• Title/Summary/Keyword: 콘크리트특성

Search Result 5,560, Processing Time 0.028 seconds

The Long-Term Strength and the Workability of High-Strength Fly Ash Concrete (고가도 플라이애쉬 콘크리트의 장기 강도 특성에 관한 연구)

  • 김진근;박연동;성근열
    • Magazine of the Korea Concrete Institute
    • /
    • v.3 no.4
    • /
    • pp.107-115
    • /
    • 1991
  • An investigation for the short-term and long-term compressive strength and workability characteristics for the high strength fly ash concrete was carried out when fly ash was used in high strength concrete. Selected test variables were compressive strength with 6 levels(2 levels of normal strength and 4 levels of high strength) and fly ash contents with 4 levels(O, 10, 20, 30%). For the evaluation of slump loss, four other mixes were added. As the result. the concrete containing 10% fly ash developed higher strength before 28 days than that of control concrete. With increasing of fly ash content, the slump of normal strength concrete was gradually decreased and quantity of superplasticizer for high strength concrete was also increased to keep constant slump.

Bond Strength Properties of Latex Modified Concrete (라텍스 개질 콘크리트의 부착강도 특성)

  • 윤경구;이주형;최상릉;김기헌
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.507-515
    • /
    • 2001
  • Significant improvements in bond strength between new and existing concrete can be achieved through the modification of the new concrete by latex. This study focuses on the investigation of bond strength of latex modified concrete. Pull-out bond test and uniaxial direct tensile bond test are adopted for evaluating the adhesion characteristics of latex modified concrete to conventional concrete substrate. The main experimental variables are test methods, latex-cement ratio, surface preparations and moisture levels. The results are as follows; The increase of latex-cement ratio substantially improves the adhesion between latex modified concrete and substrate. The effects of surface preparation at substrate into the bonding of latex modified concrete are quite different according to the conditions of surfaces. Thus, an adequate surface preparations are essential for good bond strength. Because the moisture level of the substrate may be critical to achieving bond, optimum moisture condition for a conventional concrete has evaluated in this study. The saturated condition of surface is the most appropriate moisture level among the considered, followed by dry condition and wet condition.

Experimental Study on the Infilling Characteristics of CFT Column Infilled by Pumping-Up Below (하부압입공법에 의한 콘크리트 충전강관(CFT)기둥의 충전특성에 관한 실험적 연구)

  • Kim, Myoung Mo;Jeon, Sang Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.375-383
    • /
    • 2002
  • To evaluate the applicability of the construction method involving infilling CFT columns by pumping-up, a trial construction was done using 6 actual size test samples. The 12.8m-high test samples were similar to a four-story building scale. The pumping-up level was controlled at 12m. The test used two types of high performance concrete with $450kgf/cm^2$ standard design strength, and a concrete pump which is used domestically. The pressure changes in pipes or pump as well as the changes in concrete characteristics were measured during construction. in order to evaluate applicability. After the concrete hardened, the column was dismantled. The filled state of the concrete, concrete strength distribution according to column height, etc., were checked to evaluate the quality of the concrete, From the results, some basic data which characterize the pumping-up pressure were suggested. Also, the strength of hardened concrete as well as the filled state were proven to be acceptable ranges.

Slump and Mechanical Properties of Hybrid Steel-PVA Fiber Reinforced Concrete (강섬유와 PVA 섬유로 하이브리드 보강된 콘크리트의 슬럼프 및 역학적 특성)

  • Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.651-658
    • /
    • 2010
  • Sixteen concrete mixes reinforced with hybrid steel-polybinyl alcohol (PVA) fibers and a control concrete mix with no fiber were tested in order to examine the effect of the micro and macro fibers on the slump and different mechanical properties of concrete. Main variables investigated were length and volume fraction of steel and PVA fibers. The measured mechanical properties of hybrid fiber reinforced concrete were analyzed using the fiber reinforcing index and compared with those recorded from monolithic steel or PVA fiber reinforced concrete. The initial slump of hybrid fiber reinforced concrete decreased with the increase of the aspect ratio and the volume fraction of fibers. In addition, splitting tensile strength, modui of rupture and elasticity, and flexural toughness index of concrete increased with the increase of the fiber reinforcement index. Modulus of rupture and flexural toughness index of hybrid fiber reinforced concrete were higher than those of monolithic fiber reinforced concrete, though the total volume fraction of hybrid fibers was lower than that of monolithic fiber. For enhancing the flexural toughness index of hybrid fiber reinforced concrete, using the steel fiber of 60 mm length was more effective than using the steel fibers combined with 60 mm and 30 mm lengths.

A Study on the Sound Absolution Properties of Porous Concrete by Recycled Aggregate Contents and Target Void Ratio (재생골재의 혼입률과 목표공극률에 따른 포러스콘크리트의 흡음특성에 관한 연구)

  • Park Seung-Bum;Seo Dae-Seuk;Lee Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.541-548
    • /
    • 2004
  • This study peformed an evaluation of the physical and mechanical properties and sound absorption characteristics of porous concrete according to the target void ratio and content of the recycled aggregate in order to reduce the noise generated in roads, railroads, residential areas and downtown areas and effectively utilize the recycled waste concrete aggregate generated as a byproduct of construction. The test results demonstrated that the difference between the target void ratio and the actual measured void ratio was less than 1.7% and that the tendency of the compression strength was to reduce rapidly when the target void ratio and the content of the recycled aggregate exceeded 25% and 50%, respectively. In addition, the sound absorption characteristics of the porous concrete using recycled waste concrete aggregate showed that the NRC was the highest at the target void ratio of 25% and the content of the recycled aggregate had very little influence on the NRC. Therefore, when considering the compression strength and the sound absorption characteristics of porous concrete, the proper target void ratio and the content of the recycled waste concrete aggregate are thought to be 25% and 50%, respectively

Fundamental Characteristics of Concrete for Nuclear Power Plant Using Crushed Sand (부순모래 사용에 따른 원전 구조물용 콘크리트의 기초적 특성)

  • Park, Sung-Hak;Kim, Kyung-Hwan;Choi, Byung-Keol;Choi, Yun-Wang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.168-176
    • /
    • 2017
  • This study, as a research for using crushed sand as a fine aggregate of concrete for nuclear structures, we improved the performance of impact crusher in the existing crushed sand production process and adjusted grain size to conform to ASTM C 33 The shape and grain size characteristics of a crushed sand were examined and concrete was prepared according to the substitution ratio of the sand to investigate the properties of fresh concrete and hardened concrete. The experimental results show that most of the concrete characteristics are equivalent to those of concrete using only heavy sand. However, when the substitution rate of steel sand exceeds 50%, the amount of air, compressive strength and tensile strength are somewhat reduced.

Freezing-and-Thawing Resistance and Strain Characteristics of Recycled Concrete (재생콘크리트의 동결융해저항성과 변형특성)

  • 김광우;이봉학;도영수
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.4
    • /
    • pp.115-122
    • /
    • 1992
  • 폐쇄 폐콘크리트를 재활용한 재생콘크리트의 강도특성을 천연골재를 사용한 일반콘크리트와 비교하였다. 동결융해 처리수의 압축강도와 3점휨 재하시험하의 변형율을 측정하였다. 재생콘크리트는 동결융해 처리 후 압축강도 보존율이 더 높았다. 재생콘크리트는 또한 높은 변형율과 처짐에 민감함을 보였으나 파괴와 관련된 다른 성질들은 일반콘크리트와 유사하거나 더 좋은 것으로 나타났다. 그러므로 폐콘크리트를 구조용 콘크리트 제조에 재 사용이 가능할 것으로 보여진다. 그러나 실제 사용을 위하여는 콘크리트에 있어서 중요한 성질인 압축강도가 더 증진되어야 하며 최대 변형율도 보다 자세히 점검되어야 한다.

An Experimental Study on Flexural Properties of SC(Steel Plate Concrete) Beam Structure with Reinforced Concrete Joint (철근 콘크리트 구조와 강판 콘크리트 구조(Steel Plate Concrete) 이질접합부를 가진 보의 휨 하중 특성에 관한 실험연구)

  • Lee, Kyung-Jin;Hahm, Kyung-Won;Park, Dong-Soo;Kim, Woo-Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.5
    • /
    • pp.455-463
    • /
    • 2010
  • This paper describes the experimental study on the mechanical characteristics of a steel plate-reinforced concrete joint. As an alternative reinforced concrete structure, the SC modular construction method is widely used and studied in the field ofindustrial facility field. However, the structure characteristics of RC and SC joint are not yet studied completely. In this paper, the beam-type construction joint of RC and SC walls was made to simulate the application of SC module to the large RC structure. Also, an out-of-plane loading was applied to the test specimen in order to evaluate flexural strength and structural properties of the beam-type RC-SC joint.

A Study on the Fracture Characteristicsof Crushed Sand Concrete and River Sand Concrete (강모래 및 부순모래 콘크리트의 파괴특성에 관한 연구)

  • 김진근;이칠성
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.129-136
    • /
    • 1995
  • Thls research Includes est~mat~ons of the relat~on ktween the strength of concrete and the fracture energy for river sand concrete and crushed sand concrete using the wedge sphtting test method. Furthermore the fracture energy and the characteristic length of two types of concrete were compared and d~scussed. Fracture behaviors of crushed sand concrete and natural sand concrete had the similar trend in fracture characteristics. The fracture energy was increased with the increase of compressive strength in the strength range of 20-60MPa, but was not increased for the concrete more than 6OM.Pa of compressive strength.

Micremechanics-based Evaluation of Elastic Modulus of Concrete considering Interfacial Transition Zone (천이영역을 고려한 콘크리트 탄성계수의 미시역학적 추정)

  • 송하원;조호진;변근주
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.2
    • /
    • pp.99-107
    • /
    • 1998
  • 콘크리트는 일반적으로 수회시멘트풀과 골재로 이루어진 이상의 복합체이지만 미시적으로는 수화시멘트풀과 골재, 그리고 천이영역으로 이루어진 삼상의 복합체이다. 수화시멘트풀과 골재 사이에서 형성되는 천이영역은 국부적으로 공극률이 높으므로 콘크리트의 강성과 강도에 많은 영향을 끼친다. 본 논문에서는 이러한 천이영역의 특성을 고려하여 콘크리트의 탄성계수를 추정하기 위해 이원 삼중 내포물 모델을 제안하였다. 제안된 모델에 의한 탄성계수의 추정결과는 실험결과와 비교하여 잘 일치하였으며 제안된 모델은 실험적으로 구하기 힘든 천이영역의 특성을 구하는데 사용될 수 있다.