• Title/Summary/Keyword: 크로스-체인

Search Result 28, Processing Time 0.055 seconds

Comparison of metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture (상악 총의치 정중 파절 수리 시 금속선 및 유리섬유의 보강효과 비교)

  • Lee, Jung-Ie;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.284-291
    • /
    • 2013
  • Purpose: This study compared fracture strength and fracture modes between metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture. Materials and methods: In this study, fracture was reproduced on center of maxillary complete dentures and the denture was repaired with auto-polymerizing resin. The experimental groups (n = 10) were subjected to the following condition: without reinforcing material (control group), reinforcing with metal wire (W group), reinforcing with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheon, Korea, G group). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The Kruskal-wallis test and the Mann-whitney U test were performed to identify statistical differences at ${\alpha}=.05$. Results: W group showed the highest value of fracture strength, there was no significant difference (P>.05) between control group and G group. Control group and W group showed anteroposterior fracture mainly, group W showed adhesive fracture of denture base and reinforcing material. Conclusion: In limitation of this study, the glass fiber did not improve the fracture strength of repaired maxillary complete denture, and adhesive failure was occurred along the lines of glass fiber.

Perfluorinated Sulfonic Acid based Composite Membranes for Vanadium Redox Flow Battery (바나듐 레독스 흐름 전지를 위한 과불소화 술폰산 복합막)

  • Cho, Kook-Jin;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.1
    • /
    • pp.21-27
    • /
    • 2016
  • Vanadium redox flow batteries (VRFBs) using the electrolytes containing various vanadium ions in sulfuric acid as supporting solution are one of the energy storage devices in alternatively charging and discharging operation modes. The positive electrolyte contains $V^{5+}/V^{4+}$ and the negative electrolyte $V^{2+}/V^{3+}$ depending on the operation mode. To prevent the mixing of two solutions, proton exchange membranes are mainly used in VRFBs. Nafion 117 could be the most promising candidate due to the strong oxidative property of $V^{5+}$ ion, but causes high crossover of electroactive species to result in a decrease in coulombic efficiency. In this study, the composite membranes using Nafion ionomer and porous polyethylene substrate were prepared to keep good chemical stability and to decrease the cost of membranes, and were compared to the properties and performance of the commercially available electrolyte membrane, Nafion 117. As a result, the water uptake and ionic conductivity of the composite membranes increased as the thickness of the composite membranes increased, but those of Nafion 117 slightly decreased. The permeability of vanadium ions for the composite membranes significantly decreased compared to that for Nafion 117. In a single cell test for the composite membranes, the voltage efficiency decreased and the coulombic efficiency increased, finally resulting in the similar energy efficiency. In conclusion, the less cost of the composite membranes by decreasing 6.4 wt.% of the amount of perfluorinated sulfonic acid polymer due to the introduction of porous substrate and lower vanadium ion permeability to decrease self-discharge were achieved than Nafion 117.

Characteristics of Beam-tilting Slot Array Waveguide Antennas for DBS Reception (DBS 수신용 빔 틸트형 슬롯 어레이 도파관 안테나의 특성)

  • Min, Gyeong-Sik;Kim, Dong-Cheol;Arai, Hiroyuki
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.140-149
    • /
    • 2002
  • This paper describes the characteristics of beam-tilting slot away waveguide antennas for mobile DBS reception. As a basic study of slotted waveguide array, design for 16 slot elements located on a broad-wall waveguide is considered. Design parameters such as slot length, space between each slot and cross slot angle of antennas with the beam-tilting characteristics are calculated by method of moments. Based on these results, the radiation waveguide antennas with 16-element $\times$16-array are designed and fabricated. The measured main beam direction angles of the fabricated antennas are 48$^{\circ}$to 50$^{\circ}$depending on the measured frequencies and it shows good agreement with prediction. The measured 3 dB beam width of elevation pattern is about 13$^{\circ}$, and the axial ratio and the gain measured at DBS band are observed 2.8 dB below and 24 dBi above, respectively. In order to evaluate a performance of the fabricated waveguide planar antenna, it is combined with the satellite tracking control system and the field performance test of antenna mounted on a mobile vehicle is carried out at highway. During the measurement, it was possible to watch television without a break signal in a driving vehicle and an excellent performance of the proposed antennas was demonstrated.

Evaluation of Cell Components in Direct Formic Acid Fuel Cells (직접 개미산 연료전지의 구성요소 평가에 대한 연구)

  • Jung, Won Suk;Yoon, Sung Pil;Han, Jonghee;Nam, Suk Woo;Lim, Tae-Hoon;Oh, In-Hwan;Hong, Seong-Ahn
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.362-367
    • /
    • 2009
  • Recently, the use of formic acid as a fuel for direct liquid fuel cells has emerged as a promising alternative to methanol. In the work presented herein, we evaluated direct formic acid fuel cells(DFAFCs) with various components under operating conditions, for example, the thickness of the proton exchange membrane, concentration of formic acid, gas diffusion layer, and commercial catalyst. The thickness of the proton exchange membrane influenced performance related to the fuel cross-over. To optimize the cell performance, we investigated on the proper concentration of formic acid and catalyst for the formic acid oxidation. Consequently, membrance-electrode assembly(MEA) consisted of $Nafion^{(R)}$-115 and the Pt-Ru black as a anode catalyst showed the maximum performance. This performance was superior to the DMFCs' one.

A Study of Dual-Frequency Microstrip Patch Antenna (이중공진 마이크로스트립 패치 안테나에 관한 연구)

  • 장준영;김준모;윤영중;엄순영;전순익
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.515-525
    • /
    • 1998
  • In this paper, for both transmission and reception with single antenna system of satellite communication, dual-frequency antennas which operate simultaneously at 12.5 GHz and at 14.25 GHz are designed, constructed and measured. Also by using dual feeding structure, the problems of single-fed dual-frequency antenna such as the separation of transmitting and receiving signals and single polarization, are solved. Microstrip patch as a radiation element of dual-fed dual-frequency antenna has width and length which are the resonance lengths of the corresponding frequencies for transmission and reception, respectively. The effects of the feed line on the other frequency feeding are minimized with the optimal matching scheme for the feed lines. For solving the space problems of dual-fed two-dimensional array antennas, microstrip-line and coaxial probe feedings are used for each frequency and a two-dimensional $2\times2$ array antenna was designed and measured their characteristics. The experimental results show that errors of resonance frequencies are less than 1.44%, the return losses are less than -21 dB and the isolations between two feeding ports are less than -21 dB. The characteristics of radiation patterns of dual frequency microstrip antenna are measured and evaluated. The directivities, sidelobe levels and cross polarizations are also measured and compared with the simulations. The results show some errors due to the misalignment of coaxial probe feeding.

  • PDF

Active Material Crossover through Sulfonated Poly (Ether Ether Ketone) Membrane in Iron-Chrome Redox Flow Battery (철-크롬 산화환원흐름전지에서 Sulfonated Poly (Ether Ether Ketone)막의 활물질 Crossover)

  • Kim, Young-Sook;Oh, So-Hyeong;Kim, You-Jeong;Kim, Seong-ji;Chu, Cheun-Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.17-21
    • /
    • 2019
  • The redox flow battery (RFB) is a large-capacity energy storage equipment, and the vanadium redox flow cell is a typical RFB, but VRFB is expensive. Iron-chrome RFBs are economical because they use low-cost active materials, but their low performance is an urgent problem. One of the reasons for the low performance is the crossover of the active materials. In this study, the sulfonated Poly (ether ether ketone) (sPEEK) membrane, which is a hydrocarbon membrane, was used instead of the fluorine membrane to reduce the crossover of the active materials. The chromium ion permeability of the sPEEK membrane was $1.8{\times}10^{-6}cm^2/min$, which was about 1/33 of that of the Nafion membrane. Thus, it was shown that the use of the sPEEK membrane instead of the fluorine membrane could solve the high active material crossover problem. The activation energy of iron diffusion through the sPEEK membrane was 24.9 kJ/mol, which was about 66% of Nafion membrane. And that the e-PTFE support in the polymer membrane reduces the active material crossover through Iron-Chrome Redox Flow Battery (ICRFB).

Exploration and Development of the Taebaek Orebody in the Yeonwha Pb-Zn Mine (연화광산(蓮花鑛山)의 태백광체탐사(太白鑛體探査)와 개발현황(開發現況))

  • Je, Young-Kun;Lee, Eun-Jae
    • Economic and Environmental Geology
    • /
    • v.20 no.4
    • /
    • pp.273-288
    • /
    • 1987
  • 연화(蓮花) 연(鉛) 아연광산(亞鉛鑛山)은 광체(鑛體)의 분포(分布)에 따라 본산지구(本山地區), 동점지구(銅店地區) 및 태백지구(太白地區)로 구분할 수 있다. 태백지구(太白地區)에 대한 본격적인 탐광(探鑛)이 시작되기 전인 1981년 당시, 약 25년 동안 채광작업(採鑛作業)이 진행되어 온 본산지역(本山地域)은 주종광체(主宗鑛體)인 월암(月岩) 및 남산광체(南山鑛體)가 -600m level에서 하한(下限)이 드러남에 따라 광량(鑛量)이 크게 소진(消盡)된 상태였으며, 동점지성(銅店地城)은 상하(上下)의 광황변화(鑛況變化)는 크지 않으나 광체(鑛體)의 규모(規模)가 비교적 작아, 조업(操業)의 안정(安定)을 위해서는 신광화대(新鑛化帶)의 개발(開發)이 시급(時急)한 과제(課題)로 대두되었다. 이에 따라 평천(平川), 태백(太白), 동점역(銅店驛), 방터골, 삼방산광화대(三芳山鑛化帶) 등 연화(蓮花) 전역(全域)에 걸쳐 모암(母岩)의 분포(分布), 지질구조(地質構造), 광징(鑛徵) 등을 검토한 결과 탐광대상(探鑛對象)에서 제외되어 왔던 태백지구(太白地區)가 다음과 같은 점에서 유망(有望)한 탐사후보지(探査候補地)로 부각되었다. 첫째, 지표(地表)에서는 풍촌석회암층(豊村石灰岩層)이 분포(分布)되지 않으나 지질구조(地質構造)를 검토한 결과 -300m level 하부(下部)에서는 이의 전층(全層)이 분포(分布)할 것으로 예상되며, 둘째, 두무동층(斗務洞層) 및 동점규암층내(銅店珪岩層內)에서 발견된 광징(鑛徵)들이 하부(下部)의 풍촌석회암내(豊村石灰岩內)로 연장(延長)되면 부광부(富鑛部)를 이룰 것으로 기대되고, 셋째, 지층(地層)의 경사(傾斜)가 $50^{\circ}$ 이상(以上)인 점, 석영반암(石英斑岩)이 분포(分布)하는 점 등은 광상배태(鑛床胚胎)에 양호(良好)한 조건(條件)이고, 넷째, 본산지구(本山地區)의 월곡(月谷), 월암(月岩), 남산(南山)등 주종광화대(主宗鑛化帶)의 연장부(延長部)인 점, 다섯째, 중앙견갱(中央堅坑)으로부터 약 2km 거리로 탐사단계(探査段階)에 별도의 신규투자(新規投資) 없이 굴진(掘進)이 가능하다는 개발조건상(開發條件上)의 이점(利點)이 있었다. 이에 따라 태백지구(太白地區)에 대한 지표정사(地表精査), 물리탐사(物理探査) 및 지화탐(地化探)을 실시하고, 20여년간 축적된 연화광산(蓮花鑛山)의 지질(地質), 광상자료(鑛床資料)를 정리(整理), 그 특성(特性)을 태백지구(太白地區) 탐사(探査)의 가설(假說)로 적용하여 시추계획(試錐計劃)을 수립, 1982년 구조시추(構造試錐)를 실시한 결과 지질구조(地質構造), 풍촌석회암층(豊村石灰岩層)의 분포(分布) 등이 거의 예상했던 대로 밝혀졌으며 태백(太白) 1호광체(號鑛體)의 일단(一端)이 확인되기에 이르렀다. 1983년(年) 7월(月) 본산지구(本山地區) -600m level에서 태백(太白) 크로스 탐광굴진(探鑛掘進)이 착수되었으며, 1985년에 마침내 갱내(坑內)에서 태백(太白) 1호(號), 2호(號) 광체(鑛體)가 착광(着鑛)되었다. -600m level에서의 태백(太白) 1호광체(號鑛體)의 규모(規模)는 연장(延長) 300m, 평균맥폭(平均脈幅) 8.5m이며, 품위(品位)는 Pb 4.5%, Zn 4.5%, Ag 109g/t이다. 태백광화대(太白鑛化帶)의 지질학적(地質學的) 예상광량(豫想鑛量)은 1,000만(萬)t 이상(以上)이 될 것으로 추정(推定)되며, 현재 -480m level에서 -720m level에 이르기까지 5개 level에서 가행(稼行)되고 있다. 현재 level에서 태백(太白) 1호(號) 광체(鑛體)는 풍촌석회암층(豊村石灰岩層) 및 화절층(花折層)을 모암(母岩)으로 하여 맥상광상(脈狀鑛床)으로 생산(生産)되며, 맥석광물(脈石鑛物)은 능망간석, Mn-방해석(方解石), 방해석(方解石), 석영(石英) 등이고 광석광물(鑛石鑛物)은 섬아연석(閃亞鉛石), 방연석(方鉛石), 황철석(黃鐵石), 자유철석(磁硫鐵石), 유비광석(硫砒鑛石), 황동석(黃銅石), 사면동석(四面銅石), 엘렉트럼 등이다. 태백지구(太自地區)는 광상(鑛床)의 산출상태(産出狀態) 및 지질(地質), 광상학적(鑛床學的) 환경(環境)이 본산지구(本山地區)와 거의 동일(同一)함이 밝혀지고 있다. 태백지구(太白地區)에서는 현재 태백(太白) 1호(號), 2호(號), 3호(號), 5호(號) 및 절골 1호(號), 2호(號) 등 6개 광화대(鑛化帶)에 대한 탐광(探鑛)이 진행되고 있다.

  • PDF

Effect of location of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture (광중합형 레진에 함침시킨 유리섬유의 위치가 상악 총의치의 파절강도와 파절양상에 미치는 영향)

  • Yoo, Hyun-Sang;Sung, Su-Jin;Jo, Jae-Young;Lee, Do-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • Purpose: This study evaluated the effect of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture. Materials and methods: Maxillary acrylic resin complete dentures reinforced with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheongun, Korea) and without reinforcement were tested. The reinforcing material was embedded in the denture base resin and placed different regions (Control, without reinforcement; Group A, center of anterior ridge; Group B, rugae area; Group C, center of palate; Group D, full coverage of denture base). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The data were analyzed with one-way ANOVA at the significance level of 0.05. Results: There were non-significant differences (P>.05) in the fracture strength among test groups. Group A showed anteroposterior fracture and posterior fracture mainly, group B, C and control group showed partial fracture on center area mostly. Most specimen of group D showed posterior fracture. Conclusion: The location and presence of the fiber reinforcement did not affect the fracture strength of maxillary complete denture. However, reinforcing acrylic resin denture with glass fiber has a tendency to suppress the crack.