• Title/Summary/Keyword: 코일 채널

Search Result 51, Processing Time 0.033 seconds

Derivation of Parameters for Loudspeaker with Frequency Dependent Terms and Discussion for Estimation Methods (라우드스피커 주파수 종속 매개변수 유도 및 규명법 비교)

  • Park, Seok-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.276-285
    • /
    • 2007
  • In this paper it was discussed and compared measured loudspeaker impedance curve with ones reconstructed by TS parameters estimated using four kinds of parameter estimation methods developed in frequency domain. Frequency dependent parameters were introduced and derived using least square error minimization technique. For known dynamic mass TS parameter estimation methods were reviewed and also proved non-uniqueness of these parameters by simulation method. Minimum phase transformation was adopted to derive phase information from magnitude of loudspeaker electrical impedance curve measured by one channel analyzer.

A Study on Indirect Attachment Method of Compensation Materials to Increase Signal Intensity in Magnetic Resonance Imaging (자기공명영상검사 시 신호강도를 높이기 위한 보상물질의 간접부착 방식에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.437-442
    • /
    • 2017
  • Previously, studies on compensation material to increase the signal intensity have been conducted which does not affect the reading of images. However, the compensation material has a concern on patient infection as it is attached directly on the skin. Therefore, in this study, we tested an indirect attachment of the compensation material as an alternative method of the direct attachment. The silicon compensation material was fabricated in the form of a cylindrical bar and attached to each element of the 8 channel head coil. Then the signal intensities of the water phantom pre and post application of the silicon were measured. T1 and T2-weighted images were acquired using an 8-channel head coil and a 3.0T superconducting MRI. Signal intensities were measured by using an image measuring program. Paired t-test was used to verify if there were significant differences. The signal intensity before application of the silicon was significantly increased by 3.39% and 2.62% in T1 and T2 weighted images, respectively. Although the indirect attachment method had a limitation to completely replace the existing method, it was considered to be useful in patients with infectious diseases such as diabetic complications since it had a meaningful improvement in signal intensity based on the filling factor increase.

Asynchronous IR-UWB ranging system (비동기 IR-UWB 레인징 시스템)

  • Choi, You-Shin;Yang, Hoon-Gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.3
    • /
    • pp.587-594
    • /
    • 2010
  • In this paper, we propose an asynchronous IR-UWB ranging system based on the two-way ranging protocol. The periodic pulse sequence is used to measure a distance between two devices. At the receiver, a received signal is first transformed into a frequency-domain signal using an analog correlator bank and digital signal processing is followed in the frequency-domain. This make it possible for the system to use an ADC with a conversion speed of pulse rate. The proposed algorithm at the receiver side includes a peak detection procedure using mutipath channel compensation and matched filtering, and retransmits a pulse sequence synchronized with the detected peak. The validity of the proposed algorithm is verified from simulation results where the CM1 channel is assumed.

Output Ccharacteristics of XeCl Excimer Laser Excited by Transeverse-Electron-Beam (횡방향 전자빔여기 XeCl 엑시머 레이저의 출력특성)

  • 류한용;이주희;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.386-393
    • /
    • 1994
  • We have investigated output characteristics of XeCI excimer laser excited by transeverse electronbeam. We used e-beam output of 880 kV, 21 kA (70 ns, FWHM) and controlled current density of e-beam by pulsed magnetic coil (4.7 kG) which was fabricated around an e-beam diode (A-K gap is 21 mm) and laser chamber. We have obtained 35 J (4 atm) of e-beam deposition energy injected into laser media. The deposition energy was converted from an exposure area of Radcolor film and rising pressure of gas media which is measured by pressure jump method. The excited volume of $320cm^{3}$ was calculated. The maximum efficiency of 1.7% was obtained with the mixing ratio of HCllXe/Ar==0.2/ 6.3/93.5% and total pressure of 3 atm. Also laser output energy and specific energy were obtained 0.52 J and 1.7 J/I, respectively. For the analysis of experimental results we have developed computer simulation code. From the good agreements with the results of experiment and simulation we could theoretically explain the XeCI* formation channel. relaxation channel, and absorption channel of 308 nm.308 nm.

  • PDF

A Study on the Performance Characteristics of a Chirp RTLS over Wireless Channel with Gaussian Noise (가우시안 잡음이 존재하는 무선채널에서 Chirp RTLS 시스템의 성능 특성에 관한 연구)

  • Kang, Byeong-Gwon
    • Journal of Digital Convergence
    • /
    • v.11 no.7
    • /
    • pp.201-207
    • /
    • 2013
  • The chirp signaling has been mainly used in radar systems due to its good correlation characteristics, and nowadays it is applied to real time locating system(RTLS). The RTLS with chirp signaling was chosen as a standard such as ISO/IEC 24730-5 and IEEE 802.15.4a. In this paper, the performance of a real time locating system with chirp signaling was evaluated and simulated with relative distance error rates. We considered three cases of S/I = -30[dB], -20[dB], and -10[dB] with Rician factor K=10 and K=20. The performance was enhanced with K factor improvement by 25%, 27% and 50% for respective three cases of S/I. As results, in case of S/I < -20[dB], the minimum signal power is required for performance improvement even though the line of sight component is helpful. And also, in case of S/I ${\geq}$ -20[dB], as the line of sight component is stronger the better performance is obtained.

Design of MRI Spectrometer Using 1 Giga-FLOPS DSP (1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • Purpose : In order to overcome limitations in the existing conventional spectrometer, a new spectrometer with advanced functionalities is designed and implemented. Materials and Methods : We designed a spectrometer using the TMS320C6701 DSP capable of 1 giga floating point operations per second (GFLOPS). The spectrometer can generate continuously varying complicate gradient waveforms by real-time calculation, and select image plane interactively. The designed spectrometer is composed of two parts: one is DSP-based digital control part, and the other is analog part generating gradient and RF waveforms, and performing demodulation of the received RF signal. Each recover board can measure 4 channel FID signals simultaneously for parallel imaging, and provides fast reconstruction using the high speed DSP. Results : The developed spectrometer was installed on a 1.5 Tesla whole body MRI system, and performance was tested by various methods. The accurate phase control required in digital modulation and demodulation was tested, and multi-channel acquisition was examined with phase-array coil imaging. Superior image quality is obtained by the developed spectrometer compared to existing commercial spectrometer especially in the fast spin echo images. Conclusion : Interactive control of the selection planes and real-time generation of gradient waveforms are important functions required for advanced imaging such as spiral scan cardiac imaging. Multi-channel acquisition is also highly demanding for parallel imaging. In this paper a spectrometer having such functionalities is designed and developed using the TMS320C6701 DSP having 1 GFLOPS computational power. Accurate phase control was achieved by the digital modulation and demodulation techniques. Superior image qualities are obtained by the developed spectrometer for various imaging techniques including FSE, GE, and angiography compared to those obtained by the existing commercial spectrometer.

  • PDF

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.

The Performance Analysis of DS/SSMA BPSK Correlation Receivers in Electric Power Line Channel (전력선 채널에서의 DS/SSMA BPSK 코릴레이션 수신기 성능에 관한 연구)

  • Kang, Byeong-Kwon;Cho, Chang-Gil;Cho, Kwan;Lee, Jae-Kyeong;Whang, Keum-Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.9
    • /
    • pp.972-981
    • /
    • 1992
  • In this paper, the performance of linear and hard-limiting correlation receivers for DS/SSMA BPSK power line communication system is analyzed. Strong impulsive noise of power line is modeled with Chan's noise model, and the performance of both receivers is analyzed in terms of parameters such as ratio of power spectrum density of impulsive noise to that background noise, ratio in impulsive noise width th that of data bit, and interarrival time of impulsive noise. And also multiple access capacity is evaluated with Gaussian approximation of multiple access interference. The results of this analysis reveal that the performance of linear correlation receiver is superior to that of hard-limiting correlation receiver when $N_1/N_b$ is small and is close to 1. But the BER and the multiple access capacity of hard-limiting correlation receiver becomes better in comparison with linear correlation receiver as $N_1/N_b$ increases.

  • PDF

Study on Implementation of a Digital Frequency Discriminator using 4 channel Delay line (4채널 지연선로를 이용한 디지털 주파수 판별기 구현에 관한 연구)

  • Kook, Chan-Ho;Kwon, Ik-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.512-515
    • /
    • 2010
  • SIGINT(SIGnal INTelligence) includes several parameters intercepted by measurement and analysis of the RF(Radio frequency) signal from free space. One of the important parameters is frequency information. Expecially, in order to perform instantaneous frequency measurement of Radar and Missile seeker's RF signals, we use dedicated RF modules as a DFD(Digital Frequency Discriminator) to provide frequency information by measurement of the relative phase difference between signals via intended RF delay lines. It must measure and provide realtime based frequency information on short pulsed RF signal up to 100 nSec or less. This document proposes Ultra wideband DFD consisted of a RF input section of Wideband 4 channel RF delay line and correlator, a digital processing section to measure and provide frequency information from I/Q signal, and a frequency calibration section. Also, it will show design suitability based on test results measured under test condition of very short input pulse signals.

  • PDF

500 W급 고리형 홀추력기의 자기장 구조에 따른 추력 특성 연구

  • Lee, Seung-Hun;Kim, Ho-Rak;Kim, Jun-Beom;Im, Yu-Bong;Choe, Won-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.202-202
    • /
    • 2016
  • 홀 플라즈마 엔진은 인공위성의 궤도유지 및 자세제어 등의 임무수행이나 우주선의 심우주 활용에 있어 필수적인 핵심 우주 부품이다. 홀추력기 연구개발의 최근 큰 관심사는 추력기의 장시간 운전성 확보 및 방전효율 향상이다. 최근 고리형 홀추력기에서 방전 영역 내 플라즈마와 유전체 벽 간의 충돌을 줄임으로써 전극 손상 및 전자온도 손실을 감소시키기 위한 연구가 활발히 진행되고 있다. 특히 전자석 코일을 활용해 방전 채널 벽면과 평행한 방향의 자기장을 형성하여 플라즈마와 유전체 벽 간의 상호작용을 감소시키는 연구들이 소개되고 있으며, 이러한 방법을 자기차폐(magnetic shielding)라 한다. 본 연구에서는 자기차폐 개념이 적용된 방전 소모전력 500 W급 고리형 홀추력기의 방전 및 추력 발생 특성을 연구하였다. 자기장구조 제어를 통해 유전체 벽과 플라즈마 간 상호작용을 감소시킨 결과, 500 V 수준의 방전 전압에서도 유전체 벽에서의 이차전자 발생에 의한 방전전류의 급격한 증가없이 안정적인 방전이 가능하였으며, 이러한 방전 형태는 기존의 자기차폐 개념이 적용되지 않은 일반 고리형 홀 추력기에서 구현하기 어려운 방전 상태이다. 추력기의 자기장 구조 최적화 조건에서 제논 가스 방전을 통해 얻은 최대 추력은 $22{\pm}1mN$, 비추력 $2200{\pm}70s$, 양극효율 $51{\pm}2%$로 매우 우수한 성능을 보여 주었다

  • PDF