• Title/Summary/Keyword: 큰 대퇴 골두

Search Result 10, Processing Time 0.02 seconds

Avascular Necrosis of Femoral Head on Bone Scan (대퇴골두 무혈성 괴사의 뼈스캔상의 병기)

  • Yang, Hyung-In;Kim, Eui-Jong;Kim, Deog-Yoon;Ryu, Kyung-Nam;Cho, Kyung-Sam
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.206-213
    • /
    • 1994
  • We studied 90 patients(179 femoral heads) with avascular necrosis of femoral head, who had been performed X-ray, bone scan and MRI to compare of the findings of AVN on bone scan between each other, retrospectively. The patients were 82 males and 9 females, their mean age was 45 years. Radiographic stages were classified by Steinberg modification, radionuclide stages were classified as followed; stage o(or type 0) : normal, stage 1 : faint ring like uptake around the femoral head, stage 2: intense ring like uptake, stage 3: irregular increased uptake with central photon defect, stage 4 : Intense diffuse increased uptake at femoral head and stage 5 : hip joint deformity with relatively mild increased uptake. The findings of MRI were classified according to extent, location, early or advanced lesion, signal intensity of the lesion and joint effusion. 156(87%) of 179 femoral heads had avascular necrosis, 68(75.5%) of 90 patients had bilateral AVN, 35 femoral heads had early stage and 120 had advanced stage. The detection rate of AVN by X-ray and bone scan were 85% (134), 91.6% (143), respectively. Early AVN with atypical types of bone scan showed larger extent, moderate to large amount of joint effusion, soft tissue hypertrophy within joint, and secondary degenerative changes. Bone scan had relatively high detection rate in the diagnosis of AVN of femoral head, and demonstrated various types depending on the disease stage.

  • PDF

Initial Plain Radiographs versus MR Imaging: Comparison of Prognostic Efficacy in Legg-Calve-Perthes Disease (초기의 단순 X선 촬영술 대 자기공명영상: 소아성 대퇴골두 무혈성 괴사증에서 예후 예측성 비교)

  • Lee, Sun-Jin;Jee, Won-Hee;Cho, Song-Mee;Jeong, Chang-Hoon;Ok, In-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.153-160
    • /
    • 2008
  • Purpose : To evaluate if at the time of diagnosis of Legg-Calve-Perthes disease, MR imaging is superior to radiographs for identifying patients with a favorable long term prognosis as determined by maintenance of a spherical configuration of the femoral head epiphysis on follow-up radiographs. Materials and Methods : We retrospectively analyzed plain radiographs and MR images of 48 femoral heads in 41 patients with Legg-Calve-Perthes disease at time of diagnosis. Femoral head involvement was estimated on initial plain radiographs and MR images using the Catterall classification. Prognosis as determined by maximum femoral head deformity was determined on follow-up radiographs evaluated according to Stulberg classification. Results: Catterall classification of greater than 1 at MR imaging had 100% sensitivity (14/14) for detecting patients with a poor prognosis as indicated by deformity of the femoral head on follow-up radiographs (Stulberg class > 2). Initial radiographs had a lower sensitivity of 57% (8/14) for detecting patients with poor prognosis. Specificity for MR imaging was 21% (7/34) which was not significantly different from 32% (11/34) specificity for initial radiographs. Conclusion: Catterall group 1 at initial MR imaging indicates favorable prognosis for Legg-Calve-Perthes disease. Patients with more extensive involvement of the femoral head can have a good outcome, however they are at risk for loss of spherical configuration of the femoral head and subsequent osteoarthritis in adulthood. MR imaging may be superior to radiographs for identifying a subgroup of patients with favorable prognosis.

  • PDF

Analysis on Femoral Neck Fractures Using Morphological Variations (파라메트릭 형상모델을 이용한 근위 대퇴골의 경부 골절 영향 해석)

  • Lee, Ho-Sang;Park, Byoung-Keon;Chae, Je-Wook;Kim, Jay-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.459-465
    • /
    • 2011
  • It has been reported that the femoral morphology has a major correlation to femoral neck fractures(FNF). Previous studies to analyze these correlations have relied on mechanical testing and finite element methods. However, these methods have not been widely applied to various femur samples and models. It is because of the availability of the samples from both patients and cadavers, and also of the geometric limitations in changing the shape of the models. In this study we analyzed femoral neck fractures using a parameterized femoral model that could provide flexibility in changing the geometry of the model for the wide applications of FNF analysis. With the parameterization a variety of models could be generated by changing four major dimensions: femoral head diameter(FHD), femoral neck diameter(FND), femoral neck length(FNL), and neck-shaft angle(NSA). We have performed FEA on the models to compute the stress distributions and reaction forces, and compare them with the data previously generated from mechanical testing. The analysis results indicate that the FND is significantly related with the FNF and the FHD is not significantly related with the FNF.

Percutaneous Radiofrequency Therapy of Benign Bone Tumors in the Femoral Head (대퇴골두 부위에 발생한 양성 골 종양에 대한 경피적 고주파치료 (증례보고))

  • Seo, Jai-Gon;Kim, Eung-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.84-92
    • /
    • 2003
  • Purpose: To report two cases of bone tumors other than osteoid osteoma in the proximal femur and treated with percutaneous high frequency radioablation method. Cases: We reviewed two cases with intracortical chondroma and enchondroma in the femoral head retrospectively. The patient with intracortical chondroma was a thirty one year old woman and had suffered right hip pain of 1 year duration. The lesion was located in the head of right femur and treated with CT guided percutaneous high frequency radioablation after needle biopsy under general anesthesia. The symptom was gone immediately after the procedure and was discharged postop. 1 day. 15 months has passed without symptom recurrence. Second case having enchondroma, was 56 year old woman complaining of gluteal area pain for 3 months. Radiologic evaluation showed osteolytic lesion with sclerotic rim on the inferior portion of the left femoral head. She received a same therapy with CT guided radiofrequency ablation following needle biopsy. She reported dramatic pain relief after the procedure and was discharged postop. 1 day. No symptom has occurred for 3 months until now. Conclusion: We present 2 cases of bone tumor occurred in the hip joint area other than osteoid osteoma which were treated with CT guided radiofrequency ablation.

  • PDF

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Dose Assessment in Accordance with the Measured Position of Size Specific Dose Estimates (Size Specific Dose Estimates(SSDE)측정 위치에 따른 피폭선량 평가)

  • Kim, Jung-Su;Hong, Sung-Wan;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.383-387
    • /
    • 2015
  • This study investigated the size specific dose estimates of difference localizer on pediatric CT image. Seventy one cases of pediatric abdomen-pelvic CT (M:F=36:35) were included in this study. Anterior-posterior and lateral diameters were measured in axial CT images. Conversion factors from American Association of Physicists in Medicine (AAPM) report 204 were obtained for effective diameter to determine size specific dose estimate (SSDE) from the CT dose index volume (CTDIvol) recorded from the dose reports. For the localizer of mid-slice SSDE was 107.63% higher than CTDIvol and that of xiphoid-process slices SSDE was higher than 92.91%. The maximum error of iliac crest slices, xiphoid process slices and femur head slices between mid-slices were 7.48%, 17.81% and 14.04%. In conclusion, despite the SSDE of difference localizer has large number of errors, SSDE should be regarded as the primary evaluation tool of the patient radiation in pediatric CT for evaluation.

The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography (고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Ho-Beom;Na, Sa-Ra;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5682-5688
    • /
    • 2013
  • The purpose of this study is to maximize diagnositc usefulness with increasing signal to noise ratio(SNR) and contrast to noise ratio(CNR) by using a 1mmol/mL gadolinium contrast agent. From January 2012 to June 2013 fourty-seven patients were underwent the MRI scanning to investigate the contrast difference in gadolinium content. Twenty of the patients were injencted the commercial contrast agent containing 0.5mmol/mL gadolinium and the rest of them were injected the new contrast agent containing 1mmol/mL gadolinium called gadobutrol. We measured and evaluated each SNR and CNR of the hip joint space, iliopsoas muscle and femoral head. As a result, using the 1mmol/mL gadolinium contrast agent had the higher SNR results than using the 0.5mmol/mL agent(27% in the hip joint, 30.01% in the femoral head). Also CNR using the 1mmol/mL gadolinium agent was proved to be higher than that of using 0.5mmol/mL agent(28.31% in the ilopsoas muscle and 26.74% in the femoral head). Therefore, the contrast agent containing more gadolinium like 1mmol/mL used in this study is more effective to shorten T1 relaxation time, so it increases the signal intensity and CNR and furthermore maximizes diagnostic value. This study reports the usefulness of the 1mmol/mL contrast agent in the contrast-enhanced magnetic resonance hip arthrography for the first. Therefore, it can be considered to have an meaningful academic value as showing the method for increasing the diagnostic usefulness by using the 1mmol/mL contrast agent.

Study of overlapping setting up of Planning Target Volume for Improving Target Coverage adjacent Organ At Risk (손상위험장기에 인접한 표적 Coverage 개선을 위한 Planning Target Volume 중복 설정에 관한 연구)

  • Lee, Jung Woong;Kim, Bo Kyum;Mun, Jun Ki;Woo, Hun;Lee, Yang Hoon;Jeon, Chang Woo;Lee, Jea Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the reduction of coverage of PTVs adjacent to organ at risk (OAR) by setting up overlapping Planning Target Volume (PTV) during Volumetric Modulated Arc Therapy(VMAT). Materials and Methods: In patients who received Whole Brain, Gall Bladder and Rectum radiation therapy, We compared the cover change, maximum dose, Homogenicity Index and Conformity Index of PTV and also compared the maximum dose and average dose change of Organ At Risk by organizing treatment plans that are not applied overlaped PTV and treatment plans that are applied overlaped PTV in areas where coverage is insufficient. Results: overage of treatment plans with overlapping PTVs was increased in all patients, and overall coverage was also increased in each of the four patients. The maximum dose for PTV was increased in five patients, and the Homogenicity Index and Conformity Index for all patients did not differ much. The maximum dose of the lens was increased by 1.12 times, and the maximum dose was decreased in two patients for brain stem. The mean dose of the eyeball was increased by a maximum of 1.15 times, and there was no significant difference between both parotid gland. In case of gallbladder cancer patients, the mean dose in the liver and colon was decreased, and the mean dose in the duodenum was increased. In the case of rectal cancer patients, the mean dose was reduced for both femur and bladder set as OARs. The overall MU was shown to be similar in four patients, excluding one. Conclusion: If the critical dose of OAR is considered and used properly, I think it is a useful way to improve coverage of PTV.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.