• Title/Summary/Keyword: 큰 변위

Search Result 777, Processing Time 0.044 seconds

Behavior Analysis of Concrete Structure under Blast Loading : (II) Blast Loading Response of Ultra High Strength Concrete and Reactive Powder Concrete Slabs (폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (II) 초고강도 콘크리트 및 RPC 슬래브의 실험결과)

  • Yi, Na Hyun;Kim, Sung Bae;Kim, Jang-Ho Jay;Cho, Yun Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.565-575
    • /
    • 2009
  • In recent years, there have been numerous explosion-related accidents due to military and terrorist activities. Such incidents caused not only damages to structures but also human casualties, especially in urban areas. To protect structures and save human lives against explosion accidents, better understanding of the explosion effect on structures is needed. In an explosion, the blast load is applied to concrete structures as an impulsive load of extremely short duration with very high pressure and heat. Generally, concrete is known to have a relatively high blast resistance compared to other construction materials. However, normal strength concrete structures require higher strength to improve their resistance against impact and blast loads. Therefore, a new material with high-energy absorption capacity and high resistance to damage is needed for blast resistance design. Recently, Ultra High Strength Concrete(UHSC) and Reactive Powder Concrete(RPC) have been actively developed to significantly improve concrete strength. UHSC and RPC, can improve concrete strength, reduce member size and weight, and improve workability. High strength concrete are used to improve earthquake resistance and increase height and bridge span. Also, UHSC and RPC, can be implemented for blast resistance design of infrastructure susceptible to terror or impact such as 9.11 terror attack. Therefore, in this study, the blast tests are performed to investigate the behavior of UHSC and RPC slabs under blast loading. Blast wave characteristics including incident and reflected pressures as well as maximum and residual displacements and strains in steel and concrete surface are measured. Also, blast damages and failure modes were recorded for each specimen. From these tests, UHSC and RPC have shown to better blast explosions resistance compare to normal strength concrete.

Dental Management of Pediatric Hydrocephalus (소아 수두증 환자의 치과적 관리)

  • Kim, Mijun;Park, Howon;Lee, Juhyun;Seo, Hyunwoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.228-234
    • /
    • 2017
  • Hydrocephalus is a condition in which the volume of cerebrospinal fluid in the cerebral ventricles is abnormally elevated. Hydrocephalus patients may show macrocephaly and delayed development. Ventriculoperitoneal shunt is the most commonly used treatment but ventriculoatrial shunt is another treatment option. This report discusses the dental management process employed for a 7-year, 6-month old patient with ventriculoperitoneal shunt-treated hydrocephalus. This patient showed dental caries on the deciduous molars, facial swelling, macrocephaly and delayed development. Pulpectomy was performed on the deciduous molars under nitrous oxide sedation and mild protective stabilization. This patient did not appear to have any specific complications until the latest follow-up and was scheduled for the management of overall oral hygiene, development of permanent teeth, and craniofacial asymmetry through periodic follow-up. During dental treatment of shunt-treated patients, care should be taken to avoid applying excessive force to the catheter running along the patient's neck to prevent the displacement of the catheter. A referral to a neurosurgeon is recommended for patients with ventriculoatrial shunts for prophylactic antibiotics. As hydrocephalus patients grow, they may show craniofacial asymmetry or differences in the calcification of the permanent teeth, and require periodic oral and craniofacial assessment.

Seismic Performance of Bridges with the Modeling of Expansion Rocker Bearings (라커베어링 모델에 따른 교량의 지진거동)

  • Choi, Eunsoo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.755-763
    • /
    • 2002
  • Multispan simply supported bridges and multispan continuous bridges take a large portion of bridges in Central and Southeastern United Sates. The superstructure of the bridges are supported by steel rocker bearings. In general, the rocker bearings are modeled with ideal rollers or Coulomb fricition in seismic analysis. However, the rocker bearings have rocking action on pintles after rolling some distance. This rocking action may have considerable effect on the seismic performance of bridges. This study compares the effect of expansion rocker bearings models on a multispan simply supported and a multispan continuous bridge. Since the ideal roller model produces larger responses than the rocking model, its use is undesirable. However, the fricition and hardening model does not have much difference from the responses of the rocking model. In addition, the use of the tow models is convenient in seismic analyses of bridges. Although the rocking model can obtain more exact responses, its behavior is complicated and it may induce the conversion problem in time history analysis because it includes the abrupt changing of stiffiness. The friction and hardening model of expansion rocker bearings is therefore recommended in sesismic analysis.

A Study of Meshless Method Programming (무요소법 프로그래밍에 관한 연구)

  • 김학수;배동명
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.2
    • /
    • pp.110-118
    • /
    • 2002
  • The element free Galerkin method has been suggested by Belyschko, etc. it is applied for linear elastic analysis of solid problems and its convergence characteristics and stability are shown according to the weight function, influence domain and scattered points. The various numerical examples are performed to check the efficiency of 1D EFG and 2D EFG program by changing factors. As a result it have the best results when it used the cubic spline weight function and the scaling parameter d$_{max}$=2. These programs were developed by mixed language programming method using Visual Basic and the C language. so it is fast and efficient. and visually shown the result.t.

Analysis of pile load distribution and ground behaviour depending on vertical offset between pile tip and tunnel crown in sand through laboratory model test (실내모형시험을 통한 사질토 지반에서 군말뚝과 터널의 수직 이격거리에 따른 하중분포 및 지반거동 분석)

  • Oh, Dong-Wook;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.355-373
    • /
    • 2017
  • Tunnelling in urban areas, it is essential to understand existing structure-tunnel interactive behavior. Serviced structures in the city are supported by pile foundation, since they are certainly effected due to tunnelling. In this research, thus, pile load distribution and ground behavior due to tunnelling below grouped pile were investigated using laboratory model test. Grouped pile foundations were considered as 2, 3 row pile and offsets (between pile tip and tunnel crown: 0.5D, 1.0D and 1.5D for generalization to tunnel diameter, D means tunnel diameter). Soil in the tank for laboratory model test was formed by loose sand (relative density: Dr = 30%) and strain gauges were attached to the pile inner shaft to estimate distribution of axial force. Also, settlements of grouped pile and adjacent ground surface depending on the offsets were measured by LVDT and dial gauge, respectively. Tunnelling-induced deformation of underground was measured by close range photogrammetric technique. Numerical analysis was conducted to analyze and compare with results from laboratory model test and close range photogrammetry. For expression of tunnel excavation, the concept of volume loss was applied in this study, it was 1.5%. As a result from this study, far offset, the smaller reduction of pile axial load and was appeared trend of settlement was similar among them. Particulary, ratio of pile load and settlement reduction were larger when the offset is from 0.5D to 1.0D than from 1.0D to 1.5D.

Uplift Capacity of Spiral Bar through the Model Experiment (모형실험을 통한 스파이럴 기초의 인발저항력 검토)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Ha Neul;Lee, Si Young;Kang, Dong Hyeon;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.202-209
    • /
    • 2015
  • This study compared and analyzed the measurements of pullout load according to the depth of reclamation in the foundation, compaction ratio of soil, spiral diameter, and soil textures in an experiment with a model and reached the following conclusions: The comparison results of extreme pullout load between farm and reclaimed soil show that farmland soil recorded a score that was 1.2~3 times higher than that of reclaimed soil. The investigator measured pullout load in farmland and reclaimed soil and observed a tendency of rising extreme pullout load according to the increasing depth of reclamation and compaction ratio with a similar load-displacement curve between the two types of soil. Extreme pullout load made a greater increase by the rising size of diameter than the increasing depth of reclamation, also making a considerably bigger increase according to the rising compaction ratio than the other conditions. Therefore, the spirals bar is expected to be available in soft soil foundation, as well as farmland as increasing buried deep of foundations, compaction rate, diameter of the spiral, ect.

Behavior Analysis of Approach Slabs of IPM Bridges according to Unsupported Length and Settlement (토압분리형 교량 접속슬래브의 비지지길이와 지반 침하에 따른 거동 해석)

  • Park, Min-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.650-660
    • /
    • 2018
  • The approach slab plays an important role in the driving comfort of the connection section on a bridge. On the other hand, the approach slab only calculates the section force of a simple beam, and does not analyze the behavior. In this study, the unsupported length and settlement of approach slabs of IPM Bridges were examined using structural analysis. First, the section force was calculated by designing a simple beam, according to the length of the approach slab. The structural analysis was conducted to examine the behavior of the unsupported length and settlement. As the result, the bending moment decreased when the unsupported length was increased, and the bending moment increased when the settlement was increased. In addition, the design section force was estimated to be larger than the force of structural analysis, and the design of the approach slab according to the design guideline showed no problem in stability. Nevertheless, the vertical displacement exceeded the maintenance criterion of a 1/200 curve when the settlement exceeded 10 mm regardless of the unsupported length. Therefore, excessive settlement occurs in the reinforced earth retaining wall supporting the approach slab, and the design bending moment may be exceeded. Therefore, strict management is required.

Analysis & Design Electronic Commerce System Interface for The Blind (시각장애 사용자를 위한 전자상거래 인터페이스 분석 및 설계)

  • 박성제;강영무
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2001.12a
    • /
    • pp.413-426
    • /
    • 2001
  • 본 연구는 첫째, 정보통신기술의 발달이 시각장애인 복지 증진에 미칠 수 있는 가능성에 대한 이론적인 부분을 고찰하였다. 둘째, 우리나라 시각장애인 정보화의 문제점과 해결책을 도출하였고 셋째, 시각장애 사용자를 위한 전자상거래 인터페이스 디자인의 분석 및 설계를 통해 전자상거래에서 시각장애 사용자들이 큰 제약없이 사용할 수 있는 방안을 제시하고자 한다. 현재 시각장애인들의 웹 사용을 보면 시각장애 전용 S/W의 보조 하에 사용을 하고 있다. 그러한 보조 도구의 실정에 맞도록 텍스트 버전 및 Non-Frame버전, Alt-Text 옵션, 캡션 등을 넣어 접근성을 확보하고 인터넷을 큰 제약을 받지않고 이용할 수 있도록 웹 페이지의 설계가 필요한 실정이다. 이를 위하여 먼저 시각장애에 대한 개념과 원인 및 종류 그리고 특성을 통해 시각장애인에 대한 이론적 배경을 파악하였다. 그리고 시각장애인의 정보화 환경과 이용 현황과 시각장애인의 정보 접근을 제도적, 기기 및 소프트웨어 개발 측면에서 분석을 하였고, 장애인을 위한 정보통신기술 중 대표적인 사례를 검토해 보았다. 다음으로 국내외의 대표적인 전자상거래 사이트에서의 인터페이스를 화면구성(Layout), 텍스트(Text), 그래픽(Graphic), 멀티미디어(MultiMedia) 측면에서 분석을 하였다. 분석한 내용을 바탕으로 시각장애 사용자의 입력(User Input) 부분을 고려한 인터페이스 방향을 제시하고 프로토타입을 개발하여 시험 대상 사이트와의 만족도를 시각장애 사용자를 통해 비교 ·분석하였다. 결론부분에서는 정보불평등을 해소하고, 정보통신기술이 장애인의 복지향상에 기여하도록 하기 위해 전자상거래 싸이트에서의 시각 장애인들을 위한 방향을 제시하고자 한다.박의 표현, 등록 및 색인방법 (c) 공급 선박의 분류와 표현 방법 (d) 에이전트의 정보 수집을 위한 메시지 표현 방법 (e) 수집된 선박정보의 데이터베이스 저장 표현방법 (f) 요구 선박을 찾아주는 정보제공 서비스가 요구된다.동을 보여 조사대상 5호분, 6호분, 7호분, 중 가장 심한 거동을 보이고 있다. 이는 고분 벽돌의 깨짐이 6호분이 가장 심하다는 사실과 무관하지 않은 것으로 판단된다. 봉분내부의 토양층구조에 대한 지오레이다 영상단면을 분석한 결과 무령왕릉 연도상부의 누수지방지층이 심하게 균열되어 있음을 발견하였다. 이 곳은 고분내부로 직접누수가 발생하는 곳이다. 직접누수와 지하수 형태로 유입된 침투수는 고분군 주위의 지반의 함수비를 증가시켜 지반의 지지력을 약화시키고 또한 고분내로 서서히 유입되어 고분내부의 습도를 100%로 유지시키는 주된 원인이다. 이러한 높은 습도는 고분내의 남조류의 번식을 가져왔으며 남조류의 번식은 현재 6호분이 가장 심각하고 7호분이 우려되는 수준이며 5호분은 문제가 없는 것으로 판단된다. 이와 같이 고분군의 발굴후 인위적인 환경변화와 지속적인 강우침투 및 배수 불량의 영향은 고분군의 안정성에 상당한 위험을 초래하였으며, 현 상태는 각 고분에 대한 보강이 불가피한 것으로 판단된다. 고분 벽돌의 깨짐, 고분 벽체의 거동, 조류의 서식등을 포함하여 송산리 고분군에서 발생되고 있는 보존상의 제반 문제점들을 일차적으로 누수 및 침투수에 의한 결과이다. 그러므로 무엇보다도 고분군 내부 및 고분 주변으로의 강우 및 지하수 침투를 막는 차수 대책이 시급한 것으로 판단된다. 또한 이미 발생한 변위가 더 이상 진행되지 않도록 하중을 경감하고 토압의 균형을 이루는 보강대책이 시급한 실정이다. 고분군

  • PDF

Stress distribution of implants with external and internal connection design: a 3-D finite element analysis (내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석)

  • Chung, Hyunju;Yang, Sung-Pyo;Park, Jae-Ho;Park, Chan;Shin, Jin-Ho;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.189-198
    • /
    • 2017
  • Purpose: This study aims to analyze the stress distribution of mandibular molar restoration supported by the implants with external hex and internal taper abutment connection design. Materials and Methods: Models of external connection (EXHEX) and internal connection (INCON) implants, corresponding abutment/crowns, and screws were developed. Supporting edentulous mandibular bony structures were designed. All the components were assembled and a finite element analysis was performed to predict the magnitude and pattern of stresses generated by occlusal loading. A total of 120 N static force was applied both by axial (L1) and oblique (L2) direction. Results: Peak von Mises stresses produced in the implants by L2 load produced 6 - 15 times greater than those by L1 load. The INCON model showed 2.2 times greater total amount of crown cusp deflection than the EXHEX model. Fastening screw in EXHEX model and upside margin of implant fixture in INCON model generated the peak von Mises stresses by oblique occlusal force. EXHEX model and INCON model showed the similar opening gap between abutment and fixture, but intimate sealing inside the contact interface was maintained in INCON model. Conclusion: Oblique force produced grater magnitudes of deflection and stress than those by axial force. The maximum stress area at the implant was different between the INCON and EXHEX models.

Thermo-mechanical Behavior of WB-PBGA Packages with Pb-Sn Solder and Lead-free Solder Using Moire Interferometry (무아레 간섭계를 이용한 유연 솔더와 무연 솔더 실장 WB-PBGA 패키지의 열-기계적 변형 거동)

  • Lee, Bong-Hee;Kim, Man-Ki;Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • Pb-Sn solder is rapidly being replaced by lead-free solder for board-level interconnection in microelectronic package assemblies due to the environmental protection requirement. There is a general lack of mechanical reliability information available on the lead-free solder. In this study, thermo-mechanical behaviors of wire-bond plastic ball grid array (WB-PBGA) package assemblies are characterized by high-sensitivity moire interferometry. Experiments are conducted for two types of WB-PBGA packages that have Pb-Sn solder and lead-free solder as joint interconnections. Using real-time moire setup, fringe patterns are recorded and analyzed for several temperatures. Bending deformations of the assemblies and average strains of the solder balls are investigated and compared for the two type of WB-PBGA package assemblies. Results show that shear strain in #3 solder ball located near the chip shadow boundary is dominant for the failure of the package with Pb-Sn solder, while normal strain in #7 most outer solder ball is dominant for that with lead-free solder. It is also shown that the package with lead-free solder has much larger bending deformation and 10% larger maximum effective strain than the package with Pb-Sn solder at same temperature level.