• Title/Summary/Keyword: 탱크 컨테이너

Search Result 14, Processing Time 0.029 seconds

Internal Pressure Variation Analysis and Actual Holding Time Test on ISO LNG Tank Container (LNG 탱크 컨테이너의 내부압력 변화 분석 및 실제 홀딩타임 측정)

  • Ryou, Young-Don;Lee, Jin-Han;Jo, Young-Do;Oh, Young-Sam;Cha, Kyong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.1-7
    • /
    • 2013
  • Internal pressure variation analysis and actual holding time test on ISO LNG tank containers which were made in Korea for the first time according to the special notification of ISO tank container manufacture have been conducted during the transport demonstration projects of the tank containers by tractor, train and ship. The internal pressure of the LNG tank container increased rapidly after LNG filling and dropped during moving the container. However, it was stabilized as time passed and followed the liquid-vapor equilibrium graph. In addition, actual holding time of the tank container was more than 20 days which was satisfied with the special notification of LNG tank container manufacture.

A Study on Improvement of Operation Process and Management Plan for Tank Container (Tank 컨테이너 운영프로세스 및 관리방안 개선에 관한 연구)

  • Park, Dong-Jin;Kim, Hwan-Seong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2019.11a
    • /
    • pp.191-192
    • /
    • 2019
  • The transport market has continued to change to provide services for each cargo. Currently, tank containers are widely used for the transport of liquids, and the tank container transportation market is continuously growing. Accordingly, the demand for handling for tank containers is also increasing. The purpose of this study is to suggest the improvement of transportation process and management method based on the case analysis of the current tank container transportation market. Therefore, this is paper suggests that an integrated system is needed to eliminate the period of information disconnection, secure information continuity, and improve the efficiency of managing dangerous goods.

  • PDF

Study on the numerical simulation of bird strike for composite container of external auxiliary fuel tank for rotorcraft (회전익항공기 외부 보조연료탱크용 복합재 컨테이너 조류충돌 수치모사 연구)

  • Kim, Hyun-Gi;Kim, Sungchan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.709-713
    • /
    • 2017
  • In urgent situations such as crashes, the integrity of an aircraft's fuel tank is directly related to the survivability of the crew. Thus, an external auxiliary fuel tank should be robust against bird strikes. In this study, a numerical analysis was carried out using impact analysis software to analyze the influence of bird strike on a composite container for an external auxiliary fuel tank. The structure was modeled as a shell element, and the fluid and bird were modeled by the particle method. The behavior of the internal fluid was also examined. The maximum stress, deformation, and strain of the composite container were also calculated.

A Study and Design on Tank Container for Fuel Tank of LNG Fueled Ship (LNG 연료 추진선의 연료 탱크로서 탱크컨테이너의 적용성 연구 및 구조설계)

  • Kim, Tae-Woo;Suh, Yong-Suk;Jang, Ki-Bok;Chun, Min-Sung;Lee, Kang-Dae;Cha, Kyong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.6
    • /
    • pp.504-511
    • /
    • 2012
  • The objective of this study is to investigate tank container to be used as fuel tank for LNG fueled ship. Feasibility of tank container to the fuel tank of LNG fueled ship is addressed and the advantage of tank container as fuel tank of ship is investigated. Conceptual configuration of the tank container is designed as well as structural analyses based on finite element method are carried out to meet the design regulation suggested by shipping register. Static loading is considered by structural analysis and impact test is performed. It is necessary to require SRS(shock response spectrum) in order to investigate structural safety which can meet.

Study on the Numerical Analysis of Crash Impact Test for External Auxiliary Fuel Tank based on ALE (ALE 기반 외부 보조연료탱크 충돌충격시험 수치해석 연구)

  • Kim, Hyun-Gi;Kim, Sungchan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.8-13
    • /
    • 2018
  • A fluid-structure interaction analysis should be performed to evaluate the behavior of the internal fuel and its influence in order to confirm the structural soundness of the fuel tank against external impacts. In the past, fluid-structure interaction analyses have been limited to the obtention of numerical simulation results due to the need for considerable computational resources and excessive computation time. However, recently, computer performance has been dramatically improved, enabling complex numerical analyses such as fluid-structure interaction analysis to be conducted. Lagrangian and Euler coupling methods and Lagrangian based analysis methods are mainly used for fluid-structure interaction analysis. Since both of these methods have their advantages and disadvantages, it is necessary to select the more appropriate one when conducting a numerical analysis. In this study, a numerical analysis of a crash impact test for a fuel tank is performed using ALE. The purpose of the numerical analysis is to estimate the possibility of failure of the fuel tank mounted inside the container when it is subjected to a crash impact. As a result of the numerical analysis, the fluid behavior inside the fuel tank is investigated and the stress generated in the fuel tank and the container structure is calculated, thereby enabling the possibility of fuel tank failure and leakage of the internal fluid to be evaluated.

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.

Assessment of Structural Soundness and Joint Load of the Rotorcraft External Fuel Tank by Sloshing Movement (슬로싱 운동에 의한 회전익항공기 외부연료탱크 체결부 하중 및 구조건전성 평가)

  • Kim, Hyun-Gi;Kim, Sung Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.605-611
    • /
    • 2019
  • The fuel sloshing due to the rapid manoeuvre of the aircraft causes significant loads on internal components, which may break components or piping. In particular, a significant load is applied to the joint of the external fuel tank by sloshing movement, which may affect the safety of the aircraft when the joint of the external fuel tank is damaged. Therefore, in order to improve the survivability of aircraft and crew members, the design of external fuel tanks, and joints should be performed after evaluating the sloshing load through a numerical analysis of the fuel sloshing conditions. In this paper, a numerical analysis was performed on the sloshing test of the external fuel tank for rotorcraft. ALE (Arbitrary Lagrangian Eulerian) technique was used, and the test conditions specified in the U.S. Military Specification (MIL-DTL-27422D) was applied as the conditions for numerical analysis. As a result of the numerical analysis, the load on the joint of the external fuel tank was calculated. Moreover, the effects of sloshing movement on structural soundness were assessed through analysis of stress levels and margin of safety on metal fittings and composite containers.

A Preliminary Study of Railway Transport of LNG between TKR~TSR (TKR~TSR간 LNG 철도수송 연계를 위한 기초연구)

  • Ha, Oh-Keun;Hwang, Jae-Sik;Kim, Ick-Hee;Mun, Young-Woo
    • Land and Housing Review
    • /
    • v.6 no.2
    • /
    • pp.61-66
    • /
    • 2015
  • This study is the realization of natural gas as ways to advance the South and the continental railway linking basic research was conducted on railway transport. Summary data on the Status of North Korean railway which was to have reviewed the case of LNG railway transportation in Japan and China is becoming an LNG tank containers by rail transportation is done. In the case of Korea, the stability of railway transportation through the development of LNG tank containers and rail transportation pilot project was tested. It was set up and the basic directions of freight trains transport routes and methods for rail transport 7.5 million tons of natural gas per year. TKR ~ TSR between the LNG transportation business is an existing railway south. North. Russia gas pipeline (PNG) instead of a separate project to replace the business SRX (Silk Road Express) is a symbolic project for the early realization of the Eurasian railway linking policy. This study may give greater meaning to secure the iconic railway transport route for continental transport of containers and bulk cargo (coal, ores, etc.).

Structural Design and Analysis of Barge for Canal-Coastal Shipping (운하-연안 연계용 바아지의 구조 설계 및 해석)

  • Kim, Kyung-Su;Son, Choong-Yul;Kim, Sung-Joon
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.26-34
    • /
    • 1999
  • Two types of barge, container and tanker vessels, are designed with specific dimensions for canal-coastal shipping in Kyung-In canal and Yellow Sea region. The principal dimensions of barges are determined by considering the environment of Kyung-In canal and Yellow Sea. The selection of structure type and structure type and strength confirmation is conducted by the technical rules of Korean Register of Shipping. For the structural analysis of designed barges, the semi-direct stuctural analysis is carried out with using MSC NASTRAN software. Applying identical dimensions to both vessels, the standardization of structural design and analysis procedure are introduced.

  • PDF

A Study on the Improvement of Safety of Unloading Site by Comparison of Hydrogen Fluoride Leakage Accident (불화수소 누출사고 비교를 통한 하역작업장의 안전성 향상방안에 관한 연구)

  • Woo, Jongwoon;Shin, Changsub
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.32-38
    • /
    • 2018
  • The purpose of this study is to assess quantitatively the amount of leaks and the extent of dispersion in case of a leak at a hydrogen fluoride tank container unloading station, and to suggest a safety improvement plan to prevent recurrence of similar accidents. In 2012, Company H leaks 8 tonnes of tank containers with a maximum storage capacity of 18 Ton, causing it to become a social issue. As a result of calculation using Gaussian plume model, the concentration was estimated to be more than 20ppm from the leak point to 1,321 m radius. The leakage of hydrogen fluoride from the company R in 2014 was estimated to be 11.02 kg, of which 2.9 kg was treated by the scrubber. As a result of calculation using Gaussian plum model, the damage range with a concentration of 20ppm or more from the leak source was estimated to be 69 m in radius. As a result of comparing the above two accidents, it was found that the leakage amount was about 987 times different and the damaged site was more than 19 times different. Therefore, it was concluded that it was necessary to control the wearing of the protective equipment, the enclosure of the unloading site, the installation of the scrubber, and the emergency training to avoid the accidental leakage of a hydrogen fluoride from the unloading site.