• Title/Summary/Keyword: 카트리지

Search Result 209, Processing Time 0.045 seconds

Simultaneous analysis of β-lactam antibiotics and β-blockers by LC-MS/MS (LC-MS/MS를 이용한 베타락탐계 항생제와 베타차단제의 동시분석)

  • Son, Bo-young;Kim, Jun-il;An, Chi-hwa;Lee, Su-won;Kim, Bogsoon;Chung, Deukmo
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.179-185
    • /
    • 2016
  • An effective analytical method has been developed for the determination of β-blockers(atenolol, metoprolol and propranolol) and 6 β-lactams(amoxicillin, penicillin G, cefaclor, cefadroxil, cephalexin and cephradine) in water samples using two different cartridges. The samples were extracted by solid-phase extraction (SPE) with the usage of polymeric hydrophile-lipophile balance(HLB cartridges) and strong cation-exchange mixed-mode polymeric sorbent (MCX cartridges). A XDB-C18 column(1.8 μm; 3.0 mm × 100 mm) was used for the sufficient chromatographic resolution. The calibration curves showed good linearity with high correlation coefficients (>0.995). The method detection limits (MDL) and the limits of quantification(LOQ) were from 1.1 to 3.9 ng/L and from 5 to 13 ng/L, respectively. The method was applied for the determination of the target compounds in tributaries and raw water of the Han River and these were found at N.D. to 0.209 μg/L.

Determination of Siderophore from Bacillus Mojavensis Using Liquid Chromatography quadrupole Time-of-flight Tandem Mass Spectrometry (액체크로마토그래피-사중극 비행시간형 탠덤질량분석기를 이용한 Bacillus mojavensis 균주 속 사이드로포어 규명)

  • Cheon, Hae In;Yeo, Mi Seon;Kim, Kang Min;Kang, Jae Seon;Pyo, Jaesung
    • Journal of Life Science
    • /
    • v.29 no.2
    • /
    • pp.198-201
    • /
    • 2019
  • Recently, it has been reported that Bacillus mojavensis possesses antifungal properties and plant growth-promoting activities, which are similar to the characteristics of siderophore. In this study, the siderophore produced by B. mojavensis was assessed using a solid phase extraction (SPE) cartridge and liquid chromatography quadrupole time-of-flight tandem mass spectrometry (Q-TOF MS/MS). After B. mojavensis was incubated in phenol medium for 16 hr and lyophilized, the sample was dissolved in water and loaded to an SPE cartridge to remove interferences. The cartridge was washed with 5% methanol in water and eluted with 2% formic acid in methanol sequentially. The eluted solution was evaporated under a stream of nitrogen gas and reconstituted in methanol. The reconstituted sample was filtered, and $1{\mu}l$ of the sample was assessed using Q-TOF MS/MS. The mass spectrometer was operated using the positive electrospray ionization mode. Based on the mass spectrum and tandem mass spectrum, the siderophore produced by B. mojavensis was bacillibactin, one of the catechol types of siderophore with a molecular weight of 882.2556. This siderophore analysis could provide a justification for the study of B. mojavensis as a functional food and for pharmaceutical applications.

Characteristics of Low Temperature Desorption of Volatile Organic Compounds from Waste Activated Carbon in Cylindrical Cartridge (원통형 활성탄 카트리지 내 폐활성탄의 휘발성 유기화합물 저온 탈착 특성)

  • Kang, Sin-Wook;Lee, Seongwoo;Son, Doojeong;Han, Moonjo;Lee, Tae Ho;Hong, Sungoh
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.79-84
    • /
    • 2021
  • In this study, the waste activated carbon used in the painting process was filled into a cylindrical cartridge and the characteristics of desorption by low temperature gas were investigated. Adsorption and desorption experiments of toluene with activated carbon were conducted to determine the flow rate of desorption. In an experiment where desorption was performed while changing conditions at flow rates of 1, 2 and 4 ㎥ min-1, it was determined that 2 ㎥ min-1 was appropriate due to the high THC concentration and desorption time. In the early stage of the desorption of waste activated carbon, 2-butanone and MIBK (methyl isobutyl ketone) with a low boiling point were generated at a high rate in the gas component, and after that, the concentration of THC decreased and the BTX was desorbed at a high rate. The total calorific value of the gas component generated during the desorption of waste activated carbon was 316 kcal kg-1. From repeating the regeneration of waste activated carbon with toluene five times, it was observed that the iodine value and the specific surface area were relatively lower than that of new activated carbon. In the desorption experiment where two cylindrical cartridges were connected in series, the maximum THC concentration was about 470 ppm.

Determination of acidic pharmaceuticals in aquatic environmental samples by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 수질 환경 시료 중 산성의약물질 분석방법 비교)

  • Sim, Young-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2008
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in aquatic environmental samples. Therefore, it required rapidly and certainly analytical method for pharmaceuticals which are existed in environment. In this study, Liquid chromatography/tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) was used to measure the concentrations of 7 pharmaceuticals (quinoxaline-2-carboxylic acid, acetylsalicylic acid, diclofenac-Na, naproxen, ibuprofen, mefenamic acid, talniflumate) from environmental water or aquatic samples simultaneously. Effective sample clean-up by solid-phase extraction (SPE) prior to LC-MS/MS analysis is necessary. For further purification, Mixed Cation eXchange (MCX) and Hydrophilic-Lipophilic Balance (HLB) solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. LODs (Limits of Detection) and MDLs (Method Detection Limits) for the spiked sample in fresh water were in the range of 0.05~1.50 pg/mL and 0.17~4.90 pg/mL, respectively. The absolute recovery in the concentration of 1.0 ng/mL were between 81.9 and 116.3%. The acidic pharmaceuticals were detected in concentrations of 0.018~16.925 ng/mL in aquatic environmental samples.

Optimization of Automated Solid Phase Extraction-based Synthesis of [18F]Fluorocholine (고체상 추출법을 기반으로 한 [18F]Fluorocholine 합성법의 최적화 연구)

  • Jun Young PARK;Jeongmin SON;Won Jun KANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.261-268
    • /
    • 2023
  • [18F]Fluorocholine is a radiopharmaceutical used non-invasively in positron emission tomography to diagnose parathyroid adenoma, prostate cancer, and hepatocellular carcinoma by evaluating the choline metabolism. In this study, a radiolabeling method for [18F]fluorocholine was optimized using a solid phase extraction (SPE) cartridge. [18F]Fluorocholine was labeled in two steps using an automated synthesizer. In the first step, dibromomethane was reacted with [18F]KF/K2.2.2/K2CO3 to obtain the intermediate [18F]fluorobromomethane. In the second step, [18F]fluorobromomethane was passed through a Sep-Pak Silica SPE cartridge to remove the impurities and then reacted with N,N-dimethylaminoethanol (DMAE) in a Sep-Pak C18 SPE cartridge to label [18F]fluorocholine. The reaction conditions of [18F]fluorocholine were optimized. The synthesis yield was confirmed according to the number of silica cartridges and DMAE concentration. No statistically significant difference in the synthesis yield of [18F]fluorocholine was observed when using four or three silica cartridges (P>0.05). The labeling yield was 11.5±0.5% (N=4) when DMAE was used as its original solution. On the other hand, when diluted to 10% with dimethyl sulfoxide, the radiochemical yield increased significantly to 30.1±5.2% (N=20). In conclusion, [18F]Fluorocholine for clinical use can be synthesized stably in high yield by applying an optimized synthesis method.

Application of electrets (일랙트렛트의 응용)

  • 황명환;이덕출
    • Electrical & Electronic Materials
    • /
    • v.6 no.4
    • /
    • pp.302-310
    • /
    • 1993
  • 일렉트렛트이란 자석과 대칭한 호칭으로 영구전기분극을 갖는 절연체를 말한다. 일랙트렛트는 1919년 강구에 의해 창제되었는데 이것은 왁스와 송지를 등량으로 혼합하여 만든것이었으나 최근에는 테프론이나 마이러, 폴리프로필렌등의 고분자 필름으로 만들게 되었다. 많은 고분자 재료는 절연성이 좋고 가공 성형도 용이하기 때문에 일랙트렛트로 하기에 편리하다. 그중에서도 합성고분자 필름에 의한 일랙트렛트는 마이크로폰이나 카트리지 등의 음향소자에 쓰이는 외에 정전모우터, 릴레이스위치, 에어필터나 의용재료에 널리 이용될 가능성이 나오고 있다.

  • PDF

Sample Pretreatment and HRGC/HRMS Analysis for Determination of Dioxins in Environmental Samples (환경시료 중 다이옥신류의 정량을 위한 시료전처리방법의 개선 및 고분해능 GC/MS 분석에 관한 연구 Ⅰ)

  • Kim, Jin Yeong;Jang, Yun Seok;Lee, Dae Un
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.11
    • /
    • pp.819-826
    • /
    • 1994
  • This study described a simple, rapid and cost effective analytical technique for the ultra-trace analysis of dioxins in environmental samples. Liquid-Liquid extraction methods were used for the initial extraction and enrichment of the analyte. Subsequent clean-up procedures were achieved by using strong cation exchanger, silica and Florisil cartridges. Extracts were analysed by HRGC/HRMS-SIM. The efficiency of these analytical methods was tested by recovery and selectivity for elimination of interferences such as phenols, pesticides and PCBs in each step. The mean recovery of 1,2,3,4-TCDD spiked at 10 ppt in sea water was about 92(${\pm}$1.6)%. This analytical method was applied to Kwangyang sea water and 4.5pg/L of 2,3,7,8-TCDD was determined.

  • PDF

The Study of the Characteristic of Pyrotechnic Separation Devices Using Missile System and Space Craft (우주발사체 및 미사일 시스템에 이용되는 파이로테크닉 분리장치의 특성에 관한 연구)

  • Lee, Yeung-Jo;Kim, Dong-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.208-211
    • /
    • 2007
  • Separation Devices have two functions. These two functions are to bond and to separate two bodies. This paper is about separation devices which use explosives to separate their bodies. Explosive bolt is separated with two bodies when the explosives in the body detonated. The good things of explosive bolt are that it has simple operational system and it is made of few parts. But it has side effects; fragment and pyre-shock. To avoid these side effects gas expansion separation(GES) bolt and pressure cartridge actuation separation(PAS) devices are invented. These use pressure to separate their bodies. The pressure is generated when explosives are burned. But the sizes of PAS devices are bigger than explosive bolts. And GES bolt has a mechanically lower bonding ability than that of explosive bolt. When you design separation devices, it is recommended to know operational system and characteristics of separation devices, to design best one.

  • PDF