Comparison of Improving Dewatering Process at Clay-Sandy Soil based on Pulse-Electrokinetic Technology and Continuous-Electrokinetic Technology (펄스동전기법과 연속처리동전기법을 이용한 점토성-사질토의 탈수화 효율 비교)

  • Shin, Sanghee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.4
    • /
    • pp.37-41
    • /
    • 2014
  • Pulse electrokinetic technology is proposed for improving the dewatering-process from clay-sandy soil. Proposed electrokinetic technology is to be the dewatering process due to fluid movement of current flow for the stability of clay-sandy soils. Samples produced in this study were completed to verify the proposed performance for 7 days by gradually increasing the pressure to the final pressure of 30 psi ($2.11kgf/cm^2$) through the compression process. In this study, pulse electrokinetic treatment and conventional continuous electrokinetic treatment are tested and observed, respectively. The condition of continuous electrokinetic treatment is a continuous process during 48 hours. And the condition of pulse electrokinetic treatment system is to interrupt the power three times for 48 hours, every 8 hours. These treatments are that the voltage gradient is 3 V/cm. As a result, the efficiency of pulse electrokinetic is similar to the continuous electrokinetic. The power consumption efficiency of pulse electrokinetic is better than continuous electrokinetic.

Dewatering of Sewage Sludge by Electrokinetics (동전기를 이용한 슬러지 탈수에 관한 연구)

  • Kim, Ji Tae;Won, Se Yeon;Cho, Won Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.661-667
    • /
    • 2006
  • In this study, an experiment of sewage sludge dewatering is carried by using electrokinetic method, and the electrokinetic dewatering efficiency of digested sludge is analyzed. Digested sludge without coagulants is selected and gravitational and pressing dewatering methods are applied in combination with electro-osmotic and electro-osmotic pulse technology. After the test of digested sludge, dewatering test of thickened sludge is carried to evaluate the electrokinetic dewatering feasibility of thickened sludge. Under the condition of constantly applied voltage, however, electrical resistance increases with decreasing of water content so that dewatering rate decreases with time. To reduce such a hindrance caused by constantly applied voltage, electro-osmotic pulse technology which is considered to reduce the difference of water content with height, is applied. For the application of electro-osmotic pulse, the dewatered flow rate and the dewatered volume became more increasing from the middle of the dewatering process than that of continuous voltage. Through the test of thickened sludge, electro-osmotic dewatering combined with gravitational and expression also showed high dewatering rate, which proved the possibility of using electrokinetic dewatering.

Dewatering Filtrate Treatment with Center Well Depth of Secondary Clarifier in Small Sewage Treatment Plant (소규모하수처리시설의 이차침전조 내통길이 변화를 통한 탈수여액의 처리)

  • Choi, Jung-Su;Kim, Hyun-Gu;Lee, Dong-Ho;Joo, Hyun-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.694-702
    • /
    • 2013
  • The purpose of this study is to evaluate a de-watering filtrate treatment and the possibility of securing biological treatment capacity by changing the structure of the secondary clarifier. Accordingly, the column test was conducted to determine the effect of polymer in the de-watering filtrate on sludge sedimentation. Also, the characteristics of de-watering filtrate processing was evaluated through batch test and continuous processing operation. The results showed that sludge settling velocity increased with higher polymer concentration, and that effluent SS concentration was found to decrease. Regarding processing characteristics of de-watering filtrate, the removal efficiency of TSS and TBOD5 increased as the length of secondary clarifier was longer. Also, comparing injections into anoxic tank and secondary clarifier, de-watering filtrate by continuous infusion treatment process showed stability in both conditions. Therefore, by modifying the structure of secondary clarifier, efficient processing of de-watering filtrate is expected to be possible and processing capacity of small sewage treatment plants is considered to be improved.

다중주파수 초음파처리를 이용한 하수슬러지의 탈수성 및 침강성의 변화에 관한 연구

  • Kim, Ju-Ho;Kim, Bu-Gil
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.11a
    • /
    • pp.385-389
    • /
    • 2006
  • 다중주파수 초음파를 이용한 하수슬러지의 전처리시 탈수성와 침강성에 관한 실험을 실시하여 다음과 같은 결론을 얻었다. 1. CST 변화량은 조사시간 80분까지 증가하다가 이후에는 감소하는 경향을 보여 탈수성이 개선될 수 있음을 보였다. 또한 삼중주파수가 이중주파수 일때보다 더 큰 영향을 끼쳤다. 2. $SV_{30}$의 변화량은 초음파 조사와 동시에 급격히 변화하여 침강성의 악화를 가져왔다. 또한 삼중주파수가 이중주파수 일때보다 침강속도를 더 빨리 악화시켰다. 3. 수온은 상승하였고, pH의 변화는 거의 일어나지 않았다. 본 실험에서 다중주파수를 사용하였을때, 단일주파수를 사용했을때보다 효율이 높았다. 그러나 다중주파수를 이용한 초음파 처리시 정확한 탈수성과 침강성 평가를 위해 ECP, 여과비저항(SRF), 입도분도, 점도 등 다양한 후속연구를 진행해야 할 것이다.

  • PDF

Effect of Microwave Irradiation and Chemical Conditioning for Dewatering Characteristics of Sludge (슬러지의 탈수 특성에 대한 마이크로파와 약품개량의 영향)

  • Park, Sang-Sook;Kang, Hwa-Young;Wang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.732-738
    • /
    • 2005
  • The purpose of this study is the presentation of the proper microwave treatment conditions by means of the investigation of the effect of microwave irradiation on the dewaterability and dryability of sludge. For the improving of dewatering efficiency of sludge using the microwave, the proper time of microwave irradiation is very important. The dewatering efficiency of thickening sludge conditioned by microwave irradiation for proper time was considerably improved with reducing of capillary suction time from 52.3 sec to 30.8 sec, and the sludge conditioned by microwave irradiation had contained the moisture of 81.4% after that pressure filtrationed. The result of drying characteristics of dewatered sludge using the microwave irradiation and furnace heating, for drying of sludge to moisture of below 55%, microwave irradiation time was required 3 min, whereas, furnace heating was required 40 min at $105^{\circ}C$, 20 min at $170^{\circ}C$ and 9 min at $300^{\circ}C$, respectively. We certified that the drying of dewatered sludge using the microwave irradiation was effectively reduction of moisture of sludge compare to traditional heating method.

Estimation of Anaerobic Co-digestion Efficiency of Dewatered Sludge and Food waste using Thermo-Chemical Pre-Treatment (열화학적 전처리에 따른 탈수슬러지 및 음식물류폐기물의 병합혐기소화 효율 평가)

  • Lee, Wonbae;Park, Seyong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.27-40
    • /
    • 2022
  • In this study, the anaerobic digestion potential and thermo-chemical pre-treatment were evaluated for efficient anaerobic co-digestion of dewatered sludge(DS) and food waste(FW). As a result, the degradable organic matter concentration and methane yield of FW were evaluated to 2.2 and 1.3 times higher than that of DS, respectively. In order to increase the amount of biogas production, it was determined that it is desirable to increase the mixing ratio of FW. The efficiency of thermo-chemical pre-treatment was evaluated for the reaction temperature, NaOH concentration, reaction time and mixture ratio. As a result of evaluation through pre-treatment efficiency and dehydration capacity, the optimum pre-treatment conditions were evaluated as follows: reaction temperature 140℃, NaOH concentration 60 meq/L, reaction time 60 min, mixture ratio 1:5(DS:FW). The gas production rate and methane yield increased 1.6 and 1.5 times, respectively, compared to before and after applying the optimum pre-treatment. Therefore, it is necessary to increase the mixing ratio of food waste for efficient anaerobic co-digestion of DS and FW. and it is necessary to increase the solubilization efficiency of waste by application of pre-treatment.

The Effect of Organic Acids on Dewatering Efficiency of Soybean Milk Residue by Hydraulic Press (유기산이 두유박의 압착 탈수율에 미치는 영향)

  • Pyun, Yu-Ryang;Cho, Won-Il;Lee, Yoon-Su;Kwon, Ick-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.638-643
    • /
    • 1996
  • The efficiency of dewatering of soybean milk residue was improved by hydraulic pressing after pH adjustment to 4.5 with organic acids such as acetic and lactic acids. Water content of raw soybean milk residue was reduced from 80% to 72% by pressing after pH adjustment, while only to 78% by the conventional hydraulic press. The water content of the residue after pH adjustment was further reduced to 63% by hydraulic pressing with ohmic heating. The pH adjustment facilitated separation of cake from the filter cloth and reduced the solid content of the expressed liquid from 10 to 3%.

  • PDF

Dehydration of Omija (Schisandra chinensis B.) using Red Algae Extract as a Hypertonic Agent (홍조류 추출물을 이용한 오미자의 탈수 및 건조)

  • Kim, Nam Ho;Jo, Wan Shin;Song, Kyung Bin
    • Food Science and Preservation
    • /
    • v.20 no.2
    • /
    • pp.284-288
    • /
    • 2013
  • Omija (Schizandra chinensis B.) slices were dehydrated with 20, 40, and 60% (w/w) red algae extract (RAE), and 40% of RAE was selected as the proper processing concentration considering the dehydration efficiency and cost of the dehydrating agent. The RAE-treated omija samples were compared with the hot-air dried samples in terms of the qualities such as the rehydration capacity and total phenolic contents. The rehydration ratios of the RAE-treated samples were greater than those of the hot-air dried samples by 31%. The total phenolic contents of the RAE-treated samples (1304.8 mg GAE/100 g) were higher than those of the hot-air dried samples (999.5 mg GAE/100 g). Therefore, omija slices can be dehydrated with RAE without quality loss.

A Study of Dewatering and Filtration on Woven Geotextile Tube (직포 지오텍스타일 튜브의 여과와 탈수에 대한 연구)

  • Kim, Tae-Hyung;Jung, Soo-Jung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.2
    • /
    • pp.31-37
    • /
    • 2006
  • The purposes of this paper are to study the use possibility of geotextile tubes for dewatering of high water content sludges and sediments and to evaluate affecting factors on dewatering. To do this, pressure filtration tests are conducted on four high water content materials with two geotextiles under two filtration pressures. Based on the test results, although woven geotextile tubes are not satisfied the soil retention criteria used in filter design commonly, a great portion of fines are retained by filter cake formation on geotextile tube's upstream side, but also after formation of filter cake, the permeability drops sharply. Higher filtration pressure tends to increase dewatering rate, but has very little effect on filtration efficiency. Dewatering capacity is affected by several factors which are related to the geotextile, but the property of sludge appears to be the dominant control factor for dewatering efficiency.

  • PDF

Electroosmotic Water Removal in Wet Porous Materials (다공성 흡수매체에 대한 정전삼투 탈수효과)

  • Park, Seon-Mi;Park, Mi-Jung;Ha, Ji-Soo;Chang, Hyuk-Sang
    • Clean Technology
    • /
    • v.16 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Various technical methods are applied for removing water from the water-retaining media, and the energy efficiency is the main concern in those methods. The electroosmotic process is studied as an efficient way for dewatering. An experimental electroosmotic reactor is designed and used for evaluating the effects of operational variables. The operational variables such as the electrical fields and the structure of water-retaining medias were studied. Three different shapes of polarized electric fields in ranges of 0-100 V/cm and 0-10 kHz are used as the source of electric voltage. The effect of electroosmotic process with respect to the structural variation is estimated by filling the electroosmotic reactor with the glass beads in 0.18 mm, 0.35 mm and 1.2 mm in diameters. 6% of water removal is obtained in the simulating electroosmotic reactor of glass beads. The estimated energy consumption in the simulating electroosmotic was 330~490 cal/g-water.