• Title/Summary/Keyword: 탐상주파수

Search Result 53, Processing Time 0.022 seconds

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

Experimental Evaluation of Fatigue Behavior and Interlaminar Phase in the Lightweight Piezoelectric Ceramic Composite Actuator Using the Ultrasonic C-scan Inspection (초음파 C-스캔 탐상을 이용한 경량 압전세라믹 복합재료 작동기의 피로거동과 계면변화의 관계 연구)

  • Kim Cheol-Woong;Nam In-Chang;Yoon Kwang-Joon
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1332-1336
    • /
    • 2005
  • It could make the LIghtweight Piezoelectric Composite Actuator (LIPCA) damageable by the cyclic large deformation. If the progressive microvoid coalescence of LIPCA interlaminar took place, the decrease of the stiffness and the weakness of stress transmission and fiber bridging effect would make the fatigue characteristics worse suddenly. Therefore, it is required to study the variation of fatigue behavior and interlaminar condition in LIPCA under resonant frequencies. These studies such as the changeable fatigue phase and interlaminar behavior of LIPCA affected by the resonant frequencies should be carried out due to the strong anisotropy of CFRP layer. Hence, these studies are as follows. 1) The residual stresses distribution of interlaminar in LIPCA using the Classical Lamination Theory (CLT). 2) Comparative analysis of interlaminar behavior for the intact LIPCA versus LIPCA containing an artificial delamination during resonant frequency.

  • PDF

Investigation of CT Imaging Technique Using Guided Wave (유도초음파를 이용한 판 구조물 CT 영상화 기법)

  • Yoon, Hyun-Woo;Kang, To;Kim, Hak-Joon;Song, Sung-Jin;Shin, Ho-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.11-18
    • /
    • 2011
  • Ultrasonic guided waves have been widely utilized for long range inspection of structures. Recently, many researchers have paid attention to the tomographic imaging using guided wave for the diagnosis of plate-like structures because group velocity of guided waves is changed by central frequency of transducer and thickness of plate. Currently, Delay and Sum imaging technique and MVDR(Minimum Variance Distortionless Response) imaging technique are performed. So the performance of these two imaging techniques are investigated in this paper.

A Study on the Crack Depth Measurements of Concrete by Tone-burst Flaw Detect Method (톤바스트 탐상법(探傷法)에 의한 콘크리트의 균열(龜裂)깊이 측정(測定)에 관한 연구(硏究))

  • Han, E.K.;Park, I.G.;Park, J.S.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.73-83
    • /
    • 1990
  • Recently, research on the non-destructive testing of concrete has been rapidly increasing in relation with the quality, reliability, durability, and uniformity of concrete used in architectural structures. In this paper, the most important problem is the attenuation phenomena on throughing the side of concrete by ultrasonic wave, and applied tone-burst to decrease the attenuation in minimum. As the result, the correlation between crack-depth and propagation-time, maximum-spectrum and out-amplitude, in-frequency and maximum-spectrum are found to be excellent. The coefficient of each are +0.975, +0.847, -0.718. The merit of tone-burst through this experiment is that the start of reception wave is very excellent.

  • PDF

Numerical Design of Shielded Encircling Probe for RFEC Testing of Nuclear Fuel Cladding Tube (핵연료 피복재 튜브의 원격장와전류 탐상을 위한 차폐된 관통형 탐촉자의 수치해석적 설계)

  • Shin, Young-Kil;Shin, Sang-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.650-657
    • /
    • 2001
  • This paper explains the process of designing a shielded encircling remote field eddy current (RFEC) probe to inspect nuclear fuel cladding tubes and investigates resulting signal characteristics. To force electromagnetic energy from exciter coil to penetrate into the tube, exciter coil is shielded outside by laminations of iron insulated electrically from each other. Effects of shielding and the proper operating frequency are studied by the finite element analysis and the location for sensor coil is decided. However, numerically simulated signals using the designed probe do not clearly show the defect indication when the sensor passes a defect and the other indication appeared as the exciter passes the defect is affected by the shape of shielding structure, which demonstrates that the sensor is directly affected by exciter fields. For this reason, the sensor is also shielded outside and this shielding dramatically improves signal characteristics. Numerical modeling with the finally designed probe shows very similar signal characteristics to those of inner diameter RFEC probe. That is, phase signals show almost equal sensitivity to inner diameter and outer diameter defects and the linear relationship between phase signal strength and defect depth is observed.

  • PDF

Inspection of Welded Zone and Flat Plate Using Flexible ECA Probe (Flexible ECA Probe를 이용한 평판 및 용접부 검사)

  • Lee, Chang-Jun;Lee, Kyu Sung;Shin, Chung-Ho;Lee, Kyoung-Jun;Jang, Yoon Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.288-294
    • /
    • 2016
  • This paper aims to compare the ability to detect notch defects existing in the plate and welded area using a flexible ECA (eddy current array) probe with OmniScan MX and MS-5800E. The characteristics of signals with various frequencies and lift-offs were also compared. As a result, when signals of frequencies 500, 1000, and 1500 kHz were used, the amplitude of the signal increased, as the depth of the notch increased, but reduced linearly in accordance with the lift-off variation. In addition, the detection sensitivity of the weld defect was found to be closely related to the contact surface of the probe and specimen. In this paper, it was demonstrated that the detection sensitivity was excellent when the contact surface of the probe and the specimen was sufficient, but it was poor when the contact surface was insufficient.

The Defect Inspection on the Irradiated Fuel Rod by Eddy Current Test (와전류시험에 의한 조사핵연료봉의 결함 검사)

  • Koo, D.S.;Park, Y.K.;Kim, E.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.29-33
    • /
    • 1996
  • The eddy current test(ECT) probe of differential encircling coil type was designed and fabricated, and the optimum condition of ECT was derived for the examination of the irradiated fuel rod. The correlation between ECT test frequency and phase & amplitude was derived by performing the test of the standard rig that includes inner notches, outer notches and through-holes. The defect of through-hole was predicted by ECT at the G33-N2 fuel rod irradiated in the Kori-1 nuclear power reactor. The metallographic examination on the G33-N2 fuel rod was Performed at the defect location predicted by ECT. The result of metallographic examination for the G33-N2 fuel rod was in good agreement with that of ECT. This proves that the evaluation for integrity of irradiated fuel rod by ECT is reliable.

  • PDF

The Study on Scattered Far-Field Analysis of Ultrasonic SH-Wave Using Boundary Element Method (경계요소법을 이용한 SH형 초음파 원거리 산란장 해석에 관한 연구)

  • Lee, Joon-Hyun;Lee, Seo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.333-339
    • /
    • 1999
  • It is well recognized that ultrasonic technique is one of the most common and reliable nondestructive evaluation techniques for quantitative estimation of defects in structures. For the quantitative and accurate estimation of internal defects. the characteristics of scattered ultrasonic wavefields must be understood. In this study. the scattered near-field and far-field due to a circular cavity embedded in infinite media subjected to incident SH-waves were calculated by the boundary element method. The frequency response of the scattered ultrasonic far-field was transformed into the time-domain signal by obtaining its inverse Fourier transform. It was found that the amplitude of time-domain signal decreases and its time delay increases as the distance between the detecting point of ultrasonic scattered field and the center of internal cavity increases.

  • PDF

Determination of Impact Source Location Using a Single Transducer and Time Reversal Technique (단일센서와 시간역전법을 이용한 판에서의 충격위치 결정에 관한 연구)

  • Jeong, Hyun-Jo;Cho, Sung-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a plate structure is presented in this paper. The method employs a single sensor and spatial focusing of time reversal (TR) acoustics. We first examine the TR focusing effect at the impact position and its surroundings through simulation and experiment. The imaging results of impact points show that the impact source location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testings of plate-like structures.

A Study on Suppression of UT Grain Noise Using SSP MPO Algorithms (SSP MPO 알고리즘을 이용한 초음파 결정립 잡음 억제에 관한 연구)

  • Koo, Kil-Mo;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.6
    • /
    • pp.81-89
    • /
    • 1996
  • It is very important for ultrasonic test method to evaluate the integrity of the class I components in nuclear power plants. However, as the rltrasonic test is affected by internal structures and configurations of test materials, backscattering, that is, time invariant noise is generated in large grain size materials. Due to the above reason, the received signal results in low signal to noise(S/N) ratio. Split spectrum processing(SSP) technique is effective to suppress the grain noise. The conventional SSP technique. however, has been applied to unique algorithm. This paper shows that MPO(minimization and polarity threshold) algorithm which two algorithms are applied simulatancously, was utilized, the signal processing time was shorten by using the new constant-Q SSP with the FIR filter which frequency to bandwidth ratio is constant and the optimum parameters were analysed for the signal processing to longitudinal wave and shear wave with the same requirements of inspection on nuclear power plant site. Moreover, the new ultrasonic test instrument, the reference block of the same product form and material specification, stainless stell test specimens and copper test specimens block of the same fabricated for the application of new SSP technique. As the result of experimental test with new ultrasonic test instrument and test specimens, the signal to noise ratio was improved by appying the new SSP technique.

  • PDF