• Title/Summary/Keyword: 톨루엔 증기

Search Result 21, Processing Time 0.025 seconds

Preparation of Pt Catalyst Supported on Zeolite Sheet and Its Performance of Toluene Combustion (제올라이트 쉬트 담지 백금촉매의 제조 및 톨루엔 연소 특성)

  • Kim, Jin-Bae;Im, Na Rae;Kim, Hong Soo;Yoo, Yoon Jong
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.323-327
    • /
    • 2011
  • A zeolite sheet (ceramic paper containing zeolite) made in a cylindrical configuration can be applied to a honeycomb rotor for the effective VOC removal. In this study, the zeolite sheet containing ZSM-5 was used as a support for Pt-loading, and its catalytic activity for the toluene combustion reaction was compared with those of the other Pt catalysts loaded on ${\gamma}-Al_2O_3$ and cordierite honeycomb. Pt/zeolite sheet catalyst showed a higher activity for toluene combustion reaction than that of $Pt/{\gamma}-Al_2O_3$ or Pt/cordierite honeycomb. On the other hand, the dispersion of Pt particles loaded on the zeolite sheet was improved by the pretreatment with $NH_3-H_2O$ vapor at room temperature. Consequently, the pretreatment of Pt/zeolite sheet by $NH_3-H_2O$ vapor significantly enhanced the catalytic activation for toluene combustion reaction.

Comparison of Adsorption and Desorption Characteristics of Acetone Vapor and Toluene Vapor on Activated Carbons According to Pore Structure (활성탄의 기공구조에 따른 아세톤 증기와 톨루엔 증기의 흡착 및 탈착특성 비교)

  • Lee, Song-Woo;Na, Young-Soo;An, Chang-Doeuk;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.21 no.10
    • /
    • pp.1195-1202
    • /
    • 2012
  • The purpose of this work is to study the adsorption and desorption characteristics of acetone vapor and toluene vapor from adsorption tower in the VOCs recovery device. The six kinds of activated carbon with different pore structures were used and the adsorption and desorption characteristics were compared according to pore structure, desorption temperature, and adsorption method, respectively. Adsorption capacity of acetone vapor and toluene vapor by batch method was higher than that by dynamic method. Especially, activated carbon with medium-sized or large pores had more difference in adsorption capacity according to adsorption methods as a result of gradually condensation of vapors on relatively mesopore and large pores. Activated carbons with relatively large pores and relatively small saturated adsorption capacity had excellent desorption ability.

Adsorption Analysis of VOCs of Zeolite Synthesized by Coal Fly Ash in a Fixed-bed Adsorber (고정층 흡착탑에서 석탄비산재로부터 합성한 Zeolite의 VOCs 흡착 해석)

  • Kim, Seong-Soo;Lee, Chang-Han;Park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.784-790
    • /
    • 2010
  • VOCs such as acetone, benzene, toluene, ethylbenzene were adsorbed in a fixed-bed adsorber using zeolite synthesized from coal fly ash and 4 kinds of activated carbon at 101.3 kPa. The adsorber was operated batchwise with the charge of 5 g adsorbent to obtain the breakthrough curve of VOCs. Experiments were carried out at $40^{\circ}C$, nitrogen flow rate of $70cm^3/min$ and sparger temperature of $30^{\circ}C$. The deactivation model was tested for these curves by combining the adsorption of VOCs and the deactivation of adsorbent particles. The observed values of the adsorption rate constant and the deactivation rate constant were evaluated through analysis of the experimental breakthrough data using a nonlinear least square technique. The experimental breakthrough data were fitted very well to the deactivation model than the adsorption isotherm models in the literature. Also, adsorption capacities of adsorbents were obtained from the breakthrough curve to observe the correlation between adsorption capacity and the physical properties of VOCs.

A Study on Flash Points of Flammable Substances- 1. Pure Substances and A Mixture of Binary System - (가연성물질의 인화점에 관한 연구- 1. 순수성분 및 2성분계 혼합물-)

  • 하동명;목연수;최재욱
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 1999
  • The flash point is generally used as a hazardous index of fire and explosion of a flammable liquid. A classification of the flash points is important for the safe handling of flammable liquids such as solvent mixtures. The flash points of pure substances and solvent mixtures can be c calculated with the appropriate use of the fundamental laws of Raoult, Dalton, Le Chatelier and a activity coefficient models. In this study, experimentally determined lower and upper flash points w were compared with the calculated values by using Raoult's law and van Laar equation. The flash points of pure substances were in agreement with the calculated values by vapor pressure and e explosive limits. Also, the lower flash points of M.E.K(methylethylketone)-toluene system were i in agreement with the predicted values by Raoult’s law, and the upper flash points were in a agreement with the predicted values by van Laar equation. By means of this methodology, it is possible to evaluate reliability of expermental data of the flash points of the flammable mixtures.

  • PDF

Removal Characteristics of Single and Binary Vapors of Acetone, Toluene, and Methyl Mercaptan by Cylindrical UV Reactor Installed with TiO2-Coated Perforated Plane (TiO2를 코팅한 다공판을 설치한 원통형 UV 반응기에 의한 아세톤, 톨루엔, 메틸메르캅탄 단일 증기 및 2성분 혼합증기의 제거특성)

  • Jeon, Jin-Woo;Kam, Sang-Kyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.24 no.3
    • /
    • pp.317-322
    • /
    • 2015
  • The photocatalytic decomposition characteristics of toluene, acetone, and methyl mercaptan (MM) by UV reactor installed with $TiO_2$-coated perforated plane were studied. The removal efficiency of single toluene, acetone, and MM vapor was increased with increasing oxygen concentration, but decreased with increasing inlet concentration. Elimination capacity of single toluene, acetone, and MM vapor was obtained to be $628g/m^3{\cdot}day$, $1,041g/m^3{\cdot}day$, and $2,158g/m^3{\cdot}day$, respectively. Also, the photocatalytic decomposition of binary vapor consisted of toluene and acetone, toluene and MM, acetone and MM were observed. Elimination capacity of toluene mixed with acetone, toluene mixed with MM, acetone mixed with toluene, acetone mixed with MM, MM mixed with toluene, and MM mixed with acetone was $327g/m^3{\cdot}day$, $512g/m^3{\cdot}day$, $128g/m^3{\cdot}day$, $266g/m^3{\cdot}day$, $785g/m^3{\cdot}day$ and $883g/m^3{\cdot}day$, respectively. The inhibitory effect of acetone was higher than MM in photocatalytic decomposition of toluene, the inhibitory effect of toluene was higher than MM photocatalytic decomposition of acetone, and the inhibitory effect of toluene was higher than acetone in photocatalytic decomposition of MM.

Effect of Benzene, Acetone, and Methyl Mercaptan Vapor on Photocatalytic Decomposition of Toluene Vapor (톨루엔의 광촉매 분해시 벤젠, 아세톤 및 메틸메르캅탄 증기가 미치는 영향)

  • Kam, Sang-Kyu;Jeon, Jin-Woo;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1971-1976
    • /
    • 2014
  • In this study, the photocatalytic decomposition characteristics of single toluene, toluene mixed with benzene, toluene mixed with acetone, and toluene mixed methyl mercaptan (MM) by UV reactor installed with $TiO_2$-coated perforated plate were studied. The photocatalytic decomposition rate of single toluene, toluene mixed with benzene, toluene mixed with acetone, and toluene mixed with MM fitted well on Langmuir-Hinshelwood (L-H) kinetics equation. The maximum elimination capacity was obtained to be $628g/m^3{\cdot}d$ for single toluene, $499g/m^3{\cdot}d$ for toluene mixed with benzene, $318g/m^3{\cdot}d$ for toluene mixed with acetone, and $513g/m^3{\cdot}d$ for toluene mixed with MM, respectively. The negative effect in photocatalytic decomposition of toluene are found to be in the order of acetone>benzene>MM.

Degradation of TPHs, TCE, PCE, and BTEX Compounds for NAPLs Contaminated Marine Sediments Using In-Situ Air Sparging Combined with Vapor Extraction (증기추출법과 결합된 공기주입법을 이용한 비수용성액체 해양퇴적물의 TPHs, TCE, PCE 및 BTEX 정화)

  • Lee, Jun-Ho;Han, Sun-Hyang;Park, Kap-Song
    • Economic and Environmental Geology
    • /
    • v.46 no.5
    • /
    • pp.425-444
    • /
    • 2013
  • This study was carried out in order to determine the remediation of total petroleum hydrocarbons (TPHs), trichloroethylene (TCE), perchloroethylene (PCE), benzene, toluene, ethylbenzene and xylenes (BTEX) compounds for non-aqueous phase liquids (NAPLs) using in-situ air sparging (IAS) / vapor extraction (VE) with the marine sediments of Mandol, Hajeon, Sangam and Busan, South Korea. Surface sediment of Mandol area had sand characteristics (average particle size, 1.789 ${\Phi}$), and sandy silt characteristics (average particle size, 5.503 ${\Phi}$), respectively. Sangam surface sediment had silt characteristics (average particle size, 5.835 ${\Phi}$). Sediment characteristics before experiment in the Busan area showed clay characteristics (average particle size, 8.528 ${\Phi}$). TPHs level in the B1 column of Mandol, Hajeon, Sangam, and Busan sediments were 2,459, 6,712, 4,348, and 14,279 ppm. B2 (3 L/min) to B5 (5 L/min) columns reduced 99.5% to 100.0% of TCE and 93.2% to 100.0% of PCE. Removal rates of TCE, PCE, and BTEX are closely correlated (0.90-0.99) with particle sizes and organic carbon concentrations. However, TPHs (0.76) and benzene (0.71) showed the poorer but moderate correlations with the same parameters.

Method to Derive the Optimal Vent Position when Flammable Liquid Leaks Based on CFD (CFD 기반 인화성 액체 누출 시 최적의 환기구 배치 도출 방안)

  • Eun-Hee Kim;Seung-Hyo An;Jun-Seo Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.11-18
    • /
    • 2024
  • If flammable liquid leaks, vapor evaporated from the pool can cause poisoning or suffocation to workers, leading to secondary accidents such as fires and explosions. To prevent such damage, ventilation facilities shall be installed when designing indoor workplaces. At this time, the behavior varies depending on the characteristics of the leaked chemical, so it is necessary to select a suitable vent location according to the material. Therefore, 3D CFD simulations were introduced to derive optimal vent position and ventilation efficiency was quantitatively evaluated by vent position. At this time, assuming a situation in which flammable liquids leak at indoor workplaces to form pools, the concentration of vapor evaporated from pools was compared to derive the optimal vent position. As a result of research on toluene with high vapor density, ventilation efficiency was confirmed to be the highest at the upper supply-lower exhaust, and it is judged that introducing it can achieve about 3.7 times ventilation effect at the same maintenance cost. Through this study, it is expected that the workplace will be able to secure workers' safety by applying simulation results and installing ventilation ports.

Dual Photonic Transduction of Porous Silicon for Sensing Gases (이중의 광학적 변화를 이용한 다공성 실리콘 가스센서 제작)

  • Koh, Young-Dae;Kim, Sung-Jin;Jang, Seung-Hyun;Park, Cheol-Young;Sohn, Hong-Lae
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.99-104
    • /
    • 2007
  • Porous silicon exhibiting dual optical properties, both $Febry-P{\acute{e}}rot$ fringe (optical reflectivity) and photoluminescence had been developed and used as chemical sensors. Porous silicon samples were prepared by an electrochemical etch of p-type silicon wafer (boron-doped, <100> orientation, resistivity ; $1-10{\Omega}cm$). Two different types of porous silicon, fresh porous silicon (Si-H terminated) and oxidized porous silicon (Si-OH terminated)by the thermal oxidation, were prepared. Then the samples were exposed to the vapor of various organics, such as methanol, acetone, hexane, and toluene. Both reflectivity and photoluminescence were simultaneously measured under the exposure of organic vapors for sensing VOC's. These surface-modified samples showed unique respond in both reflectivity and photoluminescence with various organic vapors. While polar molecules exhibit greater quenching photoluminescence, molecules having higher vapor pressure show greater red shift for reflectivity.

Adsorption Characteristics of Toluene Vapor According to Pore Structures of Zeolite 5A Modified with Hydrochloric Acid (산으로 개질한 Zeolite 5A의 세공구조에 따른 Toluene Vapor의 흡착특성)

  • Lee, Song-Woo;Bae, Sang-Kyu;Kwon, Jun-Ho;Na, Young-Soo;An, Chang-Doeuk;Yoon, Young-Sam;Song, Seung-Koo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.8
    • /
    • pp.807-812
    • /
    • 2005
  • This study is to investigate the correlation of pore structures of Zeolite 5As modified with acid and their adsorption capacity of toluene vapor using the dynamic adsorption method. The experimental results showed that the modification with acid allowed more micropores and enlarged the existing pores. Toluene vapor was mainly adsorbed on the surface of pores over $15\;{\AA}$ in diameter. The equilibrium adsorption capacity of toluene vapor of the modified Zeolite 5As was in the range of $15{\sim}70\;mg/g$ and the equilibrium adsorption capacity was increased to f times than that of the Zeolite 5A. The correlation between the total cumulative surface area and the equilibrium adsorption capacity was hard to say linear. The correlation in diameter between the cumulative surface area in the range of over $15\;{\AA}$ and the equilibrium adsorption capacity gate the highest correlation factor of 0.997.