• Title/Summary/Keyword: 투과량

Search Result 794, Processing Time 0.033 seconds

The Characteristics of Hydrogen Permeation through Pd-coated $Nb_{56}Ti_{23}Ni_{21}$ Alloy Membranes (Pd 코팅된 $Nb_{56}Ti_{23}Ni_{21}$ 합금 분리막의 수소투과 특성)

  • Jung, Yeong-Min;Jeon, Sung-Il;Park, Jung-Hoon
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • We make a studyof the hydrogen permeability and chemical stability of $Nb_{56}Ti_{23}Ni_{21}$ metal alloy membrane. For this purpose, we produced the $Nb_{56}Ti_{23}Ni_{21}$ membrane which has 10 mm diameter and 0.5 mm thick, and experiment the hydrogen transport properties under two kinds of feed gas ($H_2$ 100%; $H_2$ 60% + $CO_2$ 40%) at $450^{\circ}C$C with variation of absolute pressure.The maximum hydrogen permeation flux was $5.58mL/min/cm^2$ in the absolute pressure 3 bar under pure hydrogen. And each case of feed gases about gas composition, the permeation fluxes were satisfied with Sievert's law, and the hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of temperature and pressure. After permeation test, we experiment the stability and durability of $Nb_{56}Ti_{23}Ni_{21}$ alloy membrane for carbon dioxide by XRD analysis.

Effects of CO and $CO_2$ on Hydrogen Permeation through Pd-coated V-Ti-Ni Alloy Membranes (Pd 코팅된 V-Ti-Ni 합금 분리막을 통한 수소투과에서 CO와 $CO_2$의 영향)

  • Jeon, Sung-Il;Park, Jung-Hoon;Lee, Yong-Taek
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.290-298
    • /
    • 2011
  • The influence of co-existing gases on the hydrogen permeation was studied through a Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane. The hydrogen permeation characteristics of Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane have been investigated in the pressure range 1-3 bar under pure hydrogen and hydrogen mixture gas with carbon dioxide and carbon monoxide at $450^{\circ}C$. Preliminary hydrogen permeation experiments have been confirmed that hydrogen flux was $5.36mL/min/cm^2$ for a Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane (thick: 0.5 mm) using pure hydrogen as the feed gas. In addition, hydrogen fluxes were 4.46, 5.20, $3.91mL /min/cm^2$ for$V_{53}Ti_{26}Ni_{21}$ alloy membrane using $H_2/CO_2$, $H_2/CO$ and $H_2/CO_2/CO$ as the feed gas respectively. Therefore, the hydrogen permeation flux decreased with decrease of hydrogen partial pressure irrespective of temperature and pressure when $H_2/CO_2$, $H_2/CO$ and $H_2/CO_2/CO$ mixture applied as feed gas respectively and permeation fluxes were satisfied with Sievert's law in different feed conditions. It was found from XRD results after permeation test that the Pd-coated $V_{53}Ti_{26}Ni_{21}$ alloy membrane had good stability and durability for various mixtures feeding condition.

Pervaporation process simulation for ethanol dehydration (에탄올 탈수를 위한 투과증발 공정 모사)

  • 이규현;유제강;장재화;안승호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.38-39
    • /
    • 1995
  • 최근 자동차 대체 연료로 가솔린에 10% 무수에탄올이 혼합된 Gasohol 사용에 관한 관심이 고조되고 있으며, 이는 Gasohol이 자동차 배기 가스중의 일산화탄소 및 탄화수소 함유량을 감소시켜 대기 오염을 줄일 수 있기 때문이다. Gasohol에 사용되는 무수에탄올의 농도는 99.5% 이상이어야 하며, 이러한 고순도의 에탄올을 제조하기 위해서는 물과 에탄올의 공비 혼합물(95.6% 에탄올)로부터 공비증류, 분자체 흡착, 투과증발과 같은 분리 조작을 이용하여 물을 제거하는 공정이 필요하다. 현재 에탄올 탈수에는 공비증류가 많이 사용되고 있으나 공비증류는 에너지 사용량이 많을 뿐더러 유독한 Entrainer를 첨가하기 때문에 투과증발과 같은 저 에너지 소비형, 환경친화적인 공정으로의 전환이 이루어지고 있다. 에탄올 탈수용 투과증발 플랜트는 전세계 20여개가 가동되고 있으며, 상업화된 플랜트의 대부분은 독일의 Deutsche Carbone사가 제조한 PVA/PAN 투과증발 복합막을 사용하고 있다. 투과증발 시스템은 물에 대한 친화도가 높은 투과증발막 및 모듈, 기타 분리 구동력을 높여주기 위한 Heater, 진공펌프, 냉각기, 열 교환기 등의 주변 설비로 구성되며, 투과증발 시스템 개발을 위해서는 우수한 막/모듈 제조와 아울러 최적 공정 설계 기술 개발이 필수적이라 하겠다.

  • PDF

UF 및 MF 중공사막의 오염 및 세정특성

  • 이주형;이용택;김정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.166-168
    • /
    • 1998
  • 막분리공정에서 분리막 오염은 투과율 감소에 큰 영향을 받는데 그 이유는 주로 막재질의 변질 및 막 표면에서의 농도 분극 현상에 기인하고 분리막의 종류 및 분획분자량의 차이에 따라 막분리 능력이 달라질 수 있다. 본 연구에서는 상용화되어 있는 UF/MF 중공사막에 미치는 막오염 정도와 세정 특성을 알아보았다. 막오염 정도는 막의 Pore size, 소재, 막구조에 따라서 단백질 수용액을 처리하여 막의 오염이 어떻게 일어나는지를 알아보았고 막오염 정도를 검토하기 위하여 초기순수에 대한 흡착후 투과량을 DOF(Degree of fouling)로 정의하였다. 막의 세정특성은 0.1N-NaOH을 사용하여 화학적 세정효과를 확인하였고 초기 순수에 대한 세정후 회복정도를 DOC(Degree of Cleaning)로 정의하였다. 또한 UF막에서 분획분자량별 특성과 MF막에서 소재별/구조적 특성이 DOF와 DOC에 미치는 영향에 대해서 알아보았다.

  • PDF

A Study on the Calculation of Cavity Filling Amount Using Ground Penetrating Radar and Cavity Shaping Equipment (지표투과레이더와 공동형상화 장비를 이용한 공동채움량 산정 연구)

  • Hong, Gigwon;Kim, Sang Mok;Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.261-268
    • /
    • 2022
  • Purpose: In the case of cavity discovered by ground penetrating radar exploration, it is necessary to accurately predict the filling amount in the cavity in advance, fill the cavity sufficiently and exert strength to ensure stability and prevent ground subsidence. Method: The cavity waveform analysis method by GPR exploration and the method using the cavity shape imaging equipment were performed to measure the cavity shape with irregular size and shape of the actual cavity, and the amount of cavity filling of the injection material was calculated during rapid restoration. Results: The expected filling amount was presented by analyzing the correlation between the cavity size and the filling amount of injection material according to the cavity scale and soil depth through the method by GPR exploration and the cavity scale calculation using the cavity shaping equipment. Conclusion: The cavity scale measured by the cavity imaging equipment was found to be in the range of 20% to 40% of the cavity scale by GPR exploration. In addition, the filling amount of injection material compared to the cavity scale predicted by GPR exploration was in the range of about 60% to 140%, and the filling amount of the injection material compared to the cavity size by the cavity shaping equipment was confirmed to be about 260% to 320%.

A Qualitive Research of N2, O2 Permeation Property in PMDA/ MDA- Phenylene Diamine Copolyimide (PMDA/MDA-Phenylene diamine 계열의 공중합체막에서의 산소, 질소 투과 특성의 정성적 고찰)

  • Lee, Kyung-Rok;Na, Seong-Sun;Kim, Jong-Pyo;Min, Byoung-Ryul
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.13-19
    • /
    • 1998
  • Copolyimide membranes of different chemical structure based on pyromellitic dianhydride (PMDA)/methylendianiline(MDA) were prepared by varying their chemical compositions with adding meta-phenylendiamine (MPD), para- phenylendiamine (PPD), 2,4,6- trimethyl-1,3-phenylenediamine(TriMeMPD) as a co-monomer. The $N_2$ and $O_2$ permeation properties are qualitatively correlated to specific free volume and intersegmental distance of membrane. The partial replacement of MDA with MPD or PPD caused in the PMDA/MDA based membranes increase in density, and decrease in free volume, d-spacing, consequently resulted in decreased permeability coefficient. In the case of TriMeMPD, opposite results were observed. In all membranes, the permeability coefficients were pressure independent, and membranes which have high permeability coefficient showed low $N_2/O_2$ ideal separation factor as an usual manner. The permeability coefficient also increased with temperature and $N_2/O_2$ ideal separation factor decreased. The increase ratio of the $N_2$ permeability coefficient was larger than that of $O_2$.

  • PDF

The Optimization of Removal Process of Humic Acid by Polysulfone Hollow-fiber Membrane (폴리설폰 중공사막에 의한 부식산 제거공정의 최적화)

  • Song, Kun-Ho;Lee, Kwang-Rae;Lee, Chan-Ki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1273-1284
    • /
    • 2000
  • In this study, ultrafiltration was performed to remove humic acid from aqueous solution. Since the effects of system variables on the ultrafiltration were tangled with non-linearly. Response Surface Methodology(RSM) was used to know optimum conditions of ultrafiltration process, relations among system variables, and the effects of system variables such as pressure difference across the membrane, concentration of humic acid, and feed flow rates. As concentrations of humic acid were 10ppm, 40ppm, and 70ppm in feed stream, permeation fluxes were 2.56, 2.27, and $2.10({\times}10^{-2}cc/cm^2{\cdot}min)$ respectively ; in other words, permeation fluxes of 10ppm, 40ppm and 70ppm feed concentration decreased by 17.7%, 26.7% and 32.2% of pure water permeation flux respectively. Concentration of humic acid in permeate side were 0.5ppm, 1.2 ppm, and 2.1ppm respectively. When pressure difference(${\Delta}P$) increased from 1atm to 2atm and 3atm, permeation fluxes of 40ppm feed concentration increased by 66% and 152% of permeation rate at 1atm respectively. However, concentrations of humic acid in permeate side increased from 0.5ppm to 1.5ppm and 3.5ppm. RSM showed that the optimum condition of system variables is 38.5~40ppm of humic acid concentration in feed stream, 30~30.7cc/min of feed flow rate, and 2atm of pressure difference.

  • PDF

Preparation of Hydrophobic Porous PVDF Membrane and Application for Membrane Distillation (소수성 다공질 PVDF 중공사 분리막 제조 및 막증류 적용)

  • Min, Ji Hee;Park, Min Soo;Kim, Jinho
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.240-248
    • /
    • 2014
  • Porous PVDF hollow fiber membranes were prepared by hybrid process of TIPS(thermally induced phase separation) and stretching for membrane distillation. The tests were conducted to investigate that permeability of the membrane could be enhanced by reducing membrane wall thickness. During fiber spinning, dope discharge rate from nozzle was reduced and flow rate of bore fluid increased to make the wall thickness thinner. As dope discharge rate from nozzle was reduced and flow rate of bore fluid increased, the membrane wall thickness was reduced. As a result, air permeability, water permeability and vapor permeability of the membranes increased.

Evaluation of Ultrafiltration Membrane Using Gel Permeation Chromatography (GPC를 이용한 한외여과막의 평가)

  • 정건용;정동진;김천호;신현수;민병렬;김래현
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.81-87
    • /
    • 2003
  • The permeation experiments f3r the aqueous dextran solutions of which the molecular weights were distributed between several thousands and million daltons were carried out using the dead-end cell system equipped with sheet membrane to determine the molecular weight cut-off (MWCO) of ultrafiltration membranes. The dextran rejections with respect to molecular weight were obtained by GPC analysis of feed and permeate solutions, then the MWCO was decided as the dextran molecular weight corresponding to the 90% rejection. The MWCO of PBTK membrane manufactured by Millipore was varied between 63,000 and 68,000 daltons as the pressure increased from 0.5 to 2.0 bar. However, the MWCO of PBQK(Millipore) and UE 1812(Saehan) under the above operating pressure increased to 3.5 and 4.3 times, respectively. Also, the MWCO of PBTK increased to 25% as the membrane permeation increased from 10 to 40% of the feed solution.