• Title/Summary/Keyword: 콘크리트 구조물 보수

Search Result 366, Processing Time 0.024 seconds

Development of the Impulse Response Measurement System for Non-destructive Test of Slab Structure (판상 구조물 비파괴검사를 위한 충격응답시험기의 개발)

  • Chung, Hojoon;Lee, Heuisoon;Oh, Seokhoon;Song, Sung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.1
    • /
    • pp.45-52
    • /
    • 2013
  • We developed a Impulse Response Measurement System, including hardware system and data analysis software, for non-destructive test of slab structure. And, we carried out impulse response measurements on the pavement to test performance of the system. In the field test, the developed system measured impulse response stably and showed parameters immediately. Test results showed that dynamic stiffness and average mobility varies significantly depending on the characteristics of the pavement materials. Some data showed anomalous values those reflect variations in pavement itself or subsurface ground. Developed system gives informations of conditions of slab structure easily and quickly. So, 2-D monitoring with the system will be helpful in maintaining various slab structures.

Analysis of Failure Behavior of FRP Rebar Reinforced Concrete Slab based on FRP Reinforced Ratio (FRP 보강근비에 따른 FRP 보강 콘크리트 슬래브의 파괴거동 분석)

  • Jang, Nag-Seop;Kim, Young-Hwan;Oh, Hong-Seob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.173-181
    • /
    • 2021
  • Reinforced concrete structures are exposed to various environments, resulting in reinforcement corrosion due to moisture and ions penetration. Reinforced concrete corrosion causes a decrease in the durability performance of reinforced concrete structures. One solution to mitigate such issues is using FRP rebars, which offer several advantages such as high tensile strength, corrosion resistance, and light-weight than conventional rebars, in reinforced concrete instead of conventional steel rebars. The FRP rebar used should be examined at the limit state because FRP reinforced concrete has linear behavior until its fracture and can generate excessive deflection due to the low elastic modulus. It should be considered while designing FRP reinforced concrete for flexure. In the ultimate limit state, the flexural strength of FRP reinforced concrete as per ACI 440.1R is significantly lower than the flexural strength by applying both the environmental reduction and strength reduction factors accounting for the material uncertainty of FRP rebar. Therefore, in this study, the experimental results were compared with the deflection of the proposed effective moment of inertia referring to the local and international standards. The experimental results of GFRP and BFRP reinforced concrete were compared with the flexural strength as determined by ACI 440.1R and Fib bulletin 40. The flexural strength obtained by the experimental results was more similar to that obtained by Fib bulletin 40 than ACI 440.1R. The flexural strength of ACI 440.1R was conservatively evaluated in the tension-controlled section.

Adhesive Properties of High Flowable SBR-modified Mortar for Concrete Patching Material Dependent on Surface Water Ratio of Concrete Substrate (콘크리트 피착체의 표면수율에 따른 단면복구용 고유동성 SBR 개질 모르타르의 부착특성)

  • Do, Jeong Yun;Kim, Doo Kie
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.124-134
    • /
    • 2013
  • This study investigated the effect of surface water on concrete substrate on adhesive strength in tension of very high flowable SBR-modified cement mortar. The specimens were prepared with proportionally mixing SBR latex, ordinary portland cement, silica sand, superplasticizer and viscosity enhancing agent. Polymer cement ratio (P/C) were 10, 20, 30, 50 and 75% and the weight ratio of fine aggregate to cement were 1:1 and 1:3. The specimens obtained with different P/C and C:F were characterized by unit weight, flow test, crack resistance and adhesion test. After basic tests, two mixtures of P/C=20% and 30% in case of C:F=1:1, and one mixture of P/C=50% in case of C:F=1:3 were selected, respectively. These three selected specimens were studied about the effect of surface water evenly sprayed on concrete substrate by a amount of 0, 0.006, 0.012, 0.017, 0.024g per unit area ($cm^2$) of concrete substrate surface The results show that surface water on concrete substrate increases the adhesive strength in tension of high flowable SBR-modified cement mortar and improve the flowability compared to the non-sprayed case.

A Study on Control of Sealing Robot for Cracks of Concrete Surface (콘크리트 표면 균열 실링을 위한 로봇의 제어 방법에 관한 연구)

  • Cho, Cheol-Joo;Lim, Kye-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.481-491
    • /
    • 2015
  • Since the crack in the surface of the concrete acts as the main reason influencing the life span of the structure, regular inspections and maintenance are required. The sealing required for maintenance of the concrete surface is a method of repairing the crack in the surface in the beginning, and is effective in preventing additional cracks and expansion that occurs with time. However, sealing on large sized structures such as tall buildings or bottom parts of bridges are difficult to ensure safety of the workers due to inadequate working environments. Due to this reason, the importance of the need for sealing automation for the maintenance of large sized concrete structures is emerging. This study proposes two control methods to apply robot systems to the sealing of cracks on the bottom parts of concrete bridges. First is the method of automatically tracking the trajectory of cracks. The robot gets the trajectory of the cracks using video information obtained from cameras. Comparing the previous several points and new point, the next point can be estimated. Thus, the trajectory of the crack can be tracked automatically. The other method is sealing by maintaining steady force to the contacting surface. The concrete surface exposed to an external environment for a long time gets an irregular roughness. If robots are able to carry out sealing while maintaining a steady contact force on these rough surfaces, complete equal sealing can be maintained. In order to maintain this equal force, a force control method using impedance is proposed. This paper introduces two developed control methods to apply to sealing robots, and conducts a Lab Test and Field Test after applying to a robot. Based on the test results, opinions on the possibilities of field application of the robot applied with the control methods are presented.

A Study on the Decision of Influence Range of External Temperature in the Tunnel Using Thermal Camera (열화상카메라를 활용한 외부온도의 터널내 영향범위 산정방법 연구)

  • Lee, Yu-Seok;Lee, Tea-Jong;Park, Gwang-Rim;Oh, Young-Seok;Cha, Cheol-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.136-143
    • /
    • 2010
  • There are three parts of tunnel which are influenced by outside temperature, entrance, exit and vent. These parts showed different tendency of deterioration(very rapid deterioration speed, wide range of defects, etc) compared with last parts of tunnel. Therefore, it needs to have different points of view when civil engineers analyze the defects on these parts and apply the retrofit or rehabilitation methods for them. However, when we conduct maintenance works, precise inspection and precise safety diagnosis, these defects had been neglected because those were considered as unimportant defects and caused from temporary weather and temperature change. In this study, two urban tunnels were analyzed to decide the range of tunnel which are influenced by outside temperature using a thermal camera, and to find out the causes of defects on these parts. From the results, the main points of maintenance were presented.

A Prediction of the Long-Term Deflection of RC Beams Externally Bonded with CFRP and GFRP (CFRP와 GFRP로 외부 부착된 철근콘크리트보의 장기 처짐 예측)

  • Kim, Sung-Hu;Kim, Kwang-Soo;Han, Kyoung-Bong;Song, Seul-Ki;Park, Sun-Kyu
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.765-772
    • /
    • 2008
  • For RC structures, long-term deformation occurs due to the inherent characteristics, which are creep and shrinkage. In terms of serviceability, it is important to limit deflection caused by the deformation to the allowable deflection. In the recent years, various repair and strengthening methods have been used to improve performance of the existing RC structures. One of the typical methods is FRP externally bonded method (EBR). Fiber reinforced polymer (FRP) has been used worldwide as repair and strengthening materials due to its superior properties. Besides, it has to offer improved strengthening performance not only under instantaneous load but sustained load. Therefore, accurate prediction method of deflection for the RC members externally bonded with FRP under sustained load is required. In this paper, three beams were fabricated. Two beams were externally strengthened with one of CFRP plate and GFRP plate respectively. Total three beams were superimposed under sustained load of 25 kN. During 470 days, deflections at midspan were obtained. Moreover, creep coefficients and shrinkage strains were calculated by using ACI-209 code and CEB-FIP code. In order to predict the deflection of the beams, EMM, AEMM, Branson's method and Mayer's method were used. Through the experiment, it was found that the specimen with CFRP plate has the most flexural capacity and Mayer's method is the most precise method to predict total long-term deflections.

A Studt on the Physical and Chemical Properties of Epoxy Resin in RC Structures (RC 구조물 보수용 에폭시 레진의 물리.화학적 특성 고찰)

  • 김도겸;유영찬;이장화;박승범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.571-578
    • /
    • 1997
  • In the repair and repair works, epoxy resins are widely used as repair materials. The successful concrete repairs and retrofit works depends on the quality of the repair and retrofit materials. Although many materials for the repairs and retrofit have been developed in many contries, information on the repair methods are somewhat limited. Futhermore, the repairs and retrofit methods are also largely dependent on those froms in other developed contries, it is necessary to initiate rather fundamental repair-related research. The purpose of this study is to investigate th physical and mechanical properties of epoxy resin which is commonly used in repairing concrte crack in RC structures. The basic physical properties such as specific gravity, gel point and shrinkage ratio as well as the mechanical properties such ad the tensile and compressive strength, elastic modulus were acquired by the standard test method (KS code). For the test results, the great deviations of physical and mechanical properties among the test materials were discovered and is, therefore, recommended that careful attentions should be give in selecting the epoxy resin by considering the characteristics of the repair materials and repair works.

  • PDF

A Study on Technology of Waterproofing of the Concrete Structure Which Used Soft FRP Resin and Square Groove Cutting Technique (연질 FRP 수지와 정방형 홈 컷팅 기술을 이용한 콘크리트 구조물의 방수기술에 관한 연구)

  • Lee, Hyung-Jun;Choi, Sung-Min;Kim, Sung-Sik;Ahn, Sang-Ku;Cho, Ah-Hyung;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.597-600
    • /
    • 2008
  • In this study the reason which researches the feature of the exposure type waterproofing it uses the technique of the soft FRP it uses the soft unsaturated polyester and the square groove cutting technique with respects and solves the interface separate problem because of the rigid FRP it is used with the repairs and retrofit materials it is caused by in adhesion of concrete insufficiency. The feature of this technique was the dispersion and the reinforcement of the fatigue stress due to the integration behavior and the reinforcement due to the glass-fibre of the concrete due to the soft FRP resin and, it investigated the crack appearance confrontation of concrete and the cohesion stability of the concrete due to the square groove cutting technique with importance. The result of research when it applies the soft FRP with the exposure type waterproofing, is judged with the fact that it will be able to expect a bulge resistance confrontation and creak confrontation ability and cohesion stability improvement.

  • PDF

Tensile Bond Characteristics between Underwater Coating Materials and Concrete Substrate (수중코팅제와 콘크리트 모재 간의 인장 부착 특성)

  • Kim, Min Ook;Jeong, Yeonung;Kang, Sung-Hoon;Moon, Juhyuk;Yi, Jin-Hak
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.6
    • /
    • pp.298-305
    • /
    • 2018
  • In this study, we investigated the tensile bond characteristics of underwater coating materials, in order to obtain useful information in support of repair work for marine and coastal concrete structures. Test variables included type of underwater coating, surface conditions of the concrete substrate, and environmental conditions. Pull-off tensile bond strength was measured at 24 h after applying underwater coatings to concrete substrates, in compliance with the procedures specified in ASTM C1583. Failure modes (coating, interface, and parent concrete) for each coating were identified through visual inspection, and comparisons were made based on measured bond strength. The tensile bond strength decreased underwater compared to that under dry conditions, while no significant effect of surface roughness on the measured bond strength was observed in underwater tests. Key aspects that need to be considered regarding selection and use of underwater coating materials for marine and coastal concrete structures were discussed.

Performance Evaluation of Chloride and Sulfate Removal using Anion Exchange Resin in Saturated Ca(OH)2 Solutions (음이온 교환수지를 이용한 포화 수산화칼슘 수용액 내 염소이온 및 황산이온 제거 특성 평가)

  • Lee, Yun-Su;Chen, Zheng-Xin;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.146-154
    • /
    • 2017
  • Recently, self-healing concrete has been researched as maintenance and repair of concrete structures are important challenges we face. This paper focused on possibility of ion exchange resin as a novelty material directly and actively controlling harmful ions of concrete, whereas most self-healing concrete researches have been focused on methods to automatically filling and repairing internal crack of concrete. Because equilibrium properties between ion exchange resin and harmful ion is important before design of cement mixing proportion, it was conducted to remove chloride or sulfate in saturated $Ca(OH)_2$ solutions containing NaCl or $Na_2SO_4$. The removal performance was analyzed using kinetic equation and isothermal equation. Consequently, the removal properties of anion exchange resin were relatively more dependent on pseudo second reaction equation and Langmuir equation than pseudo first reaction equation and Freundlich equation. And it was concluded that each chloride and sulfate can be removed to the maximum 1068 ppm and 1314 ppm.