• Title/Summary/Keyword: 컴퓨터 단층검사 3D

Search Result 18, Processing Time 0.024 seconds

A Convergence Study on the Reduction of Noise and Streak Artifacts in Shoulder Joint Computed Tomography (어깨관절 컴퓨터 단층 검사 시 발생하는 노이즈 및 줄무늬 인공물 감소에 대한 융합 연구)

  • Jang, Hyon-Chol;Cho, Pyong-Kon
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.7
    • /
    • pp.189-194
    • /
    • 2021
  • The purpose of this study was to investigate the effect of reducing noise and streaking artefacts by applying the Boost3D algorithm in the case of noise and streaking artifacts generated during computed tomography of the shoulder joint. A phantom study using a thoracic phantom including shoulder joint and clinical evaluation were conducted through shoulder joint images of 35 patients who underwent computed tomography of the shoulder joint from September 2020 to October 2020. The evaluation was divided into groups before and after the application of the Boost3D algorithm, and the noise values, signal to noise ratio, and mean to standard deviation ratio values were analyzed. Both noise values and mean to standard deviation ratio values analyzed in phantom image evaluation and clinical image evaluation were statistically significantly lower in the group after Boost3D was applied (p<0.05). Through this study, it was found that noise and streak artifacts were reduced through the application of Boost3D, and the mean to standard deviation ratio was high, which can be judged as an excellent image. If the Boost3D algorithm is used for computed tomography of the shoulder joint, it is thought that excellent images can be obtained with reduced noise and streaking artifacts that may occur in the shoulder joint area.

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

A Measurement Method for Cervical Neural Foraminal Stenosis Ratio using 3-dimensional CT (3차원 컴퓨터단층촬영상을 이용한 신경공 협착률 측정방법)

  • Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.975-980
    • /
    • 2020
  • Cervical neural foraminal stenosis is a very common spinal disease that affects a relatively large number of people of all ages. However, since imaging methods that quantitatively provide neural foraminal stenosis are lacking, this study attempts to present quantitative measurement results by reconstructing 3D computed tomography images. Using a 3D reconstruction software, the surrounding bones were removed, including the spinous process, transverse process, and lamina of the cervical spine so that the neural foramen were well observed. Using Image J, a region of interest including the neural foramen area of the 3D image was set, and the number of pixels of the neural foramen area was measured. The neural foramen area was calculated by multiplying the number of measured pixels by the pixel size. In order to measure the widest area of the neural foramen, it was measured between 40-50 degrees in the opposite direction and 15-20 degrees toward the head. The measured cervical neural foramen area showed consistent measurement values. The largest measured area of the right neural foramen C5-6 was 12.21 ㎟, and after 2 years, the area was measured to be 9.95 ㎟, indicating that 18% stenosis had progressed. Since 3D reconstruction using axial CT scan images, no additional radiation exposure is required, and the area of stenosis can be objectively presented. In addition, it is good to explain to patients with neural stenosis while viewing 3D images, and it is considered a good method to be used in the evaluation of the progression of stenosis and post-operative evaluation.

3D Modeling of Cerebral Hemorrhage using Gradient Vector Flow (기울기 벡터 플로우를 이용한 뇌출혈의 3차원 모델링)

  • Seok-Yoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.231-237
    • /
    • 2024
  • Brain injury causes persistent disability in survivors, and epidural hematoma(EDH) and subdural hematoma (SDH) resulting from cerebral hemorrhage can be considered one of the major clinical diseases. In this study, we attempted to automatically segment and hematomas due to cerebral hemorrhage in three dimensions based on computed tomography(CT) images. An improved GVF(gradient vector flow) algorithm was implemented for automatic segmentation of hematoma. After calculating and repeating the gradient vector from the image, automatic segmentation was performed and a 3D model was created using the segmentation coordinates. As a result of the experiment, accurate segmentation of the boundaries of the hematoma was successful. The results were found to be good even in border areas and thin hematoma areas, and the intensity, direction of spread, and area of the hematoma could be known in various directions through the 3D model. It is believed that the planar information and 3D model of the cerebral hemorrhage area developed in this study can be used as auxiliary diagnostic data for medical staff.

Assessment of Aging Effects on Computed Tomographic Glomerular Filtration Rate in Dogs (개에서 연령에 따른 동적 컴퓨터단층촬영을 이용한 사구체여과율의 평가)

  • Chang, Jin-Hwa;Kim, Hwan-Cheol;Choi, Ji-Young;Choi, Ho-Jung;Lee, Hee-Chun;Chang, Dong-Woo;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.130-133
    • /
    • 2012
  • The purpose of this study is to assess the relationship between glomerular filtration rate (GFR) and age by using dynamic computed tomography (CT) and Patlak plot analysis in dogs. Fifteen dogs were used in this study. CT-GFR study was performed under general anesthesia using propofol and isoflurane. 1 ml/kg dosage of 300 mgI/ml iohexol was administered at a rate of 3 ml/s during GFR measurement. CT-GFR was determined with a single-slice dynamic acquisition and Patlak plot analysis. The individual and global GFR values were calculated to plasma clearance per body weight (ml/min/kg). Bodyweight ($mean{\pm}SD$) ranged from 2.0 to 5.7 kg ($3.31{\pm}1.13$ kg). Age ranged from 3 years to 13 years old ($7.14{\pm}3.30$). $Mean{\pm}SD$ creatinine ($0.53{\pm}0.34 $mg/dl), phosphorus ($4.1{\pm}1.2$ mg/dL), and albumin ($3.3{\pm}0.3$ mg/dL) concentrations and urine protein-to-creatinine ratios (all ratios were < 0.5) were within reference ranges. Abdominal ultrasonography revealed small-sized renal calculi, mineralization, or renal cyst at eight dogs. The global CT-GFR ranges shown in this study was 2.57 to 6.60 ml/min/kg. In this study, there was no trend toward weight-adjusted CT-GFR with increasing age. We found no relationships between age-related kidney dysfunction in fifteen dogs. Small-sized renal calculi or cysts did not affect renal function in this study. However, it is thought that a large sample size may have been required to document an age effect.

Evaluation of the Applicability of PET/CT Phantom as a 3D Printing Material (PET/CT 팬텀의 3D 프린팅 소재 적용 가능성 평가)

  • Lee, Ju-young;Kim, Ji-Hyeon;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.423-431
    • /
    • 2022
  • The purpose of this study is to present objective information in applying 3D printing technology for PET/CT (Positron Emission Tomography/Computed Tomography) performance evaluation and use it as a basic research that can be applied to various purposes in the future. Phantoms were manufactured with step wedge of ABS(Acrylonitrile Butadiene Styrene) and ACR(Acrylic acid) material. The counts for each ROI(Region of Interest) were analyzed through image acquisition in PET/CT. And the variation rate of counts and CNR(Contrast Noise Ratio) was evaluated. In the counts analysis, the effect of thickness occurred. In addition, in the variation rate analysis, the thickness setting of steps wedge 4 to 5 levels should be considered first. These results minimize quantitative and qualitative changes in the phantom manufactured based on 3D printing, and enable more stable PET/CT performance evaluation. Based on 3D printing in PET/CT, various phantoms are expected to be produced in the future. If the characteristics of each material are considered and applied through the basic research such as this research, the result of the phantom manufactured through 3D printing can be more meaningful and will be used in a wide range.

Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type) (대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성)

  • Kwak, Yeong-Gon;Kim, Chong-Yeal;Cho, Yeong-Gi
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.313-321
    • /
    • 2015
  • To minimize CT examination for Hip FAI diagnosis and operation plan. also, whether the MRI 3D images can replace Hip Clock face image was evaluated when performing Hip FAI MRI by using additional 3D image. This study analyzed Hip MRI and 3D Hip CT images of 31 patients in this hospital. For the purpose of evaluating the images, one orthopedic surgeon and one radiology specialist reconstructed Clock face, at MR and CT modality, by superior 12 o'clock, labrum front 3 o'clock, and the other side 9 o'clock, centering on Hip joint articular transverse ligament 6 o'clock. Afterwards, by the Likert Scale 5 point scale (independent t-test p<0.005), this study evaluated the check-up of A. retinacular vessel, B. head neck junction at 11 o'clock, A. Epiphyseal line, B. Cam lesion at 12 o'clock, and Cam lesion, Posterior Cam lesion at 1,2,3 and 4 o'clock. As for the verification of reliability among observers, this study verified coincidence by Cohen's weighted Kappa verification. As a result of Likert scale for the purpose of qualitative evaluation about the image, 11 o'clock A. retinacular vessel MR average was $3.69{\pm}1.0$ and CT average was $2.8{\pm}0.78$. B. head neck juncton didn't have a difference between two observers (p <0.416). 12 o'clock A. Epiphyseal line MR average was $3.54{\pm}1.00$ and CT average was $4.5{\pm}0.62$(p<0.000). B. Cam lesion didn't have a difference between two observers (p <0.532). 1,2,3,4 Cam lesion and Posterior Cam lesion were not statistically significant (p <0.656, p <0.658). As a result of weighted Kappa verification, 11 o'clock A.retinacular vessel CT K value was 0.663 and the lowest conformity. As a result of coincidence evaluation on respective item, a very high result was drawn, and two observers showed high reliability.

Validity of midsagittal reference planes constructed in 3D CT images (전산화단층사진을 이용한 3차원 영상에서 정중시상기준평면 설정에 관한 연구)

  • Jeon, Ye-Na;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.182-191
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the validity of midsagittal reference (MSR) planes constructed in maxillofacial 3D images. Methods: Maxillofacial computed tomography (CT) images were obtained in 36 normal occlusion individuals who did not have apparent facial asymmetry, and 3D images were reconstructed using a computer software. Six MSR planes (Cg-ANS-Ba, Cg-ANS-Op, Cg-PNS-Ba, Cg-PNS-OP, FH${\perp}$(Cg, Ba), FH${\perp}$(Cg, Op)) were constructed using the landmarks located in the midsagittal area of the maxillofacial structure, such as Cg, ANS, PNS, Ba and Op, and FH plane constructed with Po and Or. The six pairs of landmarks (Z, Fr, Fs, Zy, Mx, Ms), which represent right and left symmetry in the maxillofacial structure, were selected. Statistically significant differences of the right and the left measurements were examined through t-test, and the difference of the right and the left measurement was compared among the six MSR planes. Results: The distances from the right and the left landmarks in each pair to each MSR plane did not show a statistically significant difference. The reproducibility of the landmark identification was excellent. Conclusion: All the six planes constructed in this study can be used as a MSR plane in maxillofacial 3D analysis, particularly, the planes including Cg and ANS.

Is routine screening examination necessary for detecting thromboembolism in childhood nephrotic syndrome? (소아 신증후군 환자에서 혈전증 검색을 위해screening 검사가 필요한가?)

  • Kim, Mun Sub;Koo, Ja Wook;Kim, Soung Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.7
    • /
    • pp.736-741
    • /
    • 2008
  • Purpose : The incidence of thromboembolic episodes in children with nephrotic syndrome (NS) is low; however, these episodes are often severe. Moreover, both pulmonary thromboembolism (PTE) and renal vein thrombosis (RVT) rarely show clinical symptoms. This study was performed to determine the benefits of routine screening in the detection of thrombosis in childhood NS. Methods : Among 62 children with nephrotic syndrome, a total of 54 children (43 males, 11 females) were included in this study. When the patients experienced their first NS episode, we performed renal Doppler ultrasonography in order to detect RVT. To rule out the possibility of PTE, a lung perfusion scan was performed. Computed tomographic (CT) pulmonary angiography was recommended to patients who showed possible signs of PTE. All patients were evaluated for clinical signs of thrombosis, biochemical indicators of renal disease, as well as clotting and thrombotic parameters. Results : RVT or related clinical symptoms were not observed in any children. Based on the findings of the lung perfusion scans, 15 patients (27.8%) were observed with as a high probability of PTE. We were able to perform a CT pulmonary angiography only on 12 patients, and 5 patients were diagnosed with PTE (prevalence 8.1%). The serum fibrinogen level in the group with PTE was significantly higher ($776.7{\pm}382.4mg/dL$, P<0.05) than that in the group without PTE, and other parameters were not significantly different between each group. Conclusion : Further studies are required for clarifying the role of renal Doppler ultrasonography for the detection of RVT in NS. Children with NS who developed non-specific respiratory symptoms should be evaluated for the diagnosis of PTE. In the management of NS, a lung perfusion scan should be performed at the time of the initial episode of NS regardless of the pulmonary symptoms, since patients having PTE are either often asymptomatic, or present with nonspecific symptoms.

A Case of Lung Involvement Showing Multiple Lung Cysts in Primary Sjögren's Syndrome (다발성 폐 낭종을 보인 쇼그렌 증후군의 폐 침범 1예)

  • Kim, Ji Yon;Hwang, Hyun Gyu;Choi, Jae Sung;Seo, Ki Hyun;Kim, Yong Hoon;Oh, Mee Hye;Na, Ju Ock
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.3
    • /
    • pp.230-235
    • /
    • 2008
  • We described herein the first case of primary $Sj{\ddot{o}}gren^{\prime}s$ syndrome in Korea which presented with multiple cysts caused by only peribronchiolar lymphocytic infiltration, a rare pulmonary manifestation in $Sj{\ddot{o}}gren^{\prime}s$ syndrome, and was confirmed by surgical lung biopsy. A brief review of the literature has been included.