• Title/Summary/Keyword: 침투 및 진단

Search Result 151, Processing Time 0.029 seconds

A Study on Characteristics of Concrete Impregnated with the Inorganic Surface Penetration Agents (무기계 표면침투제 용액으로 함침한 콘크리트의 특성 연구)

  • Bae, Ju-Seong;Kim, Hyeok-Jung;Park, Gook-Jun;Han, Jong-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.71-77
    • /
    • 2010
  • The concrete structure's durability and integrity is reduced owing to various deterioration phenomena. Therefore, it is important to prevent the deterioration phenomena. This study inquired into the various experimental results of specimens with different dilution concentration and impregnation time by the each solution to present the economic and efficient using method of the inorganic surface penetration agents. As a results, the reasonable dilution concentration and impregnation time of colloidal silica solutions are 15% and 5 minute and for the sodium alumina silicate solutions are 17% and 10 second.

Assessment of a fresh submarine groundwater discharge in eastern Jeju Island using analytic seawater intrusion models (해수침투 해석해 기반 제주 동부 담해저 지하수 유출의 정량적 산정)

  • Kim, Il-Hwan;Chang, Sun Woo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.12
    • /
    • pp.1011-1020
    • /
    • 2022
  • Previous studies for the assessment of submarine groundwater discharge (SGD) were perfomed for areas where a large amount of SGD was observed. Newly developed assessment methods were proposed that was based on an analytic solution using sharp interface model. The proposed mathematical equations used the existing observed groundwater level and hydrogeological data of Jeju Island as input data. The quantitatively assessed FSGD values were compared to the basin-scale recharge estimation values in Seong-San area in eastern Jeju. As a result of the study, it was estimated that the amount of FSGD in the Seongsan area ranges from about 2.65 to 9.15% of the amount of areal-recharge. Through the analysis of the FSGD combined with the analytic model, it is to be provided as a scientific tool to establish a more reasonable coastal water resource management plan.

A Study on Durability Improvement for Concrete Structures Using Surface Impregnant (표면침투제를 이용한 콘크리트의 내구성 향상에 대한 연구)

  • Kwon, Seung-Jun;Park, Sang-Sun;Lee, Sang-Min;Kim, Jeong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.4
    • /
    • pp.79-88
    • /
    • 2007
  • Concrete structures undergo degradation of durability performance and it generally propagates to the structural problems. Recently. a lot of materials for surface protection for concrete are developed, however, performance is not clearly improved due to the difficulties such as repair construction technique and quality of materials for repairing. In this study, liquid inorganic impregnant for concrete structures is developed and durability performance for impregnated concrete specimens is carried out. Furthermore, the performances of the concrete specimens with developed impregnant is also compared with those of the specimens with impregnant conventionally used. Additional CSH gel is formed through the reaction of calcium hydroxide ($Ca(OH)_2$) and impregnant with silicate. As a result of the reaction, impregnated concrete is evaluated to have more denser surface and resistance to deterioration. Finally it is experimentally verified that the concrete specimens with developed impregnant show better durability performance than normal specimens and those with conventional impregnant.

Compressive Strength and Chloride Ion Penetration Resistance of SHCC Coated by PDMS-based Penetrating Water Repellency (PDMS 흡수방지재를 적용한 SHCC의 압축강도 및 염화물이온 침투저항성)

  • Lee, Jun-Hee;Hyun, Jung-Hwan;Park, Su-Hyun;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.16-23
    • /
    • 2018
  • In this study, Polydimethylsiloxane (PDMS) was applied to Strain Hardening Cement Composites (SHCC) for penetrating water repellency. The penetration depth of PDMS, strength of SHCC, and chloride ion penetration resistance of SHCC were investigated. As a result of measuring penetration depth of PDMS when applying different application method, it was confirmed that all methods satisfied the requirements of KS F 4930. Although the immersion method showed the largest penetration depth, the spray method was considered to be more appropriate considering the ease of field application. Compressive strength tests showed that the penetration depth of PDMS decreased as the compressive strength of SHCC increased. The compressive strength of M4-A and M4-B specimens with large PDMS penetration depths decreased by 9.6% and 8.0%, respectively, compared with those of M4 specimens produced without PDMS. Compressive strengths of the M1-A and M1-B specimens with small PDMS penetration depths were reduced by 4% and 2.2%, respectively, compared with the M1 specimen. As a result, it can be seen that the strength reduction rate of SHCC increases as the penetration depth of PDMS increases. The chlorine ion penetration tests showed that the chlorine ion penetration resistance increases with the penetration depth of PDMS.

Analysis of Soil Saturation Characteristics According to the Presence or Absence of Soil Layer Depth and Impervious (침투해석시 토층심도 및 불투수층 유무에 따른 지반의 포화특성 분석)

  • Lee, Seung Woo;Chang, Bhum Soo;Kim, Yong Soo;Lee, Jong Gun;Lee, Ju Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2013
  • In recent study, infiltration analysis considering rainfall intensity is more economical and practical than existing analysis method. Revised construction slope design standard is also stated to full-fill infiltration analysis considering rainfall for practical stability review. Infiltration analysis considering rainfall for practical stability review. But, to infiltration analysis, the process is complicated by ground impermeability and rainfall intensity. In this study, we perform infiltration analysis to charge infiltration conditions, soil type and rainfall characteristics, for more pratical stability review. Using the result, we can suggest construable condition on the assumption that soil is saturated up to surface zone.

Experimental Study on the Penetration Depth and Concentration of Corrosion Inhibitor Using Press-in Method Into the Inside of Concrete (콘크리트 내부로의 압입공법을 사용한 방청제의 침투깊이 및 농도에 관한 실험적 연구)

  • Cho, Hyeong-Kyu;Yoo, Jo-Hyeong;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.160-168
    • /
    • 2009
  • After steel bar was corroded it removes concrete contaminated, it does steel bar corrosion protection, repairing method and corrosion inhibitor spreading method are difficult to secure corrosion protection performance. Accordingly, in this research before Research and Development to penetrate corrosion inhibitor to high pressure by steel bar position, it measures penetration depth through corrosion inhibitor high pressure penetration experiment and amount of nitrite by position and then it predicts penetration depth in accordance with water-cement ratio, pressure, pressure time and it computed water-cement ratio, pressure, pressure time to be more than 0.6 mol ratio of chloride ion and nitrite to have outstanding corrosion protection performance. As a result of experiment, water-cement ratio gives the biggest influence to penetration of corrosion inhibitor and also the more depth of specimen becomes deep, concentration of penetrated corrosion inhibitor does not equal and becomes low.

Chloride Ion Penetration Properties of Normal Strength High-Fluidity Concrete Using Lime Stone Powder (석회석 미분말을 활용한 보통강도 고유동 콘크리트의 염소이온 침투특성)

  • Choi, Yun-Wang;Moon, Jae-Heum;Eom, Joo-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.160-168
    • /
    • 2010
  • Recently, there are a lot of researches related to the high-fluidity concrete (HFC) with field applications. However, most applications and studies are with concretes with high strength level so there are little studies about durability evaluations such as chloride ion penetration properties with normal strength concrete. Therefore, to evaluate the durability of HFC with normal strength level, this study performed the chloride ion penetration test and observed the micro pore distribution with normal strength HFC which contains limestone powder. Experimental results showed that most micro-pores have diameters between 0.005 to 0.05 ${\mu}m$ with HFCs using limestone powder and the average diameter becomes larger with the increase of limestone powder content. Also, it was shown that, with the increase of the limestone powder content, penetration depth and diffusion coefficient of chloride ion increased and diffusion coefficient had good relationships with compressive strength and average pore diameter with the coefficient of determination over 0.90.

Acute Type A Aortic Dissection Mimicking Penetrating Atherosclerotic Ulcer (침투성 동맥경화성 궤양과 흡사한 급성 A형 대동맥 박리증 -1l례 보고 -)

  • Choi, jae-Sung;Kwak, Jae-Gun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.30-34
    • /
    • 2003
  • As classical acute aortic dissection, atherosclerotic penetrating ulcers and intramural hematoma have different pathophysiology and natural history, treatment strategy should be different and, therefore, accurate differential diagnosis is necessary. However, these three aortic diseases may be indistinguishable by clinical observation and even by various diagnostic modalities such as cardiac echocardiography, CT and MRI. The patients was a 71-year-old female with chief complaints of anterior chest pain, nausea and vomiting which occurred suddenly 3 days before admission. CT angiographic with 3 dimensional reconstruction shows intramural hematoma in ascending aorta, aortic arch, descending thoracic aorta and right brachiocephalic trunk, heompericardium, and blood in mediastinum and both pleural cavities. The CT angiographic finding of focal out-bulging in the ascending thoracic aorta was diagnosed as penetrating atherosclerotic ulcer. The patient underwent emergency operation under a preoperative diagnosis of penetrating atherosclerotic ulcer with a sign of aortic rupture. In the intraoperative findings, however, intimal tear was seen in the anterior portion of the ascending aorta about 1cm below the brachiocephalic trunk and falselumen appeared after hematoma was removed from the layer of tunica media. We report a case of type A aortic dissection which mimicked clinical and diagnostic features of penetrating atherosclerotic ulcer.

Effect of Initial Flexural Crack on Resistance to Chloride Penetration into Reinforced Concrete Members (초기 휨균열이 철근콘크리트 부재의 염화물침투저항성에 미치는 영향)

  • Yang, Eun Ik;Jin, Sang Ho;Kim, Myung Yu;Choi, Yoon Suk;Han, Sang Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.79-87
    • /
    • 2011
  • In this study, the chloride penetration tests were performed for the initially cracked reinforced concrete members. The chloride diffusion characteristics and the critical crack width are compared, and the properties of self-healing are investigated. According to the test results, the chloride penetration resistance was greatly reduced as the surface crack width increased. When the mineral admixtures are added, the chloride penetration resistance of uncracked specimens were effectively increased, however, in case of the blast furnace slag and fly ash, the cracked specimens showed the more reduced resistance than OPC case, inversely. Also, the critical width was $29{\mu}m$, on average, for immersion test. The crack width with $4{\sim}15{\mu}m$ was restored by self-healing, The parts restored by self-healing were seemed to be visually restored, however, the chloride penetration resistance was not restored, perfectly.

Effects of Fine Aggregate Size on Penetration Performances of SSPM (잔골재의 입도분포가 SSPM의 침투성능에 미치는 영향)

  • Yoon, Hyun-Kwang;Youn, Da-Ae;Lee, Chan-Woo;Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.25-31
    • /
    • 2019
  • This study was conducted to evaluate the penetration performance of the Silane Surface Protection Material (SSPM) penetrating the micro pore of concrete surface. The results was indicated microstructure, porosity and penetration depth of applied SSPM. Silica sand and conventional sand were used as fine aggregate in mortar. And liquid and cream types SSPM were used. The amounts of SPM were applied the 127, 255, 382, 510 g/m2 on the surface of mortar. The penetration depth specimens were made with $100{\times}30mm$ in according with KS F 4930. Penetration depth was evaluated according to KS F 4930, divide specimen and then spraying with water in cross section of specimens, and measure the depth of the non-wetted area. The microstructure result of mortar applied SSPM, it was obtained liquid and cream SSPM in mortar. The porosity results of SSPM application specimens were improved with than that of plain specimens. Test results indicated that the penetration depth of SPM were improved with increasing in amounts of SSPM. As a result of test, application of SSPM to concrete surface, it will improve durability.