• Title/Summary/Keyword: 케이스

Search Result 1,111, Processing Time 0.024 seconds

Model-Based Design of Operational Management System for Integrated Wireless Communication Network of Korean Railway Systems (철도 통합무선망 운영관리 시스템의 모델기반 설계에 관한 연구)

  • Kim, Changwon;Kim, Kyung-Hee;Lee, Young-Hoon;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3071-3080
    • /
    • 2015
  • The increased demand on the transport of both passengers and goods through rail systems implies higher traffic intensity and congestion on the railways, resulting in greater likelihood of accidents and also degraded passenger services. To cope with the issues, development of an integrated communication network for rails has attracted great deal of attention lately. GSM-R is such an example developed in Europe, which seems to have restrictions in providing various communication services due to network speed limit. For the reason, an LTE-based approach is under study in Korea. After the network development, operation management of the network is necessary. Design of operation management systems has been studied little and thus is the objective of this paper. To do so, a conceptual design has been carried out based on model-based approach. Specifically, a context model has first been created using the use case diagram. Then, SysML models of operational scenarios were developed for the management system. The SysML models have alternatively been expressed as EFFBD models to simulate and verify them. Consequently, the result of the conceptual system design for the operation management of the integrated wireless network is expected to be used as a basis for the detailed design later.

A Quality Stability Estimation of Shock-absorber Tube for automatic drawer (자동서랍함용 완충기 튜브의 품질 안정성 예측)

  • Son, Jae-Hwan;Kim, Young-Suk;Han, Chang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.2919-2924
    • /
    • 2011
  • The automatic drawer is used to absorb the movement shock and adjust its velocity when it opens and closes. The tube in shock-absorber is the cylindrical case which surrounds its parts and is made of acetal. The purpose of this study is to determine the quality stability of the tube in the shock-absorber in injection molding process. The tube which had been manufactured in the process with 4 cavity cooling unit was used. In this study, the analysis and test are carried out to determine its quality stability. Which are the quality analysis with numerical simulation and performance tests of the tube compared with one of foreign make. It is calculated that the injection press is 87.6 MPa and the deflections in X, Y, Z directions are ranged in 0.07~1.00 mm. When the researched tube is compared with the foreign made tube, the maximum bending compressive load is 231 kgf higher, average axial compressive load is 0.05 kgf higher, and the roughness(Ra) on the inner surface is $0.02\;{\mu}m$. lower. In the result, it is known that the quality of researched tube in injection mold process is stable and its performance is superior.

Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery (이차전지의 상태 감시 및 수명 예측 알고리즘 개발)

  • Park, Jaebeom;Kim, Byeonggi;Song, Seokhwan;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.369-377
    • /
    • 2013
  • This paper deals with the state of charge(SOC) and life cycle evaluation algorithm for lead-acid battery, which is essential factor of the electric vehicle(EV) and the stabilization of renewable energy in the smart grid. In order to perform the effective operation of the lead-acid battery, SOC and life cycle evaluation algorithm is required. Specific gravity with the change of electrolyte temperature inside battery case should be obtained to evaluate the SOC of lead-acid battery, however it is difficult to measure the electrolyte temperature of sealed type lead-acid battery. To overcome this problem, this paper proposes the equation of thermal transmission to compensate internal temperature of the lead-acid battery. Also, it is difficult to exactly evaluate the life cycle of battery, depending on the operation conditions of lead-acid battery such as charging and discharging state, self discharging rate and environmental issue. In order to solve the problem, this paper presents the concept for gravity accumulation of charge and discharge cycle, which is the value converted at $20^{\circ}C$. By using the proposed algorithm, this paper propose the test device based on the Labview software. The simulation results show that it is a practical tool for the maintenance of lead-acid battery in the field of industry.

Applicability of Bi-directional Load Test for Evaluating Bearing Capacity of Helical Piles (헬리컬 파일의 지지력 산정을 위한 양방향 재하시험의 적용성 평가)

  • Lee, Dongseop;Na, Kyunguk;Lee, Wonje;Kim, Hyung-Nam;Choi, Hangseok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.77-85
    • /
    • 2014
  • The helical pile has become popular with some constructional advantages because relatively compact equipment is needed for installing helical piles. However, field loading tests for estimating the bearing capacity of helical piles have drawbacks that the required dead load should be as much as the operation load, and reaction piles or anchors are required. In this paper, the bi-directional load test without necessity of reaction piles and loading frames was applied to the helical pile, and the load-settlement curves of the helical piles were measured. The bi-directional load test was performed in two separate stages with the aid of a special hydraulic cylinder whose diameter is equal to that of the pile shaft. In the first stage, the hydraulic cylinder is assembled immediately above the bottom helix plate, and the end bearing capacity of the helical pile is measured. In the second stage, the hydraulic cylinder is assembled above the top helix plate, and the skin friction of the helical pile is measured. The pile loading-test program was carried out for the two different helical piles with the shaft diameter of 89 mm and 114 mm, respectively. However, the configuration of helix plates is identical with three helix plates of 450-, 350-, 200- mm diameter. Results of the bi-directional load test were verified by the conventional static pile loading test. As a result, the bearing capacity estimated by the bi-directional load test is in good agreement with the result of the conventional pile loading test.

A study on the correlation between the degree of elasticity uniformity and the dynamic performance in the overhead contact lines (전차선로 탄성도 불균일율과 동역학적 성능과의 관계에 대한 연구)

  • Park, Sa-Hoon;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.502-502
    • /
    • 2007
  • A catenary system should be designed to have an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity uniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate the degree of elasticity uniformity of a catenary according to the literature survey. The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for various different configurations of catenary systems using a beam element based FEM program. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity uniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF

The Legal Issues of Private Investigation Service in WTO/FTA System : Study of South Korea (WTO/ FTA 체제에서 민간조사업의 법적문제)

  • Ko, Ji-Hoon;Park, Hyeon-Ho
    • Korean Security Journal
    • /
    • no.27
    • /
    • pp.161-195
    • /
    • 2011
  • As crimes have increased to an extent that the police cannot cope with, there have been continuous discussions for the introduction of Private Investigation (hereafter PI) in Korea. However, attempts to legislate for the introduction of PI have failed every time PI bills for the introduction of PI were proposed. This was fundamentally because arguments both for and against the introduction of PI were sharply divided depending on the priorities. However, regardless of those clash of views, an apparent need for the legislation of PI service has arisen. As Korea opens its service market to other countries through GATS and FTAs, currently existing domestic PI law has been found to be inconsistent with international agreements such as GATS and KOREA-US(KORUS) FTA. This paper found that the Act on Usage and Protection of Credit Information which regulates PI service is inconsistent with the Article 12.4(a)(i) and (iii) of KORUS FTA and the Article 7.11 and the Article 7.13 of KOREA-EU FTA. If Korea does not modify the existing laws and establish new laws in relation to PI, such inconsistencies could lead to international trade disputes which could amount to billions of dollars. In this regard, the passage of the PI bill is necessary.

  • PDF

Injection-Acupuncture Combined by Conventional Treatment in Canine Demodicosis : Case Report (개 모낭충증에 있어서 약침과 기존 치료의 병용 : 증례 보고)

  • Jun, Hyung-Kyou;Han, Ji-Won;Oh, Hyun-Wook;Lee, Hyun-Hwa;Park, Bae-Kun;Park, Seong-Jun;Cho, Sung-Whan;Kim, Duck-Hwan
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.432-436
    • /
    • 2007
  • Therapeutic effect by injection-AP with antibiotics plus conventional treatment was investigated to establish a new treatment method for canine demodicosis. Three patients diagnosed into canine demodicosis were used in the present study. Injection-AP with enrofloxacin (5 mg/kg, twice a week) was made into the acupoints such as Fei Shu(BL13), Wei Zhong (BL40), Da Zhui (GV14), Zu San Li (ST36), He Gu (LI04), Qu Chi (LI11) and Sang Yin jiao(SP06) for 5 weeks. Further, they were additionally received with conventional treatments including injection of ivermectin (0.5 mg/kg, twice a week, SC) and 0.05% amitraz rinse (twice a week) for 5 weeks. The clinical symptoms (pruritus, excoriation, erythema and alopecia) were much improved by injection-AP therapy plus conventional treatment, compared by those of pre-treatment. Case 1 became to normal after 4 weeks, Case 2 became to mild after 5 weeks and Case 3 became to normal after 5 weeks. Total WBC revealed decreasing tendency with treatment in all cases, however, N/L ratios didn't show regular pattern of change with treatment. Notable changes were not histopathogically found in skin lesions of Case 1 and Case 3 except Case 2 with mild change after 5 weeks treatment, compared by those of pre-treatment, respectively. In conclusion, the present patients were cases with canine demodicosis which revealed favorable therapeutic response by injection-AP with antibiotics plus conventional treatment.

Surgical Management of Urethral Plugs in a Male Shih-Tzu Dog (수컷 시츄견에서 발생한 유레쓰랄 플러그의 수술적 관리)

  • Hong, Su-Bin;Kim, Min-Kyung;Kim, Tae-Hwan;Kim, Keun-Yung;Kim, Hyo-Yeon;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.519-522
    • /
    • 2015
  • A 6-year-old castrated male Shih-Tzu was admitted to the Gyeongsang Animal Medical Center with hematuria and vomiting. Serum chemistry indicated increases in blood urea nitrogen and creatinine values. Radiography showed radiopaque materials attached to the ventralis of the inner bladder wall. Penile urethra also was filled with radiopaque materials. Ultrasonography revealed bilateral perineal effusion in the kidney, thinned bladder wall, and materials with acoustic shadowing at the caudal extremity of the os penis. Because urination was not identified by urinary obstruction, cystocentesis was performed. Hematuria was diagnosed by urinalysis, but clear crystals were not identified. Owing to failure of securing patency to the bladder using retrohydropropulsion, cystotomy and urethrotomy with retrohydropropulsion were performed. In this report, we describe the clinical and radiographic findings of urethral plugs in a male Shih-Tzu dog, wherein the urethral plugs were treated successfully with hydropropulsion, cystotomy, and urethrotomy. It provides an option for the treatment of urethral plugs in a dog.

A Classification and Extraction Method of Object Structure Patterns for Framework Hotspot Testing (프레임워크 가변부위 시험을 위한 객체 구조 패턴의 분류 및 추출 방법)

  • Kim, Jang-Rae;Jeon, Tae-Woong
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.7
    • /
    • pp.465-475
    • /
    • 2002
  • An object-oriented framework supports efficient component-based software development by providing a flexible architecture that can be decomposed into easily modifiable and composable classes. Object-oriented frameworks require thorough testing as they are intended to be reused repeatedly In developing numerous applications. Furthermore, additional testing is needed each time the framework is modified and extended for reuse. To test a framework, it must be instantiated into a complete, executable system. It is, however, practically impossible to test a framework exhaustively against all kinds of framework instantiations, as possible systems into which a framework can be configured are infinitely diverse. If we can classify possible configurations of a framework into a finite number of groups so that all configurations of a group have the same structural or behavioral characteristics, we can effectively cover all significant test cases for the framework testing by choosing a representative configuration from each group. This paper proposes a systematic method of classifying object structures of a framework hotspot and extracting structural test patterns from them. This paper also presents how we can select an instance of object structure from each extracted test pattern for use in the frameworks hotspot testing. This method is useful for selection of optimal test cases and systematic construction of executable test target.

The Effect of Medication in the Patients with Bee-Sting (약물투여가 벌자상환자에게 미치는 효과)

  • Cho, Byung-Jun;Moon, Soo-Jae;Kim, Seon-Rye
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.350-356
    • /
    • 2015
  • The purpose of this study is effect factors of Pre-Hospital Medication in the Patients with Bee-Sting. This study is to identify the necessity of using epinephrine in prehospital stage from the perspective of early management of anaphylaxis following a bee sting. Methods: Patients suffering from a bee sting who used the 119 rescue between 2013 from 119 center data were included. Age, sex, month of injury, time factors, vital signs, medication, signs, distance factors, presence of cardiac arrest, AVPU triage by EMT were extracted. The severity of bee sting injury was divided into mild, moderate, and severe according to the presenting symptoms and signs. Results: The severe patients treated by using oxygen, IV, ECG, Medication. Anaphylaxis is a serious allergic reaction of rapid onset that may lead to death. One of Anaphylaxis patients lived by using epinephrine. Most patients collapsed at the scene of mount. Bee sting injuries occurred primarily during summer to the farmer. Nine patients collapsed at the scene. Bee sting injuries occurred primarily from June to October. Conclusion: The primary treatment for anaphylaxis is epinephrine. Epinephrine in pre-hospital stage is factors of essential for patients. Also epinephrine will permit to be equipped in the EMT-P and use of epinephrine by law.