• Title/Summary/Keyword: 콘크리트 코어

Search Result 149, Processing Time 0.018 seconds

Evaluation for Applicability of Reinforced Concrete Structure with Domestic Pond Ash (국산 매립회 골재를 사용한 콘크리트 구조물의 적용성 평가)

  • Lee, Bong-Chun;Jung, Sang-Hwa;Chae, Sung-Tae;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.541-550
    • /
    • 2011
  • Many researches have been performed on concrete with fly ash and bottom ash. However researches on concrete with pond ash (PA) and its application to RC (Reinforced Concrete) structure are limitedly carried out. This paper presents an applicability of PA concrete in construction of real size structure. Referring to the previous study, 2 domestic PA samples with normal performance are selected and 2 replacement ratios (25% and 50%) to fine aggregate are considered for 5 PA concrete structures consisting of column, slab, and wall. In order to evaluate the property of fresh concrete, several tests including air content, slump, and setting time are performed. Using cored out samples from hardened PA concrete structure, tests for strength, resistance to carbonation and chloride penetration are carried out and compared with control samples. Additionally, tests for rebound hardness, drying shrinkage, and hydration heat are performed for PA concrete structure. The test results showed that PA concrete has reasonable strength and durability performances compared to those of normal concrete. Therefore, its potential application to RC structure is promising. The PA aggregate can be more actively used for RC structures with better quality control for content of fly ash, bottom ash, and unburned carbon.

Strength Prediction Equations for High Strength Concrete by Schmidt Hammer Test (슈미트 해머 시험에 의한 고강도 콘크리트의 강도 추정식)

  • Kwon, Young-Wung;Park, Song-Chul;Kim, Min-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.389-395
    • /
    • 2006
  • For the assessment of exsiting concrete structures, it is important to get the real strength of concrete. The load test or core test has many problems due to cost time, easiness, structural damage, and reliability and so on. Thus, various non-destructive test and statistical analysis techniques for strength assessment have been developed. As a result the real strength of concrete can be obtained by both direct and indirect test. In this study, a series of experimental tests of core strength and Schmidt hammer tests on 3, 7, 14, 28, 90, 180, 365, and 730 days' were done for predicting the compressive strength of high strength concrete with 65.0MPa of 28-days' strength. Each experimental results was analyzed by simple regression analysis. Then, reliability level and error rate between the proposed equations and the existing ones was examined. However, the application of the exsisting equations was inadequate to high strength concrete, because they were conducted under normal strength concrete. Therefore, the following compressive strength equations were proposed for predicting the compressive strength of high strength concrete by Schmidt hammer test. The proposed equations by Schmidt hammer test are as follows.

The Estimation of Durability Factor of Deteriorated Jointed Concrete Pavement Using Image Analysis Test (화상분석 실험을 이용한 열화된 줄눈콘크리트 포장의 내구성 지수 평가)

  • Choi, Pan-Gil;Kim, Yong-Gon;Yun, Kyong-Ku;Kwon, Soo-Ahn
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.31-38
    • /
    • 2009
  • The primary objective of this study was to estimate the deterioration degree of jointed concrete pavement which was major concrete pavement type in Korea. First of all, visual survey of concrete pavement was performed to observe deterioration types. In the result of visual survey, the majority of concrete pavement deterioration was investigated in joint area. It is appeared that most of the distresses are durability cracking and joint distress. Second, concrete core specimens were taken from eight locations including good section (4 locations) and bad section (4 locations) based on visual survey. The deterioration reasons of concrete pavement were analyzed with ultrasonic pulse velocity test, splitting tensile strength test, and image analysis for concrete core specimens. Among the image analysis test result for 21 concrete core specimens, only two specimens satisfied the Kansas DOT criteria of spacing factor, $250\;{\mu}m$, and the remains of 19 specimens were estimated to be above $250\;{\mu}m$. The durability factor of concrete was estimated very low. As a result, it was analyzed that the main deterioration reason of the deteriorated jointed concrete pavement was to be freezing and thawing damages.

A Study for In-situ Application of High Strength Antiwashout Underwater Concrete (고장도용 수중불분리성 콘크리트의 현장적용을 위한 연구)

  • 문한영;송용규;이승훈;정재홍
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.336-345
    • /
    • 2001
  • The construction of underwater structures has been increased, but underwater concrete hassome problems of quality deterioration and contamination around in-situ of civil and architecture; therefore, new materials and methods for them are demanded. In this paper in-situ application of underwater antiwashout concrete which is manufactured for trio purpose of not only decreasing suspended solids and the heat of hydration but also increasing long term strength was studied. In the case of mock-up test(Ⅰ), when underwater antiwashout concrete, whose slump flow was 58 cm, was placed in the mock-up test at a speed of 24 ㎥/hr, it took about a minute to flow to the side wall, and the surface was maintained at horizontal level. In this case, compressive strength of the core specimens in each section was higher than the standard design compressive strength of 240 kgf/㎠. In the case of mock-up test(II), pH value and suspended solids of high strength underwater antiwashout concrete were 10.0∼11.0 and 51 mg/ℓ at 30 minutes later, initial and final setting time were about 30, 37 hr, and the slump flow of that was 53$\pm$2 cm. In the placement at a speed of 27 ㎥/hr, there was no large difference in flowing velocity, with or without reinforcement and flowing slope was maintained at horizontal level. In this case, compressive strength and elastic modulus of the core specimens somewhat decreased as flowing distance was far : however, those of central area showed the highest value.

Development of Fatigue Model for Airfield Concrete Pavement (공항 콘크리트 포장의 피로모형 개발 연구)

  • Kwon, Soo-Ahn;Yang, Hong-Seok;Suh, Young-Chan
    • International Journal of Highway Engineering
    • /
    • v.6 no.3 s.21
    • /
    • pp.27-35
    • /
    • 2004
  • There are two methods in estimating the remaining life of in-service airfield concrete pavement. They are a method simply using the past accumulated traffic and a method using the theoretical mechanistic analysis. Since the former method is somewhat far from the actual condition, the latter method is widely used by most engineers and researchers. The most essential component of the latter method is the fatigue model of the concrete slab. A fatigue model for airfield concrete pavement is developed in this study by a series of fatigue tests using 30 concrete cylinder specimens obtained from a 10 year old in-service airfield concrete slab. Strengths for the stress ratio calculation were obtained from the split tensile test of the cores sliced. Fatigue test mode was repeated split tensile test. The R2 of developed fatigue model was 0.5. Specimens taken from another airport had been tested for validation of the model. The results showed a good fit to the model. It was also found that the fatigue life predicted from the model was a tittle greater when the stress ratio is greater than 80 percent than other fatigue models developed earlier in America.

  • PDF

Evaluation of Service Life in RC Column under Chloride Attack through Field Investigation: Deterministic and Probabilistic Approaches (염해 실태조사를 통한 철근 콘크리트 교각의 내구수명 평가 - 결정론적 및 확률론적 해석방법)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • RC (Reinforced Concrete) structures are considered as cost-benefit and durable however performances of structural safety and durability are degraded due to steel corrosion. Service life in RC structure is differently evaluated due to different local environmental conditions even if it is exposed to the same chloride attack. In the paper, 25 concrete cores from field investigation are obtained from 4 RC columns with duration of 3.5~4.5 years exposed to sea water. Through total chloride content measurement, surface chloride contents and apparent diffusion coefficients are evaluated. Service life of the target structure is estimated through deterministic method based on Fick's $2^{nd}$ Law and probabilistic method based on durability failure probability, respectively. Probability method is evaluated to be more conservative and relatively decreased service life is evaluated in tidal zone and splash zone over 40.0 m. Chloride penetration behavior with coring location from sea level and the present limitations of durability design method are investigated in the paper.

Development of a Concrete Pump Truck's Core Pump Model and Its Validation (콘크리트 펌프트럭의 코어펌프 해석모델개발 및 신뢰성 검토)

  • Park, Sung Su;Noh, Dae Kyung;Lee, Geun Ho;Lee, Dae Hee;Jang, Ju Sup
    • Journal of Drive and Control
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2018
  • This study is a first step toward reducing surge pressure, and it has another purpose, which is to developing an analysis model which can closely analyze a hydraulic circuit and be used in design. For development of analysis model, SimulationX, a commercial program, is used. The study progress methods are as follows. By analyzing the structure and operating mechanisms of each part of the hydraulic system of the pump truck and referring its parameters, develop a single component model. Assemble the developed single component model, and make an overall analysis the model. By comparing the similarities between the developed model and the actual system's test results, validate the reliability of the analysis model.

A Study on Evaluation of Complex Deterioration evaluation and Prediction of Residual Life through Concrete Core (콘크리트 코어 분석을 통한 복합열화 평가와 잔존수명 예측 연구)

  • Shim, Jaeyoung
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.332-339
    • /
    • 2017
  • In the case of aged structures, the information of the structure is often lost after the completion of construction, and there is a great difficulty in predicting the durability life of the structure due to the lack of information on concrete formulations. In this study, the durability of concrete specimens was evaluated by various field and indoor test methods based on the core specimens collected from the field, and the durability life of the concrete structures was predicted by using the FEM analysis technique.As a result, the neutralization rate coefficient was $5.38E-6(cm^2/day)$ and the rate of progress was low. And the possibility of complex deterioration due to carbonation and salting was found to be very low.

Field Application of Rapid Neutralization Assessment Method Using Core Drilling in Concrete Structures (코어드릴링에 의한 중성화 신속평가 방법을 이용한 콘크리트 구조물의 중성화 현장 적용성 평가)

  • Lim, Gun-Su;Lee, Hyeon-Jik;Beak, Sung-Jin;Lee, Hyuk-Ju;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.15-16
    • /
    • 2023
  • In this paper, we aimed to develop a new method for diagnosing the depth of neutralization in architectural and civil engineering structures using the core drilling method, which combines the speed of drilling with the accuracy of core ringing. When compared to the drilling method, the core drilling method showed a lower measurement deviation of 1-2mm (7.6%) in confirming the depth of neutralization. This is believed to be a result of potential interference during the sample collection process in the drilling method, where the drill may pass through aggregates, leading to overestimation, as indicated in previous studies. The rapid evaluation of neutralization using the core drilling method serves as an alternative to address the issues associated with both drilling and core ringing methods in diagnosing the depth of neutralization. It offers a solution to the inaccuracy caused by coarse aggregates and the cumbersome post-processing steps required for neutralization diagnosis. Our proposed technique aims to provide an accurate and expedited diagnosis of neutralization depth without the need for additional processes.

  • PDF

Penetration of De-icing Salt in Bare Concrete Bridge Decks in Highways (고속도로 콘크리트 노출 바닥판에서의 제설 염화물의 침투 특성)

  • Suh, Jin Won;Ku, Bon Sung;Rhee, Ji Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.85-92
    • /
    • 2007
  • In 1980s, a number of bridges with bare concrete deck were constructed on the Korea highway. After 20 years service, many bare concrete decks are still in good condition without special maintenance activity. Therefore, the application of the bare concrete deck is being reestimated from the view of construction and maintenance. As a part of the program, the characteristic of penetration(surface chloride and apparent diffusion coefficient) of de-icing salt into bare concrete bridge deck was analyzed in order to predict the service life of bridge on Korea highway.