• 제목/요약/키워드: 콘크리트구조물

검색결과 3,802건 처리시간 0.033초

수화열 발생인자가 지하철 콘크리트 구조물의 내구설계에 미치는 영향 (Effect of the factor developing the Heat of Hydration on Durability Design in the Subway Concrete Structure)

  • 임영수;김은겸;성기한
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1131-1137
    • /
    • 2004
  • With the recent continuous expansion of subways, newly created subways tend to have lower locations and wider sections. Furthermore. since box structures and evacuating tunnels are classified into a category of mass-concrete. the thermal-stress, emitted from the inside. causes cracks to structures from the inception of constructing. In this paper, thermal-stress analysis and durability evaluation of box structure were carried out to investigate relationship between durability and parameter causing the heat of hydration. Through the examination, this paper tries to find out satisfactory solutions to regulated thermal crack and ensure the required duration period. The results of this paper showed that to control thermal crack and guarantee the required duration period it was more effective to use low-heat-portland cement and moderateheat-portland cement. As cement volume due to reduction of water-cement ratio increased, the possibility of thermal cracks occurrence increased but results of durability evaluation was different depending on evaluation method. The results showed that the appropriate water-cement ratio to control the heat of hydration and satisfy the required durability was $45\∼55\%$. And it was showed that during placement of concrete blocks ambient temperature affect the heat of hydration. thermal crack and long-term durability largely and when concrete was placed at low temperature to control thermal crack. it need to try to guarantee the required duration period. Henceforth, by studying not only internal and external conditions, such as the relative humidity and the unit weight. but also methods, to evaluate durability, in accordance with domestic situations, more reasonable design of durability should be achieved.

  • PDF

현장평판재하시험에 의한 현장타설형 팽이말뚝기초의 지지력산정 (Estimation of Bearing Capacity for In-Situ Top-Base Method by Field Experimental Plate Load Test)

  • 신은철;안민희
    • 한국지반신소재학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2011
  • 연약지반상에 구조물을 축조하게 되면 지반의 지지력 부족, 과대침하량 및 측방변형과 같은 문제점이 발생한다. 팽이말뚝기초공법은 지지력이 다소 부족한 지반에 팽이형 콘크리트 파일을 연약지반기초에 사용하여 지지력 증가와 침하억제, 부등침하방지 등의 효과를 도모하는 연약지반 표면 처리용 강성매트공법이며, 공사비 절감 등의 경제적인 효과와 공사기간 단축, 공사 중 소음 등으로 인한 민원 차단 등의 시공에 따른 편의성을 확보할 수 있다. 따라서 본 연구에서는 현장평판재하시험을 통하여 연약지반상의 현장타설형 팽이말뚝기초의 지지력을 산출하였다. 평판재하시험 분석결과를 통해 기존 연구 및 설계에서 적용하고 있는 제안식과 비교분석하여 현장타설형 팽이말뚝기초를 기초지반에 적용할 시 기초의 합리적인 범위를 산정하여 향후의 설계에 그 결과를 활용하고자 한다.

PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구 (Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab)

  • 이두성;배정;최헌;민인기
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.465-473
    • /
    • 2013
  • 본 연구에서는 터널에서 발생되는 화재로부터 구조물을 보호하기 위해 내화패널이 부착된 프리캐스트 PSC 슬래브의 내화성능을 조사하기 위해 내화실험이 수행되었다. 내화실험은 독일의 RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) 화재시간-온도곡선을 적용하여 내화성능을 평가하는 것으로 하였다. ITA(2004)에서 제시하는 기준에 따라 내화성능 시험을 수행한 결과, 콘크리트의 손상을 판단하는 위치인 t=0mm의 최대온도는 $367^{\circ}C$로서 손상한계온도 $380^{\circ}C$(ITA 2004)이하였으며, 철근의 손상을 판단하는 위치인 t=25mm의 최대온도는 $239^{\circ}C$로서 손상 한계온도인 $250^{\circ}C$이하로 나타났다. 실험결과로부터, 25mm두께의 내화패널이 부착된 프리스트레스 슬래브 시험체는 내화성능을 가진 것으로 입증되었다.

LPG 충전소의 BLEVE 현상에 따른 피해효과 분석 (A Study on Damge Effect from Boiling Liquid Expanding Vapor Explosion(BLEVE) of LPG Charging Facility)

  • 노삼규;김태환;함은구
    • 한국가스학회지
    • /
    • 제3권3호
    • /
    • pp.45-50
    • /
    • 1999
  • 도심지내에 위치한 부천 LPG충전소 사고 조사를 통하여 가장 피해효과가 큰 탱크로리 폭발에 따른 결과를 분석하였다. 분석범위는 BLEVE 현상에 의한 방출열과 과압이 충전소주변에 위치한 구조물이나 인체에 미치는 영향을 대상으로, 실제 현장조사를 통하여 수집된 피해결과와 이론적인 모델(PHAST-Process Hazad Analysis Sortware Tools) 분석 결과를 비교하였다. 부천 LPG 충전소 폭발 사고의 피해효과는 방출열의 경우 두 가지 모두 큰 차이를 보이지 않았으나, 과압의 경우, 실제 피해는 이론적 모델분석결과의 약 $15\%$정도에 해당하는 축소된 거리에서 나타났다. 또한, 충전소 인근에 위치한 구조물에 대한 피해효과는 부분적으로 과압에 의한 균열 및 붕괴 현상보다는 열 효과에 의한 콘크리트 강도 저하와 성상변화가 크게 나타났다.

  • PDF

광촉매 콘크리트 도로 구조물의 효율적 시공방법에 대한 실험적 연구 (An Experimental Study for the Construction of Photocatalytic Method Concrete Road Structure)

  • 홍성재;이승우
    • 한국도로학회논문집
    • /
    • 제15권6호
    • /
    • pp.1-9
    • /
    • 2013
  • PURPOSES : About 35% of air pollutant is occurred from road transport. NOx is the primary pollutant. Recently, the importance of NOx removal has arisen in the world. $TiO_2$ is very efficient for removing NOx by photocatalytic reaction. The mechanism of removing NOx is the reaction of photocatalysis and solar energy. Therefore, $TiO_2$ in concrete need to be contacted with solar radiation to be activated. In general, $TiO_2$ concrete are produced by substitute $TiO_2$ as a part of concrete binder. However, 90% of $TiO_2$ in the photocatalysis can not contacted with the pollutant in the air and solar radiation. Coating and penetration method are attempted as the alternative of mixing method in order to locate $TiO_2$ to the surface of structure. METHODS : The goal of this study was to attempt to locate $TiO_2$ to the surface of concrete, so we can use the concrete in pavement construction. The distribution of $TiO_2$ along the depth were confirmed by basing on the comparison of $TiO_2$ compare by using the EDAX(Energy Dispersive X-ray Spectroscopy). RESULTS : $TiO_2$ were distributed within 3mm from concrete surface. This distribution of $TiO_2$ is desirable, since the $TiO_2$ induce photocatalysis are located to where they can be contacted with the air pollutant and solar radiation. CONCLUSIONS : Nano size $TiO_2$ is easily penetration in the top 3mm of concrete surface. By the penetration $TiO_2$ concrete can be produced with the use of only 10% of $TiO_2$, by comparing the mixing types.

조적벽의 전단강도를 고려한 철근콘크리트골조의 비탄성 거동 (Inelastic Behavior of Reinforced Concrete Frame Structure with Shear Strength of Masonry Wall)

  • 윤태호;강경수
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.4216-4222
    • /
    • 2011
  • 본 연구는 조적 끼움벽을 고려하지 않은 기존 학교건물의 비탄성 거동과 조적 끼움벽을 고려한 기존 학교 건물의 거동특성을 비교 검토하였다. 해석 결과와 실험 결과를 비교했을 때 하중-변위 곡선과 소성힌지 분포상태에서 유사함을 확인할 수 있었다. 따라서 조적 끼움벽을 고려한 비선형 정적해석의 유효성을 검증하였다. 골조내부가 전부 조적벽으로 채워진 경우 조적벽체의 영향에 의하여 초기 강성과 강도가 증가하고 항복 전까지는 근사한 거동을 보여주며 항복이후에는 변형이 커질수록 오차가 증가하며, 골조높이의 2/3 높이가 조적벽으로 채워진 경우 초기 강성과 항복강도가 단순골조에 비하여 약간 크게 나타나고 있으며, 조적벽체의 균열이 발생한 이후에는 급격히 강도가 저하되고 있다. 골조높이의 1/3 높이가 조적벽으로 채워진 경우 초기 강성과 항복강도가 단순골조와 비슷하며 항복점은 오히려 단순 골조의 항복점보다 저하되나, 최대강도는 단순 골조와 유사하다. Pushover 해석에 의한 하중-변위 관계곡선과 실제 실험에 의한 하중-변위 관계곡선을 비교해 보면 항복 전까지는 근사한 거동을 보여주며 항복이후에는 변형이 커질수록 오차가 증가하나 실제 구조물에서는 변형의 한계가 존재하므로 해석모델로서 유용하게 사용할 수 있다.

3층 철근콘크리트 전단벽 구조물의 지진응답해석 (Earthquake Response Analysis for Three-Story Building with Reinforced Concrete Shear Walls)

  • 이인규;이은행;김재민
    • 한국지진공학회논문집
    • /
    • 제25권3호
    • /
    • pp.103-110
    • /
    • 2021
  • A shake table test is conducted for the three-story reinforced concrete building structure using 0.28 g, 0.5 g, 0.75 g, and 1.0 g of seismic input motions based on the Gyeongju earthquake. Computational efforts are made in parallel to explore the mechanical details in the structure. For engineering practice, the elastic modulus of concrete and rebar in the dynamic analysis is reduced to 38% and 50%, respectively, to calibrate the structure's natural frequencies. The engineering approach to the reduced modulus of elasticity is believed to be due to the inability to specify the flexibility of the actual boundary conditions. This aspect may lead to disadvantages of nonlinear dynamic analysis that can distort local stress and strain relationships. The initial elastic modulus can be applied directly without the so-called engineering adjustment with infinite element models with spring and spring-dashpot boundary conditions. This has the advantage of imposing the system flexibility of the structure on the sub-boundary conditions of springs and damping devices to control its sensitivity in a serial arrangement. This can reflect the flexibility of realistic boundary conditions and the effects of system damping (such as the gap between a concrete footing and shake table, loosening of steel anchors, etc.) in scalar quantities. However, these spring and dashpot coefficients can only be coordinated based on experimental results, making it challenging to select the coefficients in-prior to perform an experimental test.

콘크리트 구조물에 사용되는 개량아스팔트 시트와 아스팔트 매스틱을 복합화한 방수공법의 누유안정성 평가방법 개발 (Development of Oil Leakage Stability Evaluation for Composite Aterproofing Methods using Asphalt Mastic and Modified Asphalt Sheet in Concrete Structure)

  • 박진상;김동범;박완구;김병일;오상근
    • 한국건축시공학회지
    • /
    • 제19권1호
    • /
    • pp.19-29
    • /
    • 2019
  • 본 연구에서는 공동주택 지하주차장 상부슬래브 등 주로 수평부에 적용되는 아스팔트 매스틱 도막재의 누유하자 원인을 바탕으로 제품의 누유안정성 확보 여부를 평가할 수 있는 평가방법을 개발 및 제시하였다. 본 연구에서 제시한 평가방법의 신뢰성을 검증하기 위하여 실제 현장에서 누유 발생 이력이 있는 3개 제품을 대상으로 누유안정성 평가를 진행하였으며, 진행 결과, 실제 발생하는 누유하자의 재연이 가능한 것으로 확인되었다. 재연성에 대한 정량적 검증을 위해 평가 중에 발생한 누유 시료를 채취하여 회분(Filler)함량을 측정한 결과, 정상시료 대비 최대 약 64%가 저하된 것을 확인하였는데, 이는 선행연구에서 규명한 누유원인과 일치하는 결과로 확인하여, 평가방법의 신뢰성이 검증되었다 할 수 있다.

페로니켈슬래그 잔골재의 바닥용 건조모르타르 적용성 평가 (Applicability of Ferro-nickel Slag Sand for Dry Mortar in Floor)

  • 조봉석;김원기;황인성;구경모
    • 한국건축시공학회지
    • /
    • 제19권2호
    • /
    • pp.105-112
    • /
    • 2019
  • 페로니켈슬래그 잔골재는 천연 잔골재와 유사한 특성이 있어 국내 외적으로 콘크리트 구조물에 사용되고 있으나 그 용도와 연구의 영역이 한정적이다. 이에 본 연구에서는 FNS의 활용성 확대와 모르타르제품의 성능개선을 목적으로 바닥용 건조모르타르에 대한 FNS의 적용성을 검토하고자 하였다. 실험 결과, FNS는 흡수율이 낮고 구형의 입형이며 표면이 유리질 피막의 특성이 있어 모르타르의 플로을 향상시켰다. 또한 골재 자체의 높은 강성은 몰탈 압축강도의 향상 및 수축저감 효과를 나타내어 균열저감 등의 품질향상에 기여할 것으로 판단된다. 뿐만 아니라 천연 잔골재를 사용한 모르타르와 비교하여 FNS를 적용하는 경우 동등수준 이상의 충격음 차단성능을 확보할 수 있었다.

전문건설업 유형별 효율성 분석 연구 (A Study on the Efficiency Analysis of Specialty Construction Industry Type)

  • 김예정;유동영;박선구
    • 한국콘텐츠학회논문지
    • /
    • 제19권5호
    • /
    • pp.64-73
    • /
    • 2019
  • 본 연구는 전문건설업체의 경쟁력을 평가하기 위해 DEA모형을 활용하여 효율성을 분석하였다. 분석대상기업은 전문건설업 상장업체와 외감업체로 2010년부터 2017년까지 연속자료가 존재하는 300개 기업을 대상으로 하였다. 특히, 전문건설업 유형별 효율성을 비교, 분석하여 그 시사점을 찾는데 중점을 두었다. 의미 있는 분석결과는 다음과 같다. 첫째, 전문건설업체의 효율성은 전반적으로 종합건설업 등과 비교하면 효율성 값이 낮게 분석되었다. 둘째, 전문건설업 유형별 효율성은 시설물축조 및 해체 전문공사업이 가장 높게 나타났다. 이는 해당 업종인 철근 콘크리트공사업, 비계 구조물해체공사업 등이 전문건설업 내에서 상대적으로 효율적임을 의미한다. 셋째, 전문건설업 효율성은 건설경기에 영향을 받는다. 건설경기가 확장국면에 있을 때는 효율성 값이 높고, 수축국면에서는 낮은 효율성 값을 나타내었다. 마지막으로 규모수익성 분석에서 전문건설업은 DRS로 분석되는 경우가 가장 많았다. 이는 규모 확대보다 규모 축소를 통해 기업의 효율성을 높이는 것이 바람직하다는 것을 의미한다.