• Title/Summary/Keyword: 탄성초음파

Search Result 217, Processing Time 0.021 seconds

Effect of Bonding Layer on Guided Wave Mode Behavior in FRP Plate Bonded on Concrete (FRP 보강판 부착 콘크리트에서 유도초음파 모드 거동에 대한 접착층의 영향)

  • Lee, Yong-Ju;Shin, Sung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.34-40
    • /
    • 2012
  • In this study, effects of bonding agent, e.g. epoxy, on the behavior of fundamental guided wave modes propagated in FRP plate bonded on a concrete, are investigated. Global matrix model of multilayered FRP-epoxy-concrete system was constructed to obtain the velocity and attenuation dispersion curves of the fundamental A0 and S0 modes. Two variables, thickness and elastic modulus of epoxy layer, were considered in the dispersion analysis. It was found that both the thickness and the elastic modulus of epoxy layer greatly affect the phase velocity and attenuation of S0 mode while those are negligible for A0 mode. Based on the results, it was concluded that S0 mode is more effective than A0 mode for bonding condition assessment for FRP plate bonded concrete.

The analysis of tissue elasticity using computer-controlled ultrasonography in the affected upper limb of patients after breast cancer surgery

  • Chan-Hyuk Kwon;Min Woo Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.6
    • /
    • pp.167-173
    • /
    • 2024
  • In this paper, we propse a quantitative research by investigating the subcutaneous tissue elasticity by using ultrasonography in lymphedema patients after breast cancer surgery. Lymphedema patients who took breast cancer operation were included. Thickness of subcutaneous tissue was assessed at two spots; 10cm below elbow (forearm) and 10cm above elbow (upper arm), not only in affected side but also in sound side. By using probe attached to real-time pressure sensor, stress-strain curves were obtained. We defined tissue elasticity as slope of that curve at range of 7.5~15% of strain to avoid toe region. By comparing the elasticity of normal side and that of affected side, lymphedema tissues were classified into 'softer' and 'harder' tissues. Overall 30 cases of lymphedema tissues and 30 cases of sound tissues were checked. The difference of the elasticity between normal and affected side ranged from -3.98 N/m2 to 1.40 N/m2. The lymphedema tissues were classified into 17 softer tissues and 13 harder tissues. No demographic and clinical values, including clinical stage of lymphedema, showed statistically meaningful differences between two groups. Evaluation of subcutaneous tissue elasticity with ultrasonography and real-time pressure sensor could be one of the useful tools for investigation of lymphedema tissue characteristics.

New Design and Application of PVDF Ultrasonic Transducer for Measurement of Material Properties (재료물성 측정을 위한 직선집속 PVDF 초음파 트랜스듀서의 새로운 설계 및 응용)

  • Hong Soung-Wook;Kim Jung-Soon;Kim Sang-Yoon;Kim Moo-Joon;Ha Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.164-171
    • /
    • 2006
  • If the velocities of longitudinal, transverse and leaky surface acoustic waves in an isotropic material are given, the elastic constants and density of the material can be deduced analytically. Those velocities have been measured using three ultrasonic transducers with different vibrational modes so far. In this paper a line-focusing PVDF transducer with divided electrodes was newly proposed and designed for measuring approximate velocities of the three waves. The measurement method established in this study for each waves using the transducer was applied to several isotropic materials including fused quartz. The elastic stiffness constants and densities of the materials were calculated using the measured velocities, and the accuracies were discussed. It was shown that the obtained results are in good accord with the reference values.

A Study on Measurement of Penetration Depth of Steel Pipe Using the Impact-Echo Method (충격탄성파법에 의한 강관구조물 근입깊이 측정에 관한 연구)

  • Lee, Sang Hun;Kumagai, Takayuki;Endo, Takao;Han, Youn Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.89-89
    • /
    • 2011
  • 도로의 가드레일 지주 근입깊이의 부족에 의한 자동차의 전락사고 이 후, 일본의 국토교통성 등의 관계자들이 그 대책 세우기에 부심해 왔으나, 기설 지주의 근입깊이를 측정할 수 있는 방법은 아직까지 알려져 있지 않으며, 현재로서는 작업의 전 과정을 비디오로 촬영하여 그 기록을 남기도록 되어있다. 그러나 그것은 상당히 비효율적인 작업으로 엄밀한 감시기능을 다하지 못하고 있으며, 감독자와 시공자의 양자로부터 계측 도구의 개발이 절실히 요구되고 있다. 일부의 초음파 측정기 업자가 가드레일 지주의 근입깊이를 측정할 수 있다고 주장하고 있으나, 시장에는 아직 나타나지 않고 있으며, 그 측정시스템의 측정여부와 성능의 검증이 이루어지지 않고 있는 상황이다. 지금까지 충격탄성파법 또는 초음파법을 이용하여, 매설된 가드레일 지주의 근입깊이를 측정한 성공사례가 정식으로 보고된 바는 없으며, 같은 강관주인 눈사태 방지책의 지주 파이프에 대한 근입깊이의 측정은 본 연구그룹의 의해 행하여진 바가 있다. 검사봉이나 해머 등으로 대상물을 두드려서 탄성파를 발생시키고, 그것을 가속도계 또는 속도계의 진동센서로 감지하여 그 파형을 분석함으로써 대상물의 치수 등을 측정하는 충격탄성파법은, 특히 콘크리트를 대상으로 공동 및 매설물 등의 탐사, 균열깊이의 측정 등에 폭 넓게 사용되고 있다. 하지만 이 측정방법을 가드레일의 지주의 근입깊이 측정에 적용할 경우, 일반적으로 행하여지는 방법, 즉 진동센서를 대상물의 상단부(캡)에 설치하는 방법으로는 접합부에 의한 탄성파의 손실과 캡의 휨 진동에 의한 노이즈 등을 해결하기가 곤란해진다. 또한 지반의 존재로 인한 진동 모드의 변화와 진동에너지의 감소 등의 문제점을 해결하지 않으면 안 된다. 본 연구는 충격탄성파법을 이용하여 지반에 설치된 눈사태 방지책이나 가드레일의 지주와 같은 강관 구조물의 근입깊이를 측정하고자 하는 연구이다. 이를 위해 진동센서를 캡이 아닌 측면부에 취부장치를 이용하여 설치함으로써 길이방향의 탄성파를 측정할 수 있도록 하고, 실제 구조물에 대해 측정을 실시하여 그 측정시스템의 성능과 유용성을 검토하고자 한다. 또한 다양한 길이의 실험용 강관 파이프를 매설하고 측정실험을 실시하여 측정시스템의 적용성에 대해서도 검토하였다. 본 연구를 통하여, 수신센서를 파이프의 측면에 선접촉하게 함으로서 종파를 감지하여 근입깊이를 포함한 파이프의 전 길이를 측정하는 본 측정시스템은 매설된 강관 구조물의 길이 측정에 기본적으로 적용 가능함을 확인할 수 있었다. 특히 오거 굴착으로 시공된 경우에는 높은 정도의 측정성능을 보여주었다. 또한 항타관입 파이프에 대해서는 지반의 영향을 고려함으로써 길이의 측정이 가능하다는 것을 확인할 수 있었다. 즉, 오거 굴착 또는 항타 관입 등 시공방법에 따라 측정결과에 대한 지반의 영향 정도가 달라지며 파형 분석 및 길이 산정시 그 영향을 고려하여야 함을 확인하였다.

  • PDF

Non-Destructive Evaluation of Microstructure of SiC/AC8A Composite Material by Ultrasonic Measurement (초음파를 이용한 비파괴방법에 의한 SiC/AC8A금속 복합재료의 미시조직 평가)

  • Park, Y.C.;Yun, D.P.;Lee, G.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.4
    • /
    • pp.225-233
    • /
    • 1997
  • This study is performed to establish a non-destructive evaluation method for metal matrix composite using ultrasonic technique. The specimen is made of SiC/AC8A metal matrix composite by squeeze-casting method. Three kinds or reinforced particles are prepared as 4.86, 8.09 and $11.44{\mu}m$ to investigate the effect of size on the mechanical and ultrasonic properties of metal matrix composite. In addition, four different volume fractions (14, 22.5, 27.5, 35%) of reinforced particles are prepared per each size to examine the effect of volume fraction on the ultrasonic properties. From this specimen, the availability and precision of measurement of Young's modulus are examined and the evaluation method for microstructure of metar matrix composite using the speed of sound and attenuation factor is also reviewed. The results show that the Young's modulus measured by ultrasonic method is as effective as that measured by mechanical method. It is also known that the size and volume fraction of reinforced fiber are precisely evaluated using the speed of sound and attenuation factor.

  • PDF

Evaluation of High Attenuation Material Using Utrasonic Wave Analysis (초음파의 파형 해석에 의한 고감쇠 재료의 평가)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.364-370
    • /
    • 1995
  • The purpose of this paper was to develop a nondestructive evaluation method of sintered material by ultrasonic method. The density distribution of sintered material becomes inhomogeneous partially because of the friction between the powder and the die during compaction. The inhomogeneity was investigated by measurement of the energy attenuation coefficient and the shift of the center frequency in the frequency spectrum of the ultrasonic reflection echo. The experimental results showed that the center frequency of reflection wave depended linearly on the density of sintered materials. However, the attenuation coefficient decreased inversely as the density increased. This study shows that the shift of the center frequency in the frequency spectrum of reflection wave can be used to a nondestructive evaluation of sintered materials.

  • PDF

Elasticity and Viscosity Control of an Ultrasonic Motor by a Phase Difference Control (초음파 모터의 위상차 조절에 의한 점탄성 제어)

  • 우수용;이권현;오금곤;정헌상;김영동
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.5
    • /
    • pp.86-92
    • /
    • 1997
  • An ultrasonic motor(USM) has good characteristics such as compact size, silent motion, high speed responce, low speed and high torque. The USM is driven by 2-phase AC electricity. The control parameters of USM are voltage, phase, and frequency of input powers, etc. In this paper, the fine elasticity and viscosity control with no force feedback can be implemented by a phase difference parameter. Experiment results show the change of torque with regard to elasticity and viscosity. Therefore the USM can be used as a micro-actuator in the automation field of the installation.

  • PDF

Fabrication of PVDF Line Focus Ultrasonic Transducer and its Application I. Fabrication and Characteristics Evaluation (직선집속 PVDF 초음파트랜스듀서의 제작과 응용 I. 제작 및 특성평가)

  • Yoon Hyuck-joon;Ha Kang-Iyeol;Kim Moo-joon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.387-390
    • /
    • 1999
  • 누설탄성표면파(Leaky Surface Acoustic Wave : LSAW) 측정에 사용하는 것을 목적으로 PVBF 압전막을 이용하여 직선집속 초음파트랜스듀서를 제작하고 그 특성을 평가하였다. 제작은 한쪽 면이 원통형 구조를 갖는 구리, 알루미늄, 3mmPVC-에폭시 3가지 재료를 배면층으로 사용하여 각각에 PVDF를 부착시켜서 수중에 음파를 방사하도록 구성하였고, 특성평가는 임펄스응답 특성과 음장 특성으로 나누어서 평가하였다. 임펄스응답 특성은 제작한 3종류의 집속 초음파트랜스듀서에 대해 실험적으로 측정하고, Mason 등가회로1)를 이용한 이론적 해석결과와 비교하였다. 음장특성 측정실험은 구리를 배면체로 하여 제작한 집속 초음파트랜스듀서에 대해서 실시하였고, 그 이론적인 계산결과는 Raylelgh-Somme-rfeld 회 절이론2)을 도입하여 초점면에 형성되는 음압분포를 계산하는 것으로 얻어졌다. 실험은 펄스 초음파 송수기 및 $2{\mu}m/step$으로 이동하는 정밀 x-y-z 스테이지를 컴퓨터에 연결하여 자동 측정하는 것으로 수행되었는데, 그 결과는 이론 해석결과와 비교적 잘 일치하였다.

  • PDF

Analysis of Image for Liver Disease using Blood Test in the Ultrasound Fibroscan (Fibroscan에서의 혈액검사를 이용한 간질환의 영상분석)

  • Lee, Jeong-Hyun;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.8
    • /
    • pp.389-396
    • /
    • 2015
  • The liver fibrosis is a disease we often see in clinical medicine, and the persistence and repeatition of inflammation and necrosis of liver cells continue for several years, and it is proceeded to cirrhosis. So decrease of death rate and prevalence rate by complications of cirrhosis and hepatocellular carcinoma is main task of clinical medicine by protection of chronic liver ailment patients from proceeding to cirrhosis and hepatocellular carcinoma. So this study tried to represent the ultrasonic image, blood test, the relationship with liver stiffness of diffuse liver ailment patients as numbers. This study was performed with patients from whom the image was taken by ultrasonic and 141 people who were treated by fibroscan, the basic data for blood test was obtained from the test results at the time when ultrasonic image and liver fibroscan was performed. The statistical analysis was performed by One-way analysis of variance(ANOVA) to verify difference between groups. The value of liver stiffness was increased in the order of normal, chronic liver disease and cirrhosis. As a results, ALT and Albumin have no statistical difference between object groups, and there are statistical differences in the results of ultrasonic decoding at age, AST, ALP, Bilirubin, PLT, PT, and kPa, and they are statistically meaningful(p<0.005). And the value of liver stiffness of chronic liver ailment was presented only as over 12.5kPa in other study, but it was represented as numbers for quantitative diagnosis by presenting average kPa threshold value according to disease in this study. And by presenting relationship of diagnosed results, it is considered that it could be used as first tool to diagnose chronic liver ailment patients according to their disease.

The Interaction Between Stress Waves in Elastic Solids for an Ultrasonic Viscometer and Adjacent Viscous Fluids (초음파 점도계용 고체 매질의 탄성파와 인접 점성유체 간의 상호작용)

  • 김진오
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.28-34
    • /
    • 1999
  • The effects of the viscosity of an adjacent viscous fluid on the characteristics of the elastic waves have been studied theoretically and experimentally. Expressions for the wave speed and attenuation of the elastic waves of transverse motion, such as the torsional wave propagating in a circular cylinder and the Love wave in a layered half-space solid, have been obtained as functions of the viscosity and mass density of the fluid by exact and asymptotic analyses. The theoretical results have been compared with experimental observations, and it has been demonstrated that a device described herein can be used as a sensor for measuring the viscosity of a fluid with a known mass density.

  • PDF