• 제목/요약/키워드: 태양열 획득계수

검색결과 4건 처리시간 0.02초

NFRC 201 실험방법에 의한 내부 차양장치가 적용된 창호의 일사획득계수 평가 (Evaluation on the Solar Heat Gain Coefficient of Glazing System installed in internal shading device by experiments according to the NFRC 201)

  • 임재한;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.47-54
    • /
    • 2010
  • Recently the researchers has been interested in the development of the high performance windows such as solar control window using automatic shading devices, air-flow window, selective coating window. In order to assess the energy performance of total fenestration system, the net energy gains or losses through the glazings and windows should be evaluated. It depends on the thermal transmittance (U-value) and the total solar energy transmittance (SHGC, g-value). This study aims to measure the solar heat gain coefficient according to the NFRC 201 standard test method. In results, we could find the result of different SHGC of the glazing system with a different slat angles. The SHGC in case of $90^{\circ}$ of internal slat angle with regard to the window surface is about 0.56, that in case of $45^{\circ}$ is about 0.49 and that in case of $0^{\circ}$ is about 0.33. Significant dependence on the solar radiation intensity and incident angle was found in comparison of the measured and simulated SHGC.

TEST CELL에서 단기측정에 의한 열성능 평가 (Thermal Performance Evaluation of a Test Cell Thru Short Term Measurements)

  • 전명석;윤환기;천원기;전홍석
    • 태양에너지
    • /
    • 제10권2호
    • /
    • pp.10-17
    • /
    • 1990
  • 건물의 사양으로부터 시뮬레이션에 의해 열성능을 추출하는 기법과 실측 데이타로 부터 연역적인 방법에 의해 열성능을 추출하는 기법을 연합시켜 단기간의 측정에 의해 건물의 열성능을 간단하고 정확하게 결정할 수 있는 기법을 Test cell에 적용하였다. 실험과정 및 자료분석은 PSTAR 기법에 따라 수행했다. 각 측정기간은 3일간으로 비거주 상태에서 측정했으며, 실내온도, 외기온, 일사량, 공급열량, 풍속, 상대습도등의 자료를 측정하여 건물의 사양에 의한 시뮬레이션 모델의 재표준화에 사용했다. 아래의 3개 주요계수들이 본 분석에 의해 얻어졌다. 1) 건물 열손실계수 : BLC(표면전도율+침기에 의한 전도율); 2) 유효 건물열용량; 3) 유효 태양열 획득량. 그리고 재표준화된 식으로부터 예측된 값과 건물의 사양으로 시뮬레이션에 의해 예측된 값과 측정된 값과의 비교를 통해 재표준화된 식이 실제건물의 열성능을 잘 묘사함을 알 수 있었다. 장기간의 외삽으로 기후 자료를 이용하여 표준 쾌적도를 유지하기 위해 필요한 에너지를 계산했다.

  • PDF

창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가 (Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea)

  • 임희원;김동윤;이수만;안정혁;윤종호;신우철
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

1분 강우자료를 이용한 RUSLE의 강우침식도 추정 연구 (A Study on Estimation of Rainfall Erosivity in RUSLE by Using Minute Unit Rainfall Data)

  • 정충길;장원진;이지완;안소라;김성준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.114-114
    • /
    • 2016
  • 토양유실에 영향을 미치는 기후 인자로는 강우, 기온, 바람, 습도 및 태양열 복사 등이 있다. 이들 중 강우는 토양침식에 직접적인 영향을 미치는 인자로 토립장의 이탈로 인한 토양침식을 유발한다. 토양침식을 예측하는데 있어 강우의 영향을 나타내는 지표의 설정은 매우 중요하다. 이러한 강우침식인자는 각 강우사상에 대한 강우에너지와 30분 최대 강우강도의 곱의 합으로 정의된다. 강우침식도를 정확하게 계산하기 위해서는 다년간 측정된 분단위 강우자료가 필요하며, 강우자료 획득의 제한과 강우의 분류 및 계산과정 등이 복잡하여 실무적으로 산정하기 어려운 점이 있다. 본 연구에서는 1분 상세강우자료를 이용하여 개정범용토양유실공식(RUSLE)의 강우침식도 R의 추정을 위해 2001년부터 2015년까지 15년간 전국 61개 기상청 관측소의 강우 자료를 수집하여 지점별로 새롭게 계산한 연 강우침식도 및 경험식을 산정하였으며 남한전체($99,720km^2$)를 대상으로 연 강우침식량의 공간분포맵을 작성하였다. 지점별 산정된 경험식은 연평균 강우량과 1분 강우자료로부터 산정된 강우침식도와의 상관관계로 회귀식을 도출하였다. 1분 강우자료로 계산된 강우침식도와 연평균 강우량의 상관관계로부터 도출된 경험식과의 결정계수($R^2$, determination coefficient)는 0.70 ~ 0.98로 높은 상관관계를 나타냈으며 또한, 기존의 국내에서 적용된 경험식과 비교하여 평균 $R^2$가 0.59에서 0.80로 실측값과의 정확성이 높게 개선됨을 알 수 있다.