight) to assure field application considering durability. The results of air-void analysis showed that durability factors were improved since spacing factors were estimated as 250$\pm$15 micron in adjusted mixtures.

Development of Surface Pavement Materials for Environment-Friendly Farm Road (환경친화형 경작로를 위한 표층포장재료의 개발)

  • Sung, Chan-Yong;Kim, Young-Ik
    • Korean Journal of Agricultural Science
    • /
    • v.31 no.2
    • /
    • pp.105-114
    • /
    • 2004
  • This study was performed to examine the physical and mechanical properties of eco-concrete using soil, natural coarse aggregate, soil compound and polypropylen fiber. The mass loss ratio was decreased with increasing the content of coarse aggregate and soil compound. The compressive strength, flexural strength, ultrasonic pulse velocity and dynamic modulus of elasticity were increased with increasing the content of coarse aggregate, soil compound and polypropylene fiber. The compressive and flexural strengths were showed in 8.07 MPa and 2.641 MPa at the curing age 28 days, respectively. The coefficient of permeability was decreased with increasing the content of coarse aggregate and soil compound, but it was increased with increasing the content of polypropylene fiber. The lowest coefficent of permeability was showed in $5.066{\times}10^{-9}cm/s$.

  • PDF

Comparison & Analysis for Fine Sand Migration in Filter (조립 Filter내에서 세상의 이동현상에 대한 비교분석)

  • Kim, Hyun-Ki;Kwon, Moo-Nam
    • Current Research on Agriculture and Life Sciences
    • /
    • v.16
    • /
    • pp.15-23
    • /
    • 1998
  • This experiment did comparison and analysis that protected soil particle migration have affect on function of the filter and therefore fall function of the filter. Results obtained are as follows: 1.High water head makes to be much movement of fine sand and out flow of particle to the outside. The filter have large opening size that reached stability an early stage, but much fine sand is washed away. If the velocity turns fast and becomes small, blocking phenomenon is remarkable nearby the filter-sand interface. 2. The movement of fine sand that effect on function of filter depend on opening size and change of water head. Under the same condition, USCE filter and USSPL filter is reached earlier than other filter that is stability of stage, because it's opening size is large. 3. Residual quantity of fine sand migration was largly come out in order of USSPL, USCE, USBR, Newton & Hurley, Bertram filter. 4. The time required to stability of flow was taken less in order of Bertram, Newton & Hurley, USBR, USSPL, USCE filter and coefficient of permeability was highly come out in order of USBR, Bertram, Newton & Hurley, USSPL, USCE filter. 5. It proved that USCE and USSPL is suitable for the filter criteria.

  • PDF

A Study on the Evaluation of Smear Zone by In-situ Tests (현장시험에 의한 Smear Zone의 평가)

  • 이장덕;구자갑
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.207-216
    • /
    • 2003
  • To evaluate the smear zone caused by the drain installation, 10 piezometers were installed in the typical soft ground in the western coastal area of Korea. The dynamic pore water pressure developed during the drain installation was monitored using piezometers installed at a distance of 10cm, 20cm, 30cm, 40cm and 50cm from the location of the drain. The decay of pore pressure with time after pushing piezometers to depths of 5 meters and 7 meters during the drain installation was monitored to assess flow and consolidation characteristics of the soil after disturbance of the soil due to the drain installation. The drain installation results in shear strain and displacement of the soil and it decreases the permeability of the soil. Hence, the comparison between dissipation of the pore water pressure process in 10 pieszometers before as well as after installation of the drain indicated the diameter of disturbance zone and smear zone, which is related to the cross-sectional dimension of the mandrel. In addition, Cone-pressuremeter(CPM) tests were performed to obtain rigidity index of the soil for an interpretation of the dissipation processes. It has been evaluated by in-situ tests that the smear zone is from 3.0 to 3.6 times of the cross-sectional dimension of the mandrel. The hydraulic conductivity expressed in terms of the coefficient of consolidation after the drain installation was calculated from 3 to 8 times decrease evaluated by Teh & Houlsby equation and CPM test results.

Long-Term Performance Evaluation of Concrete Utilizing Oyster Shell in Lieu of Fine Aggregate (굴패각을 잔골재로 대체 사용한 콘크리트의 장기성능 평가)

  • Yang, Eun-Ik;Yi, Seong-Tae;Kim, Hak-Mo;Shim, Jae-Seol
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.280-287
    • /
    • 2003
  • To evaluate the practical application of oyster shells(OS) as construction materials, an experimental study was performed. More specifically, the long-term mechanical properties and durability of concrete blended with oyster shells were investigated. Test results indicate that long-term strength of concrete blended with 10% oyster shells is almost identical to that of normal concrete. However, the long-term strength of concrete blended with 20% oyster shells is appreciably lower than that of normal concrete. Thereby, concrete with higher oyster shell blend has the possibility of negatively influencing the concrete long-term strength. Elastic modulus of concrete blended with crushed oyster shells decreases as the blending mixture rate increases. Namely, the modulus is reduced to approximately 10∼15% when oyster shells are blended up to 20% as the fine aggregate. The drying shrinkage strain increases with an increasing crushed oyster shells substitution rate. In addition, the existing model code of drying shrinkage and creep do not coincide with the test results of this study. An adequate prediction equation needs to be developed. The utilization of oyster shells as the fine aggregate in concrete has an insignificant effect on fleering and thawing resistance, carbonation and chemical attack of concrete. However, water permeability is considerably improved.

Durability of Latex-Modified Concrete with Rapid-Setting Cement (초속경시멘트를 이용한 라텍스개질 콘크리트의 내구특성)

  • Yun, Kyong-Ku;Jung, Won-Kyong;Choi, Sang-Reung;Kim, Dong-Ho;Lee, Bong-Hak
    • International Journal of Highway Engineering
    • /
    • v.4 no.2 s.12
    • /
    • pp.1-8
    • /
    • 2002
  • Latex modified concrete(LMC) became to be applied as a new material for newly constructed bridge deck overlays in Korea due to its excellent bond strength, flexural strength and impermeability against water and chloride. However, it could not be adopted at repair job site because of its long curing time required. Thus, a research on latex modified concrete with rapid-setting cement(RSLMC) is necessary if it could develope the sufficient strength for early opening to traffic. This study focused on the durability of latex modified concrete with rapid-setting cement mainly on water permeable resistance and freeze-thaw resistance. The main experimental variables were latex contents(0, 5, 10, 15 and 20%) and antifoamer contents (0, 1.6, 3.2, 4.8 and 6.4%). Test results show that the permeability of RSLMC is very low indicating below 100 coulombs at 15% of latex contents at all antifoamer contents. The freeze-thaw resistance of RSLMC maintains above 90% of relative dynamic modulus at 3.2% of antifoamer content until 300 freezing-thawing cycles.

  • PDF

Establishment of the Detention Model for the Prevention of Unban Innundation (도시침수방지를 위한 저류지 모형 확립)

  • Park, Jae-Hong;Han, Kun-Yeun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1656-1660
    • /
    • 2006
  • 도시 주변의 급격한 택지개발, 도시 인구의 집중, 대규모 계획단지의 개발은 유역의 유출특성에 큰 영향을 주게 되고, 도시화가 진행됨에 따라 불투수 표면이 증가되고 침투율이 감소됨으로써 유출계수의 증가요인이 되고 있다. 이에 따라 유역의 자연 저류지 기능이 저하되고, 우수가 하천으로 유입되는 시간이 단축됨으로써 첨두홍수량 뿐만 아니라 유출총량의 증대를 초래하여 도시 주변의 중소하천 유역에서는 막대한 재산 및 인명 피해가 발생하고 있다. 이러한 도시화로 인해 증가된 유출량을 저감시키는 구조적 방안으로 대부분 강우 유출수를 일시 저류하여 유출량을 조절하는 우수유출 억제시설이 권장되고 있으나, 이들 시설에 대한 수리학적 침수방어능력이 명확히 규명되지 못한 실정이다. 본 연구의 목적은 도시지역 침수방지 대책 수립에 필요한 On/Off-Line 저류지의 평가 및 설계에 기존 부정류 모형들의 모의가능성을 평가 비교하고, 가상하도와 실제하도에 적용하여 모형을 검보정 함으로서 저류지 해석의 실용화 모형을 확립함에 있다. 본 연구 결과는 도시지역에 적용할 수 있는 도시홍수방어시스템의 일환으로 구축함으로써, 도시지역에서 저류지 홍수저감효과를 평가하는 등 침수재해와 연계된 구조적 대책 수립에 필요한 기초자료로 활용하고자 한다. 본 연구에서 연구된 저류지 모형을 이용하여 On-Line 및 Off-Line 저류지에 적용한 결과 두 종류의 저류지 모두 홍수방어를 위해 이용될 수 있었다. On/Off-Line 저류지 모두 첨두유량이 발생할 경우 어느정도의 첨두값의 감쇠를 발생시킬 수 있는 것으로 판단된다. 그러나 저류지 상류단의 수위감소는 저류지로 유출로 인해 저류지 상류 하도부에서 유속의 증가를 발생시켰고 이로 인해 수위는 저류지가 존재하지 않는 경우보다 낮게 나타나고 있다. On-Line 저류지의 경우 Off-Line 의 경우에 비해 수위, 유량이 저류지의 상류단에서 크게 나타났다. On-Line 저류지의 경우 Off-Line 의 경우에 비해 같은 값의 첨두홍수량을 저류하기 위해서 상대적으로 넓은 저류면적이 필요한 것으로 나타난다. 대등한 수위감소값의 홍수저감효과를 발휘하기 위해서 본 연구에서는 On-Line 저류지 면적은 Off-Line 저류지에 비 두배 이상이 필요한 것으로 보여졌다.

  • PDF

Treatment of Acid Mine Drainage Using Immobilized Beads Carrying Sulfate Reducing Bacteria (황산염환원균 고정화 담체를 이용한 산성광산배수 처리)

  • Kim, Gyoung-Man;Hur, Won;Baek, Hwan-Jo
    • Economic and Environmental Geology
    • /
    • v.41 no.1
    • /
    • pp.57-62
    • /
    • 2008
  • The application of constructed subsurface-flow wetlands for treatment of wastewater from abandoned mines is being increased. Crushed limestone, oak chips, and mushroom composites are often employed in a bulk form, as the substrates in the bed media. Efficiency of the subsurface-flow treatment system drops with time as the hydraulic conductivity of the wetland soil decreases significantly, presumably due to chemical reactions with the wastewater. The purpose of this study is to investigate the applicability of immobilized beads carrying sulfate reducing bacteria for acid mine drainage treatment system. The ingredients of immobilized beads are organic materials such as mushroom composite and oak chips, limestone powder for a pH buffer, mixed with a modified Coleville Synthetic Brine. It was found that immobilized beads are more efficient than the bulk form for pH recovery, sulfate and heavy metal removal.

Effect of Additional Water on Durability and Pore Size Distribution in Cement Mortar (단위수량 증가에 따른 시멘트 모르타르의 내구성능과 공극분포에 관한 연구)

  • Kwon, Seung Jun;Lee, Hack Soo;Park, Sun Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.75-83
    • /
    • 2012
  • Porosity in concrete has close relationship with durability characteristics. Additionally mixed water can help easy mixing and workability but causes increased porosity, which yields degradation of durability performance. In this paper, cement mortar samples with 0.45 of w/c (water to cement ratio) are prepared and durability performances are evaluated with additional water from 0.45 to 0.60 of w/c. Various durability tests including strength, chloride diffusion, air permeability, saturation, and moisture diffusion are performed. Then they are analyzed with changing porosity. Changing ratios and the patterns of durability performance are quantitatively evaluated considering pore size distribution, total porosity, and additional water content.