• Title/Summary/Keyword: 타각

Search Result 137, Processing Time 0.026 seconds

Research of Difference between the Refractive Powers by Autorefractometer and the Prescription using Phoropter (자동 굴절력계의 굴절력값과 포롭터를 이용한 처방값의 차이에 관한 연구)

  • Lee, Ju-Whan;Lee, Koo-Seok;Hong, Hyung-Ki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study is research of the conditions which causes difference between the refractive power of the measurement of autorefractometer and the prescription using phoropter. Methods: Autorefractometer (SR-7000) and phoroptor (AV-9000) were used to measure 60 eyes of 30 participants who had no eye diseases and wore the corrective lens due to Ametropia. To prevent the dependence of the prescription value of the refractive power on the testers, two testers measured the refractive power of the eyes of the participants at the same measuring conditions. Results: Statistically, the prescribed values of the refractive power by two testers were not significantly different. Most of the prescribed values of the refractive power were smaller than the refractive power by autorefractometer In case of myopic eyes, the difference between refractive powers by the measurement of autorefractometer and the prescription using phoropter showed the trend of increase as the spherical refractive power became larger. The result was analyzed by the range of the different cylindrical refractive power for the myopic astigmatic eyes. In this case, the difference between refractive powers showed the trend of decrease as the cylindrical refractive power became larger. Conclusions: No difference between the prescribed value by two testers was observed. In case of myopic or myopic astigmatic eyes, the difference between refractive powers by autorefractometer and the prescription were measured to be approximately proportional to the refractive powers of ametropic eyes. As the this difference become larger for the participant who needs the lens of larger refractive power, additional caution is needed in the prescription of the refractive power of the corrective lens.

A Comparative Analysis of increased along with the age presbyopic additions in city and island villages (도시와 섬마을 노안의 연령에 따른 근용 가입도의 비교 관찰)

  • Kim, In-Suk;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.61-65
    • /
    • 2002
  • This study examines how the average presbyopic additions and eye refraction state of old ages in city may be different to that island. There were 677 of the old who were 50 or over 90 in the sample. The visual acuity test was done by objective and subjective methods and used for near-chart program. The far-point refraction state and power of the additions lens results were as follows ; 1. Of far-point refraction state in city peoples; male: emmetropia 10%, myopia 17%, hyperopia 19%, mixed astigmatism 38%, etc. 16% female : emmetropia 20%, myopia 20%, hyperopia 20%, mixed astigmatism 27%, etc. 13% 2. Of far-point refraction state in island villages ; male : emmetropia 13%, myopia 17%, hyperopia 22%, mixed astigmatism 40%, etc. 8% female : emmetropia 7%, myopia 13%, hyperopia 26%, mixed astigmatism 44%, etc. 10% 3. Average presbyopic additions states has been presented no discrimination ; male: 50 to 60 : +1.25 or +1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.75 or +3.00D, 76 to 80 : +3.25 or +3.50D, over81 : +3.75D female : 50 to 60 : +1.25 or + 1.50D, 61 to 65 : +1.75 or + 2.00D, 66 to 70 : +2.25 or +2.50D 71 to 75 : +2.25 or + 2.50D, 76 to 80 : +2.75 or +3.00D, over81 : +2.75 or +3.00D 4. Under the condition of wearing lens, the average working time was 1 or 2 hour but some people used over 5 hours. 5. Generally, it has been investigated the old ages peoples has ocular diseases and cataract was the most common.

  • PDF

A Study on the Ametropia of High School Students in Jeonbuk Province (전북 지역 고등학생 비정시에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun;Choe, Oh-Mok;Gang, Myoung-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.67-71
    • /
    • 2002
  • To investigate the ametropia and refractive error of 364 ametropic eyes en the 182 high school students in Jeonbuk provicne, the visual acuity test was performed by the object and subject method. The results were as follows. 1. The eye types were 85.7% positive for myopia, 6.6% for emmetropia and 7.6% hyperopia, respectively. 2. The abnormal refraction eyes were 30.8% positive for simple myopia, 58.5% for myopia compound astigmatism, 7.5% for myopia simple astigmatism, and 1.8% for simple hyperopia, 1.3% for hyperopia compound astigmatism, 1.9% for hyperopia simple astigmatism, respectively. 3. The axes of astigmatism were 78.7% for astigmatism with-the-rule, 13.9% for astigmatism against-the-rule, 7.4% for astigmatism oblique, respectively. 4. As for the astigmatic power, the 0.50 < cylinder < 1.00dptr was 60.0%, the 1.00 < cylinder < 2.00dptr was 29.2%, and anything over the 2.00cylinder dptr was 10.8%. 5. As for the equivalent spheric power of myopic abnormal refraction eyes, the -0.50 < spheric equivalent < -2.00 diopter was 64.6%, the -2.00 < spheric equivalent < -6.00 dptr was 29.1% and anything over the -6.00 dptr was 6%. 6. The equivalent spheric power of hyperopic abnormal refraction eyes was 50% anything under 2.00diopter and 50% for anything over the 2.00diopter.

  • PDF

Ship s Maneuvering and Winch Control System with Voice Instruction Based Learning (음성지시에 의한 선박 조종 및 윈치 제어 시스템)

  • Seo, Ki-Yeol;Park, Gyei-Kark
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.6
    • /
    • pp.517-523
    • /
    • 2002
  • In this paper, we propose system that apply VIBL method to add speech recognition to LIBL method based on human s studying method to use natural language to steering system of ship, MERCS and winch appliances and use VIBL method to alternate process that linguistic instruction such as officer s steering instruction is achieved via ableman and control steering gear, MERCS and winch appliances. By specific method of study, ableman s suitable steering manufacturing model embodies intelligent steering gear controlling system that embody and language direction base studying method to present proper meaning element and evaluation rule to steering system of ship apply and respond more efficiently on voice instruction of commander using fuzzy inference rule. Also we embody system that recognize voice direction of commander and control MERCS and winch appliances. We embodied steering manufacturing model based on ableman s experience and presented rudder angle for intelligent steering system, compass bearing arrival time, evaluation rule to propose meaning element of stationary state and correct steerman manufacturing model rule using technique to recognize voice instruction of commander and change to text and fuzzy inference. Also we apply VIBL method to speech recognition ship control simulator and confirmed the effectiveness.

Evaluation of scale accuracy and effect of off-the-visual-axis on schematic retinoscope training eye (검영기 훈련 모형안의 굴절상태 눈금과 벗어난 시축의 평가)

  • Ryu, Dong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3789-3793
    • /
    • 2010
  • To investigate accuracy of graduated scale of schematic retinoscope training eye(schematic eye) and induced effect when measured at off-axis from visual axis. Two skilled retinoscopist measured refractive power using retinoscope in random order. Seven schematic eyes from a single manufacturer were recruited and set to mark +4.00 to -6 diopter(+4, +3, +2, +1, 0, -1, -2, -3, -4, -5, -6). After introducing +2.00 diopter trial lens(50cm working lens), neutral distance was measured at 180 degree to estimate accuracy of scale, and refractive power measured at 0, 5, 10, 15 and 20 degree off-axis to see if any error was induced. According to the results measured by two specialists, in six of seven schematic eye, scale setting varied (p<0.05) and measured refractive power at 5, 10, 15 and 20 degree off-axis from visual axis were $-0.13{\pm}0.06$, $-0.29{\pm}0.06$, $-0.58{\pm}0.11$, and $-0.83{\pm}0.16$ diopter respectively. In some schematic eye, scale graduated on the schematic eye and scale measured by retinoscopy could be different and if retinoscopy is performed off-axis from visual axis, any measuring error can be caused.

The Study on Hansen's Disease of Ametropia (나환자들의 비정시에 대한 고찰)

  • Lee, Hark Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.145-150
    • /
    • 1998
  • To 160 persons(90 men, 70 women) who went to the national hospital of Solok-island with Hansens's disease, I tested the objective refracts test with the product of Cannon Ltd. Co. which RK-3 Auto Ref-keratometer's auto ophthalmoscope. The results were like these. Visual acuity of above 0.7 that can live without glasses was contained 44 men's eyes(24.4%) and 19 women s eyes(13.6%). These result are indicated that men have had more good visual acuity than women. Visual acuity of below 0.6 that cannot do normal life was contained 80.3% of the total patients. And amblyopia of below 0.3 and eyes which cannot be corrected were shown 44.4%(80 men's eyes and 55.7% 78 woman's eyes). Myopia was contained 119 eyes(43), hyperopia was contained 139 eyes (50.4%) and emmetropia was 6.5%. Astigmatism was shown 136 men s eyes (86.6%) and 97 women's eyes(81.5%). These results are indicated what many people accompany with astigmatism. And these ratio had some high percentages men rather than women. Direct astigmatic was contained 37 eyes (11.6%), Indirect astigmatic 81 eyes(25.3%) and Oblique Astigmatic 115 eyes(35.9%). As a of distributed result oblique astigmatic occupied best high point as 49.4% in 233 astigmatism and distributed the opposite direction as compared with normal irregular emmetropia not patient.

  • PDF

A study of refraction state of middle aged & manhood in Daegu (대구지역 중·장년층의 굴절상태 연구)

  • Choi, Gei-Hun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.323-332
    • /
    • 2004
  • This study researched the visual acuity test object and Auto-refractormeter, visual of near power. The object were composed of middle aged, the old men and women who in habit Daegu. The results were as follows : 1. The subjects consisted of 537 people, 29.98% men, 70.02% women. 2. The emmetropia was 1.12% for myopia, 2.79% for hyperopia, 96.09% for astigmatism. 3. The abnormal refraction was composition for myopic compound astigmatism(16.57%), hyperopia compound astigmatism(45.62%), Mixed astigmatism(33.89%). 4. On the Myopic Spherical Equivalent(S.E) power, the range of -0.50D ${\leq}$ M.S.E < -1.00D was 21.67%, -1.00D ${\leq}$ M.S.E < -2.00D was 48.89%, -2.00D ${\leq}$ M.S.E < -6.00D was 29.44%. 5. On the Hyperopic Spherical Equivalent(S.E) power, the range of +0.50D ${\leq}$ H.S.E < +1.00D was 28.57%, +1.00D ${\leq}$ H.S.E < +2.00D was 49.30%, +2.00D ${\leq}$ H.S.E < +6.00D was 23.13%. 6. The addition power was 1.00D(8.01%), 1.50D(8.57%), 2.00D(13.78%), 2.50D(16.57%), 3.00D(16.95%), 3.50D(17.88%), 4.00D(18.25%).

  • PDF

Relationship on the Refractive Status of the High School 3rd Grade Students with Subnormal Visual Acuity in Gwangju Metropolitan City (광주지역 고등학교 3학년생의 비정시안의 굴절상태에 대한 고찰)

  • Yoon, Young;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • To investigate the ametropia and refractive error of 222 ametropic eyes of the 111 high school students in Gwangju Metropolitan City, the visual acuity test was performed by the object and subject method. 85% of the eye types were positive for myopia, 14% for emmetropia, and 1% for hyperopia, respectively. 38% of the abnormal refraction eyes were positive for simple myopia, 4% for myopia simple astigmatism, 56% for myopia compound astigmatism, and 0% for simple hyperopia, 0% for hyperopia simple astigmatism, 2% for hyperopia compound astigmatism, 0% for mixed astigmatism, respectively. 92% of the axes fo astigmatism were for astigmatism with-the-rule, 6% for astigmatism against-the rule, 2% for astigmatism oblique, respectively. As for the astigmatic power, 0.50 < cylinder < 1.00D was 68%, 1.00 < cylinder < 2.00D was 25%, and anything over the 2.00 cylinder D was 7%. As for the equivalent spheric power of myopic abnormal refraction eyes, -0.50 < spheric equivalent < -2.00D was 26%, -2.00D < spheric equivalent < -6.00D was 55% and anything over the -6.00D was 19%. The rate of wearing glasses was 74%. It increases compared to 20 years ago. 91% of the eye test place was the optical shop, 9% the eye doctor hospital. 80% of the students need to change their optical lenses because spherical equivalent power was over 0.50D.

  • PDF

The Study on Effects of After Vision Training for Elementary School Children in Muan (무안군 소재 초등학생들의 시훈련 효과에 관한 연구)

  • Jang, Jung Un;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.137-142
    • /
    • 2013
  • Purpose: This study was designed to investigate the current status of visual acuity for elementary school students in Muan-gun and to analyze improvements of their visual function after vision training for the elementary school students who have either insufficiency of accommodation or vergence. Methods: Subjective refraction, objective refraction and binocular function were examined for 335 elementary school children from year 1 to year 6 live in Muan area, and then 47 students who have symptoms of binocular dysfunction among them were selected. We analyzed and compared between before and after vision training (VT) in binocular vision function results. Results: The results show that most of the subjects had much problem in near point convergence (NPC) than accommodation. After the vision training, the average of subjects NPC was improved about 5.93 cm, from $11.57 {\pm}1.850$ cm for before VT to $5.66{\pm}0.965$ cm for after VT. After VT positive fusional vergence at near distance after VT was $19.64{\pm}3.66$ $\Delta$, which was as much as double of near phoria. Accommodative amplitude was improved from $10.02{\pm}2.566$ D for before VT to $12.30{\pm}1.397$ D for after VT, which similar to mean of expected accommodative amplitude of 11.27 years old. Conclusions: Among insufficiency of accommodation and vergence NPC was improved specially, and accommodative facility and other ocular functions were also improved. Therefore, it is considered the vision training is very effective to recover from visual function problems.

The Refractive Error Eye of the Korean Male Adult (한국인 성인 남성의 굴절이상)

  • Shin, Young-Soo;Kim, Douk-Hoon;Mun, Jung-Hak
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.77-82
    • /
    • 1999
  • To have a fine understand the refractive error eye of Korean adult male, This study was researched visual acuity test using objuctive and subjective methods. The results are as follows: 1. The eye types were 93.3% positive for myopia, 5.4% for emmetropia, and 1.7 forhyperopia, respectively. 2. The refractive error eye was positive for compound myoptic astigmatism for a percntage of 62.6%, simple myopia(32.4%), simple myoptic astigmatism(1.6%), simple hyperopia(l.4%) simple hyperopia astigmatism(0.5%), and mixed astigmatism(1.6%). 3. The axis of astigmatism was 59.7% for regular astigmatism, 25.3% for oblique astigmatism, and 15% for reverse regular astigmatism, respectively. 4. on the total myoptic spheric power, the -2.00

  • PDF