• Title/Summary/Keyword: 캐드자료

Search Result 14, Processing Time 0.02 seconds

Evaluating usability of and satisfaction with two types of dental CAD software (두 종류 치과 임플란트 캐드 소프트웨어의 사용자 편의성 및 만족도 비교)

  • Kim, Seong-Min;Lee, Wan-Sun;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.11-19
    • /
    • 2019
  • Purpose: This study evaluated the usability of and satisfaction with two types of computer-aided design (CAD) software among users who had experience with dental implant CAD software and those who did not. Materials and Methods: Dental technicians (n = 20) who had previous experience with dental implant CAD Software and students from the College of Dentistry (n = 12) who had never designed implant custom abutments were asked to evaluate two types of CAD Software, Exocad and Deltanine. In addition, the participants were asked to fill out a structured questionnaire (Section 1: Entering basic information and retrieving files; Section 2: Setting conditions before abutment design; Section 3: Setting abutment design; and Section 4: Overall satisfaction). For the statistical analysis of the collected data, Mann-Whitney U test was used (${\alpha}=.05$). Results: The ease of design and satisfaction with the implant CAD Software, evaluated with respect to 21 statements divided into four Stages, were significantly higher for Exocad in both groups for Secion 1. For Sections 2 and 3, participants with experience evaluated Deltanine to be significantly better. For Section 4, both groups evaluated Exocad Software to be better. Conclusion: Overall, the Exocad Software was evaluated as having better usability and offering greater satisfaction. However, in terms of performance in the core of the design process, i.e. Sections 2 and 3, Deltanine was rated higher by the experienced users. Thus, if the user interface design parts are supplemented, Deltanine CAD Software could be put to a wider use in clinics.

The Construction of Digital Close Range Photogrammetry System Integrated With CAD for Education (수치영상을 이용한 사면지반 계측시스템 개발(1) - 캐드의 연계를 통한 DCRP 교육용 운용시스템 구축 -)

  • 배상호;주영은
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.4
    • /
    • pp.399-404
    • /
    • 2002
  • In this study, it was intended to present solution for learners to understand and utilize photogrammetry more easily using economic medium except expensive measuring equipment. For this, 3D point data was analysed by generating event to stereo image on monitor, and input to CAD system automatically. so, real time vector editing and drawing with coordinates measurement were possible. The system was verified, and the monitoring for real construction was performed. so, it is expected to be utilized as a practical use software in related fields.

A Web-based Virtual Space Modeling Using 2D CAD Data (2차원 캐드자료를 이용한 웹기반 가상공간 모델링)

  • Lee, Jang-Kyung;Lee, Sung-Kee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11a
    • /
    • pp.443-446
    • /
    • 2002
  • 인터넷과 컴퓨터 기술이 발달함에 따라 가상공간에 대한 관심은 커져가고 있다. 그러나 가상공간을 생성하는 작업은 많은 시간과 노력이 필요하다. 그래서 가상공간 모델링에 관련된 연구들이 많이 이루어지고 있다. 본 논문에서는 2차원 CAD 데이터로부터 가상공간을 모델링하는 방법을 제시한다. CAD 파일에서 2차원 지형정보를 추출하여 웹에서 볼 수 있는 3차원 가상공간을 생성한다. 가상공간생성 과정은 전처리, 데이터 추출, 모델생성, 렌더링으로 이루어진다. 전처리는 CAD 파일에서 도로경계선을 분리하며 데이터 추출은 등고선, 도로경계선, 건물 정보를 CAD 파일로부터 추출하는 과정이다. 모델 생성은 추출한 지형정보들을 이용해서 3차원 공간모형 데이터를 생성하는 과정이다. 본 논문에서 제시한 방법은 실세계에 근접한 가상공간을 생성하며 가상공간을 생성하는데 드는 시간과 노력을 줄일 수 있다.

  • PDF

Plant Configuration System by using Electrical Document Management System (EDM을 이용한 발전소 정보관리시스템 개발)

  • 이숙형;박찬국
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2000.04a
    • /
    • pp.275-280
    • /
    • 2000
  • 설계 및 엔지니어링 단계에서 설계정보 전자문서관리 시스템을 통한 지식 수집과 축적의 방법을 제시한다. EDM을 이용한 클라이언트/서버 형태 및 웹 버변의 데이터베이스 인터페이스를 설계하며 이를 통한 발전소 정보의 접그니, 저장, 버젼별로 관리 및 이관/복구/백업하도록 하는 시스템 구현방법에 대해 기술한다. 또한 3차원 캐드 뷰어와 연동된 자료의 효율적인 관리방법에 대해 설명한다.

  • PDF

Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication (총의치 제작을 위한 무치악 디지털 모형의 정확도 평가)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.393-398
    • /
    • 2015
  • One of the most critical causes in determining the clinical outcomes of dental prostheses is the validity of models. However, studies that evaluated validity of digital models are few. The objectives of this study were to evaluate validity of edentulous digital models for full denture fabrication. Twenty stone models (edentulous model) were manufactured and scanned by dental blue light emitting diode scanner. Twenty digital models were manufactured. Six linear distances (inter-canine distance, inter-molar distance, two dental arch lengths (right, left), two diagonal of dental arch lengths (right, left) were measured for validity evaluation. The measurements of distances of stone models were used by digital vernier caliper and digital models were used by computer program. The mean${\pm}$deviations values of six distances were calculated. The means were compared by the Mann Whitney U test (${\alpha}=0.05$). All statistical analysis were performed using IBM SPSS Statistics ver. 20.0. Although digital models were smaller than stone models in six distances, there were no significant differences (p>0.05) and non exceeded the clinical acceptable range. The edentulous digital models for full denture fabrication can be considered clinically acceptable.

Study of the Data Exchange Format of GIS and CALS/EC System (GIS와 CALS/EC 시스템의 자료 교환 포맷 연구)

  • 이상길;정종철
    • Spatial Information Research
    • /
    • v.12 no.2
    • /
    • pp.151-163
    • /
    • 2004
  • This study aims to develop a standard protocol by which users can exchange data information efficiently between KOSDIC and GIS. The ultimate goal from this study is to propose a data exchange format using KOSIC. The background of this study is that GIS industry sector is vigorously developing linked to spatial information construction such as UIS, LIS, EIS, AM/FM through supporting by regional government institution. According to do, the format of data transformation becomes major issue. GIS data can easily transfer to CAD version but when CAD data convert to GIS format (DWG->DXF->SHP) cannot get high success rate due to errors and problems. In addition, CAD data feature is made from oriental structure which is made of point and line faeture so that GIS system is impossible to data transformation. In the reason, the biggest problem is discordance of symbolization in integration and standard of data format. By investigation the usability of this study, conclusion are drawn efficient alternative plan in data transformation. Though this wort we will be able to provide a better transformation of data conversion between CAD format and GIS format. Accordingly, it is of important to enrich the integrated construction information infrastructure, which accommodates ever-changing constructions environment.

  • PDF

Evaluation of Marginal Gap of Fixed Dental Prostheses Fabricated by Soft Metal Material Using Dental CAD/CAM (치과용 캐드캠을 이용하여 연질금속 재료로 제작한 고정성 보철물의 변연 간격 평가)

  • Kim, Jae-Hong;Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.14 no.3
    • /
    • pp.349-355
    • /
    • 2014
  • The purpose of this study was to evaluate marginal gap of fixed dental prostheses (FDPs) fabricated by soft metal material with using dental computer aided design/computer aided manufacturing (CAD/CAM) system and to compare gap of its by a conventional method. Ten same cases of study models were manufactured and scanned for digital models fabricating. Ten FDPs were fabricated by soft metal material using dental CAD/CAM (SMB group). Then, ten FDPs were fabricated by cast metal using lost wax technique and casting method (LWC group). Marginal gap was measured by silicone replica technique. Gap was measured by digital microscope (${\times}160$). Mann-Whitney test for statistical analysis was executed (${\alpha}=0.05$). The mean (standard deviations) of marginal gap was $76.5{\mu}m$ (35.2) for the SMB group, and $82.9{\mu}m$ (22.1) for the LWC group. Statistically significant differences were not found between SMB and LWC. As results, FDPs fabricated by soft metal material were clinically acceptable range.

Propagation Characteristics from Ingested Sources in Human Body (인체 내부 소스에 의한 전파 특성)

  • Kim Bo-Mi;Kim Young-Sik;Kim Se-Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.259-266
    • /
    • 2006
  • This paper presents the propagation characteristics from ingested sources in human body using the human model simulator. The simulator applies the FDTD method to the human data consisting of the human CAD and tissue data. After the accuracy of the simulator is verified, the received fields at one horizontal layer including the small intestine among the digestive organs are calculated in case that the electric field source is implanted in the center of the small intestine. The human propagation characteristics are illustrated by calculating the path loss per unit length according to various received positions from the simulated results.

Development of GIS Application using Web-based CAD (Web기반 CAD를 이용한 지리정보시스템 구현)

  • Kim, Han-Su;Im, Jun-Hong;Kim, Jae-Deuk;Shin, So-Eun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.3 no.3
    • /
    • pp.69-76
    • /
    • 2000
  • This study deals with development GIS application using web-based CAD, this application serves to user, designer, manager that more convenient and various functions. Development to this application, collect attribute data from fieldwork and geographic data from cadastral map and aerial survey map and then development to user interface using HTML, JavaScript, ASP, Whip ActiveX control. This application's characters are as follows ; First, system designer designed that anyone who have basic knowledge about web and CAD can develop this application. A system structure simplification by 2-Tier. Geographic information use DWF(drawing web format) file and attribute information use DBMS in consideration of extension. Second, system manager can service independently GIS in Web need not high priced GIS engine, so more economical. Third, internet user get service GIS information and function that search of information, zoom in/out, pan, print etc., if you need more functions, add function without difficultly. Developed application as above, not only save volume but fast of speed as use vector data exclude character and image data. Also, this application can used by means of commercial and travel information service but also various GIS service of public institution and private in web.

  • PDF

A study on 3D Modeling Process & Rendering Image of CAD Program-With Case study on Cellular Phone Design- (캐드에 의한 3차원 모델링 제작과정과 렌더링 이미지 연출에 관한 연구-무선 이동 전화기 디자인 사례를 중심으로-)

  • 이대우
    • Archives of design research
    • /
    • no.18
    • /
    • pp.25-34
    • /
    • 1996
  • Industrial design development methods and processes have changed in accordance with Industrial Information Age. These days, problems are created by existing methods and evaluation of design value , all problems concerned with time and finances sitaution have been made a subject of discussion. Development of design processes have been changed by the development of problem recognition and solving tools, and dpsign tpchnulugy havp hppn replaced by computer technology,Thus. software design processes linking thoughtware to hardware are used in the solution of design problems with many parts. In this study, 3D Modeling samples are presented, 3D Modeling can realise ' Ideas' to '3Dimentional Virtual Ohjects'. These effect and value are anle to decisively influence the process of design problem conference-ebealuation-solution.Proxesses of actual modeling and rendering are made as follows. By compusition of simple 20 drawings and shaping them into 30 objects, 30 solid models can be made. To prssent effectivley, we can make a sample model by varying camera views,light sourses,materials and colours etc. This sample is evaluated by various cumposition, methods and PERT(Program Evaluation and Review Technique). This cuncrete sample (tentative plan)is changed within the CAD SYSTEM by design evaluation, and then converted to flowchart of mass productive conception through refined data. So, that tentative plan can be conformed to design desire actuillly, to the utmost degree. Finally, this design process can be proposed as il new method in cuntrast with current methods. The aim of this study is to suggest effective evaluation methods of design outcome among many evaluating elements.

  • PDF